Cosmin Nita
Cosmin Nita
  • 62
  • 1 759 618
Resideo: detector de inundatie L1 wifi si vana de inchidere L5 wifi
Resideo: detector de inundatie L1 wifi si vana de inchidere L5 wifi - scurta demonstratie de functionare #WeAreResideo
Alte filme pe canalul meu CZcams:
Evohome binding with HCC80 Incalzire in pardoseala Underfloor heating HCE80 (English subtitles)
czcams.com/video/b8W9M7Gy4QU/video.html
Tutorial Honeywell Home VC zone valves - vane de zona VC (English subtitles)
czcams.com/video/WHRrDf8CYw4/video.html
Termostatul wireless Honeywell Home T6R (Lyric) cu comanda prin internet
czcams.com/video/d9ujUBrW97Q/video.html
zhlédnutí: 426

Video

Tutorial Honeywell Home VC zone valves - vane de zona VC
zhlédnutí 2,6KPřed 2 lety
Tutorial Honeywell Home VC zone valves - vane de zona VC. #WeAreResideo Honeywell Home, Smart Thermostat, Smart Zoning Opiniile prezentate sunt ale mele și nu reprezintă punctul de vedere al Resideo. The views presented are my own and do not represent those of Resideo. 0:00:00 Introducere / Introduction 0:00:32 Tipuri de vane si servomotoare VC / Types of VC zone valves and actuators 0:01:36 Mo...
Honeywell Home - V2000SX si Thera 6, noua gama de robineti si capete termostatice #WeAreResideo
zhlédnutí 1,5KPřed 3 lety
Honeywell Home - V2000SX si Thera 6, noua gama de robineti si capete termostatice: construită în Europa de o companie cu experiență de 45 de ani în fabricarea de robineți termostatici #WeAreResideo Capul termostatic Thera-6: garantie 10 ani • Design modern, minimalist și compact • Senzor premium de construcție germană • Design durabil cu carcasă din plastic care nu se îngălbenește • Cea mai bun...
Evohome binding with HCC80 Incalzire in pardoseala Underfloor heating HCE80 (English subtitles)
zhlédnutí 17KPřed 3 lety
Evohome binding with HCC80 incalzire in pardoseala Underfloor heating HCE80, how to bind Evohome to HCE80/HCC80 #WeAreResideo Honeywell Home, Smart Thermostat, Smart Zoning Opiniile prezentate sunt ale mele și nu reprezintă punctul de vedere al Resideo. The views presented are my own and do not represent those of Resideo. 0:00:00 Introducere/ Introduction 0:01:05 Configurare preliminara. Impere...
Detectorul de inundatie si inghet wi-fi Honeywell Home W1 #WeAreResideo
zhlédnutí 854Před 4 lety
Detectorul de inundatie si inghet wi-fi Honeywell Home W1, termostatul inteligent T6/T6R (Lyric) si camera de supraveghere wi-fi C2. Smart Home de la Resideo. #WeAreResideo Opiniile prezentate sunt ale mele și nu reprezintă punctul de vedere al Resideo Site-ul GetConnected - informatii utile getconnected.honeywellhome.com/ro/ Termostatul wireless Honeywell Home T6R (Lyric) cu comanda prin inter...
Honeywell Home XS100 - detector de fum, protectie la incendiu
zhlédnutí 1KPřed 4 lety
Honeywell Home XS100 - detector de fum, protectie la incendiu; salveaza vieti prin alarmarea in cazul unui inceput de incendiu. Detinerea unui detector de fum functional reduce la jumatate sansele de deces intr-un incendiu. 10 ani garantie, 10 ani durata de viata. XH100 - detector de caldură - ideal pentru bucătării si băi XS100 - detector optic de fum - ideal pentru dormitoare si camere de zi ...
Termostate Honeywell Home - parametrii avansati si algoritmul inteligent TPI #WeAreResideo
zhlédnutí 28KPřed 4 lety
Termostate Honeywell Home - parametrii avansati si algoritmul inteligent TPI. Filmul este organizat pe capitole, link-urile acestora se găsesc mai jos. Clic pe butonul Show more / Arată mai mult. Filmul cuprinde termostatele Honeywell Home DT92, CMT727, T3R, Round, T6R (Lyric). #WeAreResideo Opiniile prezentate sunt ale mele și nu reprezintă punctul de vedere al Resideo. The views presented are...
Termostatul wireless Honeywell Home T6R (Lyric) cu comanda prin internet #WeAreResideo
zhlédnutí 24KPřed 4 lety
Termostatul wireless Honeywell Home T6R (Lyric) cu comanda prin internet, algoritm inteligent TPI (Timp - Proportional - Integral). Fabricat in Marea Britanie. #WeAreResideo Opiniile prezentate sunt ale mele și nu reprezintă punctul de vedere al Resideo. The views presented are my own and do not represent those of Resideo. 0:00 Introducere 0:37 Continutul cutiei 01:39 Recomandari pentru evitare...
Honeywell T3R - noul termostat wireless programabil #WeAreResideo
zhlédnutí 20KPřed 5 lety
Honeywell T3R - noul termostat wireless programabil și Honeywell T3 (varianta cu fir) au fost lansate în România în aprilie 2019 și sunt fabricate în Marea Britanie. #WeAreResideo La fel ca celelalte termostate digitale Honeywell, T3/T3R nu au histerezis și funcționează cu algoritm inteligent TPI (Timp - Proporțional - Integral), care asigură temperatură constantă în încăpere (deci confort term...
Resideo - cine suntem #WeAreResideo
zhlédnutí 589Před 5 lety
Resideo - cine suntem, Resideo - who we are, termostat wireless Round cu comanda prin internet, termostat wireless Lyric / Honeywell Home T6R cu comanda prin internet, Kombi-QM, Kombi-TRV, D06F, D15S, vane si servomotoare, sistem zonare Evohome, filtre de apa si reductoare de presiune, robineti termostatici clasici si digitali cu comunicare wireless, echilibrare hidraulica, sisteme cu radiatoar...
Honeywell Kombi-TRV noul robinet termostatic de radiator cu regulator automat de debit #WeAreResideo
zhlédnutí 6KPřed 6 lety
Honeywell Kombi-TRV - noul robinet termostatic de radiator cu regulator automat de debit combina functiile unui robinet termostatic si unui regulator de presiune diferentiala, care permite reglaj de temperatura concomitent cu echilibrarea hidraulica automata a instalatiei de radiatoare. Debitul de agent termic prin radiator este reglat automat in functie de temperaturile setata, respectiv masur...
4/4 Mentenanta Resideo Braukmann D15S - reductor de presiune cu scaun echilibrat, cu flanse
zhlédnutí 1,8KPřed 6 lety
4/4 Mentenanta Resideo Braukmann D15S - reductor de presiune PN16 cu scaun echilibrat, cu flanse, pentru sisteme de alimentare cu apa comerciale si industriale, regii de apa. Are scaun echilibrat: 1) inchide si la debit zero (cand robinetul consumatorului este inchis), evita egalizarea presiunilor amonte/aval cand nu exista debit; 2) presiunea reglata este mentinuta constanta, chiar si la varia...
3/4 Efectul Venturi Resideo Braukmann D15S - reductor de presiune cu scaun echilibrat, cu flanse
zhlédnutí 2,9KPřed 6 lety
3/4 Efectul Venturi Resideo Braukmann D15S - reductor de presiune PN16 cu scaun echilibrat, cu flanse, pentru sisteme de alimentare cu apa comerciale si industriale, regii de apa. Are scaun echilibrat: 1) inchide si la debit zero (cand robinetul consumatorului este inchis), evita egalizarea presiunilor amonte/aval cand nu exista debit 2) presiunea reglata este mentinuta constanta, chiar si la v...
2/4 Setare Honeywell D15S - reductor de presiune cu scaun echilibrat, cu flanse
zhlédnutí 751Před 6 lety
2/4 Setare Honeywell D15S - reductor de presiune PN16 cu scaun echilibrat, cu flanse, pentru sisteme de alimentare cu apa comerciale si industriale, regii de apa. Are scaun echilibrat: 1) inchide si la debit zero (cand robinetul consumatorului este inchis), evita egalizarea presiunilor amonte/aval cand nu exista debit; 2) presiunea reglata este mentinuta constanta, chiar si la variatii mari ale...
1/4 Functionare Honeywell D15S - reductor de presiune cu scaun echilibrat, cu flanse
zhlédnutí 17KPřed 6 lety
1/4 Functionare Honeywell D15S - reductor de presiune PN16 cu scaun echilibrat, cu flanse, pentru sisteme de alimentare cu apa comerciale si industriale, regii de apa. Are scaun echilibrat: 1) inchide si la debit zero (cand robinetul consumatorului este inchis), evita egalizarea presiunilor amonte/aval cand nu exista debit; 2) presiunea reglata este mentinuta constanta, chiar si la variatii mar...
Resideo Braukmann D06F - reductor de presiune cu scaun echilibrat, cu filtru fin incorporat
zhlédnutí 29KPřed 6 lety
Resideo Braukmann D06F - reductor de presiune cu scaun echilibrat, cu filtru fin incorporat
Resideo Braukmann F78TS - filtru autocuratitor cu spalare in contracurent, cu flanse
zhlédnutí 3,6KPřed 6 lety
Resideo Braukmann F78TS - filtru autocuratitor cu spalare in contracurent, cu flanse
Noul catalog Honeywell 2017-2018, prezentare de gama
zhlédnutí 3,9KPřed 6 lety
Noul catalog Honeywell 2017-2018, prezentare de gama
6 noi experimente de fizica cu magneti, presiune, temperatura
zhlédnutí 48KPřed 7 lety
6 noi experimente de fizica cu magneti, presiune, temperatura
Honeywell PrimusCenter DWC7000 modul compact alimentare apa rece
zhlédnutí 675Před 7 lety
Honeywell PrimusCenter DWC7000 modul compact alimentare apa rece
Resideo Braukmann F76S - filtru autocuratitor cu spalare in contracurent
zhlédnutí 3,6KPřed 7 lety
Resideo Braukmann F76S - filtru autocuratitor cu spalare in contracurent
Honeywell evohome - zonarea inteligenta a sistemelor de incalzire
zhlédnutí 3,6KPřed 7 lety
Honeywell evohome - zonarea inteligenta a sistemelor de incalzire
7 experimente de fizica cu magneti puternici, levitatie magnetica, electromagnetism
zhlédnutí 89KPřed 7 lety
7 experimente de fizica cu magneti puternici, levitatie magnetica, electromagnetism
Manual de branding personal de Dan Schawbel, prezentare de carte
zhlédnutí 831Před 8 lety
Manual de branding personal de Dan Schawbel, prezentare de carte
Alte 9 experimente fizica, presiune, temperatura, transfer de caldura
zhlédnutí 137KPřed 8 lety
Alte 9 experimente fizica, presiune, temperatura, transfer de caldura
FIZICA POVESTITA de Cristian Presura, prezentare de carte
zhlédnutí 3,6KPřed 8 lety
FIZICA POVESTITA de Cristian Presura, prezentare de carte
Sase sasi in sase saci de Carmen Ivanov - manual exercitii de dictie, prezentare de carte
zhlédnutí 7KPřed 8 lety
Sase sasi in sase saci de Carmen Ivanov - manual exercitii de dictie, prezentare de carte
Pinguinii din Madagascar trailer voice over
zhlédnutí 5KPřed 8 lety
Pinguinii din Madagascar trailer voice over
Documentar Vulpea vaneaza in zapada voice over
zhlédnutí 100KPřed 8 lety
Documentar Vulpea vaneaza in zapada voice over
Reclama Ford B-MAX voice over
zhlédnutí 2KPřed 8 lety
Reclama Ford B-MAX voice over

