Both A/C units stop cooling for the holiday.
Homeowner loses both a/c units on Friday before the Holiday weekend. #hvac #airconditioning #airconditioner #cooling #hvaclife #hvacrepair #hvactechnician #hvactraining #hvacservice
zhlédnutí: 3 600

Video

Going back to correct a mistake, thanks to a viewer.
zhlédnutí 1,2KPřed 21 hodinou
Thanks to viewers and I was able to go back and correct a diagnosis before we made the wrong repair. #hvac #hvaclife #airconditioning #airconditioner #cooling #hvacservice #hvactechnician #hvacrepair
Second opinion on HVAC issues.
zhlédnutí 1,5KPřed dnem
Things will change when your trusted local company sells out to the bid national raiders. #hvac #hvaclife #airconditioning #airconditioner #hvacservice #hvactechnician #cooling #hvacrepair #heatingandcooling #heating #smallbusiness #homeownership
Clogged A/C drain line.
zhlédnutí 527Před 14 dny
A/C drains clog easy and sometimes need air vents to drain properly. #hvac #airconditioning #airconditioner #hvacmaintenance #hvaclife #drain #hvactechnician #hvactraining #diy #homeowner #cooling #heating
HVAC service call turns into a training video.
zhlédnutí 2,3KPřed 14 dny
A few pointers on troubleshooting Trane systems. #hvac #hvaclife #hvacservice #hvacrepair #hvactechnician #heatingandcooling #airconditioner #hvactech #hvactraining #
Poor ventilation causes mold issue.
zhlédnutí 749Před 21 dnem
Improper bathroom exhaust fan installs can cause problems. #airconditioning #airconditioner #cooling #hvaclife #hvac #venting #mold #hvactechnician #hvactraining #hvacservice #heating #hvacrepair #homeownership #bathroom
At least I replaced the right part.
zhlédnutí 1,3KPřed 28 dny
AN EASY CALL CLOSE TO HOME. #hvaclife #hvac #airconditioning #hvacservice #airconditioner #cooling #hvactech #hvactechnician #hvacrepair #heatpump
A/C coils freezing, not cooling, and a water stain
zhlédnutí 1,3KPřed měsícem
A/C unit freezing, not cooling, and a water stain. #hvac #airconditioning #airconditioner #hvacservice #hvaclife #ac #hvactechnician #hvacrepair
Another HVAC system not cooling from sensor issues.
zhlédnutí 1,7KPřed měsícem
Temperature sensor failures are becoming more common with HVAC systems. #hvac #hvaclife #airconditioning #ac #airconditioner #coolingsystem #cooling #heatpump #hvactech #hvacservice #hvacrepair
A/C system not cooling and making noise.
zhlédnutí 1,3KPřed měsícem
A/C system not cooling and making noise.
Mileseey TP2 PLUS Thermal Imager and uses in HVAC.
zhlédnutí 2KPřed měsícem
Mileseey TP2 PLUS Thermal Imager and uses in HVAC.
A/C keeps running with the thermostat off.
zhlédnutí 1,9KPřed měsícem
A/C keeps running with the thermostat off.
Trane Link Communications.
zhlédnutí 1,5KPřed měsícem
Trane Link Communications.
Blows cold but not cooling..
zhlédnutí 2,8KPřed měsícem
Blows cold but not cooling..
Cooled better before the coil was replaced.
zhlédnutí 2,8KPřed 2 měsíci
Cooled better before the coil was replaced.
Bryant Heat Pump loses its cool.
zhlédnutí 1,9KPřed 2 měsíci
Bryant Heat Pump loses its cool.
Trane Micro Channel coil LEAK REPAIR on site!
zhlédnutí 1,5KPřed 2 měsíci
Trane Micro Channel coil LEAK REPAIR on site!
Trane A/C system control issues.
zhlédnutí 1,8KPřed 2 měsíci
Trane A/C system control issues.
Trane Compressor Temperature 291 Degrees while not running.
zhlédnutí 1,7KPřed 2 měsíci
Trane Compressor Temperature 291 Degrees while not running.
No Cooling, Heat strips on, Mismatched system, Wrong metering device, No permit, Hackery!
zhlédnutí 6KPřed 2 měsíci
No Cooling, Heat strips on, Mismatched system, Wrong metering device, No permit, Hackery!
Heatwave is exposing the leaking air conditioners.
zhlédnutí 1,7KPřed 2 měsíci
Heatwave is exposing the leaking air conditioners.
Just when you think it's an easy Cap and go!
zhlédnutí 2,3KPřed 2 měsíci
Just when you think it's an easy Cap and go!
39 yr old Carrier! Will it live another day?
zhlédnutí 1,1KPřed 2 měsíci
39 yr old Carrier! Will it live another day?
HVAC inverter is not cooling.
zhlédnutí 2KPřed 2 měsíci
HVAC inverter is not cooling.
A common problem with new HVAC systems these days.
zhlédnutí 2,5KPřed 2 měsíci
A common problem with new HVAC systems these days.
Just be honest and accurate with your diagnosis. #hvac #hvaclife #hvacrepair
zhlédnutí 1,4KPřed 3 měsíci
Just be honest and accurate with your diagnosis. #hvac #hvaclife #hvacrepair
HVAC refrigerant safety.
zhlédnutí 1KPřed 3 měsíci
HVAC refrigerant safety.
I don't think it's leaking.
zhlédnutí 722Před 3 měsíci
I don't think it's leaking.
Zoning will kill your system.
zhlédnutí 1,6KPřed 3 měsíci
Zoning will kill your system.
Get all of your options!
zhlédnutí 1,3KPřed 3 měsíci
Get all of your options!

