The Enphase 5P Home Solar Battery System
This is a deep dive into the Enphase IQ Battery 5P. This is a home battery for storing solar energy produced by your solar panels for later use in your home during grid outages or to save money on your electric bill.
If you are interested in a zero cost pressure free quote for turn key installation any of solar and storage products, fill out our intake form below...
Rocky Broad Solar Intake Form docs.google.com/forms/d/e/1FAIpQLSer5w_81iHtdcZBKV8Zuo9KVwJGQsqg_QNV-ePRvmWMiHZ8dg/viewform
If you are interested in Sol-Ark, EG4, Victron, or other DIY solar and storage products, check out some ROCK BOTTOM prices on those products using our affiliate links below...
Signature Solar affiliate link (CHEAPEST SOLAR PANELS ON THE MARKET and EG4 Products)
signaturesolar.com/?ref=uzUOpPif73O10D
Current Connected Affiliate (SOL-ARK PRODUCTS)
currentconnected.com/?ref=RockyBroadSolar
Practical Preppers (DISASTER PREPAREDNESS)
shareasale.com/r.cfm?b=1574707&u=4123057&m=99148&urllink=&afftrack=
Bluetti
shareasale.com/r.cfm?b=1745428&u=4123057&m=108816&urllink=&afftrack=
EcoFlow Store
shareasale.com/r.cfm?b=1537905&u=4123057&m=97298&urllink=&afftrack=
SunGold Power
shareasale.com/r.cfm?b=1729232&u=4123057&m=107752&urllink=&afftrack=
Jackery
shareasale.com/r.cfm?b=1539244&u=4123057&m=97366&urllink=&afftrack=
Also check us out at the following places....
Rocky Broad Solar Website
rockybroadsolar.com
Facebook
profile.php?id=61558585264414
zhlédnutí: 658

