PEX Universe
PEX Universe
  • 300
  • 8 922 069

Video

Quick & Easy: Install Revital/Line Baseboard Covers in 15 Mins!
zhlédnutí 763Před 11 měsíci
Quick & Easy: Install Revital/Line Baseboard Covers in 15 Mins!
Revital/Line Universal Replacement Baseboard Covers By Slant/Fin
zhlédnutí 1,6KPřed 11 měsíci
Revital/Line Universal Replacement Baseboard Covers By Slant/Fin
How Adey's MagnaClean Magnetic Boiler Filters can save you money on your ENERGY BILL!
zhlédnutí 488Před rokem
How Adey's MagnaClean Magnetic Boiler Filters can save you money on your ENERGY BILL!
Unboxing Adey's Magnaclean Magnetic Boiler Filter
zhlédnutí 346Před rokem
Unboxing Adey's Magnaclean Magnetic Boiler Filter
Different Types Of Tyco Fire Sprinkler Heads
zhlédnutí 1,1KPřed rokem
Different Types Of Tyco Fire Sprinkler Heads
How To Protect Your Hot Water Pipes This Winter!!!
zhlédnutí 426Před rokem
How To Protect Your Hot Water Pipes This Winter!!!
Channellock SpeedGrip Pliers Comparison
zhlédnutí 421Před rokem
Channellock SpeedGrip Pliers Comparison
Stiebel Eltron Electric Tankless Water Heater
zhlédnutí 4,6KPřed 2 lety
Stiebel Eltron Electric Tankless Water Heater
Expander super tool
zhlédnutí 670Před 2 lety
Expander super tool
Different Types Of PVC Fittings
zhlédnutí 1,9KPřed 2 lety
Different Types Of PVC Fittings
The Triple hydronic baseboard heater
zhlédnutí 1,6KPřed 2 lety
The Triple hydronic baseboard heater
PEXGun PG-101X
zhlédnutí 1,8KPřed 2 lety
PEXGun PG-101X
How to Fix a Leaky Copper Pipe (No Soldering!)
zhlédnutí 24KPřed 2 lety
How to Fix a Leaky Copper Pipe (No Soldering!)
What Is The Joist Track?
zhlédnutí 4,1KPřed 3 lety
What Is The Joist Track?
Understanding THIS Insulation Is No Joke!
zhlédnutí 1,3KPřed 3 lety
Understanding THIS Insulation Is No Joke!
What Is That Grease Trap Really Doing??!!
zhlédnutí 4,4KPřed 3 lety
What Is That Grease Trap Really Doing??!!
IS IT TIME TO REPLACE THAT THERMOSTAT?!!
zhlédnutí 1KPřed 3 lety
IS IT TIME TO REPLACE THAT THERMOSTAT?!!
How Many Zones Can This Switching Relay Handle???
zhlédnutí 2,4KPřed 3 lety
How Many Zones Can This Switching Relay Handle???
Enhance Any Zone Valve System With This!
zhlédnutí 2,2KPřed 3 lety
Enhance Any Zone Valve System With This!
The Spirocombi Air & Dirt Separator Will Save Your Heating System
zhlédnutí 7KPřed 3 lety
The Spirocombi Air & Dirt Separator Will Save Your Heating System
What is axiom demineralizer?
zhlédnutí 1,1KPřed 3 lety
What is axiom demineralizer?
One-Stop Guide To Point Of Use (POU) Water Heaters
zhlédnutí 15KPřed 3 lety
One-Stop Guide To Point Of Use (POU) Water Heaters
What Is A Firestop And How Does It Protect Your Home?
zhlédnutí 1,3KPřed 3 lety
What Is A Firestop And How Does It Protect Your Home?
What Is A Pipe Nipple?
zhlédnutí 44KPřed 3 lety
What Is A Pipe Nipple?
What temperature should I set my water heater? (Safe water temperature ranges)
zhlédnutí 36KPřed 3 lety
What temperature should I set my water heater? (Safe water temperature ranges)
Best Hand Tools Made In USA?
zhlédnutí 2,9KPřed 3 lety
Best Hand Tools Made In USA?
Tankless Water Heaters: Which One Is Right For You?
zhlédnutí 94KPřed 3 lety
Tankless Water Heaters: Which One Is Right For You?
How To Install A Channel Trench Drain?
zhlédnutí 2,5KPřed 3 lety
How To Install A Channel Trench Drain?
Gas Regulators
zhlédnutí 273KPřed 3 lety
Gas Regulators

Komentáře

  • @janicejackson6766
    @janicejackson6766 Před 2 dny

    Thanks, for the content. Can I use pressfit on a standard copper pipe. Essentially, I want to replace plumbing under the sink.