Komentáře

  • @nicolaevoinea4675
    @nicolaevoinea4675 Před 2 měsíci

    Ascultati ce spune omul chiar daca vinde honeywell, omul este printre putinii oameni pregatiti in adevaratul sens al cuvantului pe care am avut ocazia sa ii cunosc personal

  • @BusterDescoperaRomania
    @BusterDescoperaRomania Před 2 měsíci

    buna ziua , de unde pot sa cumpar un asa model la un pret mai redus? sau eventual o alternativa la acest termostat ( sa fie cu opentherm) . multumesc! :)

    • @cosminnita2820
      @cosminnita2820 Před 2 měsíci

      Bună ziua, căutați pe Google și veți găsi mai multe oferte pentru T6R. O altă variantă de termostat cu preț mai mic și posibilitate de funcționare duală (On/off TPI sau OpenTherm) - în funcție de cum este cablat receptorul - este T4R. T4R este wireless programabil (cronotermostat), dar nu poate fi controlat de pe smartphone.

  • @danielfilip2206
    @danielfilip2206 Před 2 měsíci

    Foarte interesant... bine ca m-am uitat la acest video, ca imi facusem deja un proiect, si acum trebuie sa-l modific... 😌

  • @petcuvg
    @petcuvg Před 4 měsíci

    Dacă la un termostat Honeywell dt 92 nu se mai aprinde ecranul, înseamnă că s-a defectat?

    • @cosminnita2820
      @cosminnita2820 Před 4 měsíci

      Nu neapărat. Dacă ați înlocuit bateriile și tot nu se aprinde, încercați să tensionați lamelele bateriilor astfel încât să apese mai tare pe baterii (e posibil să aibă contact imperfect). Dacă nu reușiți să remediați, comunicați-mi nr Dvs de mobil la cosmin_dn@yahoo.com și vă sun eu; remediem împreună pas cu pas la telefon.

  • @0723276066
    @0723276066 Před 4 měsíci

    Salut am un controler ecokom 200T si nu stiu cum sal setez v a rog sa ma ajutati un numar de tel daca se poate

    • @cosminnita2820
      @cosminnita2820 Před 4 měsíci

      Bună ziua, Vă recomand să contactați Dep Service Ferroli România: constantin.moroianu@ferroli.com, marius.ciciu@ferroli.com

  • @vladmihociu6738
    @vladmihociu6738 Před 4 měsíci

    Exista reductoare de presiune care sa mearga si in regim dinamic (difera presiunea de intrare) mai bune?

    • @cosminnita2820
      @cosminnita2820 Před 4 měsíci

      Buna ziua, modelul D06F Resideo Braukmann (fost Honeywell) este, dupa parerea mea (si nu numai a mea) unul din cele mai bune reductoare de presiune din Romania si chiar din Europa in prezent. Raport mare de reducere a presiunii (3,5:1), constructie cu scaun echilibrat (deci poate prelua presiunea fluctuanta), etc. Este important sa fie instalat si reglat corect - vedeti procedura de mai jos: Valoarea presiunii setate la iesirea din reductor (Piesire) trebuie sa fie cu cel putin 1 bar mai mica decat presiunea de intrare (Pintrare) in reductor; raportul maxim de reducere este Pintrare/Piesire = 3,5. Pentru rapoarte mai mari de reducere a presiunii se vor monta 2 reductoare in serie. Domeniul de reglare a presiunii (Piesire) este 1,5 - 6 bar. 1. Verificati daca reductorul este montat corect: sageata de pe corpul acestuia trebuie sa indice sensul de curgere a apei. 2. Inchideti robinetul de izolare de pe intrarea reductorului. 3. Verificati ca robinetul de izolare de pe iesirea reductorului este deschis; daca nu este, deschideti-l. 4. Deschideti robinetul de apa la utilizator (punctul de consum = chiuveta, dus etc) pentru a reduce presiunea in conducta dupa reductor (goliti conducta). 5. Inchideti robinetul de izolare de pe iesirea reductorului. 6. Folosind o surubelinita dreapta rotiti surubul din capul rozetei verzi in sens invers acelor de ceasornic pana cand rozeta se poate roti cu mana. NU desurubati surubul complet si nu il scoateti! 7. Detensionati arcul din reductor rotind cu mana rozeta verde pana la capat, in sens invers acelor de ceasornic. 8. Deschideti incet robinetul de izolare de pe intrarea reductorului. 9. Rotiti cu mana rozeta verde pana cand scala de reglare afiseaza valoarea dorita a presiunii in fereastra de pe rozeta. 10. Strangeti cu surubelnita surubul din capul rozetei verzi. 11. Deschideti incet robinetul de izolare de pe iesirea reductorului.