Video

Larson EasyHang Storm Door Installation with Board and Batten Siding
zhlédnutí 67Před 28 dny
This is a quick video of me adding some door trim, board and batten siding, a new coat of paint, and a new Larson EasyHang storm door to the back porch.
SolarEdge Home Hub Ecosystem - Solar and Home Batteries
zhlédnutí 589Před měsícem
This video covers a brief overview of all of the different components that make up the SolarEdge Home Hub Ecosystem. SolarEdge optimizers, a the SolarEdge Home Hub Inverter also known as the SolarEdge Energy Hub inverter, the SolarEdge Home Battery, also known as the SolarEdge Energy Bank Battery, the SolarEdge Smart EV Charger, and the SolarEdge Load Controller. This is a great all in one solu...
Growing and Harvesting Beets for Dinner!
zhlédnutí 103Před měsícem
This is a quick update on the ole vegetable garden this year as well as harvest time for my beets.
Should I Buy my Home Solar and Batteries from Some Guy on the Internet?
zhlédnutí 160Před 2 měsíci
The age old question...Should I buy my home solar and batteries from some guy on the internet? If you are interested in a zero cost pressure free quote to put solar and storage on your home, fill out our intake form below... Rocky Broad Solar Intake Form docs.google.com/forms/d/e/1FAIpQLSer5w_81iHtdcZBKV8Zuo9KVwJGQsqg_QNV-ePRvmWMiHZ8dg/viewform If you are interested in Sol-Ark, EG4, Victron, or...
I was wrong about Sol Ark 15K versus EG4 18KPV
zhlédnutí 7KPřed 2 měsíci
This video clears up some misinformation I released on a previous video comparing the EG4 18KPV and the Sol-Ark 15K solar inverters. ATTENTION I can not offer turn key installation services for Sol-Ark or EG4 products at this time. The products I can offer turn key installation services on are SolarEdge, Enphase, Tesla, and Franklin Whole Home. If you are interested in a zero cost pressure free...
The all new Tesla Backup Switch!!!
zhlédnutí 380Před 3 měsíci
This video covers the Tesla Backup Switch, a revolutionary new device that replaces the Tesla Backup Gateway. If you are interested in a zero cost pressure free quote for turn key installation any of solar and storage products, fill out our intake form below... Rocky Broad Solar Intake Form docs.google.com/forms/d/e/1FAIpQLSer5w_81iHtdcZBKV8Zuo9KVwJGQsqg_QNV-ePRvmWMiHZ8dg/viewform If you are in...
Tesla Powerwall 3 Home Battery Review
zhlédnutí 19KPřed 3 měsíci
This video goes deep into detail about the all new Tesla Powerwall 3 home battery, the Tesla Backup Gateway 3, and the Tesla Backup Switch. If you are interested in a zero cost pressure free quote for turn key installation any of solar and storage products, fill out our intake form below... Rocky Broad Solar Intake Form docs.google.com/forms/d/e/1FAIpQLSer5w_81iHtdcZBKV8Zuo9KVwJGQsqg_QNV-ePRvmW...
Franklin Whole Home Battery Review
zhlédnutí 2,7KPřed 5 měsíci
In this video we go in depth about the Franklin Whole Home APower X and the entire ecosystem of Franklin energy storage products. If you are interested in a zero cost pressure free quote for turn key installation any of solar and storage products, fill out our intake form below... Rocky Broad Solar Intake Form docs.google.com/forms/d/e/1FAIpQLSer5w_81iHtdcZBKV8Zuo9KVwJGQsqg_QNV-ePRvmWMiHZ8dg/vi...
Franklin Whole Home Battery versus Tesla Powerwall 2 - Who wins?
zhlédnutí 1,2KPřed 5 měsíci
This video gives an in depth comparison between 2 major AC coupled energy storage solutions for the residential solar and battery market, the Franklin Whole Home aPower X and the Tesla Powerwall 2. If you are interested in a zero cost pressure free quote for turn key installation any of solar and storage products, fill out our intake form below... Rocky Broad Solar Intake Form docs.google.com/f...
Solar Home Batteries - AC Coupled vs DC Coupled
zhlédnutí 3,3KPřed 5 měsíci
This video goes over the pros and cons of both an AC coupled energy system paired with solar panels, or a DC coupled energy storage system paired with solar panels. If you are interested in a zero cost pressure free quote for turn key installation any of solar and storage products, fill out our intake form below... Rocky Broad Solar Intake Form docs.google.com/forms/d/e/1FAIpQLSer5w_81iHtdcZBKV...
Solar Inverter Sizing - DC to AC Ratios
zhlédnutí 2,7KPřed 5 měsíci
This video addresses how to size a solar inverter AC output compared to a solar array DC output in several different scenarios. If you are interested in a zero cost pressure free quote for turn key installation any of solar and storage products, fill out our intake form below... Rocky Broad Solar Intake Form docs.google.com/forms/d/e/1FAIpQLSer5w_81iHtdcZBKV8Zuo9KVwJGQsqg_QNV-ePRvmWMiHZ8dg/view...
Sol-Ark 15K versus EG4 18KPV - Who Wins?
zhlédnutí 20KPřed 5 měsíci
CORRECTIONS Sol-Ark has 3 different datasheets for the same inverter, one stating 17,000 max PV input, one that shows a max 19,000 watt PV input, and another that states 19,500 watt max PV input. The datasheets were updated the inverter kept gaining additional PV input capacity, so the video is not a fair comparison in terms of max PV input. www.sol-ark.com/wp-content/uploads/2022/04/15K_Specs_...
The Solar 120% Rule: Understanding NEC Guidelines for Backfed Circuit Breakers
zhlédnutí 6KPřed 6 měsíci
The Solar 120% Rule: Understanding NEC Guidelines for Backfed Circuit Breakers
Fossil Fuel Generator VS Solar with Battery Backup!
zhlédnutí 259Před 6 měsíci
Fossil Fuel Generator VS Solar with Battery Backup!
Ring Security Camera Installation
zhlédnutí 114Před 6 měsíci
Ring Security Camera Installation
Ring Camera Hardwired - Fastest Install Ever!!!
zhlédnutí 605Před 6 měsíci
Ring Camera Hardwired - Fastest Install Ever!!!
Ring Spotlight Cam Plus Unboxing and Installation
zhlédnutí 848Před 6 měsíci
Ring Spotlight Cam Plus Unboxing and Installation
DIY Ring Security Camera Installation Hardwired
zhlédnutí 84Před 6 měsíci
DIY Ring Security Camera Installation Hardwired
Is Off Grid Solar Really Worth It?
zhlédnutí 328Před 7 měsíci
Is Off Grid Solar Really Worth It?
Easy DIY Chimney Cleaning
zhlédnutí 41Před 8 měsíci
Easy DIY Chimney Cleaning
Ladder Stabilizers for Safety
zhlédnutí 32Před 8 měsíci
Ladder Stabilizers for Safety
DIY Whole Home Surge Protector Installation
zhlédnutí 88Před 8 měsíci
DIY Whole Home Surge Protector Installation
Solar Interconnections and the NEC
zhlédnutí 248Před 8 měsíci
Solar Interconnections and the NEC