  • @albyus
    @albyus Před 5 dny

    hi!!, I would like to mount the Spirocombi, I would mount it on a VERTICAL multilayer pipe with flow from bottom to top. The spirocombi has the flow arrow from top to bottom. Just loosen the ring and rotate the 2 connectors or it's not possible, thanks

  • @Carnivorous-Vegan
    @Carnivorous-Vegan Před 10 dny

    What happens if the small tubing to the switch gets disconnected?? Would the pump run continuously till it burns out?

  • @lorrainericketts8603
    @lorrainericketts8603 Před 11 dny

    Can you use any type toilets

  • @busterhyman6633
    @busterhyman6633 Před 12 dny

    I have the Maxtitol 35-L want to go from 1 1/4 high pressure to 7WC for a portable genset. My regulator as the vent limiter. Do I need the Maxitrol 3/8" NPT Connection Vent Protector for 325-5 and 325-5L.

  • @dominiccabanes3979
    @dominiccabanes3979 Před 12 dny

    why there is red light S Indicator on my scala water booster

  • @anthonyhitchings1051
    @anthonyhitchings1051 Před 14 dny

    Our Rheem H.E. tankless gas fired W.H. condensate remains stubbornly alkaline.

  • @gregvoigt551
    @gregvoigt551 Před 17 dny

    its 220 acv,there is no positive wire and negative wire

  • @FelixAcquah-ub2eg
    @FelixAcquah-ub2eg Před 17 dny

    Could you please let me know what type of pressure switch I can install on a 2" (DN50) water line so that it automatically starts and stops the pump at 3 bar and 6 bar, respectively?

  • @dustbat
    @dustbat Před 19 dny

    I am looking to run a simple drain for my water softener. It will be under shallow gravel. Will get some foot travel. Which pipe should I use?🦇

  • @kinokind293
    @kinokind293 Před 20 dny

    As with the other video from this source, it is about half wrong. First, forced air shouldn't be lumped in with baseboards or radiators, as they are almost unrelated. First, cast iron radiators heat mostly by convection, heating the air around them which circulates (convectively) through the room. Depending on specifics, about 80% of the heat from a cast iron radiator is convective, the remainder is radiated infrared: the heat that you feel if you hold your open hand facing the radiator (or a fire). Fin-tube convectors, of the type he shows, do almost all of their heating by convection. There is some slight radiation, but the hot tubing is isolated from the outside by air gaps. There are also cast iron baseboards, which he does not mention, which are midway between. The biggest difference is that a cast iron radiator contains quite a mass of cast iron, which, once heated, retains its heat even when the steam or hot water is off. This results in slower diffusion of heat throughout the room and longer intervals between operation of the boiler. Thus, the temperature remain more even. Fin-tube baseboard convectors, on the other hand, have virtually no thermal inertia and will go cold almost as soon as the boiler shuts off. For this reason you should never use fin-tube and cast iron in the same installation, since the fin-tube cools instantly while the cast iron remains hot. This means the room with fin-tube will be cold while the room with cast iron remains warm. Where do you put the thermostat? If you put it in the fin-tube room, the boiler will run more often than if you put it in the cast iron room, but then the fin-tube room will be fine but the cast iron room too warm. If you put it by the cast iron, then the fin-tube room will be cold. Don't do it. Forced air is neither convective nor radiative, which is why it shouldn't even be included in this discussion. A wood stove is more similar to radiators and baseboards than forced air is.