  • @dumitruflorin7682
    @dumitruflorin7682 Před 5 měsíci

    Salut! Mi-am facut instalatia singur din PPR folosind teava separata la tur cat si la retur, fiecare calorifer in parte este legat tur in partea de sus si retur in partea de jos, deci 2 tevi, la casa cu etaj de 90 metri patrati, cu centrala Saunier Duval de 24. Parterul la primele calorifere se incalzeste foarte tare cat si etajul, dar ultimele 2 calorifere care sunt cele mai mari respectiv de 180 se incalzesc doar in partea de sus si putin pana in jumatate, in partea de jos sunt reci. Am montate supare automate, am scos si aerul manual si tot degeaba, nu reusesc sa incalzesc ultimele camere. Cineva mi-a spus ca am teava prea groasa pe tot circuitul si nu face fata pompa sa impinga atata apa, m-a sfatuit de la jumatatea traseului sa pun mai mica ca sa micsorez volumul, am mai facut o investitie si am schimbat jumatate din traseu. Dar problema nu a disparut, a ramas aceeasi problema si ca sa incalzesc livingul de la etaj a trebuit sa opresc jumatate din parter, dar tot nu se incalzeste caloriferul pana jos. Ce as putea sa fac? Am aer pe retea, in calorifer? Sa opresc tur-ul la toate caloriferele si sa las doar retur ca sa impinga aerul in sus? Sau doar am centrala prea mica?

    • @cosminnita2820
      @cosminnita2820 Před 5 měsíci

      Buna ziua , trebuie să echilibrați hidraulic instalația din robineții de retur ai radiatoarelor: robineții de retur ai radiatoarelor celor mai depărtate de centrală să fie deschiși la MAXIM, iar pe măsură ce vă apropiați de centrală robineții de retur să fie închiși câte puțin (cea mai mică deschidere să o aibă radiatorul/radiatoarele care sunt lângă centrală). De asemenea, aerisiți bine fiecare radiator

  • @tonyyemm12
    @tonyyemm12 Před 5 měsíci

    Thank you! The best info help on CZcams. The Honeywell install book is very very poor, you made it easy .

  • @florentiunegut8419
    @florentiunegut8419 Před 5 měsíci

    Vă salut! Am următoare problemă cu un termostat t6r, anume la conectarea dispozitivului pe telefon îmi spune ca acest dispozitiv este deja conectat în alt cont. Mentionez ca nu am acces la dispozitivul vechi, cel pe care era conectat la aplicația Resideo și nici nu găsesc nicăieri opțiunea de a elimina device. Am încercat să resetez termostatul dar degeaba.. mulțumesc

    • @cosminnita2820
      @cosminnita2820 Před 5 měsíci

      0215891446 acesta e nr de call center Resideo / Honeywell Home , program L - V orele 10 - 19. Ei vor șterge dispozitivul de pe server, de asemenea vă pot ajuta cu inregistrarea in aplicația Resideo daca întâmpinați dificultăți.

  • @caraian91
    @caraian91 Před 6 měsíci

    Bună ziua, dețin un termostat T3R dacă trec la termostatul T6R la cutia receptorului mai trebuie sa fac ceva schimbări electrice? Sau rămâne așa si doar se resetează si împerechează cu noul termostat T6R

    • @cosminnita2820
      @cosminnita2820 Před 6 měsíci

      Bună ziua, Puteți folosi receptorul/releul T3R, îl resetați și îl împerecheati cu noul termostat T6R; tutorialul video al procedurii este în film la minutul 0:42:25. Poziția LED-urilor diferă puțin la cele 2 receptoare, dar principiul este același, procedura e foarte simplă. Dacă doriți, comunicați-mi la cosmin_dn@yahoo.com nr Dvs de mobil și vă trimit pe email și/sau whatsapp un fișier pdf cu informații utile, de asemenea putem vorbi la telefon dacă e nevoie (câștigăm timp, e mai simplu să vorbim în loc să scriem comentarii și mesaje lungi)

  • @prozonero
    @prozonero Před 6 měsíci

    Buna, am cumparat o centrala Centrala Termica Condensatie Buderus LogamaxPlus GB172i-24KD (7736901593) Apa Calda Menajera Instant (Combi fara Boiler), nu am gasit nicaieri pe net, daca acest model de centrala are OpenTherm, sau firele se instaleaza doar pe on/off?

    • @cosminnita2820
      @cosminnita2820 Před 6 měsíci

      Buna ziua, Din cate am vazut in manualul pe care l-am gasit pe internet, aceasta centrala nu pare sa aiba OpenTherm; va recomand sa verificati si Dvs in manualul pe care l-ati primit cu centrala, ar trebui sa aiba undeva simbolul (logoul)OpenTherm daca are acest protocol, de asemenea sa precizeze in text. Va recomand sa cablati receptorul termostatului din bornele sale A si B in placa centralei; este conexiune on/off cu contact liber de potential, dar cu algoritm inteligent TPI (Timp - Proportional - Integral), care asigura un consum de gaz cu circa 10% mai mic decat in cazul termostatelor clasice on/off (cu histerezis) si temperatura constanta in casa, fara fluctuatii, deci confort termic superior. Din experienta mea cu sute de clienti de-a lungul anilor, economia este de 10-15%. Avantajele TPI sunt foarte apropiate de OpenTherm, dar fara incompatibilitatile care apar uneori la unele centrale cand functioneaza pe OpenTherm. Inca ceva: orice centrala OpenTherm poate functiona si cu TPI. Detalii despre algoritmul TPI gasiti in acest film czcams.com/video/Il345bsmtyo/video.html . Daca doriti, comunicati-mi adresa Dvs de email la cosmin_dn@yahoo.com si va trimit un document pdf cu mai multe informatii pe aceasta tema

  • @stelic9515
    @stelic9515 Před 6 měsíci

    Bună ziua Am o centrală în condensație legată la o instalație in pardoseală+ calolifere supradimensionate(nu am grup de amestec deci temperatura spre calolifere este aceeași cu cea de la pardoseală) Deși am citit toate comentariile tot nu am o idee clară. Cum e mai bine cu temperatura tur 40grade(mai mult nu pot din cauza încălzirii în pardoseală) sau să încerc cu temp pe tur și mai mică de ex 35 sau 30. Cum este mai economic? Funcționare mai scurt timp cu temp mai mare sau funcționare timp mai lung cu apă mai rece Am și termostat smart Vă mulțumesc

    • @cosminnita2820
      @cosminnita2820 Před 6 měsíci

      Categoric e mai economic sa functionati cu temperatura tur 40 C. La 30 C radiatoarele au putere termica extrem de mica, centrala trebuie sa functioneze timp foarte indelungat, deci va consuma mult, de asemena veti avea disconfort termic. Acelasi lucru pentru 35 C. Conform graficului de randament functie de temperatura de retur (pe care il gasiti si in film), in cazul temperaturii de tur 40 C fata de 35 C pierdeti vreo 2% (adica infim) la randamentul centralei, dar puterea radiatoarelor creste cu aprox 30 - 40%, ceea ce e ENORM (studiati cu atentie acest link ca sa va convingeti budgetradiators.co.uk/radiator-output-measurement-and-delta-t-heating-conversion-factors ). Referitor la termostat: daca "smart" inseamna doar faptul ca se conecteaza la internet si puteti controla temperatura si de pe telefon…asta nu va aduce niciun avantaj la functionarea economica. Recomandarile mele pentru functionare economica si confort termic: 1) montati robineti si capete termostatice pe radiatoare (in caz ca nu aveti deja); daca termostatul e intr-o camera prevazuta cu radiator (deci nu intr-o camera cu pardoseala), setati capul termostatic al acelui radiator pe pozitia deschis maxim 2) setati temperatura agentului termic din centrala la 40 C; cand afara e frig (de exemplu sub 0 C), mariti temperatura agentului termic la 45 C; stati linistit, nu se intampla nimic rau cu pardoseala 3) achizitionati un termostat cu algoritm inteligent TPI (Timp - Proportional - Integral), care asigura un consum de gaz cu 10% mai mic decat al celor clasice (cu histerezis) - conform studiilor TACMA, BEAMA si Universitatii din Salford, de asemenea va da temperatura constanta, fara fluctuatii. Din experienta mea cu sute de clienti de-a lungul anilor, economia e de 10-15%. Exemple de termostate cu TPI: Honeywell Home DT92, T3R, T6R. Iata cateva link-uri utile: czcams.com/video/Il345bsmtyo/video.html, czcams.com/video/h62i-zGefZs/video.html , czcams.com/video/d9ujUBrW97Q/video.html

  • @valentinserban7284
    @valentinserban7284 Před 6 měsíci

    Am împerecheat acest tip de termostat cu o centrala Genus One Net și întâmpin următoarea problema : termostatul indica ca centrala a funcționat intr-o zi doar 30 min , dar aplicatia Ariston îmi spune ca CT a funcționat 6 ore . De ce apar aceste diferențe.

