How to Check AVR in Generator ? How to Bypass AVR, Generator AVR ko kese check karay?? (URDU HINDI)
Vložit
- čas přidán 19. 07. 2020
- #avr #voltageregulator #voltage #generator #alternator
Generator AVR testing proceudre explained in urdu , hindi.
Watch more videos about Generator and AVR in Urdu/Hindi
AVR How it works ?
• Generator AVR in Urdu,...
Generator in Hindi / Urdu
• Generator Basics in Ur...
Excitation in Generator
• What is Excitation ? E...
CAT Generator
• How to Calibrate Engin...
3 phase alternator hindi urdu
• 3 Phase Alternator URD...
زبردست شاہ جی بہت اچھا کام ہے نئے آنے والے لوگوں کو بہت فائدہ ہو گا اس سے
Masha Allah... asad bhai aapne jo topic ka silsila shuru kiye hai wah lajawb hai aor yakeen jane is muttaliq mai khud aapko kahna chahta tha. Allah aapko kamiyabi de..aamin..🤲🤲🤲
Aameen😊
Masha allah Apke samjhane ka andaz bhot acha he
You are giving absolutely useful information. I like your videos. Thanks Subscribed.
Bahut achha explain kiya sir aapne... Thank you sir
Salam, Asad sir hamra pas ek generator hai volvo ka 440KVA os ma alternator overloaded fault ata hai or generator shutdown ho jata hai. Mccb trip ho jati hai.
@@abidwaheedkhattak3309 AQ@
thank you Brother may Allah bless you all the time, your all videos is very informative and useful for me... thanks and waiting for another new video
Very informative sir appreciate
Allah ilm me izafa farmay
Assalamualaikum vai.. I like your videos about cat engine....love from Bangladesh
The best Explanation thanks 👍
🌹 *Walaikum Assalam* 🌹
Thanks...sir good explain
👍👍thnx.
हम avr के तरह ॲटोमॅटीकली सेंन्स करके व्होल्टेज व्हेरीएट कर नही सकते.. फिर भी ग्रेट.
यह एक अस्थायी तरीका है
Very helpful 👍
Appreciated
Nicely explained...
Good information 👍😊
Sir koi live practical b kr k dekho.
Good explanation sir
Keep watching
Thanks Alot Sir ❤
Awesome video nya 👍👍👍
Masha allah 👍✌
Thank you sir
Selamın Aleyküm. I am writing you from Turkey. What you are saying is very valuable but I do not understand My request is to add subtitles. This will help us a lot.
Very nice.
Mashallah sir g .....
Masha,Allah
Very nice video
Thank you nice job ,do you have procuder to perfume this Demagnetization time constant and stator residual voltage after automatic demagnetization plesa
good information
excelant
Dear please portable generator set k stator winding and field winding,connecton and output wire pa B detail vidio upload Kar den.
Msaha allah
aik vedio bana dain deif controller k kia kia kaam kr sakty hain
very nice
Masha Allah
Thank you
Great
Nice sir
Nice video
Please explain about generator protection
Nice ❤️
Hello. congratulations for the videos. could you activate the subtitle translator function from youtube? For your videos the function is disabled. thanks.
Very good
Asad bhai masha allah.men ne pak made 25 amp AVR k centre point js pr amomn ..G ya R lkha hota hy k bary men pocha tha..2nd honda k 5 kva ka gen k ..Digital AVR k bary men video bnain agr ap what's up no den to men photo send kr dun
asad89electrical@gmail.com
ispe pic send krain me try karunga
good video
asad bhai diesel denerator kai ignition switch kai baray mein batai please
Good sir but askely potentiometer ketne Watt ka hona jahey
Vry niceeee
Sir voltage flutuate hone ka kya karan hai problem kisme hai
Hello sir ek dikkat ho Rhi h DG generator kuch time se 240V le leta h fir 9V Ho jata hai... Drop. Ho raha h.. Kuch help. Kar dijiye please
I face this problem today
Kya ham excitor field me ham 12volt baitri se direct saply de sakte hai
czcams.com/video/2y8fwJePIaU/video.html&pp=gAQB
Agar ham new avr lagate hai uske bawjud 220volt na de tokya karenge k 220 volt hame mil jae
Roll of parmanent north and south pole magnet in use of 12volt exider
Hi sir asad, in potentiometer how to connect in 3 pin, thanks
czcams.com/video/RX7TJ9-j0oQ/video.html
Kya hum CAT G3516B pey ye try kursaktey hain aur plz potentiometer ki rating bhi Bata dain
Kar sakty hen. Potentiometer 10k ohms
@@AsadElectrical thanks .last night problem ai thi. But CDVR was found faulty. I replaced it with KATO after slight modification
Sir Excitor field main humne DC Diya Avr ke jariye Aur excitor rotor main DC hi induced hoga kya aur fir rectifier ke jariye AC main change ho kar stator ko jaata hai kya
Hi. Me Excitation aur AVR ki videos ka link derha hun ap ye videos dekh lain apka concept clear hojayega. Excitor rotor me AC produce hoti he.
