  • How to replace electronic board of vacuum cleaner Electrolux Pure D8.2 Silence PD82-4MB. Motor after few seconds stops on maximum power or on SMARTMode position when vacuuming. How to disassemble & assemble PureD8 vacuum cleaner after electronic board replacement. Vacuum cleaner didnt work on SMART / maximum power. Easy Disassembly & Assembly process.
    Part number: 140075397145
    proex.sk/produkt/elektronika-...
    Model With PNC:
    900258493 PD82-4MB
    900258505 PD82-4MB
    900401102 PD82-4MB
    900401116 PD82-4MB
    www.proexservis.sk/ponuka/ser...
    www.proex.sk/
    #diy #repair #vacuumcleaner #circuit #board #replacement #electrolux #assembly #disassembly
  • Jak na to + styl

Komentáře • 69

  • @user-rh3oz8in2z
    @user-rh3oz8in2z Před 8 měsíci +1

    Usterka usunięta. Ulubiony odkurzacz znów działa, tak jak powinien. Bardzo dziękuję za podzielenie się wiedzą!!! Bez tego napewno nie dałbym rady👍👍👍

    • @proexservis
      @proexservis  Před 8 měsíci

      Proszę bardzo 👍
      You are welcome 👍

  • @NONALFrance
    @NONALFrance Před rokem +2

    Thanks for this video. I just order one for 49,90€, shipping included. My motor stop after few seconds on every position. I will tell you after changing it in few days. See you soon.😉

    • @erikjansson664
      @erikjansson664 Před 6 měsíci

      Had same issue with mine. Board replacement solved the issue for me 😊

  • @erikjansson664
    @erikjansson664 Před 6 měsíci +1

    Thanks, really helpful video 🥳 my vac had same issue after 3,5 years. Motor sounded normal. Replaced board for ~22€ now it works fine. New board maybe has some improvements hopefully and last longer. 😊

    • @aleksandrscernogorcevs9753
      @aleksandrscernogorcevs9753 Před 6 měsíci +1

      where you buy PCB ???

    • @erikjansson664
      @erikjansson664 Před 6 měsíci

      @@aleksandrscernogorcevs9753
      Electrolux own site
      Shop.electrolux
      (Not sure which countries the site supports)

  • @guillaumefoch9861
    @guillaumefoch9861 Před 3 měsíci +1

    Thanks so much!!!!

  • @OskarLJ
    @OskarLJ Před 6 měsíci +1

    Great video, but I seem to have kind of the opposite problem. I have the PD82-Green and the speed settings works like normal, but the smart setting does not turn down suction if the inlet is blocked (cleaning carpets are therefore kind of a hassle). Do you have any suggestions on what the problem might be?

    • @proexservis
      @proexservis  Před 6 měsíci +1

      Thank you.
      Probably you have disconnected (hose) or faulty pressure sensor. It can be measured on this circuit board. Check if black hose from sensor is connected to sensor and to bag container. Full disassembly video is here: Complete Disassembly & Assembly of PURE D8.2 Silence PD82-4MB Electrolux Vacuum Cleaner
      czcams.com/video/7fULpW5cqqk/video.html

    • @OskarLJ
      @OskarLJ Před 6 měsíci

      @@proexservis I just had a look at the vacuum cleaner. Unfortunately it seems like all hoses are connected so it’s probably a faulty sensor. How do I measure the sensor and what values should I expect?

    • @proexservis
      @proexservis  Před 6 měsíci +1

      @@OskarLJ two contacts will connect when you blow the opposite sensor with mouth, maybe you have some dust in it so that pressure doesnt connect it. If sensors are ok after testing then PCB is bad

    • @OskarLJ
      @OskarLJ Před 6 měsíci

      @@proexservis the hoses were clean and properly connected. How do I test the function of the sensor?

    • @proexservis
      @proexservis  Před 6 měsíci

      @@OskarLJ with multimeter, measure connectivity on contacts during making air pressure to sensor

  • @adamski5498
    @adamski5498 Před rokem

    Hi. Can you tell me how the hoses are connected to the sensors? When undressing, I didn't pay attention to it and now the "smart" option does not work

    • @proexservis
      @proexservis  Před rokem

      Hi, did you replace pressure hose? New type is transparent with bigger diameter. On PCB pressure switch (1181971050) you should find which side is for filter and bag.