    • @cosminnita2820
      @cosminnita2820 Před 6 měsíci

      Bună ziua, Nu știu de unde provin aceste diferențe; sincer să fiu, nu am fost niciodată interesat de acest gen de informație. Ce vă pot spune este că termostatele Honeywell Home funcționează după algoritmul inteligent TPI (Timp - Proporțional - Integral): conform studiilor TACMA și Universității din Salford, termostatele cu TPI asigură un consum de gaz mai mic cu circa 10% față de cele clasice (cu histerezis) și temperatură constantă, fără fluctuații, deci confort termic. Din expriența mea de-a lungul anilor cu sute de clienți, vă pot spune că acest procent este de 10-15%. Dacă doriți, comunicați-mi nr Dvs de mobil la adresa cosmin_dn@yahoo.com și vă sun eu (câștigăm timp amândoi, in loc să scriem mesaje lungi), de asemenea vă pot trimite pe email și/sau whatsapp un fișier pdf cu informații utile despre TPI și modalități de eficientizare a funcționării sistemului Dvs de încălzire.

  • @dazzedify
    @dazzedify Před 6 měsíci

    Va multumesc! O revelatie sa gasesc lucrurile explicate corect si clar!! Discutia telefonica la ora tarzie m-a salvat de la inghet. Fara asistenta dumneavoastra nu m-as fi descurcat. Keep up the good work!!

  • @victorpetrurusu1660
    @victorpetrurusu1660 Před 6 měsíci

    Bună seara.Am un termostat T6R de care sunt mulțumit dar nu pot spune ca e un termostat care face economie la energie sau nu deoarece este primul termostat care il folosesc deoarece in primăvara lui 2023 mi-am montat centrală.Ce pot sa spun cami se pare ca pornește centrala cam des uneori face o pornire una după alta la nici două minute distanță!De de oare?Remarc faptul ca mai tot timpul caloriferele sunt călduțe si Intra-devar temperatura ambientală este foarte constantă.Socrul meu are un termostat obisnuit manual chiar si fără histerezis si centrala pornește mult mai rar si caloriferele între cicluri sunt complet reci .Ma intreb acum care din termostate face economie? Un service pentru aceste termostate unde este in București?Nu stiu daca este o problemă a termostatului dar am două probleme de semnalat: 1: cand centrala se oprește ledul de la receptor si flacăra de pe termostat uneori raman active si peste 30 de secunde până se opresc si ele. 2:am pus pe aceeași măsuță încă două termometre de cameră si intre termostat si celelalte termometre există o diferență uneori de până la 1.5 grade (temperatura mai mica la termostat ) Mulțumesc.

    • @cosminnita2820
      @cosminnita2820 Před 6 měsíci

      Buna ziua, Nu este nimic in neregula cu termostatul Dvs T6R: nici pornirile, nici diferenta de temperatura pe care o observati uneori etc. Pornirile relativ dese se datoreaza algoritmului inteligent TPI (Timp - Proportional - Integral). Conform datelor furnizate de asociația TACMA și Universitatea din Salford (Marea Britanie), termostatele cu algoritm TPI asigura: - economie de combustibil de circa 10% față de termostatele convenționale on/off cu histerezis -un nivel superior de confort termic, prin reducerea semnificativă (practic, eliminarea) a fluctuațiilor temperaturii ambiante - ceea ce ati observat si Dvs. Din experienta mea (am discutat pe acest subiect cu cateva sute de clienti utilizatori de termostate Honeywell Home de-a lungul timpului), economia fata de un termostat clasic este de 10 - 15%. Apropo de intrebarea Dvs: termostatul Dvs T6R cu algoritm TPI asigura o functionare mai eficienta decat cel al socrului Dvs, care este clasic (deci cu histerezis), deci consumul ar fi mai mic cu T6R; evident, daca ne raportam la aceeasi instalatie. Daca va deranjeaza acele porniri, puteti modifica parametrii algoritmului TPI din meniul AVANSAT al T6R la valorile Cycle rate = 3, Minimum ON time = 5, valori care sunt foarte bune pentru centrale pe gaz pe instalatii cu incalzire in pardoseala, dar si gaz cu radiatoare, peleti etc. Tutorialul video pentru schimbarea acestor parametri este in acest film la minutul 0:39:58; si cu acesti parametri se pastreaza avantajele algoritmului TPI. Referitor la diferenta de temperatura intre ce indica T6R si cele 2 termometre: www.honeywellhome.com/us/en/support/7-day-programmable-thermostats-1/ Recapitulez pe scurt conținutul link-ului în engleză de mai sus: corpul uman sesisează o valoare medie a temperaturii de radiație de la corpurile înconjurătoare (mobilă, pereți, ferestre etc), nu strict temperatura aerului din camera; termostatele Honeywell Home măsoară această temperatură resimțită de corp, nu cea a aerului din încăpere, spre deosebire de majoritatea termometrelor și termostatelor de pe piață,de aici rezultă uneori mici diferențe între valoarea temperaturii de pe termostatul Honeywell și cea de pe termometru. De asemenea, afișajul termostatului Honeywell Home rotunjește valoarea temperaturii afișate la 0,5C; de exemplu, la setpoint de 21 C, centrala va fi în stare oprită când în camera sunt 21,5 C și va fi în stare pornită la 20,5 (adică simte variația temperaturii în camera), dar afișajul va rămâne la 21 C (în exemplul din link-ul de mai sus sunt date valorile temperaturii în grd Fahrenheit, +/-1 grd Fahrenheit ca diferență/variație de temperatura înseamnă +/- 0,5 grd Celsius). Daca doriti ca termostatul T6R sa arate si sa ia in considerare o valoare a temperaturii identica sau mai apropiata de cele 2 termometre, puteti seta parametrul TEMPERATURE OFFSET(Compensarea/calibrarea) al T6R la +0,5 sau +1 (daca acum ziceti ca arata mai putin decat cele 2 termometre); pentru a modifica acest parametru trebuie sa intrati in meniul de parametri STANDARD ai termostatului (cu apasare SCURTA pe butonul de pe ecran, nu 5 secunde, ca la parametrii avansati). Va invit sa vizionati si filmul despre T6R, unde prezint meniul de parametri STANDARD czcams.com/video/d9ujUBrW97Q/video.html Daca doriti mai multe detalii despre algoritmul TPI si functionarea termostatelor Honeywell Home, comunicati-mi nr Dvs de mobil la adresa cosmin_dn@yahoo.com si va sun eu (castigam timp, in loc sa scriem mesaje si comentarii lungi cu explicatii), de asemenea va pot trimite pe email si/sau whatsapp un document pdf cu informatii suplimentare.

  • @alexvalentin3550
    @alexvalentin3550 Před 6 měsíci

    Are vreo importanta daca caloriferele sunt din fonta sau alt material la o centrala in condensatie?

    • @cosminnita2820
      @cosminnita2820 Před 6 měsíci

      Nu, nu are nicio importanță materialul radiatorului. Important este ca radiatorul să fie corect dimensionat.