Komentáře

  • @eastcoast186
    @eastcoast186 Před 2 hodinami

    Wish you well

  • @TheLovey22
    @TheLovey22 Před 8 hodinami

    I’ve been experiencing issues with my HVAC filters bending and creating air gaps, allowing dust into the house. I've already tried switching back to more restrictive filters, but the problem persists. Could a dirty blower be causing increased suction or airflow issues, making my filters bend? Would cleaning the blower help resolve this?

  • @hvacman954
    @hvacman954 Před 9 hodinami

    Nothing like that H-10

  • @dakotadingo9083
    @dakotadingo9083 Před dnem

    Did you really say "maybe a little refrigerant"??? My guy. Blowing lines ain't no de mitimus release....

  • @boywhohadatiger
    @boywhohadatiger Před dnem

    That’s a ridiculously low amount of cfm. I’d like to see them add reheat into systems for that

  • @timothymercer3526
    @timothymercer3526 Před dnem

    Push comes to shove you can always put a spade bit or a spring bit on a snake and it will also remove it when the air line doesn't do it...

  • @MarkCarpenterHVAC-me2jg

    i'm with you brother, Its been me in the dog all week. Sore throat on Saturday hit hard on Labor Day, test positive Tuesday AM. I still tested positive yesterday. I will probably go back on monday, they won't let me back till I have a negative test.

  • @techfive7202
    @techfive7202 Před dnem

    Thank you! Anytime I get a call for one of these, it's 11pm. I'm worn out and no help is available. I like your channel the most because you actually do and explain more complex issues.

  • @davidsantana9510
    @davidsantana9510 Před 2 dny

    No clamps connected And you know that. And sounds like a compressor is running backwards

  • @emoneyblue
    @emoneyblue Před 2 dny

    Hope you get better soon

  • @CHRISDOESHVAC24
    @CHRISDOESHVAC24 Před 3 dny

    You needed to get a sludge hammer and beat the RV a little bit more 😂 amp draws are good discharge temp is hot sounds like they installed the RV didn’t protect the valve and fucked it up good job bro those ones are tough

  • @user-su5ft8lc9q
    @user-su5ft8lc9q Před 3 dny

    Why would you have your dog around you when you have Covid.