  • @kinokind293
    @kinokind293 Před 20 dny

    Wow, is this a terrible video! There are so many errors that it's evident the presenter doesn't really understand how some of this works. He's in a nice shirt, and the warehouse is clean, but that's about it. In a hot water system you can make the pipe connections at any pair of taps, but the air vent has to be at the very top, since air will start accumulating from the top down, and if you don't vent it from the top then most of the radiator will be full of air, not hot water. With one-pipe steam, although there are two 1/8" taps for venting, only the top can be used for hot water and only the lower one for steam. Why, because if you put the steam vent at the top steam, which is lighter than air, will rise to the top of the radiator, travel to the far side, and shut the air vent leaving the radiator partially filled with air, not steam. Also, he is incorrect saying you need a bushing at the bottom in all cases. Untrue. one-pipe steam often has a 1-1/4" valve connection. Only the smallest radiators will have 1".One-pipe steam never, ever, uses anything smaller than 1". And the brass return elbow would never be used with one-pipe and almost never with two-pipe. Only hot water. And he never even mentions 2-pipe steam, which comprises probably a third of all steam. I am impressed that most of what he says is either partially or totally wrong. Do your research elsewhere!

  • @shanebrown5709
    @shanebrown5709 Před 23 dny

    Put your finger thru the hole in the teflon easier to apply and get it tight when we do boilers we use both. use to use just dope tell one time it leaked and an 1-1/2" B.I.header with 4 zones its a pain in the ass to strip it back and that one time I had to remove the whole header in plumbing u learn from your one time mistakes.

  • @ElPescadorTejano
    @ElPescadorTejano Před 24 dny

    I stopped installing those years ago

  • @ForgeAheadwithMike
    @ForgeAheadwithMike Před 26 dny

    For my RV’s main propane line, I have black iron pipe, with an adapter for a flare hose connection to my RV appliance. Wouldn’t I just use the yellow gas tape?

  • @danielames7611
    @danielames7611 Před 26 dny

    Simple and informative. Thank you for respecting my time.

  • @comeinhandynow
    @comeinhandynow Před měsícem

    This might be a useful video for when the water level is too high or pump doesn’t run: czcams.com/video/SL-MScl53IU/video.htmlsi=DimuPh-0154_e-Qi

  • @kathyern861
    @kathyern861 Před měsícem

    Yeah, 1/2 inch - uh-huh reaaaaaaaaaaal easy. Now, try 3/4 inch pipe, not so eassssssssy

  • @jeffvioli5559
    @jeffvioli5559 Před měsícem

    Looking at the Scala2? … Stop. Take a breath. I have purchased and owned a Scala2. Let me inform you, before you make your decision. Like me you probably want to increase your water pressure. You are looking for a pump that is good for residential applications. Something that isn’t noisy. Well, that’s why I bought the Scala2. Let me tell you. It was nice, while it lasted. Purchased in January of 2024 it performed for almost three and half months. That’s months, not years, and definitely not decades. Just recently it sprung a leak and it was a gusher! My first response was that an o-ring needed replacing. I had a plumber come in. He was sorry to say the problem was much more serious and that he had seen many Scala2 with the same problem. I live just outside Toronto, in Ontario, Canada. My assumption after three months of ownership was that Grundfos Canada would give me a new pump or perhaps refund my money. Care to guess what really happened? The Grundfos service rep from Oakville told me, “If the engineers want to find an excuse to void the warranty, they will.” The sad part of this story is that this is my second, (yes second!) Grundfos pump. I used the MQ series pump for almost ten years. The scala2 was supposed to be the upgrade. Think you’ll be rewarded for customer loyalty with Grundfos? Think again! So if you’ve made it this far, it’s time to reveal my advantage. The Jeff advantage. I’m one of the lucky people who can laugh-off $2000. $2000 will not ruin my month. Heck it will barely ruin my week, but for you, yes you… the hard working guy or girl who saves pennies and requires value, and who absolutely cannot afford to lose $2000, then your big brother Jeff is here for you. I’ve taken the hit! And it wasn’t just any hit, it was a Grundfos sucker-punch. Grundfos actually took a swing at a loyal customer, but here I am, still standing! So allow me to say to all Grundfos customers, past and present, I took the sucker punch for you, and I was happy to do it. Now you know that the Scala2 is weak engineering, and that Grundfos Canada will find any excuse to keep your money after it breaks. Remember that once broken, they cannot be repaired. So… to the little guy, think of me as your big brother who’s looking out for you. I don’t use an avatar. Jeff Violi is my real name. I will do my best to reply honestly to any replies, except from Grundfos. Grundfos doesn't deserve anything more from me.

