  • It's important to note that the process of bleeding air from a hydraulic system can vary depending on the specific type of equipment or system you are working with. Always consult the manufacturer's guidelines or a professional with expertise in hydraulic systems if you are unsure about the proper procedure for your specific equipment.
    Visit our official website for hydraulic solutions: [PrimaryMover.com](www.primarymover.com)
    Connect with us on social media for updates and promotions:
    [Facebook]( / primarymover )
    [Twitter]( / pmhydraulics )
    [Instagram]( / primarymover )
    [Shop Our Collection](www.primarymover.com/collections)

Komentáře • 19

  • @This2isLife
    @This2isLife Před 2 měsíci

    Very useful info. Thanks!

  • @iman-klt
    @iman-klt Před 9 měsíci +3

    Great explanation ... looking forward to the pros and cons of the single vs double pump options. Thank you for your time to create these videos

    • @primarymover8249
      @primarymover8249  Před 9 měsíci +1

      Thanks for the support. We currently working on a video to address those differences. Please subscribe and thank you.

  • @MuddmonsterTV
    @MuddmonsterTV Před 9 měsíci +2

    Awesome video!!

  • @Pi-eight
    @Pi-eight Před měsícem

    I have a altec at248f 2016 my lift doenst work and the hidraulic tank had a lot bublees. Back there I overflow the tank, but I take it off. Só what I can do now?

  • @mach1231000
    @mach1231000 Před 7 měsíci +1

    Is it possible get a Pump with no attached tank, as I have seperate unit with hoses. Thx

  • @waqarrafique5194
    @waqarrafique5194 Před měsícem

    Hey, I have a question .. my dump box moves up and down with out giving any rpm when it’s rpm . But when it’s loaded I have to give 1500 rpm or more to lift the box up ….while lifting up I can hear some kind of air noise … could you please tell me if it is weak hydraulic pump or something else .

  • @user-pw5de5df1u
    @user-pw5de5df1u Před 3 měsíci

    Cuanto bale una tijera. Hidráulica

    • @primarymover8249
      @primarymover8249  Před 2 měsíci

      I am not sure what you are asking me sorry for the delay response.

  • @gregorymiller7861
    @gregorymiller7861 Před 5 měsíci

    What if the cylinder doesnt move up? Is there too much air in there n if so what's my nxt move. I think I ran the unit low oil in tank n she sucked in air....

    • @primarymover8249
      @primarymover8249  Před 2 měsíci

      If you tried the methods explained in this video then you might have a different issue. You could be having a issue with your relief valve. What type of setup do you have?

    • @gregorymiller7861
      @gregorymiller7861 Před 2 měsíci

      @@primarymover8249 I have a single. I believe it's the downward valve failure. The solenoid I can hear n feel clicking. If the valve is always in the open position it would make sense. But I bought the jungheinrich brand and dont know where to get parts

    • @jonesfamily2494
      @jonesfamily2494 Před 2 měsíci

      If it’s a two way cylinder set up on a one way system what would you block the 2nd line plug in a hydraulic line cylinder a bolt or a vent?

    • @primarymover8249
      @primarymover8249  Před 2 měsíci

      You would use a vent on the top port of the cylinder. the filling is called a breather fitting. Doing this you would only need one line from your single acting pump to the bottom of the cylinder.
      Thanks for your interest in our products.
      Here is a link to the breather fitting on our website
      www.primarymover.com/products/breather-6-sae

    • @primarymover8249
      @primarymover8249  Před 2 měsíci

      If you ran low on fluid and air was sucked into the system you will need to follow the proceedure of adding fluid and going thru bleeding steps.
      Video link -
      czcams.com/video/-7HhjMS_kp4/video.html&lc=UgzIqIJVBK_drxDCoGJ4AaABAg.A093tfnazg3A31YCnn6sme

  • @tonyspaulding
    @tonyspaulding Před měsícem

    Why does mine go up and not down the pump is runing up and down

    • @primarymover8249
      @primarymover8249  Před 15 dny

      One of your valves in your pump could be stuck. It is probably the directional valve. Debris can sometimes get in the valve and it get stuck in one position. Give us a call and we can discuss it with you.