czcams.com/video/b8STzOaTyPE/video.html
czcams.com/video/2y8fwJePIaU/video.html
Kya Avr bhi exciter field ko about 12v dc deta he??
Nhi. Depend karta he generator model aur AVR excitation voltage range par. 40 vdc tak bhi hotay hen dc volt.
Aor baitri se jab ham conekt karenge potenso mitar to kitne no pe kar k 12volt ka saply denge ac volteg ya dc voltej pe denge
Ok
Aceehi. Elm. Sikay beta. Allah Hafiz. Zazay. Kharde. Allah
Avr dc out deta h to exciter me dc field generate hogi. Phir us ko main rotor me dene k liye ac me convert karna padega n
Wo khud convert hoti he rotating rectifiers ke zarye. Sirf Excitor field ko DC supply deni hoti he baki system internally hota he.
Hello sir.... Sx460 avr ki jagah as440 avr replace kar sakte hai kya?
If connection is same then no problem
Good brother pls one help i need i give positive negative opposite direction how to rectifier pls my friend
No problem if you connect positive & negative in reverse direction
Thank you brother
You have a good video but who does not speak your languange can not understand you, please just make it in English, to internationalize your videos.
I add my voice to this
Sir dc gernatar wali ractifir palate ac gernatar ma ractifir bridage ke guga kasy istamal ho ge
AC generator ki rectifier rating different hoti he
Dg set me avr multimeter se kaise check karna hai
A sad bahi 150 kva cumins ka alternator ha usko jabh avr lagayin tu main rotar heat hojata ha.our agar usko 12 volts battery k sath connect Karin tu voltage 500 se ziada hojatay hai
Winding Megger test karna prega
Sir my bike have self excited (12 coil dc 3 phase alternator) it's using mechanical energy to electrical . Sir can I excite the coil with 12v battery without mechanical energy using . Help me sir 🙂
actually i dont get your point. you can excite with 12v battery if your coil is need just 12vdc without any regulation
Haa sir it's a 3 phase alternator (self excited ) but I have want to excite that with battery 12 v . Without kicking the bike
Liyanas vlog2
Sir what will happen if we bypass avr by two methods
1. We provide 12 volts to avr instead of potentiometer.
2. First we start gen without load, than after constant rpm we instantly connect positive terminal to avr ....?
if you want to test Avr so you can give battery supply for few seconds just to mae sure your winding and rectifier circuit is good or not. but if you want to run generator on load than you will need potentiometer for maintain voltage at a constant level
Aslamoalaikum sir apki mail id kiya hai ??
sir can i ask what's the value of the potentiometer?
10 kilo ohms is good
@@AsadElectrical thanks sir
Exciter ko f1f2 ko 12volts ki supply ko kitni der tak dena chahiye, jab volts produce na Kare to??
Touch karte hi voltage barhna chahye
#Fuel Rail pressure, #wrn engine waring, sd engine shutdown, why does this Alam in diesel engine, Sir?
السلام علیکم یہ جو دو تار ہے F1 F2 اگر ان پہ لکھا نہ ہو اور کونسی گرم ہے چیک کرنے کا طریقہ نوید
Potensi mitar kaisa hota hai
Sir Agar voltage up down ho raha ho to us ko kesy tek keya jay
Sir cat generator main oip pressure kpa alarm aarha hai aur yen screen show kr rha h ******
Sir sensing voltage 5 volt hai to kya avr work karega
Karna chahye
After 12vdc input in exciter at rated 1500 rpm . how much will ac voltage ouput .
Its depend on Generator Model / capacity / brand etc.