  • @MesageriHarului
    @MesageriHarului Před 7 měsíci

    Sa trăiți am si eu o intrebare am centrală pe gaz instalată la parter si vreau sa instalez calorifere si la mansardă mai trebui ceva va mulțumesc

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, trebuie extinsă instalația existentă și la etaj, adică trebuie montate țevi și radiatoare. Contactați un instalator priceput, cel mai bine ar fi să faceți și proiect (cu un proiectant de specialitate). După montaj sistemul trebuie aerisit și echilibrat hidraulic (cu instalatorul).

  • @AdydeAdy21
    @AdydeAdy21 Před 7 měsíci

    Va salut,ce are in plus controlerul hcc100 fata de hcc80?

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Buna ziua, Informatii despre noul controller HCC100 gasiti in aceste link-uri: homecomfort.resideo.com/sites/Romania/ro-RO/Pages/warmfoot.aspx si homecomfort.resideo.com/resources/Shared%20Documents/ro-RO/Brochures/Brochures_10-23/WARMFOOT_B2B_BROCHURE_A4_RO_202309_V2.pdf Cateva deosebiri/avantaje fata de HCC80: 1. HCC100 se configureaza din smartphone prin aplicatia Resideo Pro: HCC100 comunica cu telefonul prin Bluetooth, tot prin Resideo Pro se integreaza si Evohome cu HCC100. HCC80 are butoane fizice. 2. HCC80 poate gestiona standard 5 zone de temperatura sau maxim 8 (daca se adauga extensia HCS80), iar termostatele (senzorii) din fiecare zona pot fi NUMAI wireless. HCC100 poate gestiona standtad maxim 8 zone care pot fi: toate 8 wireless SAU maxim 6 cu fir si 2 wireless SAU 4 cu fir si 4 wireless sau 3 cu fir si 5 wireless etc etc, deci orice combinatie de zone cu fir si wireless, in total 8 zone, dar maxim 8 wireless sau maxim 6 cu fir. La HCC100 toate termostatele cu fir trebuie sa fie OpenTherm (de exemplu: T3M, T4M, DT4M etc). Cele wireless sunt aceleasi ca la HCC80: DTS92, T87, DT4R etc) 3. Pe fiecare zona a lui HCC80 se pot cabla maxim 3 actuatoare. La HCC100, se pot cabla IN TOTAL 20 de actuatoare, care sunt liber configurabile: fiecare actuator se aloca din telefon zonei dorite, folosind aplicatia Resideo Pro si pot fi oricate actuatoare pe o zona. 4. Folosind HCC100, se pot comanda cu Evohome si zone care au termostate cu fir; Evohome cu HCC80 permite numai termostate wireless. 5. HCC100 are un sistem de borne rapide (cu arc), facand cablarea termostatelor cu fir si a actuatoarelor foarte simpla.

  • @hello_everyone...
    @hello_everyone... Před 7 měsíci

    Hello, what should be the PB (proportional bandwidth) setting for the maximum modulation feature of the boiler in the Honeywell DT92A model? What is your suggestion? system natural gas and combi boiler

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Hello, the Pb is 1.5 deg C as default. You can only make it bigger, but I recommend to keep it. Do NOT change it. Increasing it, you will only make the boiler cycle on/off very often. What you can do is change the TPI parameters to the values cr=3, Ot=5

  • @dragoscalin4883
    @dragoscalin4883 Před 7 měsíci

    Avem ce învăța de la D-tră, cu condiția să se și audă ceva. Se aude greu și cu un ecou deranjant. Ar fi excepțional dacă a-ți și explica fenomenele care intervin în experimente, sau probabil le și explicați, dar din cauză că se aude atât de rău, eu nu le aud. Oricum, nu oricine știe ce știți D-tră. Vă felicit. Succes și rezolvați sonorul pentru că e interesant ceea ce faceți.

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Am verificat sonorul din nou, acum, pe câteva dispozitive (telefoane, laptopuri, TV) și se aude bine, poate e nevoie să dați sonorul un pic mai tare, atât din CZcams, cât și din dispozitivul Dvs. Sunteti singurul (din zeci de mii de persoane care au vizionat experimentele) care afirmă că nu se aude bine. Iar explicațiile TUTUROR experimentelor sunt în descrierea filmului, în pagina CZcams; de asemenea, fiecare experiment are link cu minutul si secunda, tot in descriere. Și incă ceva: mai sunt încă 4 filme cu experimente pe canalul meu (cu explicații în descriere). Vizionare plăcută!

  • @ermatovanos8338
    @ermatovanos8338 Před 7 měsíci

    cat setam apa la o centrala in condensatie avand calorifere ff mari

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, Dacă spuneți că aveți radiatoare foarte mari, orientativ vă recomand să setați valoarea maximă a temperaturii agentului termic din panoul centralei astfel: când afară nu e foarte frig (temp exterioară mai mare de 5 C), puteți pune 50 C. Când e mai frig afară (sub 5 C), puteți seta 55 C. Pentru funcționare mai eficientă a centralei (consum de gaz mai mic cu circa 10%), vă recomand să cumpărați un termostat cu algoritm inteligent TPI (de exemplu Honeywell Home: DT92, T3R, T6R etc)

  • @AdydeAdy21
    @AdydeAdy21 Před 7 měsíci

    Va salut,aceasta automatizare honeywell ,va functiona tot pe modul TPI ? Ca si cum as avea doar un termostat...

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, controllerul inteligent Evohome este cel care comandă sursa (centrala termică) după algoritmul TPI, el integrează cererile de incălzire ale tuturor zonelor și le transformă intr-o cerere unică. Evohome are o gamă foarte larga de parametri TPI, de aceea este compatibil cu ORICE sursă de încălzire: centrală murala pe gaz, cazan pe combustibil lichid, cazan sau termoșemineu pe peleți, pompă de căldură etc. De asemenea, poate funcționa și in regim de răcire. Dacă doriți explicații mai detaliate, comunicați-mi nr Dvs de mobil la adresa cosmin_dn@yahoo.com și vă sun eu, de asemenea vă trimit informații suplimentare pe email și whatsapp

  • @hello_everyone...
    @hello_everyone... Před 7 měsíci

    Bună, care este setarea HC la termostatul de cameră honeywell DT92a?

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, presupun că vreți să aflați ce face parametrul Hc al termostatului DT92. Când acesta are valoarea 0, termostatul functionează in regim de încălzire. Când îi schimbați valoarea în 1, puteți comuta ulterior regimul de funcționare în răcire și invers. Acesta nu este un parametru al algoritmului TPI, în caz că asta vă interesa de fapt, ci Cr și Ot. Puteți să-mi dați adresa Dvs de email și/sau nr de mobil la cosmin_dn@yahoo.com și vă pot explica în detaliu, de asemenea vă pot trimite materiale cu informații utile.

  • @hello_everyone...
    @hello_everyone... Před 7 měsíci

    Bună ziua, știu că nu puteți modifica setările parametrilor termostatului modulator honeywell Y87RF2008.

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, Așa este, parametrii acestui termostat sunt ficși. Care este aplicația Dvs? Cu ce vă pot ajuta? Cum spuneam și în celălalt comentariu, dați-mi nr Dvs de mobil și/sau adresa de email la cosmin_dn@yahoo.com și putem vorbi detaliat.

  • @carmendobrescu-zangor4536
    @carmendobrescu-zangor4536 Před 7 měsíci

    Buna ziua Detin un termostat T4R. Am setat parametrii CR 6 cu OT 5 min. pentru plecari mai rare a centralei. Dar mi se pare rece in casa. Ce setare as putea face , ptr a pleca mai des.? De ex. 6 cicluri cu 3 minute ? Temperatura centrala agent termic. 55 grade.. Va multumesc anticipat.

