How to Test & Fix Blower Fan If It’s the Not Resistor or Motor GMC Canyon, Chevy Colorado, Isuzu

Sdílet
Vložit
  • čas přidán 27. 08. 2024

Komentáře • 125

  • @EasyHotStuff
    @EasyHotStuff Před rokem +13

    started with the same problem here, 08 chevy colorado fan stopped blowing on setting 3 and then the rest eventually stopped. had a burn mark on my resistor wiring harness just like yours. replaced that and it didn't fix it. took out the blower and tested it and it was fine. IT ENDED UP BEING A BAD CONNECTION IN THE WIRING HARNESS BEHIND THE GLOVEBOX. I couldn't get the harness open so I cut the brown wire on both sides of the harness and connected them with a wire nut and boom, its blowing like new! (wish I hadn't spent so long trying to get out that rear screw to take the blower out 😵‍💫)

    • @WasherDryerMoney
      @WasherDryerMoney  Před rokem

      Awesome.

    • @papicruz3631
      @papicruz3631 Před 7 měsíci +2

      You ain’t kidding about that rear screw. It’s no joke! I ended up not taking it out and plugged in some pig tails I had and used alligator clips to connect to the pig tails. The motor works. I believe I have the same problem as you man. I’m going to check the connector behind the glove box tomorrow. I checked all my grounds, (even the one under the air box) changed the resistor and burnt harness and still nothing. I will update tomorrow.

    • @papicruz3631
      @papicruz3631 Před 7 měsíci +3

      UPDATE: It was the connector behind the glove box. The brown wire (power wire) connector was burnt. I cut and spliced it together so there will no longer be an issue.

  • @robertclabaugh2692
    @robertclabaugh2692 Před 11 dny

    It’s now August of 2024 and u just saved a Colorado with 305k miles on it and now blowing full air again haha. Thanks!

  • @TylerBledsoe
    @TylerBledsoe Před rokem +6

    Man I love CZcams University. Thank you for making this video!

  • @nickboutin857
    @nickboutin857 Před 9 měsíci +1

    “Beep” with multimeter=Technical term is continuity. Best video I found on this issue! The Blower went on the colorado my family has. Wondering if it’s just the motor but this answered all my questions. Great work sir! And greatly appreciated because you did save me a lot of time!

  • @MrTrueshoe
    @MrTrueshoe Před rokem +3

    Having similar issues suddenly … my guess is the answer is in this video … thank you very much … just saved me a lot of time in quick 5 min video!

  • @alexanderspenser4960
    @alexanderspenser4960 Před 3 lety +3

    Thanks for the video; I'm there and doing that. '08 Outlook, two weeks, still can't find the connection failure, but like you, changed the resistor and should have known that the high should be working. Tested head unit with voltage change on the grey black wire, fuses are ok, swapped relays, even pulled the under the hood fuse terminal looking for critter violations. All good. Wired blower to battery and its good. Rear blower works fine. Out of frustration, went by the friendly Chevy store, who confirmed pull the dash and chase the red black wire, that is to stay hot. Swapped resistor, blower wire and blower to my 2011 Sierra, work like it should. Man, I dont wanna take a dash apart.

  • @Dusty_Bottoms_
    @Dusty_Bottoms_ Před 2 lety +4

    Thank you for a very good video!
    I went through and checked everything.....
    Fuses, relays, replaced resistor & plug connector, checked for continuity, fan directly on 12V...... everything was fine
    Still no fan.
    Had 12V at the fan plug harness, but when I touched the plug to the fan motor the voltage dropped to 0.00V.
    Scratching my head....
    Finally checked the passenger side grounding block, looked fine but there was a less than 100% connection. Opened up the grounding block, lightly brushed the connections, reassembled.
    And finally the fan worked as it should.
    Not the first time the grounding block caused intermittent / mystery problems.

    • @WasherDryerMoney
      @WasherDryerMoney  Před 2 lety +2

      Yeah when I first got that truck I had issues with that same grounding area. I took all the wires off and made a better ground terminal bolted to the side and never had issues with it again.