  • @nightranger9795
    @nightranger9795 Před 4 dny

    Look at the swamp against the foundation

  • @thomasmarshall7795
    @thomasmarshall7795 Před 4 dny

    Do your homework Labor Day is a communist holiday adopted by Democrats for our country. Learned that in high school.

  • @punksprovids
    @punksprovids Před 4 dny

    assuming this is in cool mode?

  • @rongray4118
    @rongray4118 Před 4 dny

    Would have saved the water for the Off Grid Battery Bank too!

  • @USA-GreedyMenOfNoIntegrity

    Get yourself a sharpie. Start writing the date and what you do on each unit. Use shorthand if you need to. It makes it nice to pull off the cover and see what’s been done in the past. Also write a baseline for all your numbers, capacitance, pressures, temperature, etc. if I didn’t put your system in, I’m not going out after hours, on the weekend and especially not on a holiday. Get the jackleg who put it in to come out.

  • @ricklong3218
    @ricklong3218 Před 5 dny

    It's on the manufacturer that they don't color code things properly! The fact that you were honest and came out to double check says VOLUMES! Good to know there are honest techs, and honest companies, out there willing to eat the crow! 👍 👍

  • @tedhicks5431
    @tedhicks5431 Před 5 dny

    Good ole basic units

  • @Ant-fq3yi
    @Ant-fq3yi Před 5 dny

    Amrad and Mars is where its at those cheap Mexico, Korean, Chinese caps suck and cant handle heat for a year.

  • @davidwarren2331
    @davidwarren2331 Před 5 dny

    I would lose cooling because my coils were dirty.4 hours then it stops being cool...my filter is 22 x 22...i needed a 24x24 ..all the hairs was getting into the coils.Cleaned that..Cooling restored.

  • @realSamAndrew
    @realSamAndrew Před 6 dny

    I never agreed with the name Run Cap Bandit. It doesn't really mean what it's supposed to mean. Even so, our friend in the other Carolina uses it for the ones who mount it in the box with no bracket. That's not you. And your technique is perfectly fine in any professor's book.

  • @10speed4
    @10speed4 Před 6 dny

    I suspect the home took a power surge or a power sag.

  • @MariosACandRefrigeration

    You do not need the low loss fittings,if you have good seals on the proves,and I would not use one on the low side.2 cents.

  • @eastcoast186
    @eastcoast186 Před 6 dny

    Thanks enjoy your weekend and holiday thanks for your service to our great country 🇺🇸🇺🇸🇺🇸🇺🇸🇺🇸🇺🇸

  • @robbo219
    @robbo219 Před 6 dny

    Right now I’m without my AC until Tuesday. Lennox system with a leaking coil-again (second replacement since 2020). Last year it was the compressor. I have one more year left on the warranty.

    • @myHVAClife
      @myHVAClife Před 6 dny

      Not just Lennox. they all have coil issues these days. Hope it all works out.

    • @jaygunter3828
      @jaygunter3828 Před 6 dny

      That sucks, sorry to hear that.

    • @yappering
      @yappering Před 6 dny

      Get it replaced under warranty

    • @davidwarren2331
      @davidwarren2331 Před 5 dny

      Check your evaporator coils..could be full of hairs

    • @bobboscarato1313
      @bobboscarato1313 Před 4 dny

      Lennox used to patch up systems long ago. I switched brands way back then!

  • @bryanalbright3019
    @bryanalbright3019 Před 6 dny

    Goodman....Model T of a/c. They are easy too. Duck tape and bailing wire. 🎉

  • @misterindependent7994

    I have those same gauges. Mine leaked right out of the box and I send them to the manufacturer and they sent them back still leaking. Now I never trust my vacuum.

  • @dennisgill3618
    @dennisgill3618 Před 6 dny

    Like others have said, get the appion core depressors. Worth the money.