Sir lvm paa bola tha
Sir can we connect single 4-20 ma to 2 sources?(i mean from single 4-20ma can we run 2things?)
what do you meant by ma
@@AsadElectrical mili amp
I want to from 2 sources from plc 4-20 mA output signal,one autuator and second is vfd
@@uzairasif2475 yes you can connect in parallel
@@AsadElectrical can you share the diagram,and in parallel current drop?
Sir please explain how to meggar allternaror, what connection to remove?
czcams.com/video/VjvAlWlDcgk/video.html
czcams.com/video/i4bGcycMMGI/video.html
Sir
L-L 403v. 220v. 80v
Need solutions
Sir,
DG 3ghanta load condition mai chalta tha phir,jab band karke 25 mins ke baad chalaya achanak battery blast ki,esa kiun hua,uska karan aur kya kya chek karna hai.....
czcams.com/video/S7MenuBK980/video.html
Asad bhai Crompton generators power nahi a raha Hai booster type Waka sare Winding theek Hai meter se any idea about to find problem iam motor rewinder
winding theek he to rectifier assembly aur AVR check karain
Can I ask any doubts about generators I can do anything with motors but I don't have much experience in generators to rectify problem
@@arshadbasha1504 yes you can
Jai shri 🙏ram
Sar Mere generator ke AVR ke cytopoint per 12 volt dc touch karne se a voltage Aana Shuru Ho Jaati Hain Lekin vaise a ya voltage Nahin uthata iska kya masla ho sakta hai
Avr ka msla hosakta he
asad bhai avr ki input par kitnay volt honay chahiay ac aur output dc kitnay honay chahiay
Avr model k hisab se alag alag hotay hen. kuch k input volt 110 kuch k 220 aur 400. aur output dc voltage fix nhi hotay load k hisab se km zada hotay hen ye generator ki nameplat par likhay hotay hen maximum output excitation voltage
OK jazakallah
agar f1 aur f2 wire change ho jain avr par to kia problem a sakti hah qk wires par tag nahi hain
excitation loss hosakta he lekin koi msla nhi he.
asad bhai avr meinay aj bypass karkay chalaya hai external voltage diay hain 23.5 volt battery say to 437 volt arahay hain avr ko meinay alag say voltage diay hain 220 wo output 128 volt day raha hai variable say na kam ho rahay hain na ziada
Potentiometer ke bina direct 12v डीसी de to kya theek he
desaktay hen just for testing purpose
what is the Choke coil on Neutral, what is use the Choke coil
how to make the Choke coil
Ok noted
Please share the detail
Sir 30 kva genrator ka AVR ka fuse baar baar ud raha hai .... Avr ko change kiya fir bhi fuse uda raha hai.... Kya fault ho sakta hai
Excitor Field ki winding check karain. Short to ground hogi ya uski coil short hogi. ya Excitor k wire short hongay
Bhai jaan dg current de nehi raha
Voltage properly nahi aateto
Voltage up down hote hai
Kabhi thik chalta kabhi voltege un belens hote hai to hame sajeshan kare
czcams.com/video/uTltFBICAnc/video.html
Please voltage 400 but single showing no voltage
380 volt ka dg hai woh sirf 200 volt nikaal raha h battry se check karne par aisa q horaha h????
Kholer sdmo 16 cylinder generator, minimum voltage fault(27), how to solve
Please check this video:
czcams.com/video/uTltFBICAnc/video.html
अगर हम एक्साईटर पर ब्याटरी उल्टा कनेक्सन कर दिया तो क्या होगा ? और फिर सुल्टा करके दिया तो एक्साईटर फिर काम करेगा ? कृपया जवाफ दिजिएगा ।
Excitor will work on both reverse & normal connection. Only residual magnet can be loss
@@AsadElectrical जवाफ के लिए धन्यबाद ।
६०० केभिए का जेनेरेटरका AVR बदल्ने से ५०० भोल्ट तक जाकर AVR का फ्युज उड जाता है एक्साईटर फिल्ड वाईन्डिंगका मेगर टेष्ट और मल्टीमिटर से वाईन्डिंग कन्टिन्युटी सब ठिक है और डायड के साथ फ्युज भि ठिक है । ईसका क्या कारण हो सकता है ।
Dg fail to start show over frequency delay .
Sar aapane bahut zabardast video banaya hai mujhe bahut pasand hai sir ap ka WhatsApp number kya hai please send kro