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, ați spus corect: vi se pare. Pentru că termostatul menține constantă temperatura setată. Senzația de rece poate avea multe cauze: temperatură interioară setată la o valoare mică, suprafețe vitrate relativ mari, pereți exteriori neizolați, radiatoare subdimensionate și temperatură scăzută a agentului termic, radiatoare neaerisite, instalație dezechilibrată hidraulic etc. Vă recomand să setați din centrală temperatura maximă a agentului termic la 60 C. Iar parametrii termostatului îi puteți pune la Cr=3 sau 6, Ot=5. Dacă doriți, comunicați-mi nr Dvs de mobil la cosmin_dn@yahoo.com și vă sun pentru a discuta în detaliu despre instalația Dvs.

  • @dragosarsu3702
    @dragosarsu3702 Před 7 měsíci

    Intampin si eu o problema, am o centrala mai veche Hermann, este ok termostatul, insa am temperatura setata pe 23.5 grade, in casa 23.5 grade si centrala porneste din 20 in 20 de minute aproximativ, nescazand temperatura in perioada asta. Este vreo setare prin care sa scada gen 1 grad si ulterior sa porneasca? Ca si cand porneste, merge 30 de secunde si se opreste pt ca temperatura e cea indicata la fel cu cea setata. Un raspuns va rog din suflet. Multumesc

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, Tocmai asta e ideea: temperatura să nu scadă, asta face algoritmul inteligent TPI: consum de gaz cu 10% mai mic decât în cazul termostatelor clasice și tempetatură constantă, fără fluctuații, deci confort termic. Dați-mi nr Dvs de mobil și modelul de termostat (DT92, T3R, T6R etc) la adresa cosmin_dn@yahoo.com; vă sun și modificăm in 2 minute parametrii algoritmului, dacă doriți. De asemenea, o să vă trimit un document pdf cu informații utile.

  • @scarlatachemihai9142
    @scarlatachemihai9142 Před 7 měsíci

    Bună ziua! Am o pompă de căldură cu serpentină in pământ. Serpentina are o lungime de 400 m, iar țeavă este de 32. Pentru recirculare am o pompă IBO 25/120/180 - 160 l/min h=12 m. Pentru funcționarea normală a pompei de căldură trebuie un debit de 1,7 m³/h. La care din cele 12 moduri de funcționare setez pompa de recirculare pentru un debit de circa 1,7 M3/ h? Deferența de nivel în sol circa 4m

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, vă recomand să contactați un proiectant de sisteme cu pompe de căldură sol-apă; acesta va calcula înălțimea de pompare necesară pe baza pierderilor de sarcină hidraulică din bucla subterană (cel mai probabil aveți soluție de glicol, nu apă), de asemenea va verifica/calcula debitul necesar, rezultând astfel punctul de funcționare al pompei (sau domeniul de funcționare = o plajă de parametri). Apoi veți vedea pe ce curbă sau regim trebuie să setați pompa (apropo, eu nu am găsit caracteristica acestei pompe pe internet). În general, partea hidraulică a sistemelor cu pompe de căldură necesită proiectare/calcul specializat, nu doar estimări. Și aveți glicol, nu apă.

  • @alexandrescumihai3914
    @alexandrescumihai3914 Před 7 měsíci

    Bună ziua, am varianta round și aș vrea să știu dacă îi afectează perioada de învățare din moment ce eu îi setez setpoint ul pe timp de zi la 22 de grade și seara la 23 Și mai sunt momente când apare flacăra pe termostat și nu se declanșează centrala Mulțumesc frumos!

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, procesul de învățare nu este afectat dacă schimbați setpointul termostatului Round. Referitot la simbolul de flacără: el nu este un indicator că centrala este pornită sau că trebuie să pornească. Termostatul identifică o cerete de căldură (pe care o cuantifică procentual) și decide dacă e cazul sau nu să pornească centrala. Cu alte cuvinte, dacă simbolul de flacără este afișat, dar centrala nu pornește, înseamnă că temperatura este la setpoint sau foarte aproape, iar termostatul calculează pașii următori ai algoritmului TPI (când să pornească centrala și cât să o mențină pornită). Pentru informații mai detaliate, vă rog să-mi comunicați adresa Dvs de email la cosmin_dn@yahoo.com și vă trimit un pdf cu explicații detaliate (sau un nr de mobil și vă trimit pe whatsapp)

  • @AndreyJohnny
    @AndreyJohnny Před 7 měsíci

    Bună ziua! Recent am intrat în posesia unui termostat Honeywell DT 92A și as vrea sa știu dacă se poate dezactiva funcția TPI sau nu? Mulțumesc!

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, TPI nu se poate dezactiva, dar se pot modifica parametrii la valorile Cr=3, Ot=5 pentru porniri mai rare ale centralei. Cu aceste setări se păstrează avantajele pe care le conferă algoritmul TPI: consum de gaz cu 10-15% mai mic decât în cazul termostatelor clasice și temperatură constantă (fără fluctuații, deci confort termic superior). Găsiți procedura de schimbare a celor 2 parametri in film la 0:23:37. Dacă doriți, comunicați-mi adresa Dvs de email și/sau nr de mobil la cosmin_dn@yahoo.com și vă trimit pe email si/sau whatsapp un pdf detaliat despre TPI si termostatele Honeywell Home. Veți înțelege că nu are rost să vă mai gândiți la anularea TPI, iar schimbarea acelor parametri e suficientă (și avantajele se păstrează).

  • @valentinveghea5013
    @valentinveghea5013 Před 7 měsíci

    Este normal sa porneasca flacara la 3,4 minute,sa stea aprinsa putin si sa mearga pompa ....adica pornirile sunt foarte dese....este ok? Asa trebuie sa functioneze? Este prima iarna cu centrala ...un wiessmann boka 25 kw,si acest termostat.

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Bună ziua, da, e normal; este algoritmul inteligent TPI al termostatului, care asigură consum de gaz cu 10% mai mic decât al termostatelor clasice + temperatură constantă (fără fluctuațiile tipice pt termostatele clasice cu histerezis). Dacă doriți, puteți schimba parametrii termostatului la valorile Cr=3, Ot=5, iar avantajele TPI se păstrează. Găsiți procedura de schimbare in filmul meu despre Termostate Honeywell Home - algoritmul TPI. Dacă îmi comunicați la cosmin_dn@yahoo.com nr Dvs de telefon și/sau adresa de email, vă trimit pe whatsapp și/sau email un pdf cu informații detaliate despre TPI și funcționarea termostatelor Honeywell Home.

  • @AdydeAdy21
    @AdydeAdy21 Před 7 měsíci

    Buna seara,pentru o centrala pe gaz Ariston ,ce setări ar trebui sa fie la termostat....CR și OT? Mulțumesc

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Buna ziua, daca aveti incalzire in pardoseala va recomand Cr=3, Ot=5. Daca aveti radiatoare sunt ok setarile de fabrica Cr=6, Ot=1, care asigura temperatura constanta si consum mic de gaz. Sunt persoane care sunt deranjate de pornirile ceva mai dese ale centralei cu setarile Cr=6, Ot=1; in acest caz se pot folosi setarile Cr=3, Ot=5. Daca doriti, comunicati-mi adresa Dvs de email la cosmin_dn@yahoo.com si va trimit un document care va ofera multe informatii despre termostatele Honeywell Home, inclusiv despre parametrii Cr si Ot ai algoritmului TPI.

  • @hello_everyone...
    @hello_everyone... Před 7 měsíci

    Buna ziua, am o centrala in condensatie Buderus GB022i 20 kW, termostatul de camera honeywell dt92e cr ot tpi setari, cum ar trebui sa-l reglez pentru condens maxim, multumesc pentru informatiile date Nota: Are sistem de radiatoare tip fagure.

    • @cosminnita2820
      @cosminnita2820 Před 7 měsíci

      Buna ziua, pastrati setarile de fabrica Cr=6, Ot=1. Setati din centrala temperatura maxima a agentului termic la 60 C.

  • @marianneicu76
    @marianneicu76 Před 8 měsíci

    Buna seara, am o centrala Herman thesi condensing 32 kwsi am cumpărat de curand un t3r pe care inca nu l-am montat. Întrebarea mea este daca va fi compatibil cu centrala mea ? Si daca va trebui modificat cr si ot? Mulțumesc anticipat pentru răspuns

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      Bună seara, Da, T3R este compatibil cu centrala Dvs. Dacă sistemul Dvs este cu încălzire în pardoseală, vă recomand să schimbați parametrii termostatului la valorile Cr=3, Ot=5. Dacă sistemul este cu radiatoare, puteți păstra setările de fabrică Cr=6, Ot=1. Daca doriți, comunicați-mi adresa Dvs de email la cosmin_dn@yahoo.com și vă trimit mai multe informații.

