Single Wire 6kv Cylinder Type Transformer काम कैसे करता है
Vložit
- čas přidán 27. 08. 2024
- my website
www.sunvoam.com/
download free diagram,books and solar information
my website link
www.mrsewak.net/
my facebook page
/ mr-sewak-mec. .
follow instagram
/ mrsewakmech. .
my multimeter buy amazon
amzn.to/2TLgnTE
loom solar 375 watt solar buy
amzn.to/2AiMHq5
digital volt amp watt pf all in one meter buy
amzn.to/2BaTCSX
wd40 buy amazon
amzn.to/2TMeIxe
microtek solar inverter buy amazon
amzn.to/2M7qQVy
utl gamma plus buy amazon
amzn.to/3esfjMI
utl solar pannel buy amazon
amzn.to/3dcEUc7
e cycle kit buy amazon
amzn.to/2TJGx9s
utl smu buy link
amzn.to/2X84hWO
smarten mppt solar smu buy amazon
amzn.to/36Axa14
microtek solar smu buy amazon
amzn.to/2TLKOt6
775 moter buy link amazon
amzn.to/2XGoO3Q
Electronic Digital Vernier Caliper Ruler Carbon Fiber Composite 6inch 150mm
amzn.to/2XBbOfX
Stanley 70-964E Combination Spanner Set
amzn.to/36Jt9rm
mp4 video card buy link
amzn.to/2DloIqP
my microphone buy link amazon amzn.to/2M4L2Yb
my tripode kodak buy link amzn.to/2yIodGA
my gimble buy link amzn.to/3ejcTQm
ਬਹੁਤ ਹੀ ਵਧੀਆ ਜਾਣਕਾਰੀ ਦਿੱਤੀ ਗਈ ਹੈ ਸਰ ਗੁਰਸੇਵਕ ਸਿੰਘ ਜੀ
Thanks my dear boy. Ap mere teacher hai. Apko salute kerta hun.
Teacher ko boy kah'kar mukhatib karte ho Muneer sahab Upper se Muallim yane teacher bi ho .
Nice, very informative video thanks for sharing
This type of transformers are always very risky due to poor Earthing .
Imagine if the earth wire disconnected because of rust after a few years. And if someone touches it - instant death from 6KV.
@@skmishra91
Definitely
बहुत ही अच्छी जानकारी दी है आपने बहुत बहुत धन्यवाद आपका।
Veer g. Bhut badi knowlege di aapne.Apko bhut thank you.
bhut time se dekh rha tha but etna best kese ne nhi samjhya
सिलिंडर टाइप ट्रांसफॉर्मर🤔🤔🤔,6300 वाल्ट मिलते है🤔🤔🤔, अर्थिंग अलग-अलग होनी चाइये🤔🤔🤔,nicee वीडियो सेवक जी😊😊👌🏼👌🏼🇮🇳🇮🇳🙏🙏🙏
हाई वोल्टेज वाला अर्थिंग बॉडी से शार्ट होना चाहिए
इंस्टॉल करने वाला लाइनमैन कनेक्शन गलत कर दिया है
बहुत महत्वपूर्ण व गम्भीर जानकारी बताई है आपने,,, विधुत विभाग प्रायः सब जगह ये ही कार्य करता है, हमारे राजस्थान मे तो 100% इसी एक ही अर्थिंग से HT LT को जोड़ते हैं जो एकदम गलत है।
Kya is transform se chori ki ja sakti h
sir mai aapka har vidio dekhta hu ,aap sahi bol rahe ho agar grounding wire tuta to voltage bahut jyada bad jayega
Bai sewak ji. App k har videos k but wait hota he
बहुत ही ज्ञान जनक वीडिओ है धन्यवाद सेवक जी
ਬਿੱਲਕੁੱਲ ਸਹੀ ਕਿਹਾ ਸੇਵਕ ਵੀਰ ਜੀ
Jankari dene ke liye dhanywad
Ghar main dono line main current a sakta hai good informatian pra ji
*I like This Type Of Video,* 👌
*Make More Educational Video On Same Type* 👍
What is your phone no.
Thanks for the information
Main bahut salon se yeh shoch rahatha. Thank you🙏
ਇਹਦਾ ਵਿਰੋਧ ਕਰਨਾ ਚਾਹੀਦਾ ਹੈ ਗਲਤ ਹੈ ਇਹ ਕਿਸੇ ਨੂੰ ਵੀ ਭਾਰੀ ਨੁਕਸਾਨ ਕਰ ਸਕਦਾ ਹੈ
Chalo dharna laun chaliye
VERY NICE AND INFORMATIVE VIDEO DEAR RESPECTED SIR 💟👍🙏
1a
Thank you .very useful information
This type transfarm earth must be from the gridde. Very danger if you earth not coming from the ground. Thanks sir Good Information.
bhut kam ki video he ser
बहुत ज्यादा अच्छी विडीओ हैं
ਮਨ ਦੀਆਂ ਗੱਲਾਂ ਸਮਝ ਲੈਂਦਾ ਭਾਈ ਤੂੰ
Very nice great knowledge ✍️✍️👍👍
बहूत बेहतरीन विडीओ बनाया है भाई आपने। 👍👍👍👍👍👌👌👌nice👍
Dear you are told correct most of cases contrecter save there money
when I was working at state electric
city up I was point out but officers
press to this case its a 100% unsafe.