    • @opera93
      @opera93 Před 2 lety

      Thanks, note my FAN problems, though holding off on replacing original FAN Motor; as Shop suggested…FOUR POINT RESISTOR replacement SEEMS to cure ((* in absence of severe *& frequent testing!)…..BUT, the ENGINE CRANK//no start…..is irritating: Interestingly, only twice last several months::: always seems to start after:** @ “after”ten minutes .. Also, a few trials of you Tubers , &/Various PASSLOCK, resetting/Procedures (with ENGINE crank// *NO STARTS) seemed to be of NO help……..

    • @Dusty_Bottoms_
      @Dusty_Bottoms_ Před 2 lety +1

      @@opera93
      If you're having passlock issues, I suggest having a tuner dissable the system. It's never a problem again.

    • @opera93
      @opera93 Před 2 lety

      @@Dusty_Bottoms_ super Thanks….. May try that if simple to bypass ,or disable…”. “Crank/ no start “: been irritating a couple times over the years.. assume there is Valid Procedure for these!,,,,,,,,,,,,

  • @johnhenderson7094
    @johnhenderson7094 Před rokem +2

    Video is still saving Colorado owner’s today. Thanks man -06 Brown wire

  • @israelibarra2198
    @israelibarra2198 Před 3 dny

    Dude you saved me, thanks a million!!!!

  • @latourbrian
    @latourbrian Před měsícem

    Thank you so much for taking time to post this. My fan was working on all three speeds except high. The orange wire going through that connector behind the glove box was bad. Many thanks.

  • @damien5267
    @damien5267 Před rokem +1

    I have been searching for that short for a year thank you, I have an 11 Colorado i

  • @carmac1652
    @carmac1652 Před 3 lety +3

    My truck is doing this 4 time's I keep changing the resistor and it keeps burns out great information 👍🇨🇦

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety

      This problem was extremely aggravating. It took me hours to figure out what was going on.

  • @go-to-H2O
    @go-to-H2O Před 2 lety +3

    Thx for explaining this. I too had a burned out connector at the third position on the resistor, and after replacing it I still had no blower. I had power going to the blower, so I concluded that the blower was bad, pulled the blower out to find a fried connector at the blower. The connector was melted in and very difficult to remove. I cleaned the male connectors on the blower and it worked. I really wonder why the fuse didn’t blow. Thx again for your help.

  • @kabeefarms
    @kabeefarms Před rokem +2

    Your video helped me tonight, having the same problem but found out that I have lost the ground to the blower motor. Haven’t figured how I’m loosing my ground. Seems like I’m loosing it at the circuit board.

  • @evanthomasson8931
    @evanthomasson8931 Před 2 lety +3

    Thank you so much! For the past 6 months only 4 would work for me. And just two days ago i lost 4 too. So by my assumption (after learning from your video) I burnt up my wires and kept running it on 4 so the resistor blew. I knew it was a wiring thing, just had no clue where to start and I didn’t want to spend a week diagnosing.

    • @WasherDryerMoney
      @WasherDryerMoney  Před 2 lety

      Glad to help

    • @nicdamato6401
      @nicdamato6401 Před 2 lety

      I have this same problem right now where 4 only works, I haven’t really looked into it but now I know lol

  • @suzannehenkel962
    @suzannehenkel962 Před rokem +1

    Thank you! I have the exact same problem... will check this out tonight.

  • @jumpsouth1
    @jumpsouth1 Před měsícem

    Chedk where the ground wires are connected to the fender. They have paint behind the wire ground and has 4,5 wires connected to one spot. Clean the ground, and the blower resistor should work good,

  • @hisartisan1048
    @hisartisan1048 Před 18 dny

    you wer right, disconnected and put brown to brown and blower works great! only worry is that the wire on the blower side overheats. how can I keep that from happening?

  • @jlove3706
    @jlove3706 Před rokem +1

    Clean the ground with some sand paper on the passenger side too by the air filter box , is a small box works all the time when all 4 speed stop working

  • @NicholasTomlinPlus
    @NicholasTomlinPlus Před 2 lety

    Many thanks, I have this problem as all the relays and fuses work.. have to check your info and also an earth resistor near the air filter box.