    • @adamski5498
      @adamski5498 Před rokem

      @@proexservis The vacuum cleaner motor was replaced. Each sensor has two inputs - upper and lower.
      When the pipe is clogged, the red light comes on, but the suction power does not decrease.

    • @proexservis
      @proexservis  Před rokem +1

      @@adamski5498 i think lower (bag) is going to front of vacuum cleaner. Not sure, I dont have this model here right now.

  • @trevipp
    @trevipp Před 10 měsíci

    So You have to order a new electronic board? You can’t fix the one you already have?

    • @proexservis
      @proexservis  Před 10 měsíci

      You can replace capacitators on it, but if you dont have tool for soldering then you have to replace that board

  • @Rollgott
    @Rollgott Před 9 měsíci

    Would a bad capacitor make the "S-Bag" light turn red and stop the motor, thinking the bag is full?

    • @proexservis
      @proexservis  Před 9 měsíci

      Yes, it could be capacitor/s, replacing of them should help or replace that circuit board

    • @Rollgott
      @Rollgott Před 9 měsíci

      @@proexservis What exactly is sensing if the bag is full. Some kind of airflow resistance sensor?
      Can I measure the capacitors for a standard value before spending time replacing them?

    • @proexservis
      @proexservis  Před 9 měsíci

      @@Rollgott it is connected with pressure sensors: 1181971050
      Probably you can disconnect it and it will not control it when you clog vacuum cleaner

    • @Rollgott
      @Rollgott Před 9 měsíci

      @@proexservis Ah perfect. This pressure sensor is a separate function of what you were talking about that might destroy the engine? Overvolting stuff.
      I see there is another PCB inside the vacuum. Which has those pressure sensors on it. It would be great to bypass them somehow!

    • @proexservis
      @proexservis  Před 9 měsíci

      @@Rollgott in many cases those sensors are not faulty, probably disconecting that connector on PCB (4 connector or 5 connector) should be enough to bypass them

  • @baranzo73
    @baranzo73 Před rokem +3

    First it was replaced under warranty, seems to fail always after 2 years. Bad design. Should be redesigned and replaced for free even after warranty. I will try to find which part fails on it.

    • @proexservis
      @proexservis  Před rokem

      There was change (probably already in warranty) that service should replace sensor hose (for different type) if it happens again, maybe you should check it
      140045222050, because old type hose can damage new pressure switch of circuit board

    • @baranzo73
      @baranzo73 Před rokem +2

      ​@@proexservis I managed to fix the board, no problems during 20 minutes testing. Checked all the power components and found with impedance analyzer that the foil capacitors were dying. 470 and 330 nF were only 310 and 205 nF, causing the power supply to drop/have ripple. Instead of the original X2 I replaced them with X1 types, which are bigger, but still fit on the board and tolerate pulses better. Not sure if this is the issue for everyone, the electrolytic caps and the pot can also easily fail. I recommend to disconnect the unit from the wall when not in use, because it is the transient pulses (lightning, industrial disturbances) that eat the lifetime of these caps.

    • @marekrehak5799
      @marekrehak5799 Před rokem +5

      Hey Zoltan and PROEX you are geniuses !!! This video helped me to open vacuum cleaner and comments inspired me to replace two foil yellow capacitors for price about half dollar. Thank you very much, problem is solved !!!

    • @baranzo73
      @baranzo73 Před rokem +1

      @@marekrehak5799 woohoo! I'm so happy that it helped you too!

  • @andresblanco435
    @andresblanco435 Před 11 měsíci

    So it's a bad model?

    • @proexservis
      @proexservis  Před 11 měsíci +1

      I dont think so, it can be easily repaired by replacing capacitators on its circuit board or replacing that PCB.
      Imho, for how many were sold, it doesn't happen often, but it happens… 🥲
      Overvoltage can cause this damage to the electronic board.