  • @user-ix6wr2vh9v
    @user-ix6wr2vh9v Před 8 měsíci

    Salut , am si eu o intrebare . Stau la bloc 4 etaje si la parter pe colana sunt 2 radiatoare ce nu se incalzesc , deasemenea la etaj 1 unul din cele doua ce sunt pe aceeasi colana verticala nu se incalzeste . Celelalte pana la etajul 4 sunt ok. Nu stiu cum pot rezolva problema deoarece , toate tevile sunt schimbate , caloriferele sunt noi tevile pleaca din pivnita pana la etj 1 cu teava 28 cupru , cu 22 pana la eti 3 apoi 18 la etj 4 , colanele intre pricipala si calorifere cu teava de 15 . Aerisirea e facuta peste tot ., ce mai pot face sa incalzesc cele 3 clorifere? Tin aa anunt ca am facut o golire fortata pe retur si se incalzesc apoi dupa inchiderea robinetului iar se racesc .Va rog ajutati-ma cu un sfat. Multumesc anticipat

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      Salut, nu știu, e ciudat. Chemați o firmă de instalații care să vadă la fața locului configurația instalației și să decidă alte acțiuni.

  • @borceaadrian659
    @borceaadrian659 Před 8 měsíci

    Salut daca setez temperatura la 21 de grade el cat de mult scade ca sa porneasca centrala cand este in modu de invatare. Ms

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      Salut, algoritmul TPI (Timp - Proportional - Integral) al termostatelor Honeywell Home menține temperatura CONSTANTĂ, fără fluctuații; de asemenea, consumul de combustibil este cu circa 10% mai mic decât în cazul termostatelor clasice (cele cu histerezis). Termostatul învață si se adaptează permanent (ce invață în septembrie nu mai e valabil în ianuarie, când casa se încălzeste mai lent și se răceste mai repede). Mai multe informații despre TPI găsești în filmul meu despre termostate Honeywell Home de pe acest canal sau îți pot trimite un document cu explicații dacă imi trimiți o adresă de email la cosmin_dn@yahoo.com)

  • @user-bl8oq9lq3k
    @user-bl8oq9lq3k Před 8 měsíci

    Bună seara Detin o centrală Saunier Duval MicraCom Condens 24-AS, încălzire in pardoseală, aproximativ 120m2. Doresc un termostat Honeywell, a-și dori o recomandare din partea dv. Ce temperatura recomandati pe tur si ce setare pe termostat, am înțeles ca există o intarziere la centralele Saunier... Mulțumesc

    • @user-bl8oq9lq3k
      @user-bl8oq9lq3k Před 8 měsíci

      Am comandat un Honeywell t4r, va rog ajutați-mă cu setările pentru încălzire în pardoseală. Dacă se poate și o recomandare pentru temperatura apei pe tur pentru un consum și eficienta optimă. Mulțumesc anticipat

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      Setați parametrii termostatului Honeywell Home la valorile Cr=3, Ot=5; setarea este valabilă (in general) pentru încălzire în pardoseală, dar și pentru compensarea temporizării (întârzierii) la repornire a centralelor Vaillant, Saunier Duval și Protherm. Procedura e asemănătoare cu cea de la T3R (vedeți în film la 0:35:22), deosebirea e că butoanele sunt poziționate puțin diferit la T4R. Temperatura agentului termic o puteți seta între 35-40 C (40 C sau spre 40 C când e frig afară, mai mică atunci când afară sunt temperaturi moderate). Vorbiți și cu proiectantul și/sau instalatorul care a executat instalația și corelați temperatura agentului termic cu debitele pe care le-a setat pe circuite. În orice caz, temperatura nu trebuie să depășească 45 C deoarece există riscul deteriorării pardoselii.

  • @alinblidariu7580
    @alinblidariu7580 Před 8 měsíci

    Buna seara va scriu acum dar am vazut ca acest videoclip este vechi eu tot o sa incerc trebuie sa imi montez o centrala de 35kw am un boiler cu serpentina un puffer de 1500 l si cinci circuite cu caldura in podea sistemul de caldura are pompa inclusa acum intrebarea mea este mai trebuie montata o pompa in plus intre puffer si caldura in podea? Multumesc anticipat

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      Bună seara, Vă recomand să contactați un proiectant, care va indica soluția corectă pentru configurația instalației Dvs.

  • @carmendobrescu-zangor4536
    @carmendobrescu-zangor4536 Před 8 měsíci

    Buna ziua Am achizionat un T4R, si l am setat pe auto, un program de la 6 la 9 , 20.5, si de la 9 -15 19 grade. De ce temperatura ambietala se schimba imediat la programul 2. 19 grade pe cat este setat ? In camera temperatura nu este 19 grade. Va multumesc mult.

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      Bună ziua, Vă recomand să contactați call center-ul Resideo / Honeywell Home pentru a verifica dacă ați facut corect programarea temperatură / timp a termostatului: tel 0215891446 Program L - V orele 10 - 19

  • @mihaelalazar4354
    @mihaelalazar4354 Před 8 měsíci

    Va rog sa.mi spuneti si mie cum se numeste aplicatia care trebuie instalata ... Va multumesc!

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      În urmă cu câțiva ani aplicația se numea Lyric, apoi Honeywell Home; în prezent se numește Resideo, iar logo-ul ei este conturul alb al unei case pe fond roșu.

  • @phantomas1111
    @phantomas1111 Před 8 měsíci

    This is exactly what I needed. Thank you for the english subtitle.🙏

  • @carmendobrescu-zangor4536
    @carmendobrescu-zangor4536 Před 8 měsíci

    Buna ziua Am o rugaminte, sa mi dati un sfat, vreau sa mi cumpar un termostat honeywell, ce imi recomandati intre T3R, T4R, sau T6R. Care din ele este mai nou ? Mentionez ca am o centrala ariston clas one. Multumesc.

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      T6R este singurul dintre cele 3 care se poate controla și de la distanță de pe smartphone. Iar dintre T4R și T3R, T4R este mai nou. Toate 3 sunt termostate programabile (cronotermostate). T4R are un design mai modern decât T3R, de asemenea are funcția de răcire (nu vă e de folos în cazul unei centrale termice, care face numai încălzire); de asemenea, T4R are și funcționare cu protocol OpenTherm, care nu vă ajută cu nimic, întrucât centrala Ariston nu are OpenTherm; în fine, T4R și T6R pot fi programate cu până la 6 intervale de temperatură și timp pe zi, iar T3R cu maxim 4. Toate 3 funcționează cu algoritmul inteligent TPI (Timp - Proporțional - Integral).

  • @gaborbognar2056
    @gaborbognar2056 Před 8 měsíci

    Amazing video Cosmin, congratulations! Easy to understand how it works, moreover nice to see L1/L5 really works so straitforward.

  • @marcflavius7549
    @marcflavius7549 Před 8 měsíci

    Bună ziua. Am achiziționat un termostat T4R si nu înțeleg cum funcționează. Am văzut ca ați spus ca necesita timp pana "învață" cum sa funcționeze, dar am depășit o luna de când tot pornește centrala de zeci de ori pe zi, si in loc sa încălzească caloriferele doar le dezmorțește. In acest fel am un consum mare de gaz, si lipsă de confort termic. Daca măresc eu temperatura la termostat cu 1-2 grade, merge cateva minute si îmi arată ca a ajuns la acea temperatura dar este fals, deoarece alte termometre din casă arată o cu totul alta temperatura, adică cu 1-2 grade mai puțin. Ce as putea face deoarece ma gândesc serios sa schimb termostatul.

    • @cosminnita2820
      @cosminnita2820 Před 8 měsíci

      Bună ziua, Nu e nimic în neregulă cu termostatul Dvs. Dati-mi nr Dvs de telefon pe email la adresa cosmin_dn@yahoo.com. Vă sun eu ulterior și veți înțelege cum funcționează și avantajele acestuia.

