Earthing for Net metering & for Lightning Arrestors / IEC NORM Commissioning 03453540734
Vložit
- čas přidán 3. 07. 2020
- Earthing for Net metering & for Lightning Arrestors / IEC NORM Commissioning 03453540734
IEC NORM Commissioning for Lightning Arrestors / Grounding / Earthing for 40 Kilowatts solar energy Project
Material list. - Věda a technologie
What a quality of work......
Thank you Sir,
Still.we're trying to improve ourselves
I dont mean to be so offtopic but does anybody know a method to log back into an instagram account?
I was stupid forgot my login password. I would love any tips you can give me.
@Quincy Augustus Instablaster =)
@William Ryder thanks so much for your reply. I got to the site thru google and im waiting for the hacking stuff now.
Takes a while so I will get back to you later with my results.
@William Ryder It did the trick and I actually got access to my account again. I am so happy:D
Thanks so much, you saved my ass :D
بہت اچھا کام کیا ھے آپ نے ۔۔۔اگر کاپر راڈ کے بعد کاپر وائر پر پی وی سی پائپ چڑھا لیا جائے تو کاپر وائر زیادہ محفوظ نہیں ھو جائے گی Oxidized ھونے سے؟؟؟؟
MsahAllah Bht Axha Kam Hai Apka.
Thanks Brother
Masha Allah
I am big fan of your videos brother
Thanks brother.. We're trying to improve ourselves
Good job
Thanks Samuel
Asalamualikum Bro, MashAllah Bro Keep It up.
Thanks Abdul Baseer sb
Supper earthing
Thanks brother
20 kilo watt lod के लिए कौन सा earthing कराना चाहिए
Bhai Jaan Battery Bus Bar py Total 10 + or 10 - Wire connect hain or ap khe rahy hai k total 12 banks hain.
Abdul Baseer sb.. Really thanks for watching,
And special thanks for raising a question.
Actually hum logo ne battery bank ki bus bar per busbar ki back se and front pe lugs connect kiye howe hein
thora sa bta dain bettery bus bar k bary main detail main
Zaroor mein kuch dinme detail video share karunga Insha Allah
Or bhai jaan pv connection k bary main b bta dain kitny panels hain or kitni strings banai hain
128 total solar panels hein
It is mandatory to install 3 separate earthings for AC, DC and Lightning Arrestor
Yes it is mandatory
Are you recommend for installation of earthing and lightning arrestor for 3.5 KW solar system?
No. Only 1 will be enough for that small system.
5 fit pe sand a rahe mai bor 20 fit tak le k gya lekin 90ohm resistance mil rahe
Apne copper rod k sath copper cable kese connect ki Howe hai?
03113360019
03453540734
Earthing par kharcha kitna ata hai
Sir it depends on hardware, the hardware chosen in above VDO would've cost around 130k each
Isko oxidization se kaise bachana hai??
NAHI BACHANA... as 1inch dia copper rod which is almost 10 ft in lenght will take tens of years to desolve in acid like lime and salt which we usually use while earthing procedure
@@HibaTradingSMCPVTLtd oxidization se iski effectiveness kum nhi ho jayegi? Jub copper k oper green layer ban jayegi
Oxidation is one form of metallic corrosion, which is a reaction that occurs during an ionic chemical reaction when oxygen is present on the metal’s surface. During this process, electrons move from the metal to the oxygen molecules. Thereafter there is a generation of negative oxygen ions in the metal, thus leading to the creation of a surface laden with oxide. In the case of copper, this oxidation occurs as a result of the exposure of copper to air, although salt water, acidic compounds and heat can also induce corrosion.
@@HibaTradingSMCPVTLtd yes, I am talking about the lightning arrestor part which is in the Air. After oxidation, is it as effective in attracting the lightning bolt as compared to no oxidation? I am trying to understand why lightning arrestors are not tin or nickel coated?
the only thing which we can do to stop oxidization is to use cathodic protection procure which is widely used in ships and bridges iskey ilawa pakistan mein SSGC apni pipe line ko oxidization se bachane k liye use karti hai
Bht acha kam kya he bhai ap ne ap ka number chhaye
03453540734
Jis jis bhai nay diesel generator ki training videos dekhni hai wo power learning channel per aa kar subscribe karlay free offer hain 😄 😀😀😀😀😀