  • @cathey821
    @cathey821 Před rokem +1

    Thank you you are a true merchant

    • @WasherDryerMoney
      @WasherDryerMoney  Před rokem +1

      No. I’m only to Appliance Repair guy.
      Just decided to post this video because it was so frustrating and difficult to find. I wanted someone else to be able to figure out the problem easier than I did.

  • @jmshssk2
    @jmshssk2 Před rokem

    Thanks bud. I'm gonna jumper that wire at the harness since the harness connectors won't separate.

  • @jeffflowers9647
    @jeffflowers9647 Před 2 lety +1

    Mine don't work at all. I got juice to the blower motor I even took the blower out an check it works fine. I checked the resistor beside the blower motor not really burnt getting juice there. All my fuses are good my relays are good only other thing I can think of and I ordered is the heater control switch. Hope it works after this. This truck is driving me nuts . I got to speed on 1 through 4 .

  • @bryanparker1273
    @bryanparker1273 Před rokem +2

    I replaced my resistor and my fan on my 2005 Chevy now fan speeds one through four work fine but speed number five shuts the system completely off. Any clue what’s causing this?

  • @mrbluehill1194
    @mrbluehill1194 Před rokem

    Having this problem now thanks I’ll check the wires in the morning

  • @robinschroeder2223
    @robinschroeder2223 Před 2 lety +1

    Thanks. My fan has 1-2-3 all on low speed with 4 still on high. Any Suggestions, Robin

  • @oliverbernal3316
    @oliverbernal3316 Před rokem +1

    I have a 2006 colorado 3.5 and 2 and 4 would work on the fan. Now none of them work and nothing blows out. I was thinking the blower motor went out but after watching this it might be something else. Any ideas ?

  • @Desertjoe789
    @Desertjoe789 Před 6 měsíci

    So you fixed the symptom. But what’s the cause? I’m so tired of changing resistors and fan motors on my Colorado, I’m not getting any younger. I have to do this almost once a year… 🤦🏻‍♂️

  • @jeffreychell3274
    @jeffreychell3274 Před 4 měsíci

    Was the plug damage at all because I’m having the same problem and I’ve done everything you’ve done except check connectivity so did you replace that wiring harness? What did you do?

  • @Killedby-Monty
    @Killedby-Monty Před 11 měsíci +1

    I recently just replaced my resistor and wire harness 2 days ago and it worked perfect all the levels of the ac was working then 1 day later when I turn on the ac it only works on high like full blast and not the outher settings? Can anyone help me please

  • @frankpage4461
    @frankpage4461 Před 2 lety

    Thanks - I had the same thing happen and your video helped!

  • @yvonneagundez1994
    @yvonneagundez1994 Před 2 lety +1

    This happen to me as well.
    I saw burn resistor and speed 3 was going on and off.
    I replaced the resistor and work fine up until 7 years later.
    The all speeds turn off, few days later turn on again, then all speeds go off.
    I look at the resistor it's not burn.
    But have not did any testing yet.
    I should start with fan motor with out removing it.

    • @WasherDryerMoney
      @WasherDryerMoney  Před 2 lety

      Definitely before you take the fan out check all the harnesses.

  • @user-fv5yp6dt5k
    @user-fv5yp6dt5k Před 9 měsíci

    Can you do a video on how to switch out the blower motor, which I assume is somewhere around the glove compartment? How do you find the blower motor?

  • @bartlettferguson494
    @bartlettferguson494 Před 2 lety +1

    What exactly are u connecting there alligator clip to, near the fuse box, a grounding screw?

    • @WasherDryerMoney
      @WasherDryerMoney  Před 2 lety +1

      It’s been a while since I made this video. Basically I’m starting at the fan fuse and working my way back to the fan one connection at a time until I find where the break is.

  • @andrewp3367
    @andrewp3367 Před 4 měsíci

    123 are out and on mine would that be same issue i thou g ht its was the consol itsself and replaced that and still same issue so now I'm out 60 bucks and time. 4 still works so its not like i have no air

    • @WasherDryerMoney
      @WasherDryerMoney  Před 4 měsíci

      I would first try replacing the speed control part that I talk about in the beginning. It’s a plug-in play. It will either work or it will not. Usually it does work. It worked on mine the first time it went out. After that I would do what I did in this video and try to track down a connection or ground problem. Good luck.

