How to cam a Pentair valve actuator

Sdílet
Vložit
  • čas přidán 4. 06. 2020
  • This video demonstrates the different modes and how to set each of them up. Including a popular spillover mode for your enjoyment. If you have questions contact us through our website at:
    www.poolspecialists.com/
  • Jak na to + styl

Komentáře • 11

  • @cubmixit
    @cubmixit Před rokem +2

    Installed a new actuator and couldn’t figure out how to set it up until this video. Cam adjustment and now works perfectly!Thank you!

  • @LordGreybeardsChannelofWisdom
    @LordGreybeardsChannelofWisdom Před 10 měsíci

    I had a valve that wasn't shutting off. The motor kept running. I tested the switch and it seemed to work, but the stop had moved. I wasn't sure if they were adjustable. This fixed the motor-run issue.

  • @farukbatakci2000
    @farukbatakci2000 Před rokem

    Great video! Thank you!

  • @petervellutini7403
    @petervellutini7403 Před 7 měsíci

    Thank you - great video.

  • @barrymccockinner5548
    @barrymccockinner5548 Před 2 lety

    Thanks man, saved my butt

  • @blakewill1933
    @blakewill1933 Před 3 lety

    Thanks for the info...

  • @greginfla5324
    @greginfla5324 Před rokem

    Thanks for the video. I have the same actuators, but the opposite problem. The pool builder set the return valve to have partial flow to the spa when in pool mode. This causes constant acid loss and weekly acid feedings to lower the always rising ph (from the aeration of the water). I need to undo that change. It looks like I just do the opposite rotation that you did. One more question: what is the significance of the two black posts? In your video, the valve is set for L90 R90, but mine is set at the 180 holes. I am wondering if I need to move those black pegs.

  • @mohammedkhan3338
    @mohammedkhan3338 Před rokem

    Thanks

  • @SUBZEROUKS
    @SUBZEROUKS Před 8 měsíci

    Top Cam is Clockwise and lower cam is counter clockwise