  • @anaagainoaiei6197
    @anaagainoaiei6197 Před 9 měsíci

    Buna seara, din ce era geaca dumneavoastra din experimentu 5?, gen din ce materiale textile

    • @cosminnita2820
      @cosminnita2820 Před 9 měsíci

      Bună ziua, era geacă din fâș de la Decathlon

  • @sorinram78
    @sorinram78 Před 9 měsíci

    Buna ziua, Am un termostat T6R si o centrala electrica Bosch 15 kw. Ce setari ar trebui sa fac? Ea merge si cu CR 6 OT 1 si cu CR 3 OT 5. Dar pentru a eficientiza consumul. Temperatura e setata pe 22 grade celsius. Am panouri fotovoltaice 10 kw. Va multumesc anticipat!

    • @cosminnita2820
      @cosminnita2820 Před 9 měsíci

      Bună ziua, Pentru o centrală electrică vă recomand setările Cr=3, Ot=5. Pentru consum mic de energie electrică vă recomand să setați temperatura maximă a agentului termic din centrală la 65-70 C (deci nu la valori mici, ca la centrale pe gaz in condensație). Algoritmul inteligent TPI al termostatului T6R va avea grijă să mențină centrala pornită atât cât trebuie, iar valoarea maximă a temperaturii agentului termic se va atinge când afară e frig, de aceea e important să setați o temperatură mai mare (cum am precizat mai sus), la care radiatoarele au puterea termică mai mare, deci camerele se vor încălzi mai repede, iar centrala va avea un consum mai mic de energie electrică. Sper că am explicat clar.

  • @BodolayBotond
    @BodolayBotond Před 9 měsíci

    Salut. Azi mi-am luat un Honeywell T3R și am o întrebare: procesul de învățare al termostatului începe din momentul în care am introdus bateriile? Acum în timp ce îți scriu e 7 octombrie, geamurile sunt deschise și în casă sunt 23°C, deci nu e nevoie să dau drumul la centrală. Revin însă la întrebare, dacă procesul de învățare a început deja fără ca termostatul să pună în funcțiune centrala, ce va face la iarnă? Mulțumesc anticipat pentru ajutor.

    • @cosminnita2820
      @cosminnita2820 Před 9 měsíci

      Salut, Procesul de învățare începe când pornește centrala. Este un proces continuu de învățare și adaptare, iar rezultatele sunt remarcabile: algoritmul inteligent TPI (Timp - Proporțional - Integral) asigură un consum de gaz cu aprox 10% mai mic decât în cazul termostatelor clasice (cu histerezis) și temperatură constantă în cameră, fără fluctuații (deci confort termic superior). Termostatul vede timpii de încălzire și răcire (când încălzirea e oprită) ai casei și decide când să pornească centrala și cât timp să o mențină pornită. E un proces complex, bazat pe logică fuzzy. Încă ceva, apropo de învățare și adaptare permanentă: ce învață termostatul in noiembrie, de exemplu în cazul unei temperaturi exterioare de 7-8 C nu mai e valabil 100% în ianuarie, la o temperatură exterioară de - 5 C (de exemplu); timpul de încălzire a casei va fi mai mare în ianuarie, iar cel de răcire mai mic...iar termostatul se adaptează..cu rezultate excelente. Dacă vrei, îți pot trimite un document cu informații detaliate despre termostatele Honeywell Home, inclusiv algoritmul TPI: dă-mi un email la adresa cosmin_dn@yahoo.com și îți trimit, dacă vrei îmi poți da și nr de mobil: eu te sun și putem discuta detaliat.

  • @Ionut-SorinIancu
    @Ionut-SorinIancu Před 10 měsíci

    De ce nu mi se conectează Wifi la termostat?

    • @cosminnita2820
      @cosminnita2820 Před 10 měsíci

      Bună ziua, vă recomand să contactați Call Center Resideo / Honeywell Home 0215891446, program L- V orele 10-19 și specialiștii vă vor îndruma pas cu pas.

  • @catalindaniel3406
    @catalindaniel3406 Před 10 měsíci

    salutare. la o centrala pe peleti am 5 calorifere. pompa este 25-60-180. din calcule facute dupa acea schema imi reies H=1.96. pompa este pe treapta 1 are 3.5 mca. mai pot reduce debitul din robinetul de dupa pompa, cel care este la intrarea in centrala? am robineti termostatici si se aude zgomot cand se inchid. mulțumesc

    • @cosminnita2820
      @cosminnita2820 Před 10 měsíci

      Bună ziua, Vă recomand să instalați o vană diferențială de by-pass între turul și returul cazanului Honeywell Home DU145 www.aleroma.ro/ventil-de-reglare-a-presiunii-diferen-iale-r3-4-cu-olandezi-honeywell-du145-3-4a-70kw-3-bar-p2696 O setați la gradația 2 (înseamnă 0,2 bar) și se va deschide automat când presiunea diferențială între tur și retur depășește 0,2 bar. Aceasta este soluția tehnică corectă și cu un preț rezonabil. Dacă bugetul vă permite, montați vana DU145 și înlocuiți pompa cu una electronică cu turație variabilă. Dacă nu doriți să faceți nicio investiție, dacă aveți un radiator mic (de exemplu un portprosop într-o baie sau alt radiator mic), puteți seta robinetul termostatic al acestuia pe maxim permanent. Referitor la întrebarea Dvs cu inchiderea parțială a robinetului de lângă pompă: aveți mare grijă 1) robinetul să fie DUPĂ pompă în sensul de curgere al agentului termic (dacă e înainte de pompă riscați să o distrugeți datorită cavitației) 2) închideți-l foarte puțin pentru a nu afecta debitul prin cazan (risc de supraîncălzire și deteriorare a cazanului).

  • @mioaracireseanu6154
    @mioaracireseanu6154 Před 10 měsíci

    Buna ziua! Sunt foarte suparata si nemultumita de ambientul Honeywell Homme! Am instalat centrala noua de un an cu acest ambinet , si la interval de 6 luni el se opreste si nu mai merge!! Problema este ca trebuie resetat la 6 luni, eu nu ma pricep fiind singura , si trebuie sa apelez de fiecare data la un cunoscator! Acum nu se mai conecteaza receptorul cu termostatul .....a mers o perioada cateva luni dar acum becul verde de semnal nu se mai aprinde verde , este rosu , si la termostat clipoceste un TR

    • @cosminnita2820
      @cosminnita2820 Před 10 měsíci

      Bună ziua, Comunicarea wireless se pierde cel mai probabil datorită instalării necorespunzătoare: releul (receptorul) este prea aproape sau chiar lipit de centrală sau alt corp metalic. Comunicați-mi nr Dvs de mobil la adresa cosmin_dn@yahoo.com; vă sun și facem împreună câteva teste prin telefon și se rezolvă.

  • @raduradu2261
    @raduradu2261 Před 10 měsíci

    Va salut . Am o centrala bluehelix maxima 28c in condensare. La ce temperatura sa o reglez pentru caldura intre 55-60 sau sup 55 ? Multumesc.

    • @cosminnita2820
      @cosminnita2820 Před 10 měsíci

      Bună ziua, Presupun că aveți încălzire cu radiatoare și că sunt dimensionate pentru condensație. În zilele mai calde vă recomand să setați temperatura agentului termic din centrală la 55 C. În perioadele reci (temperatură exterioară sub 5 C) setați 60 C. Izolați termic imobilul cu polistiren de 10-15 cm (în caz că nu ați făcut-o deja) sau vată bazaltică etc. Montați termostat de cameră și setați o temperatură ambiantă rezonabilă: fiecare grd C cu care măriți temperatura ambiantă vă crește consumul cu circa 7%; când plecați de acasă câteva ore coborâți temperatura cu 2-3 C. Ca termostat vă recomand unul cu algoritm inteligent TPI, de exemplu Honeywell Home, care asigură un consum de gaz mai mic cu circa 10% față de termostatele clasice cu histerezis; câteva modele: DT92, T3R, T6R etc.