Trane American Standard Symbio 700 App Configuration and Navigation

Sdílet
Vložit
  • čas přidán 27. 08. 2024
  • Brief overview of the Symbio 700 app and setting up common parameters.

Komentáře • 33

  • @oidodsonido4373
    @oidodsonido4373 Před 21 dnem +1

    Thank you to every tech out there that takes their time to teach a little bit of knowledge out here on you tube your time and experience it’s much appreciated.

  • @unclemonster48
    @unclemonster48 Před 2 lety +1

    Man thank you for this vid! I’ve been wrenching on chillers for the past 9 years and have been left behind in the light commercial equip. Just got sent to install a 20 ton trane split heat pump. I opened the condenser and stared at the new Symbio board like a hog staring at a wrist watch. No more rtrm boards huh? I like this new feature and thanks for the quick run down of the app.

    • @Hvacoffroad
      @Hvacoffroad  Před 2 lety +1

      Yep, rtrm are going away and will soon be replaced in the RTUs also. I wasn’t sure if I liked the symbio system, but after I gave it a shot, I really like the features.

  • @texasstarniles5
    @texasstarniles5 Před 6 měsíci +1

    Thank you very much for your great Video !!!

  • @AnttiToukolehto
    @AnttiToukolehto Před 5 měsíci

    I got 6 ton symbio CU and 7.5 ton odyssey AHU with VFD blower and i got error code 83 on the yellow display, CU starts but I cant get the damn blower to start. Trane wont help me because i havent taken the class, any idea what is happening? I need help, this thing is driving me nuts.

  • @frankhartley6777
    @frankhartley6777 Před 2 lety +1

    I also my heater kit has 2 wires which the Airhandler has 3 wire hook up?

    • @Hvacoffroad
      @Hvacoffroad  Před 2 lety +1

      You have a single stage heater. (2 wires). Connect it to the plug on the right.

  • @filibertomarmolejo1482
    @filibertomarmolejo1482 Před 2 měsíci

    Can we check refrigerant pressures on the app?

    • @Hvacoffroad
      @Hvacoffroad  Před 2 měsíci

      I wish we could. But unfortunately, they didn't add pressure transducers to these systems, so we can't.

  • @jevonhoward
    @jevonhoward Před rokem

    Can I put backup on a laptop that has Tracer Tu software?

  • @samacrepait4053
    @samacrepait4053 Před 11 měsíci

    Got question, I install split system symbio 700 I ran wiring the same way you did and my blower motor did not came on got a warning 017 code can you help please?

    • @Hvacoffroad
      @Hvacoffroad  Před 11 měsíci

      Do you have a VFD air handler? If so, you'll need to run additional wires to get the blower to operate. This video was for a single speed blower.

  • @2purplemartin1
    @2purplemartin1 Před 11 měsíci

    I’m about to change a 10 ton condenser that currently the older version of this. It’s a 2 stage straight cool. Question is can I run the existing control wires off the old TTA120 to the thermostat terminals on the new symbio controller and configure through blue tooth and it run? Or do I need to jump wires around to get it up and running. Supposed to do the job new week.

    • @Hvacoffroad
      @Hvacoffroad  Před 11 měsíci

      Are you changing out the condenser only? If so, then the wiring is fundamentally the same. Except there is no need to run the twisted shielded wires, because you won't have a board to communicate with on the inside.
      J21 plug on the symbio condenser is all input or command signals. You really only need the blower output on J18 if you are using an E-stop signal for a smoke detector or some other device.

    • @2purplemartin1
      @2purplemartin1 Před 11 měsíci

      @@Hvacoffroad Yeah just the condenser that has the reliatel controls. I’m assuming that what the old one has anyways. So i would still need to configure it through the app though correct? Or should it be just plug and play? It’s a straight cool with electric heat only. Thanks for the reply, find this info is pretty vague sometimes.

    • @Hvacoffroad
      @Hvacoffroad  Před 11 měsíci

      @@2purplemartin1 most of the condenser settings will already be configured from factory. You’ll have to tell the app what kind of indoor unit, single speed, blower type ect. Make sure it’s configured for a thermostat or BAS, whichever one you are using and remove the filter runtime reminder. I’d check all the settings to be safe.

    • @2purplemartin1
      @2purplemartin1 Před 11 měsíci

      @@Hvacoffroad We installed that unit to a different airhandler today and it had two Rib relays for the first and second stage AC condenser. You’re right, I didn’t even go into the Symbio controller and it fired right up and staged too. Thanks for the help again!!

  • @ckennedy309
    @ckennedy309 Před 6 měsíci

    So what to do with a Z pairing?

    • @Hvacoffroad
      @Hvacoffroad  Před 6 měsíci

      www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&cad=rja&uact=8&ved=2ahUKEwj11LjLwbqEAxUY48kDHdWxCUwQFnoECAwQAQ&url=https%3A%2F%2Felibrary.tranetechnologies.com%2Fpublic%2Fpages%2Fviewers%2Fpdf%3FprojectKey%3D5fdb788a8fd84100018bb855%26itemKey%3D6291317de94b0d229f74dbbc&usg=AOvVaw2wkCM_XV5LlUIL4n6EqZcP&opi=89978449
      This may help. Not for vfd configurations with 2 condensers.

  • @johnfarris8395
    @johnfarris8395 Před 2 lety

    I have a dual circuit 20 ton Symbio condenser paired with a constant volume Symbio air handler. No indoor options/heat board. Conventional t stat. Why would both circuits energize with a call from only Y1? I have 2 exact same setups and they both do it. I changed in the app from BAS to conventional thermostat.

    • @Hvacoffroad
      @Hvacoffroad  Před 2 lety +1

      Is it a heat pump or cooling only? Did you select “staged” under the configuration and specify two stages?

    • @Alex-bk4vc
      @Alex-bk4vc Před 2 lety

      Did you ever figure out why it was doing that and how to fix it? Because I'm having the same issue.

  • @frankhartley6777
    @frankhartley6777 Před 2 lety

    The paperwork with unit doesn’t show 5 or 7 on the dial switch at Airhandler that you recommended for 5 and 7

    • @Hvacoffroad
      @Hvacoffroad  Před 2 lety +1

      Yes you need to address it for 5, &
      7 if you are using it for electric heat.

  • @ryanford6696
    @ryanford6696 Před 3 lety +1

    What if you Airhandler is Not Symbio!?!?

    • @Hvacoffroad
      @Hvacoffroad  Před 3 lety

      It would depend on the air handler that you are using. You would still send the g signal out of J18-1 to the blower signal on the air handler. I you need 24v hot and common, that would come from J15-1,2. Then, if you need y's, w's or an o, you would get that signal from j21 on the condenser.

  • @Angelo-yj7bp
    @Angelo-yj7bp Před rokem

    how to connect an overflow switch

    • @Hvacoffroad
      @Hvacoffroad  Před rokem

      You can break red to the thermostat or use the e-stop terminals on the outdoor. Just depends on how many wires you have available.

  • @samacrepait4053
    @samacrepait4053 Před 11 měsíci

    by the way its a 10 tons

  • @thomaswaldorf2829
    @thomaswaldorf2829 Před rokem

    Arbitration method request? seriously? ...