Solvent Sensitivity Testing MEK(methyl ethyl ketone) test
ASTM D 4752
Inorganic Zinc Coating
ASTM D 4752
Inorganic Zinc Coating
zhlédnutí: 37 957
Video
Dust test(ISO 8502-3)
zhlédnutí 21KPřed 5 lety
Elcometer 142 dust assement in accordance with ISO 8502-3
salt test (ISO 8502-9)
zhlédnutí 14KPřed 5 lety
measurement procedure for water soluble salts ISO 8502-9 PSPC
abrasive test(steel grit)
zhlédnutí 21KPřed 5 lety
abrasive test method method of measuring conductivity
Standard code btao yar
Please provide this format
Bang cara penggunaan conductivity nya ditutorial juga, saya lupa cara menghidupkan dan mengkonversikan ke 0 kembali😊
What is the purpose of discarding 10 ml
This is absolutely wrong. No gloves, drips and spills on the table = instantly done watching this. Never mind the other issues.
For epoxy also this test applicable?
No
Thanks for the informative video. I would like to ask if the magnifier has LED light or is it a normal one?
Has led in it
Can you share form all test pating file
MEK doesn’t dissolve that plastic container..? What kind of plastic is it I have to know now!
Where are your gloves
Nag tatagalog knmn ata tanga di mopa tinalog gago
IMO PSPC rule is for only chloride ? Or all soluble salts..what is x 1.2 or x 1.1?
Iso which stndard its
They are doing test according to ASTM D4940. if use ISO 11127-4,6 testing time will be 60 miniutes. Sample of abrasive & water have to take 100+100 ml.
@@JJJ-qx5gu 11127-4,6 both standards for non metallic abrasives right ? is there any other standard for metallic abrasives test in ISO?
8502-9
👍👍
This is wrong on last step. Rest of the procedures is okay. In that conductivity meter there are two sensors which is captured the exact reading. But this video he put only on single sencor.
I waiting for another testing
Good
You have to pull out solution only ..4times cycke i jectuon and every time have to settle up to3minutes rest then you pull into syringe and pour again.read the standard..your device show on micro zimens and your calculation doesnt seems right.however at start you need to use zero sokution based which is zero on device.you had wrong solution.its 3 to choose.
Thanks for the video but for the next time please use a better tape which you can remove it completely. You left part of the tape glue on the first test page.
)))
My contact no. 7618274103 whatsap
FInal reading will be the inital value of the distilled water subtracted from the filtrate measured value.
why do we discard the first 10ml?
I think it is in order to discard any floating non abrasive matter that can add conductivity to the test
Great information.. Is there any document about the calculation was made at the end? (6 x (actual value - reference value))
This people clearly poor and lack of studies in term of ISO 8502-6 and part 9...
@@tineshkumar6944 Explain please
That is 5 parts of 3ml because it's 15ml total x 1.2 to get mg/sqrd m ... 5x1.2x the difference... Which is 6 x the difference from before and after the test
@@tineshkumar6944 no
what u r doing is wrong u have check the substrate after rubbing not the cloth parae
I think he changed the cloth!!
Air entrapped was their while tapping distilled water inside patch, air should not be inside checking......Salt contamination.
how to download this video
Должен ведь ещё использоваться фильтр, разве нет?
Which the difference between iso 8502-6 and 8502-9?
Great information!!!