Schiedel UK
Schiedel UK
  • 81
  • 507 714
Why you need an account on the Schiedel Shop! 🛒
We want to advise all of our customers that the Schiedel store is fully accessible to shop at a time convenient for you, allowing you to place orders twenty-four hours a day! 👏
This brief explainer video shows how the shop can make your life easier and why more and more of our customers are choosing to order online! 💡
Set up your account today, and we will let you know once it is activated 🧡
shop.schiedel.com/uk/my-account/
Marketing.uk@schiedel.com
#Makinglifesimple #Anameyoucantrust #Schiedelservices #customerservices #customerexperience #ecommerce #digitalisation #marketing #brand #movingforwards
zhlédnutí: 47

Video

When you should choose Ceramic or Pumice chimney systems?
zhlédnutí 141Před 11 měsíci
Our new explainer videos aim to highlight the key differences, features and benefits of our pumice and ceramic chimney systems. It also looks at which systems are best suited to which projects. This video is ideal for architects, developers, builders, merchants and contractors who are not 100% sure on which chimney system would be better for their projects. If you have any questions or need sup...
The Hale Outdoor Kitchen 2023 🔥☀️
zhlédnutí 277Před 11 měsíci
How ''The Hale'' is different to your standard outdoor kitchens! 🔥💡 1) This unit is made from 100% natural pumice. 💯 2) Pumice is the best insulating material in the UK market. 3) You cannot get this level of insulation with brick, breezeblock or any other material. 🤗 4) These units can be placed in front of fences, walls, bushes etc and won't be a fire risk. 5) They are so well insulated they ...
Introducing the Schiedel Shop!
zhlédnutí 25KPřed rokem
📣📣 We are excited to announce that our brand-new Schiedel Shop is now live to existing trade customers! 📣📣 This new system will allow you to order online, see all previous orders, download price lists, brochures, tech sheets and more! 🖥️ A perfect solution when you are exceptionally busy, allowing you to order 24 hours a day! We thank our customers for their assistance and patience as we develo...
Save money on gas usage, by installing a safe wood burning stove, with firestop plates
zhlédnutí 724Před rokem
ICID Plus has been tested and approved to meet the latest BS EN1856-1 requirements when passing through either combustible or non combustible floors with a distance to combustible material of 50mm within both the floor cavity and within a shaft. The firestop plates have also been tested and approved to BS476 Part 20. All the tests have been carried out using the latest design of ventilated fire...
ePURO official presentation with David Wright, July 2022
zhlédnutí 148Před 2 lety
The Schiedel ePURO fine dust filter is an electrostatic particle separator for wood burning appliances, such as wood burning stoves, but also for wood/pellet central heating systems, up to 50 kW. Following events held in July 2022, thanks to our Product Manager David Wright, we have released the official presentation for the ePURO.
The fine dust PM2.5 filter for wood burning stoves
zhlédnutí 827Před 2 lety
ePURO is an electrostatic fine dust separator for effectively reducing flue gas particles in wood burning appliances in existing buildings, drastically reducing PM 2.5 particles by up to 95% As a renewable resource, wood releases only as much carbon dioxide (CO2) when burning, the same as with the natural decomposition process in the forest, or as much as the tree has stored during its growth p...
The features of our brand new Combined Screwfit Pot Hanger and Terminal!
zhlédnutí 172Před 2 lety
We are delighted to present one of our residential experts, Ken McKenzie, as he explains the exact benefits of our brand new Combined Screwfit Pot Hanger Terminal! Get the full technical specs or contact us for support via the website! ow.ly/RvnG50INxsv
Schiedel UK Corporate Movie 2022
zhlédnutí 368Před 2 lety
Our brand new corporate movie looks at Schiedel UK and specifically our Washington branch. Incorporating our manufacturing processes, our staff and what we stand for as a brand! A proud North-East based business for over 75 years!
Fitting a stove and re-lining a chimney flue using steel flexible liner
zhlédnutí 10KPřed 2 lety
This video shows the installation of a stove, after re-lining an existing chimney using Schiedel's TecnoFlex Flexible Liner. The combined screwfit pot hanger / terminal is shown, making it easier for installers to complete the entire installation. www.schiedel.com/uk/products/steel-system-chimneys/tecnoflex/ TecnoFlex Plus is a twin skin flexible chimney liner designed for gas, oil and multi-fu...
Schiedel - who we are
zhlédnutí 408Před 2 lety