Komentáře

  • @JerHAMM
    @JerHAMM Před 7 hodinami

    If there’s one thing I can’t stand more than anything else 😂 With a white board behind you😂😂😂😂😂 Can’t make that shit up😂

  • @rianray7565
    @rianray7565 Před dnem

    Had my Powerwall 3 for a week now. Quite happy so far

  • @joelhiltz3329
    @joelhiltz3329 Před 2 dny

    This guy in pajamas forgot to clean up and us not an authority on the subject.

  • @silverstackingguru3806

    Great info thank you

  • @PeaceChanel
    @PeaceChanel Před 4 dny

    Thank You for All that you are doing for our Planet Earth.. .. Peace.. Shalom.. Salam.. Namaste 🙏🏻 😊 ✌ ☮ ❤

  • @user-ux1jp1ll7y
    @user-ux1jp1ll7y Před 7 dny

    In NJ for install 4 5p batteries companies want 38.5k $ this insane. 2 tesla powerwall 3 cost 22k $. Same chemistry, more capacity and more output. One thing is different tesla powerwall 3 can not be charged from generator.

  • @HerbertHerbGlum
    @HerbertHerbGlum Před 8 dny

    A great video, thanks for taking the time to put all of these new features and capabilities of the Powerwall 3 on a video. Perhaps the single biggest and in my view most important, features is that huge peak power capability. I live in the desert and have two AC units. For everyone else's inverters operating in backup mode, something has to be done to prevent the inverter from shutting down and going off line if both AC compressors start up at the same time, particularly if the OAT is over 100 degrees! I also have couple of quick comments / questions. On the mid circuit interrupters, in round numbers solar panels put out around 50 volts around midday, two in series output lethal voltage, so wouldn't the mid circuit interrupters need to be placed on each panel, not on every two or three? At least according to the Fire Dept. where I live there shouldn't be any lethal voltages when the system is in rapid shut down. You also said that you would have to buy enough Powerwall 3 units to power the whole home during backup. Doesn't it have any sort of load management / load shed capability? It seems that a good portion of the competing manufacturers either have automatic load management or are working on it. I would like to see another video on the Tesla App and in particular how it interacts with the Powerwall 3.

  • @ssmith2019
    @ssmith2019 Před 9 dny

    Great Vid ! Gracias Amigo !😁

  • @MatthewYBarbo
    @MatthewYBarbo Před 12 dny

    Really enjoyed a lot of the points you made in this video. Enphase is gaining more and more popularity depending on what the individual's needs are. With the ever changing solar industry, it's not always easy to keep up with new trends and equipment. Very educational piece. Keep it up!!

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 12 dny

      I appreciate the kind words @MatthewYBarbo, thanks so much for watching the channel!

  • @xxBLKSNXxx
    @xxBLKSNXxx Před 15 dny

    How am I getting a Gateway 3 installed with my PW3 ? I have an existing system with a SolarEdge inverter and optimizers. They tell me it can be AC coupled?

