Transient Thermal Analysis using Hypermesh [Optistruct Tutorial]

Sdílet
Vložit
  • čas přidán 15. 08. 2024
  • In this Optistruct tutorial, we will perform a transient thermal analysis using Hypermesh. This will be a linear transient heat transfer analysis of exhaust manifold.
    CAD Model Link : drive.google.c...
    Recommended Videos :-
    Thermal stress analysis using Optistruct : • Thermal-Stress Analysi...
    Thermal analysis using Hypermesh : • Thermal Analysis using...
    Topology Optimization using Optistruct : • Topology Optimization ...
    #aeroswap #hypermesh #fea #cae #aeroswap #fea #hypermesh #cae

Komentáře • 69

  • @muhammadaliabid5793
    @muhammadaliabid5793 Před 3 lety +1

    another amazing tutorial! Cannot be created better than this
    hats off!

  • @donotopen6597
    @donotopen6597 Před 3 lety

    Been waiting for this. Thankyou.

  • @bilalqureshi941
    @bilalqureshi941 Před 2 lety +2

    In card image, There's no TLOAD1. And some other cards are also missing like slave1/2
    Please help how can i enable them!!

    • @Aeroswap
      @Aeroswap  Před 2 lety +1

      Hi Bilal, make sure that you are using the Optistruct interface of Hypermesh. You will not find these options in any other solver interface.

  • @dhruvdroids
    @dhruvdroids Před rokem

    Thanks bro. Helped me brush up thermals

  • @stanislavsidnei1055
    @stanislavsidnei1055 Před 7 měsíci

    Good health, please tell me how to open RTH files. I’m interested in how the temperature is distributed over the cross section regardless of time, namely over the cross section, that is, the coordinate points of the surface of the part

  • @hristijanmazganski7102

    Maybe CFD Tutorial for Pump will be useful for us too :) BTW thanks @aeroswap for tutorials, great job

  • @adibadzaman3501
    @adibadzaman3501 Před 3 lety +2

    nice video. can you make a tutorial on thermal analysis of resistance spot welding using Optistruct? hope to see more tutorial from you

    • @Aeroswap
      @Aeroswap  Před 3 lety +2

      Thanks for the suggestion. I will work on this topic soon!

  • @adibadzaman3501
    @adibadzaman3501 Před 3 lety +2

    i have question, for the ambient temp node, why you place the node there? or is it can be place anywhere near the model?

    • @Aeroswap
      @Aeroswap  Před 3 lety +3

      Hi Adib,
      The ambient node can be placed anywhere in the model. It's location does not affect the analysis. The only reason why I created it near the pipe is because it was easy to extract the center node.

    • @adibadzaman3501
      @adibadzaman3501 Před 3 lety +1

      @@Aeroswap i see. got it thank you sir

  • @jardeldeckmann2
    @jardeldeckmann2 Před rokem

    There is no TABLED1 option on curves... i have just LINEAR option. I'm using the 2019 hypermesh version

  • @user-no4ek9hd4o
    @user-no4ek9hd4o Před 6 měsíci

    can you make the same video with the new software 2023 version

  • @vinodraj60
    @vinodraj60 Před 3 lety +1

    @aeroswap Hi Guys ! have you posted any videos for fatigue ?

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Not yet. I am working on a fatigue analysis tutorial. Hopefully, it will be posted soon!

  • @onkarjalkotkar5647
    @onkarjalkotkar5647 Před 3 lety +2

    TEMPD card image is used maximum time in thermal analysis. But I didn't know when to use it, could you tell me?

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Hi Onkar,
      TEMPD defines reference temperature in a thermal analysis. It is used to specify the temperature units (usually Kelvin or degC). As Hypermesh is a unit neutral evnironment, TEMPD provides a base point for the temperature range.

  • @emmanuelvassilakis5630
    @emmanuelvassilakis5630 Před 3 lety +1

    First comment! Nice work Swapnil, Excellent presentation of transient thermal analysis. Btw: How do you change the "D" value on an already defined spc_temp? Thanks!

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Thanks Emmanuel :)
      For that you can use the card edit option. Set the entity selector to 'Loads' and select that spc. Then you can edit the card and change D value.