Our vision: We are the leading provider in the market for chimney and flue systems, integrated stove and ventilation solutions. Our mission: We develop technically advanced, design-oriented products to improve the living environment. Our beliefs: the stove is the heart of the house. Our promise: With expertise and passion we create future-proof chimneys, stoves and ventilation solutions to brin...
Schiedel ceramic chimney systems - a guide
zhlédnutí 322Před 2 lety
A brief guide on how to build a chimney using clay based ceramic components, which are one of the safest and durable methods to add a chimney. Ceramic is also a superb product at a good price. www.schiedel.com/uk/products/ceramic-system-chimneys/sih-liners/ Features - Suitable for all fuels - gas, oil, solid fuels and biomass fuels. - Wide range of accessories to suit numerous installations. - ...
Chimney flue installation, with a noise reducing silencer in a commercial factory building.
zhlédnutí 2,1KPřed 2 lety
ICS 5000 is a multi-functional twin wall insulated venting system, which is suitable for internal and external use on a wide range of engineering, combustion and process equipment, including heating appliances, diesel generators, CHP systems and service ducting. This 3D animation shows the vertical installation with the use of two silencers: a resonance one and an absorption one. ICS 5000 comes...
Horizontal flue installation, with a noise reducing silencer in a commercial factory building.
zhlédnutí 2,1KPřed 2 lety
ICS 5000 is a multi-functional twin wall insulated venting system, which is suitable for internal and external use on a wide range of engineering, combustion and process equipment, including heating appliances, diesel generators, CHP systems and service ducting. This 3D animation shows the horizontal installation with the use of two silencers: a resonance one and an absorption one. ICS 5000 com...
Cascade boiler installation with the Schiedel Metaloterm® MF system
zhlédnutí 486Před 2 lety
The Metaloterm® MF system is a modular twin wall insulated flue/chimney system, made of stainless steel, with a sealing ring. Metaloterm® MF is a universal flue/chimney system that is suitable for both high and low temperatures, non-condensing and condensing applications with flue gasses in positive and negative pressure. It can resist a chimney fire. Therefore the system is suited for a wide r...
Schiedel ceramic chimney systems - a guide
zhlédnutí 352Před 2 lety
Schiedel ceramic chimney systems - a guide
SCHIEDEL - A NAME YOU CAN TRUST.
zhlédnutí 78Před 3 lety
SCHIEDEL - A NAME YOU CAN TRUST.
CPD - Stoves and chimneys in self-build projects - a guide
zhlédnutí 977Před 3 lety
CPD - Stoves and chimneys in self-build projects - a guide
Building a volcanic pumice fire-chest for an open fireplace.
zhlédnutí 1,2KPřed 3 lety
Building a volcanic pumice fire-chest for an open fireplace.
ICID Plus Double Wall Adjustable Starter Section installation guide
zhlédnutí 1,8KPřed 3 lety
ICID Plus Double Wall Adjustable Starter Section installation guide
Advanced manufacturing robot facilities
zhlédnutí 642Před 3 lety
Advanced manufacturing robot facilities
Flexible liner production
zhlédnutí 349Před 3 lety
Flexible liner production
Paint plant - painted components to the customer specification
zhlédnutí 83Před 3 lety
Paint plant - painted components to the customer specification
Dynamic steel tube production with multiple diameters
zhlédnutí 319Před 3 lety
Dynamic steel tube production with multiple diameters
Sirius - The complete DEFRA exempt wood burning stove and chimney package for house installations
zhlédnutí 16KPřed 3 lety
Sirius - The complete DEFRA exempt wood burning stove and chimney package for house installations
Stove and chimney flue installation in a log cabin / outhouse /wood built home / building
zhlédnutí 11KPřed 3 lety
Stove and chimney flue installation in a log cabin / outhouse /wood built home / building
AR Augmented Reality Chimney Builder for Stoves
zhlédnutí 329Před 3 lety
AR Augmented Reality Chimney Builder for Stoves
Volcanic Pumice Chimney System and Stove Combined - Defra Exempt and clearSkies Level 5
zhlédnutí 37KPřed 3 lety
Volcanic Pumice Chimney System and Stove Combined - Defra Exempt and clearSkies Level 5
Fitting a stove and re-lining a chimney flue using steel flexible liner
zhlédnutí 19KPřed 4 lety
Fitting a stove and re-lining a chimney flue using steel flexible liner
Commercial installation using the HP5000 chimney exhaust system
zhlédnutí 666Před 4 lety
Commercial installation using the HP5000 chimney exhaust system

Komentáře

  • @MrTrapper28
    @MrTrapper28 Před 5 měsíci

    Having this installed in my house in two weeks. Expensive but looks great.

  • @MrTrapper28
    @MrTrapper28 Před 5 měsíci

    Having this exact system installled in about two weeks time along with a Hwam stove. Looking forward to enjoying cosy nights!

  • @BmcN72
    @BmcN72 Před 6 měsíci

    No vermiculite?