  • @jas340
    @jas340 Před 16 dny

    I have 4 Enphase 5ps installed. Calling it good for the next 20 years assuming I live that long.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 16 dny

      That lithium iron phosphate should keep you squared away. Thanks for watching the channel!

  • @AlexS0h
    @AlexS0h Před 16 dny

    I just looked at Tesla website, if you go to buy a power wall it does not say definitively what power wall version you are buying. Anyone know why?

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 16 dny

      No idea, but you can always get a quote directly from me. We generally are pretty competitive with the prices that Tesla charges on turn key installations.Thanks for watching!

  • @feedvid
    @feedvid Před 17 dny

    Great video. Thanks. 👍

  • @danmccoy6164
    @danmccoy6164 Před 17 dny

    Wow. Talk about major limitations. Not even compatible with there own older systems. Just a way to force you to buy more equipment exclusively from them.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 17 dny

      Yes, it is a shame. You can mix the 5P battery with older microinverters, but all micros have to be the same generation and all batteries have to be the same generation. No mixing of microinverters and no mixing of batteries. Thanks for watching!

  • @allenzorres7915
    @allenzorres7915 Před 18 dny

    Can we AC and DC couple at the same time? I think yes. What are issue will occure during the the setup? As DYI Trying to see what benefits for both system intergrated?

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 16 dny

      Absolutely. Depends on your inverter, but many battery capable inverters do allow you to both AC and DC couple separate PV systems at the same time. This would also give you another level of redundancy in case one of the two systems went down. Thanks for watching!

  • @seanburns1278
    @seanburns1278 Před 18 dny

    How about an install on a house that already has solar but no storage? Is there a way to install a PW3 so it charges off excess solar during the day and runs the house in the evening/night, without tying into the current solar system?

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 16 dny

      Absolutely. The Powerwall 3 recently was approved for "AC coupling" which is exactly what you are talking about. It basically tricks a grid tied only inverter into thinking the grid is operating and uses a CT clamp to monitor the PV output to charge the batteries accordingly.

  • @gunhawrtis
    @gunhawrtis Před 19 dny

    Very good video. Would be great if you can do more on microinverters such as install steps or components needed like dc/ac disconnect

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 16 dny

      Absolutely. I plan to do some more hands on videos in the future once the channel is up and running. Most microinverters have a combiner box with circuit breakers that are considered a code compliant AC disconnect per NEC guidelines, but many utilities have their own unique AC disconnect requirements.

  • @johnmiggins9431
    @johnmiggins9431 Před 23 dny

    wholesale sol-ark cost $5500

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      Good to know. I just based the price comparison on the standard pricing found online. Thanks for watching the channel!

  • @obijuan3004
    @obijuan3004 Před 24 dny

    Nothing new, Tesla is just catching up to the competition.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      I hear you. It is a constant race to be in front of the competition. Thanks for watching.

  • @Dreadlk
    @Dreadlk Před 25 dny

    I have been into Solar for Years and I am an EE. Some of these comments are just missing the point completely. This is about safety and what the inspectors want to see. It does not matter if your PV is limited to less than the Amps rating. It does not matter if your batteries are limited. Every Inspector knows that the Amount of Panels may increase and more batteries could be added later. They are only Interested in what is the Maximum the Inverter, Wiring and Panel box can handle when put together. This was a good video but could have been better if the Buzzer sound was eliminated.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      I hear you. The buzzer sound was my idea, but I hired someone else to edit it. The buzzer was much more annoying than I imagined. Next time I will try one of those movie "take 2" screens. Thanks for the comment and for watching the channel!

  • @MoleffSports
    @MoleffSports Před 26 dny

    I'm glad Sol-Ark has dropped the made in USA advertising. Also, I've seen too many vids of the Sol-Ark inverter being underpowered. I do like Will Prowse (sp) recent video of the EG4 12k showing the inverter able to start 4 compressors and a car lift without tripping the inverter. I'd love to see if the Sol-Ark 15k can do that. Also, pricing is a huge deal. Lastly, the ferrite filters they add to the panels as an EMP protectant I would have a hard time relying on. I would go with EMP Shield's products, it's much less expensive that paying to EMP hardening the Sol-Ark inverter and you can get all the proper protection for less cost, ie protection from the grid, the solar array and the battery.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      All great points. Sometime in the future I hope to be conducting more hands on videos with actual equipment, but it doesn't come cheap. Thanks for watching!

