Precision Zone TV Channel provides an in -depth look into our approach and methodologies of providing advanced industrial electronics services. From testing methodologies, repair process, quality control, customer satisfaction, to our outlook on industry trends and developments. Stay tuned with us!
Precision Zone Drone Tour!
Take a tour of Precision Zone!
A unique and awesome drone video tour of our entire facility.
Incredible video work by Mikhail Choumiatsky & Anthony La Rosa!
A unique and awesome drone video tour of our entire facility.
Incredible video work by Mikhail Choumiatsky & Anthony La Rosa!
zhlédnutí: 97 168
Video
MRS-10 Machine Tending Cart with Colombia Metal Spinning
zhlédnutí 82Před rokem
This video shows the Precision Zone MRS-10 Machine Tending Cart. The cart features an HC-10DT collaborative robot tending a Haas CNC lathe. The collaborative robot is equipped with advanced safety features that allow it to work safely alongside humans. The robot is able to quickly and accurately tend the CNC lathe, ensuring maximum productivity and efficiency. It is also highly adaptable, allow...
Machine Tending Application developed by Precision Zone
zhlédnutí 166Před rokem
This machine-tending application is designed to automate the process of engraving parts. An Epson VT6-L six-axis robot first uses its vision system to detect the parts at an arbitrary orientation, then moves them to the HBS Rotary Table Laser Engraver to engrave the required markings. Once the engraving is complete, the robot then palletizes the finished parts for shipping or storage. This auto...
Epson SCARA Soldering Robot
zhlédnutí 1,5KPřed 3 lety
A quick overview of our robotic soldering cart powered by the EPSON T3 SCARA Robot and HAKKO Robotic Soldering system.
Yaskawa MotoMini Press Tending Robot
zhlédnutí 1,6KPřed 3 lety
Press Tending Robot Workcell powered by Yaskawa Motoman MotoMini robot
A brief introduction to our Robotic Soldering Station
zhlédnutí 732Před 4 lety
We are authorized GennFlex distributors and carry their entire line of robotic and automation solutions. Today, we are presenting our new Robotic Soldering Station powered by the Epson VT6 robot and Hakko soldering module.
EIS AIMS Dispense Video
zhlédnutí 150Před 7 lety
The Advanced Inventory Management Solution provides control over your inventory and allows easy access to your various items. AIMS Dispense provides superior contamination protection and advanced theft prevention. Cloud based management gives the user ability to track usage information as well as allowing for collecting cost information for materials. This advanced management system helps autom...
CENTROID HAAS Renishaw ballbar test
zhlédnutí 2,3KPřed 7 lety
In this video, we show a brief demonstration of a Renishaw ballbar test on a Haas VF-1. The ballbar test is a simple to use test that generates a large amount of information about a machine's tool positioning performance. Performing a ballbar test is important to ensure that the CNC machine is making accurate parts and to reduce potential scrap parts. The necessary tools are the ballbar itself ...
CNC Electric Motor Bearing Housing Repair
zhlédnutí 5KPřed 7 lety
Here at Precision Zone, we offer electric motor bearing housing repair completed in-house. We use a Toyoda Stealth 1165 CNC machine to precisely rework and create ODE and DE housings for various AC spindle, AC servo, AC standard induction, and DC servo motors. The entire process can be completed while keeping the material in the machine, taking out the factor of human error and increasing produ...
Yaskawa AC Servo Motor SGMGH Series Alarm Codes
zhlédnutí 6KPřed 7 lety
The experts at Precision Zone specialize in servo motor repair and can help get your Sigma II motor back up and running quickly. We specialize in troubleshooting and repairing SGMGH motors and diagnosing problems pertaining to common motor alarms. Common alarms pointing to an issue with the motor are overcurrent or ground fault alarm (A.10), overload (A.71, A.72), and overspeed (A.51). Encoder ...
Yaskawa AC Servo Motor SGMGH Series overview
zhlédnutí 2,2KPřed 7 lety
Yaskawa's Sigma II series of motors range come in both a 200V and 400V offering. These motors are distinguished as Sigma II series by the leading SGMGH in the motor model number. These motors have power ratings from 500W all the way up to 15kW. Additionally, these motors can be equipped with 17 bit incremental or absolute encoders. For purchase or repair inquiry of an SGMGH motor, give us a cal...