  • @jahidhassan64
    @jahidhassan64 Před 11 měsíci

    Hello sir, I saw your youtube. Your content is unique. I enjoy your video. But why you do not SEO your channel? If you do SEO your channel must grow and your viewers and subscribers will be increase. And I saw you do not use any tag on your channel and videos. Tags help you to reach targeted audience. I can SEO on your 2 Videos free if you want.

  • @Swerve744
    @Swerve744 Před rokem

    Is this liner smooth on the inside

  • @RichardSmith-wr6go
    @RichardSmith-wr6go Před rokem

    How does 316L inner skin twinwall compare to 904? Will 316L stand up to smokeless coal use as long as the stove isn't slumbered or coal/wood mixed fires. Some people are stating you must use 904 if burning smokeless.

  • @portfolios7877
    @portfolios7877 Před rokem

    How program ?

  • @austinjohnson4890
    @austinjohnson4890 Před rokem

    Amazing animation.

  • @huchotaimen
    @huchotaimen Před rokem

    Very good 👌

  • @cliffords1325
    @cliffords1325 Před 2 lety

    p̷r̷o̷m̷o̷s̷m̷

  • @davyhh396
    @davyhh396 Před 2 lety

    Hi is there any more videos of the rendering being done thanks

    • @garydarragh4123
      @garydarragh4123 Před 2 měsíci

      Did you ever find anymore videos of the rendering being done?

  • @occidentadvocate.9759

    Thats exactly what id need for my house, as iv been thinking getting a Woodburner? Does your company do the fires too?

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 2 lety

      Hello sorry for the delayed response to this, we do have two models available, do you want to pop your email address over and I can send you some information? It's Leoni.thompson@schiedel.com. Thanks Leoni

  • @rossbj138
    @rossbj138 Před 2 lety

    What would happen if the flexi pipe was installed upside down? Thanks

  • @user-re6js1ke6e
    @user-re6js1ke6e Před 2 lety

    In what direction label arrow should point?

  • @peterivins973
    @peterivins973 Před 2 lety

    Hello do all chimneys have an offset bend in them and not just straight up. Thanks

  • @markrainford1219
    @markrainford1219 Před 2 lety

    Surely the ventilated collar between floors breeches Part E of the UK building regulations?

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před rokem

      Hi. Sorry for the late reply as we didn't see the notification for this. Ventilation is critical in this aspect to stop any overheating near combustible areas. Also, for first floors, designers tend to create a column wall around the pipe for safety reasons, so any noise from below isn't heard

  • @fablan3308
    @fablan3308 Před 2 lety

    Why do you need a flue if you have a chimney Can't you have a bit of round Steel tube A meter half going into the chimney and then put a plate on the Like you have

  • @michealbreathnach2928

    No vermiculite insulation around the new liner?? I thought that it's essential to insulate. I have removed several burnt out liners because of lack of insulation and burn out

    • @jimskirtt5717
      @jimskirtt5717 Před rokem

      Michael, where do I put the vermiculite - on top of the closure plate? If so, to what depth? Or do I just pour a LOT of it down the outside of the liner from the chimney top? Thanks.

    • @michealbreathnach2928
      @michealbreathnach2928 Před rokem

      @@jimskirtt5717 How are you Jim? First you need to ensure that the base is well sealed with a neatly cut steel plate so the vermiculite doesn't pour onto the floor, then head up top to the chimney top and I normally cut a hole out of the base of a large bucket of plastic tub. The hole will be slightly bigger than your new steel flue liner but not larger than the old flue. Then tape the top of the new liner and pour the vermiculite into the tub. That will guide the vermiculite into the gap between your new steel liner and the old flue. It could take a few bags in large chimneys

    • @jimskirtt5717
      @jimskirtt5717 Před rokem

      @@michealbreathnach2928 Many thanks for that, Michael. Much appreciated.

  • @konradtondera271
    @konradtondera271 Před 2 lety

    what diameter of the pipe above the fireplace

  • @riveroflifeministry8299

    My understanding is that one of the purposes of the firestop plates at the floors is to take the weight of the flue above, so that it is not all resting on the stove. But how does it take the weight, since it is smooth? Is it through friction?

  • @robertcornelisse8664
    @robertcornelisse8664 Před 3 lety

    Is this available in the USA?

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 3 lety

      Hi Robert, apologies for the delay. Unfortunately this is not currently available in the USA, I believe this is something to do with a difference in the regulations.

    • @robertcornelisse8664
      @robertcornelisse8664 Před 3 lety

      @@SchiedelUnitedKingdom thank you for your reply

  • @patrickcowan8180
    @patrickcowan8180 Před 3 lety

    Why isn't leca dry fill insulation used to insulate the stainless steel flexible liner?

    • @dominic6055
      @dominic6055 Před 6 měsíci

      I've read on another document of schiedel leca is used, but also I think they don't want to promote a cheap solution

  • @Droningonuk
    @Droningonuk Před 3 lety

    I can't believe this is all done by hand that explains why it's so expensive.