  • @joemontana4370
    @joemontana4370 Před 27 dny

    I’m pretty sure Tesla has had a meterbase mounted Backup Switch for 2-3 years already. Is this Backup Switch you’re describing different from that one?

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      Nope. I have been a certified Tesla installer for the past 10 years and the Backup Switch just hit the market this year. There are other meter collar adapters out there, but not a Tesla branded one. ConnectDER is a common one. Also some utilities offer them as a form of interconnecting to their grid. Thanks for watching!

  • @user-dc2ot2tj2b
    @user-dc2ot2tj2b Před 28 dny

    your talking solar not the inverter that is doing the dc to ac

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      That is correct. I am talking the ratio of the DC solar panel array compared to the AC size of the solar inverter. Thanks for watching!

  • @glennmcgurrin8397
    @glennmcgurrin8397 Před měsícem

    Do you have a source for the 20,400 watt peak for the 18kpv, I can't find a source for that and having an official source for that would make permits much easier for a project I'm working on.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      • 0 seconds ago Hi @Glennmcgurrin8397. I received this information via email response when reaching out to EG4 tech support before I created my initial video. I was also not able to find it on the datasheet, which was concerning. Every other inverter manufacturer that I am aware of lists the peak output power in 10 sec intervals on the datasheet other than EG4.

  • @glennmcgurrin8397
    @glennmcgurrin8397 Před měsícem

    Where do you get that 10 second power number for the 18kpv? I've been unsuccessfully looking for an official source for a peak output as part of dealing with some compliance issues if I want my ac on it as I'd need the peak output to be above the lcked rotor amps of my ac. If there's an official source for that 20,400 number it will save me a lot of work.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před 21 dnem

      Hi @Glennmcgurrin8397. I received this information via email response when reaching out to EG4 tech support before I created my initial video. I was also not able to find it on the datasheet, which was concerning. Every other inverter manufacturer that I am aware of lists the peak output power in 10 sec intervals on the datasheet other than EG4.

  • @cyumadbrosummit3534
    @cyumadbrosummit3534 Před měsícem

    Build Country of Origin for both...................CHINA

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      That is correct. That seems to be the way of the world these days. Thanks for watching!

  • @Realmccoy818
    @Realmccoy818 Před měsícem

    when the dc expansion packs come out, is it possible to add just that to enphase panel system ? or do we need the pw3 and the dc pack can only be added to an existing pw3 ?

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      The DC expansion units can only be paired with a PW3 battery. Thanks for watching!

  • @ushipb00
    @ushipb00 Před měsícem

    Informative Solaredge Ecosystem. Nice work!

  • @codyt.346
    @codyt.346 Před měsícem

    17:00 The Tesla backup switch, eliminates relocating loads to a Backup Load Center. If there’s not enough space in the main panel for the PW3 breaker a generation load center might be needed. 20:05 The PW3 can work with a Generac backup. Main panel, Gateway, Generac breaker in Gateway, then Generac relay, then Backup Load Center.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Absolutely. In that configuration the generator would not be capable of charing the battery though. It would be first line of defense(solar/batteries) and second line of defense(generator). In my opinion, if you have a fossil fuel powered generator, it is usually best to pair it with a system that can integrate the two power sources all into one system, but that is just a personal opinion. Thanks for watching!

  • @hasslefree3527
    @hasslefree3527 Před měsícem

    MAJOR PLUS for EG4 is that in can be installed right on top of the cable trough, because it does not have a requirement for any space at the bottom like the 6" for the Ark-Sol.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Good call out. I always thought the trough could have been made to look a little more sleek, but it sure does make things easy! Thanks for watching!