Yaskawa AC Servo Motor SGMGH Series Static Check
zhlédnutí 11KPřed 7 lety
Here at Precision Zone we offer refurbishing and reconditioning of Yaskawa SGMGH Sigma II series AC servo motors. In order to ensure where some issues stem from, we offer troubleshooting steps and procedures which can be performed on-site to help speed up the process of getting back up and running. For these motors, one of the first tests to perform is a megaohm test using a megohmmeter. These ...
BENSHAW MX Series Start Up Review
zhlédnutí 1,9KPřed 7 lety
Precision Zone has partnered with one of the leading motor control manufacturers Benshaw. This video serves as a guide for navigating the display for Benshaw MX series inverters. The easy to read screen displays output diagnostics and allows for parameter editing and verification. Some of these values given by the display are voltages, currents, power, and frequency among many other important d...
BENSHAW MX Series Default Screen Monitoring Mode
zhlédnutí 732Před 7 lety
Benshaw MX Series Solid State Starters use a default screen which monitors certain readings of the unit. It shows when the unit is in a ready state, what the current mode is (running or stopped), average amps, and average voltage of the unit. The voltage being monitored is the incoming voltage, not the voltage being output from the starter unit. Using the up and down arrow keys, one can cycle t...
BENSHAW MX series Quick Start
zhlédnutí 6KPřed 7 lety
Precision Zone has partnered with one of the leading motor control manufacturers Benshaw. Benshaw MX devices offer quick and easy initial setup through a quick-state menu. This menu contains the most important parameters that are required to set appropriately before running the unit, though they should all be checked to be set correctly for seamless integration. There are 6 different menus that...
Magnetek Crane Inverter Drive G+/ VG+ Series 4 Overview
zhlédnutí 863Před 7 lety
Magnetek Crane Inverter Drive G / VG Series 4 Overview
Magnetek Crane Inverter Drive G+/ VG+ Series 4 Alarm Codes Review
zhlédnutí 2,3KPřed 7 lety
Magnetek Crane Inverter Drive G / VG Series 4 Alarm Codes Review
Magnetek General Purpose Inverter Drive GPD505 506 Overview
zhlédnutí 431Před 7 lety
Magnetek General Purpose Inverter Drive GPD505 506 Overview
Magnetek General Purpose Inverter Drive GPD333 Overview
zhlédnutí 470Před 7 lety
Magnetek General Purpose Inverter Drive GPD333 Overview
Magnetek General Purpose Inverter Drive GPD333 Alarm Codes Review
zhlédnutí 424Před 7 lety
Magnetek General Purpose Inverter Drive GPD333 Alarm Codes Review
Magnetek General Purpose Inverter Drive GPD505 506 Static Check
zhlédnutí 830Před 7 lety
Magnetek General Purpose Inverter Drive GPD505 506 Static Check
Magnetek General Purpose Inverter Drive GPD505 506 Alarm Codes Review
zhlédnutí 1,4KPřed 7 lety
Magnetek General Purpose Inverter Drive GPD505 506 Alarm Codes Review
Magnetek Crane Inverter Drive G+VG+ Series 3 Static Check
zhlédnutí 1,1KPřed 7 lety
Magnetek Crane Inverter Drive G VG Series 3 Static Check
Magnetek Crane Inverter Drive G+VG+ Series 3 Alarm Codes Review
zhlédnutí 650Před 7 lety
Magnetek Crane Inverter Drive G VG Series 3 Alarm Codes Review
Magnetek Crane Inverter Drive G+VG+ Series 3 Overview
zhlédnutí 223Před 7 lety
Magnetek Crane Inverter Drive G VG Series 3 Overview
Magnetek Crane Inverter Drive P3 Series 2 Static Check
zhlédnutí 137Před 7 lety
Magnetek Crane Inverter Drive P3 Series 2 Static Check
Magnetek Crane Inverter Drive P3 Series 2 Overview
zhlédnutí 257Před 7 lety
Magnetek Crane Inverter Drive P3 Series 2 Overview
Magnetek Crane Inverter Drive P3 Series 2 Alarm Codes Review
zhlédnutí 426Před 7 lety
Magnetek Crane Inverter Drive P3 Series 2 Alarm Codes Review
Cómo puedo revisar el regenerativo me está marcando un error rr
Nice
We have an alarm on a Matsuura machine with Yaskawa Varispeed 626M5 drive for the spindle, the converter shows -U and the inverter -b, the alarm is the number 6302 ¨communication of the spindle temperature monitor system is abnormal¨ , could you give us an idea of what the problem could be?