  • @Johnny-fd1fm
    @Johnny-fd1fm Před 3 lety +1

    Hi, thanks for your efforts, I am also going on the 4th replacement of the resistor. Seeing this video I am convinced that the problem I'm having is the same. Did you just cut into a hot line,run a new wire or replace the entire wiring harness? Thanks for any help.

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety

      I just cut the wire that was burned up and wire them together outside of the harness. I always solder and wire cap plus tape my connections.

    • @tyronekitchens4245
      @tyronekitchens4245 Před 3 lety +1

      @@WasherDryerMoney I have ground but no power.Fuse and relay is good.(94 Ford ranger)Change blower motor and resistor??

    • @MrPholding
      @MrPholding Před 2 lety +1

      My blower sounded like it was running on only 4 so I changed resistor/harness. Sounds like it runs on all setting but no air coming out. Is this what you had?

    • @WasherDryerMoney
      @WasherDryerMoney  Před 2 lety +1

      @@MrPholding mine would not come on at all. At one point it did have the common resistor going out problem I believe four would work and three but not one and two. I replace the resistor and it started working. Mine would just not run at all even after replacing the resistor. It was a burnt up wire in the wiring harness.

  • @supercracker4513
    @supercracker4513 Před 3 lety

    Thank you hopefully this will fix my problem and same me some time

  • @DWhitesWorld
    @DWhitesWorld Před rokem +1

    Hey I’m having this exact problem and I’m just a little confused on what you did that fixed it if you could describe it for me I would really appreciate it

    • @WasherDryerMoney
      @WasherDryerMoney  Před rokem +1

      I track down the bad connection. Mine was at the connector behind the glove box.

    • @DWhitesWorld
      @DWhitesWorld Před rokem

      @@WasherDryerMoney so did you change the connector and if so can you send me a link to that part I need or the name of it

    • @WasherDryerMoney
      @WasherDryerMoney  Před rokem +2

      @@DWhitesWorld when I found the connector behind the glove box, I could see when I unplugged it, one wire was burned, and slightly melted.
      That plug connected a lot of wires together and there was only one bad burn wire, so I cut it off that plug and wired it together off the plug.

    • @DWhitesWorld
      @DWhitesWorld Před rokem

      @@WasherDryerMoney ok bet

  • @megafusrodah
    @megafusrodah Před 3 lety +1

    So once you figured it out what did you do to fix it? Did you swap that wire harness? Im having the same issue and i think this may be it. Im going to check it tomorrow

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety +3

      I cut the wire that was burned inside of the harness and just attach them together with a wire nut and solder. it was just one wire that was the issue so I left the rest of the harness alone.

    • @megafusrodah
      @megafusrodah Před 3 lety +3

      @@WasherDryerMoney thanks bud. I got impatient and checked them all the dang wires are good. Looks like i might need a new blower. Fml

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety +3

      When you take the fan off you can put power directly to it from the battery to double-check that it doesn't just come on. If it does just come on it's not the fan.

  • @wickedlokz1849
    @wickedlokz1849 Před 7 měsíci

    Can you bypass the power wire

  • @angryedm4580
    @angryedm4580 Před 2 lety

    Awesome explanation

  • @robthestud2003
    @robthestud2003 Před 4 lety

    There is also a ground that usually gets bad contact by the intake box it has the word Delphi on it move it around it should turn on. The little black box is grounded to the fire wall

    • @WasherDryerMoney
      @WasherDryerMoney  Před 4 lety +1

      rob522 yes and I have fix that connection box before. When I first got this truck that was messing up all my tail lights. I can’t remember how I fixed it but I remember I over killed it.

  • @cliftonw1365
    @cliftonw1365 Před 2 lety +1

    I have an issue where the fans works sometimes and then doesn't work at all.

  • @nobueno8652
    @nobueno8652 Před 2 měsíci

    All my ac speeds work from 1-5 but I have an annoying clicking sound. You think it’s my blower motor?