  • @niktak1114
    @niktak1114 Před měsícem

    Unfortunately this data is still incorrect. The max usable PV of the 15k is 18kW (with batteries). Without batteries it's only 15kW like your whiteboard shows. The maximum continuous inverter output without PV is also not a fixed 12kW. The maximum DC discharge rate is 275A and the output is based on that. So lets say the batteries are currently at 52V, after inverter losses it'll be able to output around 13.5kW. The 18kPV has a 250A max battery discharge rate so the maximum inverter output ends up being around 9-10% less than the 15k at a given battery voltage.

  • @TheFatman819
    @TheFatman819 Před měsícem

    The inverter is the heart of your system, Sol-Ark cost more best is has proven itself in the industrial market and is well made. I had nothing but nightmares with 3 Growatt 5000es and Signature Solar did not help. I used to wake up at night to make sure they didn't kick off and I had to restart them. Now with the Sol-Ark 15K running the while house including a 5 ton heat pump, I have had nothing but peace of mind. The customer support is top notch and they have moved their monitoring servers to the U.S.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      I hear you 100%. Having reliable tech support is worth it's weight in gold. Thanks for watching!

    • @houstonstarbuck
      @houstonstarbuck Před 22 dny

      Can you discuss how the gen and ac coupling work. When I called signature solar their tech support was both unable to answer the question and then when he tried he got it wrong.

  • @macbeliever
    @macbeliever Před měsícem

    I have a question about the 200 amp bypass for the grid connection for these inverters. With grid on, and the loads are exceeding the inverter output capacity, will the grid assist in powering the loads to prevent an inverter over current shutdown situation? TIA!

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Absolutely. With the grid connected, any consumption in the home that is not provided by the solar or batteries will draw from the grid, through that 200A bypass. Only when there is a utility outage or when the home is off-grid will it be limited by the PV/battery output power. Thanks for watching!

    • @Sol-Ark
      @Sol-Ark Před 11 dny

      @@RockyBroadSolarLLC In fact Sol-Ark is responsible for bringing this internal grid pass through feature to market (which eliminates the need for an AC combiner panel). Per their head of Americas, Luxpower is a Chinese R+D company (not a manufacturer). They sure did help themselves to our innovative design but even Tesla is following Sol-Ark into transformerless hybrid inverters. Regardless, Sol-Ark has the most field experience with transformerless hybrids in the USA market, including offgrid.

  • @gregcarnall9097
    @gregcarnall9097 Před měsícem

    Hi, great explanation, im about to buy a 6.9kw array on an East facing roof. I have been offered either a 5 or 7kw invertor for the same price. Which one would work better, i live in the UK so not especially a sunny climate. Im also having a 10kw battery if that impacts anything. Many thanks

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Tough call. That is a 1.38 DC:AC ratio. You could certainly get away with a 5K inverter, but you will probably experience some clipping in the late morning in the sunniest months of the year. Thanks for watching!

  • @Sol-Ark
    @Sol-Ark Před měsícem

    Great comparison. I would also pay attention to amperage. Sol-Ark MPPTs are full sized, not irregular amperage. This means greater design flexibility on the roof and not pushing to the limit for those larger PV arrays. You could call that max PV size conservatively specified as that line item isn't part of the UL certification. The Sol-Ark battery charger is also more powerful, which makes a big difference when wanting to use the inverter at maximum 12kW capacity throughout its life. Finally, there are a few features that might be considered a tie on the whiteboard. The winner of the tie should be the company that innovated the feature, not the one that copied it.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Thank you for the information and for watching the channel! I am flattered to have you commenting on my videos. I would love to do a deeper dive into more of your products in the future.

  • @thomasjacques5286
    @thomasjacques5286 Před měsícem

    Adding 2 PW3 to my existing Enphase PV system. Would not give up my individual panel monitoring. But the PW3 is a lot of bang for the buck. Installed after all credits and utility rebates OTD for $19K. My second PW3 is the Expansion unit. I'll have the best of both worlds.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      That is certainly possible now with the Powerwall 3 combined with the Backup Gateway 2 for AC coupling. Thanks for watching!

