TORQ TCS Concrete Screws Pull Out Test
The concrete screws made by TORQ were tested on block work to reach a no failure load of 23 kN
zhlédnutí: 487

Video

Sympafix GT-C45
zhlédnutí 853Před 4 lety
Sympafix nail gun for Concrete and Steel. Can shoot up to 45MM nails. Safe and easy installation, wide range of compatible nails
TORQ Metal Drive in Anchor TMD
zhlédnutí 78Před 4 lety
TORQ all metal drywall anchor for quick installation into gypsum board and other board materials. No drilling required. Perfect for use in fire rated panels. Light to medium duty loads.
Torq Toggle Anchor KTA
zhlédnutí 438Před 4 lety
Torq toggle anchor KTA - Installation video
TORQ Concrete Screws - Easy Installation
zhlédnutí 501Před 5 lety
Perfect for edge protection fixing. FAST ECONOMICAL AND SECURE.
Sympafix Collated Drywall Screws
zhlédnutí 304Před 5 lety
Save time and money by using the Sympafix Collated Drywall Screws.
TORQ Wall Screw - Pull Out Test
zhlédnutí 1,3KPřed 6 lety
The TORQ Wall Screw being tested on hollow block, with an ultimate failure load of 12kN. Perfect for permanent fixings with quick installation times. www.torqfixings.com
TORQ Universal Nylon Plug - 4 way Expansion and Knotting
zhlédnutí 1,1KPřed 7 lety
The new TORQ Universal Nylon Plug with 4 way expansion and knotting capability will put you at ease when fixing onto any kind of substrate, be it concrete, hollow blocks or even drywall. Please visit our website www.helical-me.com for more such interesting products.
Mungo MHDA Pull out test
zhlédnutí 180KPřed 10 lety
The Mungo MHDA Hollow Ceiling Anchor put to the test. 25 kN load tension load applied, which lead to concrete cone failure.

Komentáře

  • @Problematica.
    @Problematica. Před 5 měsíci

    Nice, thank you very much!

  • @AlphatecEngineering
    @AlphatecEngineering Před 6 měsíci

    Very good video.Thanks

  • @aacmbirdzilla2343
    @aacmbirdzilla2343 Před 8 měsíci

    Thabks for the video, but I have a doubt, which norm did you follow to run this test?

  • @bjm574
    @bjm574 Před rokem

    how to calculate compressive strength of concrete

  • @Tech-zw8jc
    @Tech-zw8jc Před rokem

    Design Value Need how much KN / What is minimum Requirements

  • @jihanbhaiofficial
    @jihanbhaiofficial Před rokem

    How much is the price?

  • @danielcivil9967
    @danielcivil9967 Před 2 lety

    Thank you for sharing this video. I can use this video to show to the contractor what is pull-out test.

    • @zaheerh
      @zaheerh Před 2 lety

      Please do, glad to have been of help.

  • @222savvy
    @222savvy Před 2 lety

    good for medium weight items

  • @moussakalel
    @moussakalel Před 2 lety

    سعر و اماكن بيع ال pullout test ,?

  • @jalindardeshmukh3820
    @jalindardeshmukh3820 Před 2 lety

    India pune mrp?

  • @washingtonmina1576
    @washingtonmina1576 Před 3 lety

    Donde puedo sacar la licencia en new york ? Gracias

  • @koubertpurchasing5913

    do we perform this test on Philippines?

    • @zaheerh
      @zaheerh Před 3 lety

      Hello, unfortunately we are only based in Dubai. But I am sure there will be several agencies who can provide this test in the Philippines. Best bet is to contact the anchor manufacturers representative for your area.

    • @koubertpurchasing5913
      @koubertpurchasing5913 Před 3 lety

      @@zaheerh May I know the brand or model of the tester used?

  • @gnidnoeled786
    @gnidnoeled786 Před 3 lety

    @Zaheer Hussain What's the reading at the failure? What's your target force?

    • @zaheerh
      @zaheerh Před 3 lety

      Hello @gnid, we were trying to reach the ultimate load that the anchor can carry which in this case was about 23kN

    • @gnidnoeled786
      @gnidnoeled786 Před 3 lety

      @@zaheerh Thanks.

  • @coertdejong7724
    @coertdejong7724 Před 3 lety

    This is not a representative test. The cone is being pressed back by the test. This is a semi-confined testing situation.

    • @zaheerh
      @zaheerh Před 3 lety

      That’s is correct, but only to a certain extent. I will try and put out an explainer video soon

  • @saadaftab8127
    @saadaftab8127 Před 3 lety

    Hello, If anyone in Karachi want to do pull out test so kindly contact me

  • @syzyguskoyataki4610
    @syzyguskoyataki4610 Před 3 lety

    am looking for such a test in Kenya

  • @rohanjoshi6695
    @rohanjoshi6695 Před 4 lety

    What is the compressive strength of the specimen then?