    • @emmanuelvassilakis5630
      @emmanuelvassilakis5630 Před 3 lety +1

      @@Aeroswap Thanks for the reply Swapnil

  • @saivijay5626
    @saivijay5626 Před 3 lety

    if i use temp of 2000 degrees in spc_temp and spcd_temp as d=1, And in case of spc_ambient as 25 degrees and spcd_ambient as 1. i got my results with error and in my problem i need 2000 degrees temp and 25 degrees ambient temp shouldbe taken. help with this

  • @RamyaM-wx5xe
    @RamyaM-wx5xe Před 5 měsíci

    Hello Sir Im Unable to edit material properties how to resolve this

  • @chinguyenphung4671
    @chinguyenphung4671 Před 2 lety +1

    hi sir
    in the load step ( analysis type , heat transfer )
    i dont have the IC
    why ????

    • @Aeroswap
      @Aeroswap  Před 2 lety +2

      You need to use analysis type as 'Heat transfer transient'. IC will not be available in 'Heat transfer steady state'.

  • @zeeshansayed204
    @zeeshansayed204 Před 5 měsíci

    7:07 why did you gave 85 degrees was that in problem statement?

  • @mohdzavi5895
    @mohdzavi5895 Před 3 lety +1

    Please make a video of Fatigue analysis of an engine block
    (E N Strain Life Method) using FPM in Hypermesh.

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Thanks for the suggestion. I will work on this topic soon.

  • @shashwatnaik9523
    @shashwatnaik9523 Před 2 lety +1

    I have a question, in SPCD why we have used multiplier value as 1? what does it signifies?
    Thank you and looking forward to your reply

    • @Aeroswap
      @Aeroswap  Před 2 lety +2

      Hi Shashwat,
      1 is the scale factor for SPCD. It signifies how much temperature will be applied at the location. If you enter it as 0, you will not get any temperature rise and if you enter it more than 1, you will get a greater temperature rise than shown in this tutorial.
      I hope this clears your doubt!

    • @shashwatnaik9523
      @shashwatnaik9523 Před 2 lety +1

      @@Aeroswap Thank you for the reply....got it👍🙌

  • @anilkonderu848
    @anilkonderu848 Před 3 lety +1

    Can you please tell me how to apply thermal gradient loads for shell elements. Like different temperatures for top fiber and bottom fiber of shell element

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Hi Anil,
      Shell elements have constant parameters in thickness direction. Hence it is not possible to apply different temperature on sides of the same shell element. To do this, please use brick (hexa-penta) elements.

  • @saikumarmadala2793
    @saikumarmadala2793 Před 3 lety +1

    Hi sir, without linking 3 or more materials with each other for a component in one bulk entry data and keeping each material in one subcase, can we perform a static or thermal or any other analysis and displaying the results for each case(i.e for each material) and by keeping the load collectors for all materials as same. It is possible?

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Yes, but you can assign only one material to each component. Therefore, you will have to create separate FEM files if you want to test a particular component with different materials.

    • @saikumarmadala2793
      @saikumarmadala2793 Před 3 lety +1

      @@Aeroswap Thank you sir

  • @muhammadaliabid5793
    @muhammadaliabid5793 Před 3 lety +1

    Dear Swapnil! One question please:-
    You clicked conv_cont while performing Engine Block coupled thermal stress analysis tutorial
    but not this time! Can you explain what is conv_cont while linking convection interface to ambient temp. please?

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Hi Ali,
      It is just a part of creating Hypermesh comments for a specific card (This helps in solver deck export operations). It does not affect the analysis results in any way. You can simply skip that step and complete any thermal analysis setup!
      I hope this information helps :)

    • @muhammadaliabid5793
      @muhammadaliabid5793 Před 3 lety +1

      @@Aeroswap Thank you for this explanation. I understood now

  • @gurbakshsingh152
    @gurbakshsingh152 Před 3 lety +2

    Bro, do you know how we can allocate more RAM and CPU to make the HyperMesh Analysis run fast? Because I have access to High Performance Computer which has 32 CPU's and 128GB RAM.
    Thanks and looking forwards to your reply soon.