  • @brandonyoder6646
    @brandonyoder6646 Před měsícem

    Very helpful I’m moving one of mine to another room and set it back up this answered everything I had questions about my biggest issue will be unhooking it to set it back up in another room.

  • @CyberSlayerNo1
    @CyberSlayerNo1 Před měsícem

    You didn't explain how sewage pumps work, you explained why they're required.

  • @drbhargavtrivedi8779
    @drbhargavtrivedi8779 Před měsícem

    Hi .. if I have a exclusive return line for cold water , which circulate pump should be used ?

  • @Nolaman70
    @Nolaman70 Před měsícem

    Pex B is more restrictive at the fittings.

  • @rawyin
    @rawyin Před měsícem

    You're just shucking product.

  • @carlvajda6131
    @carlvajda6131 Před měsícem

    Failed to specify whether tightening adjustment raised or lowered pressure setting. Also did not explain details on adjustments of second spring. Need a redo on this video!

  • @obijiakyanthony1294
    @obijiakyanthony1294 Před měsícem

    Do you have a PDF of these lecture please

  • @mackg02
    @mackg02 Před měsícem

    Is the 653 B NLC ¾" for potable water

  • @davenoi9609
    @davenoi9609 Před měsícem

    PEX is a polyethylene material which has undergone a change in molecular structure using a chemical or a physical process whereby the polymer chains are chemically linked. Crosslinking of the polymer chains of polyethylene (HDPE) into PEX for pipes results in improved properties such as elevated temperature strength and performance, flexibility, chemical resistance, environmental stress crack resistance (ESCR), resistance to slow crack growth (SCG), toughness, and abrasion. Crosslinking makes PEX a "semi-thermoset" polymer, providing excellent long-term stability.

  • @christopher9727
    @christopher9727 Před měsícem

    Jesus Christ is the only hope in this world no other gods will lead you to heaven There is no security or hope with out Jesus Christ in this world come and repent of all sins today Today is the day of salvation come to the loving savior Today repent and do not go to hell Come to Jesus Christ today Jesus Christ is only way to heaven Repent and follow him today seek his heart Jesus Christ can fill the emptiness he can fill the void Heaven and hell is real cone to the loving savior today Today is the day of salvation tomorrow might be to late come to the loving savior today Holy Spirit Can give you peace guidance and purpose and the Lord will John 3:16-21 16 For God so loved the world, that he gave his only begotten Son, that whosoever believeth in him should not perish, but have everlasting life. 17 For God sent not his Son into the world to condemn the world; but that the world through him might be saved. 18 He that believeth on him is not condemned: but he that believeth not is condemned already, because he hath not believed in the name of the only begotten Son of God. 19 And this is the condemnation, that light is come into the world, and men loved darkness rather than light, because their deeds were evil. 20 For every one that doeth evil hateth the light, neither cometh to the light, lest his deeds should be reproved. 21 But he that doeth truth cometh to the light, that his deeds may be made manifest, that they are wrought in God. Mark 1.15 15 And saying, The time is fulfilled, and the kingdom of God is at hand: repent ye, and believe the gospel. 2 Peter 3:9 The Lord is not slack concerning his promise, as some men count slackness; but is longsuffering to us-ward, not willing that any should perish, but that all should come to repentance. Hebrews 11:6 6 But without faith it is impossible to please him: for he that cometh to God must believe that he is, and that he is a rewarder of them that diligently seek him. Jesus