  • @mihaicurutiu6985
    @mihaicurutiu6985 Před rokem

    the electronic board price is half of the vacuum cleaner here. can it be fixed?😄

    • @proexservis
      @proexservis  Před rokem

      How much? 🫣 I dont know, because I never tried it, vacuum cleaner PureD8 cost over 200€+ and this board from 27€ to 35€ here in Europe, so is “cheap” to fix this problem. Do you have this model or different?

    • @proexservis
      @proexservis  Před rokem

      Once I tried to repair almost same board like this one but it didnt help, I replaced few components on it. Same result, vacuum stops on maximum power, so I dont waste more time and money to fix these boards if faulty board has no visible damage.

    • @mihaicurutiu6985
      @mihaicurutiu6985 Před rokem

      @@proexservis aprox 76 euros, same model. Next week I'll know for sure and keep you updated if you want.

    • @mihaicurutiu6985
      @mihaicurutiu6985 Před rokem

      @@proexservis thx for answering!

    • @proexservis
      @proexservis  Před rokem +1

      @@mihaicurutiu6985 where are you from? You can buy it from other country if your Electrolux dealer is selling it for this much.

  • @adzjozcosi1794
    @adzjozcosi1794 Před 4 měsíci

    Nie za bardzo ogarniam tą funkcje smart. Moc ma sie zmniejszac przy przytkaniu doplywu powietrza? Bez sensu to troche jak dla mnie jest. Wchodzi sie na dywan np to moc powinna sie zwiekszyc.

    • @proexservis
      @proexservis  Před 4 měsíci

      Google translate 🤔 :ponieważ ten mod zmniejsza wydajność tylko wtedy, gdy jest całkowicie zablokowany, aby nie uszkodzić silnika lub jeśli zasłona, dywan lub coś, co mogłoby zapaść się głębiej
      because this mod only reduces power suction if it is almost completely blocked so as not to damage the motor. Or if there is a curtain, carpet or something that could suck deeper into vacuum cleaner

    • @adzjozcosi1794
      @adzjozcosi1794 Před 4 měsíci +1

      @@proexservis to jest zrozumiałe i to wiem. Z drugiej strony jest electrolux i ich reklamy ze odkurzacz dostosowuje moc do danej powierzchni ... wg mnie to powinno być oparte na pomiarze prądu silnika i sterowaniu opartym na regulacji jego stałej wydajności, a chyba jest oparte tylko na tych dwóch 0-1 czujnikach cisnienia.

  • @Johan-lj6xm
    @Johan-lj6xm Před rokem +1

    Smart function dont work for me, It always is on max... Coclusion dont buy Electrolux.

    • @proexservis
      @proexservis  Před rokem

      Do you have model with plastic regulator? Probably you have broken regulator (plastic rod), it is easy to replace.

  • @Vacuum-cleaner-shorts
    @Vacuum-cleaner-shorts Před 9 měsíci

    It's not good when you block the suction at the vacuum cleaner 😠!!!!

    • @proexservis
      @proexservis  Před 9 měsíci

      How you want to test smart mode without blocking the suction? Any obstacle during vacuuming (carpet, textil, toys) can block it 🤔

    • @Vacuum-cleaner-shorts
      @Vacuum-cleaner-shorts Před 9 měsíci +1

      @proexservis I mean do not block the suction long. Max 4 sec more not. That will damage the vac motor

  • @Rollgott
    @Rollgott Před 9 měsíci

    Can i bypass this horrible stupid design of a sensor?

    • @proexservis
      @proexservis  Před 9 měsíci

      You can, but it will damage motor in short/long term period. That board is protecting it from over/undervoltage

    • @Rollgott
      @Rollgott Před 9 měsíci

      @@proexservis Oh, okay. Can you ELI5 a scenario where the motor would be damaged?

    • @proexservis
      @proexservis  Před 9 měsíci

      @@Rollgott overvoltage or undervoltage in electrical network, overheating etc. Any problem will take out motor completely or burn it (fire hazard). PCB is must have protection in modern vacuums.