  • @Pakulika26
    @Pakulika26 Před 6 dny

    I just had an Oxbox heat pump installed. My thermostat has 6 wires but the oxbox has 4 wires. How do i wire my existing 6 wires to the new heat pump? I have an electric air handler for emergency heat.

  • @davidvannorsdall899

    thank you. sincerly supper rookie

  • @larrydysondev
    @larrydysondev Před 7 dny

    bob smith CA glue....problem solved.

  • @Science_Unified_Field

    Is not better to replace it? or is more profitable to repair it?

  • @Science_Unified_Field

    Very good job bro. God bless u

  • @210balla210balla1
    @210balla210balla1 Před 7 dny

    U ain't put the clamps on it's a bad capacitor

  • @DonaldMeredith-i4o
    @DonaldMeredith-i4o Před 8 dny

    Did he say to blow refrigerant to clear a drain? Are you kidding me? Let's just use some R600 why don't we, and use your torch to look up the pipe to make sure you got the clog clear.

  • @mikemoseley8711
    @mikemoseley8711 Před 8 dny

    We all make mistakes but it’s what you do to make it right. And we learn from our mistakes.

  • @daleborg9070
    @daleborg9070 Před 8 dny

    I don't know if it makes a difference but I noticed on the first video you installed the pressure probes and then you turned them on. I thought you were supposed to turn them on and then attach the probe to the port. Good videos, keep them coming.

  • @Paul-IE-Repairs
    @Paul-IE-Repairs Před 8 dny

    those look like C&D core depressors

  • @markcotter2355
    @markcotter2355 Před 8 dny

    happens to the best of us, good catch though. lucky the customer let you re check. Crappy cheap POS. low loss fitting. I have good luck with yellow jacket ones. Go yellow.

  • @andreeriner811
    @andreeriner811 Před 8 dny

    Ok, again, the more I think about it, I believe somebody added Freon after you checked it. Either the customer didn’t know they did, or he didn’t want to tell you he had someone else out there I guarantee

  • @marksanders6772
    @marksanders6772 Před 8 dny

    Shop Vac

  • @andreeriner811
    @andreeriner811 Před 8 dny

    Brother we’ve all been there and done that. I’m wondering about your low loss fittings however I use them all the time I’ve never had any problems is it possible you just didn’t have them screwed on tight enough?. I’ve caught myself being cautious about over tightening them. I DO wonder however if someone did add Freon over the weekend. I’ve had weired stuff happen like that.

  • @chesstime356
    @chesstime356 Před 8 dny

    No matter of what you are one of the honest and top technician

  • @briancarlisi2224
    @briancarlisi2224 Před 8 dny

    I use the same CPS fittings w/ out realizing any issues. Next time I get jacked up readings I’ll be sure to remove and check readings without the CPS. Nice heads up. Thanks!

  • @RobertTuck-vo8cw
    @RobertTuck-vo8cw Před 9 dny

    I would not have charged him anything for the second call. And I would have replaced the contactor for free as a gesture of goodwill.

    • @myHVAClife
      @myHVAClife Před 8 dny

      I Did not charge for the return trip.

  • @MariosACandRefrigeration

    Always turn on proves on 0 out ,then connect.2 cents.

  • @LouisS-cs7bh
    @LouisS-cs7bh Před 9 dny

    My question is: what recourse does the owner have with the large national company trying to take advantage of him? How in the world can they get away with this kind of business practices?

    • @myHVAClife
      @myHVAClife Před 8 dny

      He can complain to them, but not much else. Maybe ask for a refund on their service.

    • @LouisS-cs7bh
      @LouisS-cs7bh Před 8 dny

      @@myHVAClife Or sue for fraud.

  • @realSamAndrew
    @realSamAndrew Před 9 dny

    It sucks when they charge in many cases insane prices for those tools, and they screw up that bad.

  • @MariosACandRefrigeration

    Something was off, you had a good delta.