  • @christopher9727
    @christopher9727 Před měsícem

    Jesus Christ is the only hope in this world no other gods will lead you to heaven There is no security or hope with out Jesus Christ in this world come and repent of all sins today Today is the day of salvation come to the loving savior Today repent and do not go to hell Come to Jesus Christ today Jesus Christ is only way to heaven Repent and follow him today seek his heart Jesus Christ can fill the emptiness he can fill the void Heaven and hell is real cone to the loving savior today Today is the day of salvation tomorrow might be to late come to the loving savior today Holy Spirit Can give you peace guidance and purpose and the Lord will John 3:16-21 16 For God so loved the world, that he gave his only begotten Son, that whosoever believeth in him should not perish, but have everlasting life. 17 For God sent not his Son into the world to condemn the world; but that the world through him might be saved. 18 He that believeth on him is not condemned: but he that believeth not is condemned already, because he hath not believed in the name of the only begotten Son of God. 19 And this is the condemnation, that light is come into the world, and men loved darkness rather than light, because their deeds were evil. 20 For every one that doeth evil hateth the light, neither cometh to the light, lest his deeds should be reproved. 21 But he that doeth truth cometh to the light, that his deeds may be made manifest, that they are wrought in God. Mark 1.15 15 And saying, The time is fulfilled, and the kingdom of God is at hand: repent ye, and believe the gospel. 2 Peter 3:9 The Lord is not slack concerning his promise, as some men count slackness; but is longsuffering to us-ward, not willing that any should perish, but that all should come to repentance. Hebrews 11:6 6 But without faith it is impossible to please him: for he that cometh to God must believe that he is, and that he is a rewarder of them that diligently seek him. Jesus

  • @KHarv-vx4ky
    @KHarv-vx4ky Před měsícem

    no thnks hippy

  • @dillonphillips313
    @dillonphillips313 Před měsícem

    Up honor 😂

  • @zacharyolds1639
    @zacharyolds1639 Před měsícem

    Metric ton of shite is needed for fusion lol 😂

  • @donmar6156
    @donmar6156 Před měsícem

    Bro you installed the slip on back to front

  • @pezjme
    @pezjme Před měsícem

    Can you run anti-freeze in those? If not, what can you use that doesn't freeze?

  • @high_fructose_corn_syrup
    @high_fructose_corn_syrup Před měsícem

    What exact model would i need for a toilet, shower stall and utility sink? Pls n ty

  • @vickynoname9860
    @vickynoname9860 Před měsícem

    What professionals remove, power coat and reinstall radiators? I am about to spend 30k for an HVAC if I dont find someone to paint these ugly radiators.

  • @thomashall9792
    @thomashall9792 Před 2 měsíci

    All I want to know is where is the serial number for my HA036240.

  • @thehuntingscotsman6169
    @thehuntingscotsman6169 Před 2 měsíci

    Straight to the point and perfectly succinct... Brilliant! Thank you! 😎

  • @sanjithechef
    @sanjithechef Před 2 měsíci

    This sucks

  • @mwilliamson3989
    @mwilliamson3989 Před 2 měsíci

    Thanks so much for this information I really appreciate it.

  • @mwilliamson3989
    @mwilliamson3989 Před 2 měsíci

    Thank you

  • @willistisdale4293
    @willistisdale4293 Před 2 měsíci

    Good video

  • @davidbentley7102
    @davidbentley7102 Před 2 měsíci

    the leak light intermittently illuminates, no leak in the house or around the pump is present. The reset eliminates the warning light, but then it returns. How is this rectified?

  • @darekk1108
    @darekk1108 Před 2 měsíci

    not suppose to use tape on pvc !

  • @bigglilwayne7050
    @bigglilwayne7050 Před 2 měsíci

    Everyone uses the two 45°s and one 90°..... I prefer three 60° elbows....

  • @bodinian
    @bodinian Před 2 měsíci

    Please lower the background music volume

  • @artemiorodriguez2676
    @artemiorodriguez2676 Před 2 měsíci

    Demasiado grande la. Crimpiadora Mese sito con una sola manon

  • @mikepihaylic77
    @mikepihaylic77 Před 2 měsíci

    Only made a few crimps and then the gear that goes with the ratchet just became worn out to thepoint where it was unusable,nit good luck find in finding any replacement parts

  • @DarrenRomano
    @DarrenRomano Před 2 měsíci

    Is it ok to use a 3/4’ baseboard with reduced down to 1/2’ pex piping?throughout the house?