    • @Aeroswap
      @Aeroswap  Před 3 lety +2

      Hi Gurbaksh,
      You use multiple cores to run an analysis faster. This can be done by specifying the below command in options field before launching the solver-
      "-nt "
      I hope this helps!

    • @gurbakshsingh152
      @gurbakshsingh152 Před 3 lety +2

      @@Aeroswap There is already a command written by default in the options box "-optskip". Should I erase this and then input "-nt" ? or Should I put "-optskip, -nt" ?

    • @Aeroswap
      @Aeroswap  Před 3 lety +2

      -optiskip means the solver will perform the analysis and skip the optimization. As this is just an analysis and not optimization, you can keep it or erase it. Both is okay.

    • @gurbakshsingh152
      @gurbakshsingh152 Před 3 lety +1

      @@Aeroswap Thanks for letting me know what -optiskip means, I wasn't aware before. But unfortunately, when I am giving it a go I am not getting the .mvw file which I usually use to get. Also, I am not able to see the HyperMesh Analysis Progress window while following this approach.

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Alright. Try entering '-analysis' and run again. See how it goes!

  • @ashishdevasia7944
    @ashishdevasia7944 Před 3 lety +1

    please make a video on Transient Structural Analysis

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Hi Ashish,
      A detailed tutorial about transient structural analysis has already been posted. You can find it in the 'Optistruct Tutorials' playlist of this channel.

  • @saimadhav7604
    @saimadhav7604 Před 3 lety +1

    Hello,
    Iam trying to important stp file in hypermesh. while importing the file iam facing error, called "segmentation error". Please help me to solve this problem

    • @saimadhav7604
      @saimadhav7604 Před 3 lety +1

      This is stp file once check bro

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Please make sure that all import settings are kept on their default values. The default setting work best for STEP/STP import.

    • @saimadhav7604
      @saimadhav7604 Před 3 lety

      I imported by default only in stp so. I got this "segmentation error"

  • @yatikshah4255
    @yatikshah4255 Před 2 lety

    sir, while importing this geometry error is coming the file specified is not a hypermesh database

  • @saivijay5626
    @saivijay5626 Před 3 lety +1

    bro make a video Axisymmetry using Linear Static Analysis

    • @Aeroswap
      @Aeroswap  Před 3 lety +2

      Thanks for the suggestion. I will work on this topic soon!

  • @atharvakate5165
    @atharvakate5165 Před 3 lety +1

    I saw your composite tutorial but can u make another one with a more complicated structure .......is there anyway I can contact u ?

    • @Aeroswap
      @Aeroswap  Před 3 lety +2

      Hi Atharva,
      My email address is given in the 'About' section of this channel. Feel free to contact me via email.
      Thanks.

    • @atharvakate5165
      @atharvakate5165 Před 3 lety +1

      @@Aeroswap what can we do to see flux and temperature gradient ??

    • @Aeroswap
      @Aeroswap  Před 3 lety +2

      This can be done by selecting 'Flux' option in global output request card.

  • @tuanvan4624
    @tuanvan4624 Před 3 lety +1

    Hi sir i'm using hyperworks 2019, I did as you instructed but i got an error '' *** See next message about line 182288 from file:
    D:/hyperwork/OptiStruct/heat_themal/transient_themal.fem
    "DLOAD 10 1.0 8 1.0 9"

    *** ERROR # 1000 *** in the input data:
    Incorrect data in field # 3.'' can you help me explain this error? thank sir

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Hi Tuan,
      Looks like you have missed out on some step in the setup process. Please watch the tutorial carefully and follow every step. It will resolve the error.

    • @tuanvan4624
      @tuanvan4624 Před 3 lety +1

      Hi sir,
      I watched it and did it again but it still have the same error as above. Can i give you my file to you check this error ? thanks sir

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      Check your DLOAD card. Make sure that S field is set to 1.

    • @tuanvan4624
      @tuanvan4624 Před 3 lety +1

      @@Aeroswap yes sir field S is 1

    • @Aeroswap
      @Aeroswap  Před 3 lety +1

      The error message states that something is not correctly defined in the DLOAD. Please check all scale factor values. Also check whether you have assigned the DLOAD in correct field in the loadstep.