100amp to 200amp service upgrade

Sdílet
Vložit
  • čas přidán 7. 09. 2024
  • we are upgrading out old fuse style 100amp service to a new 200amp breaker style service.

Komentáře • 25

  • @thomassladek9437
    @thomassladek9437 Před 7 měsíci +2

    "Extremely aggravating." You are too kind. Wrestling those SE cables is one of life's great challenges. Some electricians make a service loop for each cable inside the box and then connect the bare ends to the main breaker. This eases the aggravation a bit and also facilitates any future work that may be required. Another sensible practice is to connect all of the grounds and neutrals to their respective bars before installing any breakers. It's much easier that way because the breakers and the hot leads don't get in the way.

  • @robertcarpenter5923
    @robertcarpenter5923 Před 9 dny

    When you put the ground, you gotta put on a new job bar. Because that's your main panel. The neutral hubs the ground. How do it's work and then you? Separate your grounds after that, if you put a sub panel and you separate the grounds from the neutral. Or else you're reintroduced the neutral back into the ground system

  • @robertcarpenter5923
    @robertcarpenter5923 Před 9 dny

    You will not get a good ground if you separate the ground from the new codes. That's why when you tie everything at the first panel. You get a better ground because the neutral hubs the ground and then anything after that, you separate, maybe put a sub panel in. Next to that 1 or another, one or somewhere in the house.Then you separate the grounds and the neutrals

  • @danielwicks9703
    @danielwicks9703 Před rokem +1

    Nice upgrade money well spent

  • @TheAngryChimp
    @TheAngryChimp Před 4 měsíci +1

    Excellent! Just the informatiion I was needing.

    • @Grazing-M-Acres
      @Grazing-M-Acres  Před 4 měsíci

      Glad I could help!

    • @PennYankeeWoodworks
      @PennYankeeWoodworks Před 2 měsíci

      @@Grazing-M-Acresare you an electrician ?

    • @Grazing-M-Acres
      @Grazing-M-Acres  Před 2 měsíci

      @PennYankeeWoodworks I'm not a licensed electrician, I've always done my own electrical work though.

  • @robertcarpenter5923
    @robertcarpenter5923 Před 9 dny

    You know where we live at. You're not allowed to have any electrical panels in a wet room or bathroom. We'll make you Tear it out where we live

  • @petesilvestri
    @petesilvestri Před 4 měsíci

    Well done….

  • @EnjoytheToil
    @EnjoytheToil Před měsícem +1

    Is there a difference in the service line-in equipment? Did the utility company have to put in a 200amp compatible meter?

    • @Grazing-M-Acres
      @Grazing-M-Acres  Před měsícem +1

      @@EnjoytheToil I install a 200 amp meter combo base ( its code for my county). I also had the utility company upgrade the transformer and install a 200 amp service wire underground which they did for free.

    • @EnjoytheToil
      @EnjoytheToil Před měsícem

      @@Grazing-M-Acres right on. Thanks.

  • @user-yu7qx4mb2u
    @user-yu7qx4mb2u Před 5 měsíci +1

    If you dont mind me asking how much would it cost to change the 100 amp fuse box to a 200 amp service upgrade? Thank you

    • @Grazing-M-Acres
      @Grazing-M-Acres  Před 5 měsíci

      To be honest I have no clue. All electrical supply are expensive. If I had to guess probably a couple thousand or so.

    • @user-yu7qx4mb2u
      @user-yu7qx4mb2u Před 5 měsíci +1

      Thank you @@Grazing-M-Acres

    • @user-ld2pq8mm8x
      @user-ld2pq8mm8x Před 20 dny

      depend on what state, if that state applies the newest NEC code, start at 4K

  • @tested123
    @tested123 Před 2 dny

    what size entrance cable is that?

    • @Grazing-M-Acres
      @Grazing-M-Acres  Před 2 dny

      @tested123 I forget the exact name but it's aluminum wire rated for 200 amp.

    • @tested123
      @tested123 Před 2 dny

      @@Grazing-M-Acres in canada it would be 250 mcm.

  • @dalejones2108
    @dalejones2108 Před 6 dny

    6ft to main breaker NEC code

    • @Grazing-M-Acres
      @Grazing-M-Acres  Před 6 dny

      Main breaker is located outside just below the meter, pannel on the inside is a sub pannel.

    • @dalejones2108
      @dalejones2108 Před 6 dny

      No the height of the main breaker in your panel should be 6ft

    • @Grazing-M-Acres
      @Grazing-M-Acres  Před 6 dny

      @dalejones2108 is that a new code, I've never read that in our code book.