What is the purpose of winding resistance test !
Can you clean the starter in the way that you show while it is still on the engine? Or do you have to remove it?
I want to see you the show about inwater but fan warning ok now !
show how to connect the motor Fanuc A06B-0186-B675#0014 2000RPM 3.8kW Motor to a wood lathe so that the spindle is like a rotary axis and which controller is suitable or replace with another cheaper one
Hola, el video parece bueno, pero sería mucho mejor si lo traduce al español o castellano, llegaría a ser más interesante
Làm thế nào để coppy thông số từ biến tần cũ sang mới dòng is7
Very cool, I'm jealous of all the amenities!
Can a AC servo generate holding torques same as stepper ?
need high speed motor setting parameter
Sir, can I ask for your help on how to set up the Yaskawa CACR -HR01BAB12 servo driver and USAREM 01CSNK servo because I just bought a used one and don't know that this type is too old and I'm still a beginner, thank you
Can I know where the tolerance standards come from? ISO?
Comment faire pour installer le prise
How to find the pin i have to supply 25 to 90 volt
24 or 19 v
Hi. How to unlock parameters long word in OSP5000?
هل يدعم يوبي اس
Alarm 101 atinya apa
Can you tell me more about fault 1, I have this number alarm in our servo pack driver but cables of servo are ok
Well now I know how to tear a perfectly good motor with nothing wrong with it. I’d think if you really wanted someone to learn something you’d just us the demonstration on a motor that needs replaced or repaired, but with that being said it almost leads me to believe that your motors are so reliable they never go bad or you don’t know how to properly troubleshoot a damaged motor. Either way horrible demonstration
model CIMR- P5C42P2 help me how i configure
model CIMR- P5C42P2 help me to configure this model
Thank you for video
Place help me Alam 410
Alarm 410?
HELLO HOW WE CAN COPY AND PASTE PARAMETRES FROM 616G3 TO UN OTHER ONE ? GREETINGS
Nice
Can you check the HV-75 AP4 in the machine with power off then on
Can you please be so kind to guide, where is DC fuse is located?
How can I joint VFD LS-si7 with digital potentiometer EDP2041
I am Vietnamese. can you give me some panasonic servo repair documents. Thank you very much
Hi, 1 question. I get alarm code A.C3 The manual explain: "Wiring in encoder phase A or B is disconnected". But. I tested the wire and don't problem. Then, the fault is? Thanks for your help.
Are there online manuals available for this piece of test equipment? Also, looking for UL or some other Testing Laboratory certification for the test cart.
bulshet video
👍
Helo I vietnam my
Don't you just hate it when people leave trunking lids off in panels.
Why alarm oPE05
Encoder ke bare me 1vedio pls
Hi SGDB-20ADS is showing alaram. There is no keypad. How will we know what is the error for.? Pls help
Hi Do you have a facebook account?
How to check OH ALARM
Hi. Rob. Thanks so much for your super test and explanations!!!! God bless you and precision zone.
Elevator data. I veen having this fout every day.
hi sir can you explain if what happen the motor if braking unit is defective because in hoisting crane first speed until 4th speed the motor is vibration until 4th speed but no have heat in going of resistor and no have fault in yaskawa vfd the problem only the vibration.
Does a single phase servo motor work without a capacitor and without future problems??
Hi I am facing error AF6 ,AF10
hello, I need your help to maintain the data where the battery is located (sgdv-7r6a01a )
👍