Globe valve Vs Balancing valve | HVAC | in Urdu/Hindi

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • Question asked about HVAC that "What is the difference between Globe valve and Balancing Valve?" I have answered about Globe valve Vs Balancing valve and explained this with examples.
    This is an HVAC System questions and answers video session in Urdu/Hindi language. It is basic learning detailed information about new or fresh engineers or new technical field persons. It is also important for HVAC / MEP technical staff to leaning points of view. Here sharing my experience and knowledge that will be helpful to learn & grow for Engineers & Technical staff. If you found anything which is inappropriate then convey it in the comments for my information and rectification in the future.
    You can watch my Q&A videos through the following links:
    1. How airlock and water reduced in pipes?
    Video link: • How airlock and water ...
    2. Where PRV is required as per Pressure in Firefighting System?
    Video link: • Where PRV is required ...
    3. Difference Between Pressure Relief & Pressure Safety Valve
    Video link: • Difference Between Pre...
    4. Difference Between Pressure Reducing & Pressure Restricting Valve
    Video link: • Difference Between Pre...
    5. Converting Pump Head to Pressure or Vise Versa
    Video link: • Converting Pump Head t...
    #TanweerAhmed #HVAC #Valve #GlobeValve #Balancing Valve #MEP #Engineering
    = YOU CAN FOLLOW ME ON SOCIAL MEDIA =
    WEBSITE: engineertanwee...
    FACEBOOK: web.facebook.c...
    INSTAGRAM: / tanweersethar
    LINKEDIN: / tanweer-ahmed-00142631
    CZcams: / tanweerahmed
    TIKTOK: vm.tiktok.com/...
    TELEGRAM GROUP: t.me/hvacmepenggg

Komentáře • 36

  • @danishkhadim4048
    @danishkhadim4048 Před 16 dny +1

    In an hydronic HVAC system with a 2-pipe direct return setup, we use balancing valves to make sure each machine gets the right amount of water. Balancing valves are installed at the outlet and manually set to have desired flow rate (GPM). Once adjusted, the balancing valve stays in place to ensure each machine gets only the water it needs. Additionally, an automatic control valve, with the help of a thermostat in the air conditioning space, adjusts the flow of water based on air conditioning needs.
    Balancing Valve will not automatically adjust flow rate , we manually adjust balancing valve to setup the flow we want to have in that machine .

  • @ahsankhan8494
    @ahsankhan8494 Před 2 měsíci +1

    Very good information

  • @NafeesChohan773
    @NafeesChohan773 Před 3 měsíci

    JazakAllah Khairah Brother 🥰

  • @shadabrehman709
    @shadabrehman709 Před 2 lety +1

    Very good information.

  • @muhammadai4160
    @muhammadai4160 Před rokem +1

    Salam alaikum excellent channel Mr ❣️

  • @moideenyousaf3757
    @moideenyousaf3757 Před 3 lety +2

    👍👍👍

  • @rashidkhan8783
    @rashidkhan8783 Před 3 lety +1

    Wa ALAKUM SALAM very nice

  • @mohammedsaadsaqibareeba9889

    Assalmalikum tanveer sab App bahut acchay vedioes banatay hai MEP sector may Thank you , DRV why its called double regulating valve ,is it double means working in cold and hot watwer conditions, pls explain and make one vedoie on how to balance at site

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      W.Salam and thanks
      Insha'Allah will prepare video on it

  • @indiantraveller194
    @indiantraveller194 Před rokem +1

    Bhai jaan category kaun sa select kare channel ka hvac banana hai please batayein

  • @taqirkan7712
    @taqirkan7712 Před rokem +1

    Assalam O Allikum Sir...let say if we have 4 AHUs at 700 TR operating at 75% load. Let say, if out of 4 AHUs, 2 are turned off for maintainace aand their balancing valves are turned off as well and other 2 are running at the same load, then where will the remaining chilled water be going which was providing chilled water to AHUs which are tunred off dor maintainace?

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      W.Salam, I have explained in video. However, if constant flow system then 3-way valves are installed with AHUs and water bypass from 3-ways. If variable water system is installed then 2-way installed at AHUs and pump's will be VFD drive and also bypass in chiller plant room.

  • @ammarkhan2851
    @ammarkhan2851 Před 3 lety +1

    Sir plz uplod all types of plumbing drawing reading

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Insha'Allah will upload after prepare video

  • @user-gq4pz7gd7o
    @user-gq4pz7gd7o Před 3 lety +1

    3vav k bary main information dien sir

  • @jafarkasim5600
    @jafarkasim5600 Před 3 lety +1

    Kisi ko kuc v kaam na malum ho us k ley suro se kuc batay

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      My all videos are for new Engineers or students for learners

  • @jitendrasinghbhadoriya3980

    Sir why cwt weight is Half of capacity+empty car weight