    • @PlainsGaBoi
      @PlainsGaBoi Před 2 měsíci

      More than likely you have leaves inside the blower motor. Take it off and dump off the leaves. I had the same problem

  • @AGuysGarage
    @AGuysGarage Před 3 lety

    Thank you for the information thank you for posting and sharing for sure although when you got to the important part it was a little rushed in vague I felt like, but nevertheless I appreciate you sharing the information have a nice day

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety +2

      Thanks for the comment. I normally do very detailed videos on appliance repair. I have been trying to fix this truck issue all day and when I finally figured it out I just made a quick video in case someone else runs into the same problem. Should have made it more detailed but it was more of a last minute Quick video.

    • @opera93
      @opera93 Před 3 lety +1

      @@WasherDryerMoney thanks, really. See my “ fan problem” : interestingly , seems like FAN 1, 2 speeds may go off occasionally: NOT JUST 3-4 : I may attempt Reaistor Replacement….

    • @WasherDryerMoney
      @WasherDryerMoney  Před 2 lety +1

      @@opera93 definitely replace the resistor first that’s step one if it doesn’t solve the problem I would start looking at the wiring harnesses.

    • @opera93
      @opera93 Před 2 lety

      @@WasherDryerMoney thanks!, interestingly, I did replace “*FAN RESISTOR 4PLUG ( ORIELLY AUTOMPARTS,CHINESE)as CANYON wiring, Originalypresented two Plugs @50% blackened, & 10%Blackened //final two: & **fortunately, no,known FAN SHUT OFFS on any for four Speeds several months.. HOWEVER,the “” CRANK ENGINE , NO START” : happened twice last several month:: wait ten Minutes & start “:every TIME”!!! MILDLY irritating, as no apparent reason (* thougH several frequent starts/ short Drives “ May” induce CRANK/no start…( System PASSLOCK?.)….

  • @OscarGonzalez-py8by
    @OscarGonzalez-py8by Před rokem

    I have the same problem ,,tiene is the Brown wire in the back of the Glover department?

  • @johnhigh4214
    @johnhigh4214 Před 2 lety

    What model dmm are you using? I need to get one and I want one that beeps.

  • @JosephCompnotta
    @JosephCompnotta Před rokem +1

    Thanks, I have a 07 Gmc my blower comes run for a few hours and then stops. What would you check 1st? thanks

  • @ChristianPerez-xd8zq
    @ChristianPerez-xd8zq Před 2 lety

    What specifically did you end up fixing, what you did is whats wrong with i just dint know how to do it

  • @way2hard4me
    @way2hard4me Před 3 lety

    How does the white harness clip going to the blower release? I’m pulling the harness out and that last clip on the bottom faces away and I can’t see how to release it. Thanks

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety

      Wish I could tell you it’s just been too long since I did this repair. I can’t remember. I will say the harness that was burned up was extremely stuck together because it had melted plastic together.

  • @iamsain1969
    @iamsain1969 Před 2 lety

    My chevy colorado blower motor just started working intermitenly. i checked the fan motor, wss fine, replaced the resister, was fine, of course fuse was fine. I may check the relay next. Is it possible thats working intermitenly, or do you think its still a wiring issue?

    • @weaverfever55
      @weaverfever55 Před rokem +1

      I replaced the resistor I replace the fan work for a little while and now I have to hit the fan motor to get it to start I carry a hammer on the floorboard and use the wooden handle of the hammer good hit the fan motor and it will run every time I shut the truck off
      The fan will not work until struck with a blow

    • @iamsain1969
      @iamsain1969 Před rokem

      @@weaverfever55 I ended up replacing the fan motor, after the resistor, and I havent had any trouble since. been working fine. I decided my fan motor had a bad spot in the winding somewhere.

  • @Mike-iz9km
    @Mike-iz9km Před 2 lety

    Great tip!

  • @jonathanbarnard1862
    @jonathanbarnard1862 Před rokem

    What is that harness called?