  • @tommyodayiv9734
    @tommyodayiv9734 Před 4 lety

    Professional scaffolder.. whats the load at failure also what size anchor. sorry gauge isnt visible enough

    • @zaheerh
      @zaheerh Před 4 lety

      Hi Tommy, the failure load is 25kN, about 2500 kgs in a hollow core slab. Anchor tested was a internally threaded sleeve anchor with a trade name of MUNGO MHDA size M12.

    • @acbautocustoms4587
      @acbautocustoms4587 Před 4 lety

      @@zaheerh Hi Zaheer, so what is the required load you need to go thru in order to conclude that a concrete is strong enough and pass the test.

    • @zaheerh
      @zaheerh Před 4 lety

      @@acbautocustoms4587 hello, thank you for watching. In this video we aren't testing the strength of the concrete but actually testing a Mechanical anchor which is used in hanging MEP services. Its an expansion anchor which is specifically designed to be used in Hollow core slabs like the one you see in the video.

    • @zaheerh
      @zaheerh Před 4 lety

      Load at failure was about 25 kN or 2500 kgs approximately.

    • @acbautocustoms4587
      @acbautocustoms4587 Před 4 lety

      @@zaheerh is it only for anchor bolt break test? how about knowing the porosity or mix of concrete that will receive embedded anchor bolts to tell if its a good concrete or not capable to receive mechanical fasteners?

  • @TheDees007
    @TheDees007 Před 5 lety

    Can this equipment do a shear load test on 12mm chemical anchor bolt at 12kn without damaging the strength of the bolt.

    • @zaheerh
      @zaheerh Před 4 lety

      Shear load tests are not possible with this kind of testers. They can apply only a tensile load or pull out load.

    • @TheDees007
      @TheDees007 Před 4 lety

      How do you do a tensile load test

    • @ElectronPower
      @ElectronPower Před rokem

      @@TheDees007 It's shown in this video.

  • @measuringtools5301
    @measuringtools5301 Před 5 lety

    Where to buy this item ?

  • @puprilla
    @puprilla Před 6 lety

    thanks for the video!! about to go do this to a metal roof and wanted to make sure i knew what i was doing

  • @sindalisindi1442
    @sindalisindi1442 Před 7 lety

    Thank u for the video is there any standard that specify which max load to apply for epoxy anchor bolts on foundations?

  • @dannyzuanafrizal8752
    @dannyzuanafrizal8752 Před 7 lety

    is that M10 anchor?

    • @zaheerh
      @zaheerh Před 7 lety

      Danny Zuan Afrizal Yes Danny, we tested a M10 anchor

  • @carlomarcial3
    @carlomarcial3 Před 7 lety

    Weak Concrete.

    • @Mark-sn6kh
      @Mark-sn6kh Před 7 lety

      Strong anchor.

    • @thatguywiththeface1741
      @thatguywiththeface1741 Před 6 lety

      Concrete has almost no tensile strength. It's designed to have all of its strength dedicated to compressive loads. That's why concrete is always reinforced with rebar and/or mesh, to add to it's tensile strength.

  • @zaheerh
    @zaheerh Před 7 lety

    Hi John, this is a tension load test, also known as a pull out test. The product being tested here is a internally threaded anchor fastnerer designed to be used in precast hollow core slabs. A hydraulic jack is used to apply the load onto the anchor. The purpose of this test is to check the ultimate failure load of the anchor. In the case of the anchor being tested for this particular video the substrate, hollow core slab, failed at a load of 25kN

    • @jimdiet8534
      @jimdiet8534 Před 3 lety

      Basically the anchor is as as good as the substrate?

    • @zaheerh
      @zaheerh Před 3 lety

      @@jimdiet8534 In this case, Yes. However, there are times when the anchor fails too

  • @cyrusIIIII
    @cyrusIIIII Před 7 lety

    Anybody can tell me what is the purpose of this test?

    • @zaheerh
      @zaheerh Před 7 lety

      Hi John, this is a tension load test, also known as a pull out test. The product being tested here is a internally threaded anchor fastnerer designed to be used in precast hollow core slabs. A hydraulic jack is used to apply the load onto the anchor. The purpose of this test is to check the ultimate failure load of the anchor. In the case of the anchor being tested for this particular video the substrate, hollow core slab, failed at a load of 25kN

    • @cyrusIIIII
      @cyrusIIIII Před 7 lety

      Zaheer Hussain Thank you very much.

    • @dingdongchingchong8659
      @dingdongchingchong8659 Před 4 lety

      @@zaheerhDid the anchor fail? I saw the concrete fail

  • @numankhan326
    @numankhan326 Před 8 lety

    nice

  • @heightlistsafety3556
    @heightlistsafety3556 Před 9 lety

    That is a Hydrajaws Model 2000 Tester. Type Hydrajaws into Google.

    • @katarmalnanji
      @katarmalnanji Před 6 lety

      www.kaizenmetals.com/ ANY BRASS PRODUCT REQUIRED CONTACT US

  • @kennyattai1988
    @kennyattai1988 Před 9 lety

    Where did you purchase the pull testing device?