  • @robertplas3947
    @robertplas3947 Před měsícem

    Gotta tell you that this video is pretty much a waste of time. A bunch of numbers written on a white board. Then a price comparison. Absolutely of no value to a site that wants to set up a battery backed grid tied hybrid system. But you keep click fishing.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Well thanks anyways for the comment. It really helps the algorithm!

    • @robertplas3947
      @robertplas3947 Před měsícem

      @@RockyBroadSolarLLC Well, I gave your video a chance, watched it, determined it was a waste of time with no technical value and chose not to subscribe to your channel. That should be your real concern, you are making poorly crafted videos. Step it up man!

  • @davidtokhi8602
    @davidtokhi8602 Před měsícem

    I need some help figuring out my solar needs and what I build myself with an electrician. Thank you

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      That is not a service I currently offer other than my videos, but thanks so much for watching!

  • @lavectech
    @lavectech Před měsícem

    Looks like a great battery and it comes with a 6 string inverter! I was thinking of getting micro inverters for our apartment but if I can save money and still have just the battery and a gateway in the garage then I'm happy. Good to see they have rapid shut downs.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      It does save you some cash if you can sacrifice that module level monitoring. Thanks for watching!

  • @rodneynielsen1442
    @rodneynielsen1442 Před měsícem

    Not having Micro-Inverters, is a deal killer for me.

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      I also feel like losing the module level monitoring/performance manipulation is making a backwards move in technology. Thanks for watching!

  • @newtloken7884
    @newtloken7884 Před měsícem

    Nice overview and thanks for correcting previous info. That's a righteous thing otherwise, bad info piles up.. Hey, so one thing I'm always interested in is where the company is based and also where it's manufactured. I know, I can look it up but I think it's important in a side by side comparison. And besides employing my 'neighbors', it also may have warranty implications. I always prefer to buy American, except for an occasional Honda motorcycle... Thanks for your efforts! N

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      I am pretty sure that both inverters are manufactured in China, although both Sol-Ark and EG4 are U.S. based companies with R&D/tech support in the United States. Thanks for watching!

  • @Hypertrev11
    @Hypertrev11 Před měsícem

    Why would different strings need to face the same direction? PW3 has 6MPPT connectors. Wouldn't each string wired to different MPPT's not care which way the other one is faceing?

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Correct. As long as all panels on the same string are oriented the same way, you are good to go. You just want to avoid putting opposite oriented modules on the same string. Thanks for watching!

  • @icemaniiscott
    @icemaniiscott Před měsícem

    I was deciding last month between these same 2 inverters... I ended up going with EG4... a MAJOR factor was the friendly support from their tech support people, answering questions before the purchase and this continued after as well

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      Customer service and tech support is a big part of the decision. Thanks for watching!

  • @bill2292
    @bill2292 Před měsícem

    For the love of all that is good, please put down the pointer! It's really annoying.

  • @bill2292
    @bill2292 Před měsícem

    Good video, you know your stuff. Please put down the pointer when you talk bro!

  • @bearupfarm1818
    @bearupfarm1818 Před měsícem

    Sol Ark hay a better tech support. EG4 has a terrible tech support. I have experienced this.

  • @worthmor
    @worthmor Před měsícem

    True, hopefully they will be around for a long time. They seem to have lots of sales.

  • @aerojet393
    @aerojet393 Před měsícem

    Okay , these are the comparisons numbers for now , could change!

  • @dw7244
    @dw7244 Před měsícem

    How are you protecting electrical workers from backfeed during storm restoration effors?

    • @RockyBroadSolarLLC
      @RockyBroadSolarLLC Před měsícem

      That is the purpose of a microgrid interconnect device or a transfer switch. It severs the connection to the grid, so that when your secondary power source is sending out power to your home, that it does not send it out to the grid, your neighbors, or unsuspecting utility workers. Thanks for watching!

  • @adon8672
    @adon8672 Před 2 měsíci

    How much energy (in kilowatt hours) can the power wall 3 actually store?