  • @ngbay160
    @ngbay160 Před 2 lety

    I just replaced my resistor thinking that was it. Before it worked when it wanted to and would turn on when i hit a bump in the road so i replaced it. Now i get nothing. Harness to resistor looks good no burn marks. Ill have to check these fuses before i go buy a blower motor. 🤔

    • @Udi_lifts
      @Udi_lifts Před 2 lety +1

      Have you figured out what it is I also still have the same problem currently. Im still confused on how it just randomly turns on when I hit a bump

  • @desireeallen9835
    @desireeallen9835 Před 3 lety

    Thank you so much you saved me a lot of time and money

  • @PapaStuBlox
    @PapaStuBlox Před rokem

    2018 trax I've replaced the wires to the resistor, the resistor and the blower motor. It worked on all 4 speeds properly for about 8 minutes then everything stopped I'm getting no air at all. Anyone have suggestions? Thank you

    • @WasherDryerMoney
      @WasherDryerMoney  Před rokem

      Check all the wiring harnesses mine had one bad connection. It was pretty obvious.

  • @danecrenshaw1743
    @danecrenshaw1743 Před 15 dny

    How do I test my blower motor just the motor

  • @joelmeece1932
    @joelmeece1932 Před 3 lety

    I'm having the same problem I checked with a multimeter and it says the blower motor is getting voltage but it's still not turning on

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety +1

      Maybe the blower motor has gone out. I took mine off originally thinking that was what was wrong and wire it directly on the battery. It came right on so I knew that was not it.
      Be sure to unplug all the harnesses that I showed and make sure there’s no burn marks.

  • @briangibson6445
    @briangibson6445 Před rokem

    Thank you!!!!

  • @kanewaikiki6071
    @kanewaikiki6071 Před rokem

    Big help bro

  • @559mafiaboi
    @559mafiaboi Před 4 lety

    I have the same problem man and we put the blower new and the fuse new and I’m thinking his is the couse

  • @donleibensperger495
    @donleibensperger495 Před 3 lety +1

    I have a 2007 GMC canyon truck the

    • @donleibensperger495
      @donleibensperger495 Před 3 lety

      THAT the fan stopped working and found the resistor pack and redone all grounds and still no power need assistance please

  • @opera93
    @opera93 Před 3 lety

    Thanks, I have 2007/CANYON SL/ 4 CYL: just tying to fix : FAN shUts “OFF “ quickly @, “ speeds 3,4,generally;::: speeds 1,2 Work ….interestingly, thinking about it , seems like FAN speeds 1 & 2, , have gone Off , rarely last year or two,,,also….mildly irritating.. Anyways, real problem I have a :::: “ no *start, turns over perfect , no *check engine Light” come up occasionally:: seems to “ start “ peerfiectly after 10/60 minutes delay (?)……….

    • @aflatsnut
      @aflatsnut Před 2 lety +1

      Turn over but no start on my 07 was a switch at the base of the ignition key assembly. You need to buy the assembly minus the key tumbler (cheaper), remove the switch from new unit. Now you can remove the clamshell cover at the base of steering column where it goes into the dash and get to the bad switch without removing the entire assembly.

    • @opera93
      @opera93 Před 2 lety

      @@aflatsnut thanks….still issue infrequent is a :: “crank/ No start” , a random occurrence (??). I Have not checked all grounds,etc…though always starts after 10.0 minutes.. oddly irritating ….

  • @paulathacker6276
    @paulathacker6276 Před 2 lety

    None of mine will blow out

  • @Xtreme_Motorsports
    @Xtreme_Motorsports Před rokem

    those resistors are so trash, the 3 one always burns out on every single canyon/colorado, the resistor in general is just horribly designed

  • @parkerjorgensen8330
    @parkerjorgensen8330 Před 3 lety

    mine will do none, not 1-4

    • @WasherDryerMoney
      @WasherDryerMoney  Před 3 lety

      Mine was the same way.
      I would first try the resistor if that doesn’t work it probably is a wire harness melted somewhere. It’s hard to tell usually you have to unplug the harnesses to see if there’s a black burned up spot. Just go one of the time until you find it. It’s a pain.

  • @davidwoods5075
    @davidwoods5075 Před 11 měsíci

    05 Colorado. Problems all over the place. Kinda a piece of junk