To aap sirf hv side hi earth kare lv side na kare koi dikkat ni ayegi
Good information
Diagram se achha samaj aaya thanks
Samjhane ke liye shukriya ji
ਬਹੁਤ ਖਤਰਨਾਕ,ਜੇਕਰ ਅਰਥ ਟੁੱਟ ਗਈ ਤਾਂ ਹਾਈ voltage ਘਰ ਚ ਜਾ ਕੇ ਭਾਰੀ ਤਬਾਹੀ ਮਚਾ ਸਕਦੇ ਨੇ।HT ਸਾਈਡ ਦੀ ਅਰਥ ਅਲੱਗ ਹੋਵੇ ਤੇ ਓਹ੍ਹ ਵੀ ਹਾਈ insulated ਕੇਬਲ ਇਕ ਪਾਈਪ ਜੋ ਪਲਾਸਟਿਕ ਦਾ ਹੋਵੇ ਉਸ ਵਿਚੋਂ ਬਹੁਤ ਡੂੰਗੀ ਹੋਣੀ ਚਾਹੀਦੀ ਹੈ। ਥੋੜ੍ਹੀ ਜਿਹੀ ਵੀ ਅਣਗਹਿਲੀ ਮੌਤ ਨੂੰ ਬੁਲਾਵਾ ਦੇ ਸਕਦੀ ਹੈ। ਤਿੰਨ ਫੇਸ ਟਰਾਂਸਫਾਰਮਰ ਜਿਆਦਾ ਸੇਫ ਹੁੰਦਾ ਹੈ।
Gjb information...... $
Nice informations. Thank you sir
nice information sir ji
जानकारी देने के लिए आपका बहुत बहुत धन्यवाद
Nice video by ji.
Thank you Sir 🙏
Nice video Guru ji
Nice information....bade bhai
Love you....
Nice video im follows on Facebook ur videos see fariest video on CZcams .
good pa ji
pajji hun sahi information a 👍
सेवक जी खेतो मे अथ केसे करते है और कीतना लमबा सरीया लेते है ईस पर एक वीडीयो बनाऔ
Good knowledge sir
ਸਾਡੇ ਵੀ ਲੱਗਾ ਪੈਰ ਵਾਲਾ ਅਰਥ ਨਾਲ ਕਰੱਟ ਆਦਾ ...ਝੋਨੇ ਵੇਲੇ ਬਹੁਤ ਡੱਡੂ ਸੱਪ ਮਰਦੇ...
Sir आप एक automatic stairs light 2 sensor 20 step पर वीडियो बनाओ
Thank you aapko
Very nice information
Shri transformer mein all sahi hai donon boxing Sahi hai jab bhi main supply Nahin nikalta 5 KB ka
Nice video. Sir
Earthing ka wire pehle Cable k through Earthing krna chahiye..
Dusra eisa Supply koi bhi ghar pe nhi leeta.
Aur earthing tutne ka Dhar bohot hi km hai.. q ki eisa case bohot hi rare
Earth Wire Ko Propore Insulation Karna Chahiye
Very good
sir agar barish main aisa incident ho toh khattra banta hai sir. mtlb transformer ke neutral point ki baat kr reha leakage time sir ki earth time khatra bnn skta hai please explain sir ki ohms 8 se km chahiye jaise low resistance pr current jaldi flow hoga ussi tra se .agar baarish main neutral point leakage kre toh current earth ho jayega pr rod ke ale doale je pani krha hove tan risk ni hega veer g dsyo jrur
Very informative
Arth par video banao
N 1 and N2 how much distance there earth
5 meter
KeeP IT UP
Thanks for information
Good luck
2n agar break ho jaye ya fir kisi vajah se kam na kre to
6000 coil se ghuma fira kr ghar me dakhil ja jayega Jo bhi uske samne hoga use lekar chala jayega
You are right
भाई साहब यह ट्रांसफार्मर 4 खंबे के साथ कितने रूपए में लग जाएगा
और क्या हम खुद स्वयं इसे लगवा सकते हैं या फिर विद्युत ठेकेदार के द्वारा लगवाना पड़ेगा
अभी अर्जेंट ही लगाना है जल्द से जल्द सही उत्तर देने की कृपा कीजिए
Demand pr hai sab
Earth tutne ka nukasn garmiyo me hota he ser jab light ja sak ekdam se aati he tab bhut nuksan hota he
👍👌
Sir yea Transformer kaise lgayea mara ghr me Current nhi hai but mra ghr se hoke 12000 hajar volt ka wire cross kiyea h lkhn transformer nhi hai supply ka
Gazab nice
ये रिश्क 3 फेस ट्रांसफर में भी रहता है अगर डेल्टा वांईंडीग का तीनों व्यार के न्यूट्रल ज्वांइट में से किसी एक तार के कट जाने पर ।
सिंगल tansphar में कितना वजन होता है भाई साहब
Nice 🙏🙏🙏🙏
No need to earth output it would work properly we have this type of transfer
It will work, but in LV side Neutral will not be always zero voltage if it is not properly earthed
Here if only HV side is earthed then it will work fine too. What is problem in this case??