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 3 lety

      Hi. This is only part of the production line. We have a combination of manual and automation. Our Weil Flexistar machine automates a lot of the procedure. czcams.com/video/yFz3Jr3Ea38/video.html

  • @albarrowman3739
    @albarrowman3739 Před 3 lety

    I like the pictures with out an actours

  • @mbrew3244
    @mbrew3244 Před 3 lety

    Cool product. Is there a way to retrofit an insert. The background music is very soothing.

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 3 lety

      Hi. You should be able to retrofit an insert. A standard stove is freestanding under the chimney breast, so if the insert stove is fixed correctly then why not? :)

  • @likescars6210
    @likescars6210 Před 3 lety

    I have a cast in place old corroded 6" iron liner pipe in my chimney, they never capped the top and water has eroded it, do you think a professional could re line it using a 5" flexible liner, that is one inch smaller without having to remove the corroded one?

  • @freethoughtpolice6266

    Where can I find this music?

  • @LegitVoltron5739
    @LegitVoltron5739 Před 4 lety

    In the usa the chimney has to be two feet higher than the peak if it's within 12ft or something like that , do you have any roof supports for extending the flue higher above the roof ?

  • @Looking4lightning
    @Looking4lightning Před 4 lety

    Is there any reason that I can't use the liner and hook up directly to the furnace itself?

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 4 lety

      Hi. Sorry for the delay in replying, the main reason is that the heat from the top of the stove / furnace is too much and would melt or damage the flexible liner. For this reason, you always have a starting pipe and adaptor which is rigid.

    • @Looking4lightning
      @Looking4lightning Před 4 lety

      @@SchiedelUnitedKingdom even stainless?t316?

  • @Jason3249...
    @Jason3249... Před 5 lety

    Anyone know What sealant that is or is it fire cement 😀

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 5 lety

      Hi. According to our Installation Instructions: "The connection to the appliance should be made using fire cement/rope or high temperature sealant to ensure a positive seal. Where TecnoFlex Plus is to be fitted to the top of an open fire place, a Schiedel Rite-Vent gather unit should be fitted into the throat of the chimney connected to the TecnoFlex Plus and sealed off. When connecting Triplelock flex to a Schiedel Rite-Vent flue box, the flexible liner simply pushes directly on to the fast fix spigot. No sealant is required. When making a connection to a fluepipe in another product type, such as rigid stainless steel single or double wall or vitreous enamel, then the appropriate Schiedel approved connector to/from flexible should be used. The connector should be suitably sealed to the appliance spigot ensuring a gas tight joint." There are more details in our various Installation Instructions - www.schiedel.com/uk/chimney-and-flue-installation-instructions/

    • @Jason3249...
      @Jason3249... Před 5 lety

      Thank you for that info buddy 😀😎

  • @ventormaszynydoobrobkiplas9189

    Nice line!

  • @cianoreilly2163
    @cianoreilly2163 Před 5 lety

    Out of curiosity, why is it running at 45 degrees through the wall? Is it something to do with the draw? Could I drill the hole at 90 degrees and run the flue pipe through that?

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 5 lety

      Hi. Sorry for the late reply. It's preferable for an angle due to the draw, like you mentioned, but in our Installation Guide, on Page 6, you can see some examples at 90 degrees. We also have a document showing acceptable alternative connection methods. Both Installation Guide and Alternative Connection can be found here: www.schiedel.com/uk/products/steel-system-chimneys/icid/ - If you visit the page and scroll down, you will see Alternative and also Downloads.

  • @antonios4926
    @antonios4926 Před 5 lety

    I wish i seen this before i got the company to install my hideous chimney. Next time

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 5 lety

      Oh dear! Which chimney was installed?

    • @antonios4926
      @antonios4926 Před 5 lety

      Nothing as sophisticated as yours just plain single sheet ducting. I have painted it to camouflage it. Next one will be yours. Thanks for replying

    • @1974jrod
      @1974jrod Před 3 lety

      @@SchiedelUnitedKingdom where can I get one those angled wye tees in America?

  • @Mrzoo2021
    @Mrzoo2021 Před 6 lety

    Are the tiles porous and unglazed. Price per secton?

    • @SchiedelUnitedKingdom
      @SchiedelUnitedKingdom Před 6 lety

      Hi, Mr Zoo :) The ceramic liners are not glazed but are frost proofed. Regarding the cost per flue liner, 160mm I/d 7.75 euro per piece. 180mm I/d 8.45 euro per piece. 200mm 1/d 9.15 euro per piece. Give the Northern Ireland office a call on Tel: +44 1202 861650 for more details, or drop them an email here www.schiedel.com/uk/contact/ for any more info.