It will work, but in LV side Neutral will not be always zero voltage if it is not properly earthed
Single phase transformer kitna load le skata ahai ..
Mere pass 3 phase wala ahai 63Kva but
Single phase 24 hours haia
Mera load 40/50 kva ma ahai
With out voltage drop chelega ?
Sir . 6 kva single phase tranformer complete installation price kitna ata hai. Or 6 kva single phase tranformer se water R.O plant 1000 per hours' capacity installation kar sati hai..
ईसका खर्चा कितना आता है ?
Ghar m earth laga lo tab.
Maine grid se ek hi phase liya hai aur neutral aone handpump se leta hu😀
Phase lo yeea fir neutral loo meter pr dekhna kwh ka led blinking kr rha hai..
Q ki aaj kl ka sabhi Meter mein yeh ek advanced technology lga hua hai
@@nazmulhassan7008 meter nahi hai
@@vaibhavsingh6336
😂😂😂😂😂😂To fir tik hai 😂😂
होता है न्यूटन टूट जाने से वर्ल्ड ज्यादा आती है हमारे यहां पर जमीन न्यूटन टूट गया था वर्ल्ड ज्यादा,😔💥
उत्तम भारत ट्रांसफॉर्मर जहां बनता है वहां हमने काम किया है
ese important bat verji earth ke liye 220 ke liye LV ke liye pani ke borwll ke casing lohe ke pipe ko use kar sakte he kya
Hum apna sa is formula ko use karka 2kva ka t/f banena chatahu but bijli office sa permission nahi mul raha
Mreko नया लगवाना है गुरु जी
❤
es earth ke taar ko pack ya insulated honi chye
Haaaa bhai insulated hai yeh wire already
Three phase transformer per 3 phase 11000 Hoti hai per phase vahi se 1 wire ATI hai to 6000 kaise hui please sir details information
Welding shop main 10kv transformer use Kar sakte Hain kya
Iske lakshan ko kaise karvayen kitne group mein ho gaye kitne rupya kharcha JAVA collection mein
Ji sir mere yaha hota ge esa
Singel phase transformer nu Arth kinna dunga krna chahida assi 10 feet sariya lgaya hai ki oh sahi hai plz rply
मेरे घर इसी प्रकार का सिंगल फेज ट्रांसफॉर्मर लगा हुआ है, जिसमे एक फेज व एक न्यूट्रल के रूप में 240v ac आउटपुट मिल रहा है, लेकिन इसका फेज व एक अन्य अर्थ को जोड़कर कोई उपकरण चलाएं तो उससे कोई भी उपकरण या बल्ब नही चलता, जबकि इसके दोनों आउटपुट टर्मिनल से कोई भी उपकरण चल जाता है ऐसा क्यों????
थ्री फेज ट्रांसफार्मर में तो एक फेज व एक अन्य अर्थ को लेकर हम कोई भी उपकरण चला सकते हैं क्योंकि अर्थ भी न्यूट्रल की तरह कार्य करता है।
jahaa tak mujhe lagta hai agar eartihing alag karay gay tou 220 voltage means secondary mai load daine se voltage drop hojayee ga
सर हमारे यहां 11 kv का ट्रांसफार्मर है सिंगल फेज वाला जिसमे 11 kv का दो फेज जोर दिया जाता है मैं बिहार के मुजफ्फरपुर से हु
भाई यह सरासर गलत है इस में 4गराउन्ड़ अर्थ होना चाहिए 2न्यूट्र्ल के लिये और 2अर्थ के लिए तथा 20फुट डीप गराउन्ड़ मे तार या ईस्ट्रिप जानी चाहिए और हर अर्थ की आपस में दूरी 6मीटर रखनी चाहिए 🙏
Single phase trasfarmer to chek kaise kar ke je sadd chuka he
Jisse is transformer ko ground Kiya Hai vah cable aluminium Ki Hai yah lohe Ki hai? Jawab jarur dena.
Mujhe lena hai transformer special
Sir earthing ka simbol glat hai yeh to air antina ka symbol hai
▄︻̷̿┻̿═━一☜☆☞kitne me rkh dete bijali wale
Right......
3 HP motor chalega
Mey. Aek. Fitar. Hun. Oarth.Aalag.Aalag.hona.chahiy