Rising Tide Plumbing
Rising Tide Plumbing
  • 77
  • 1 475 643

Video

Uponor Pipe Freeze Test #plumbing #diy #plumber
zhlédnutí 1,1KPřed 4 měsíci
Uponor Pipe Freeze Test #plumbing #diy #plumber
Slab rough in with Uponor pipe. #uponor #plumbing #construction
zhlédnutí 1,6KPřed 5 měsíci
Slab rough in with Uponor pipe. #uponor #plumbing #construction
Washing machine drain line rough in explained. [Just over 2 minutes] North Carolina Code.
zhlédnutí 72KPřed 8 měsíci
Washing machine drain line rough in explained. [Just over 2 minutes] North Carolina Code.
Piping parallel to footings. How close can you get? Just over 2 minutes. #construction #plumbing
zhlédnutí 1,9KPřed 8 měsíci
Piping parallel to footings. How close can you get? Just over 2 minutes. #construction #plumbing
How to winterize your plumbing explained [4 minutes]. #diy
zhlédnutí 2,1KPřed 10 měsíci
How to winterize your plumbing explained [4 minutes]. #diy
Air admittance valves for plumbing venting explained, [just over 4 minutes]
zhlédnutí 105KPřed 10 měsíci
Air admittance valves for plumbing venting explained, [just over 4 minutes]
Do all plumbing levels read the same? I was surprised! #diy #plumbing
zhlédnutí 2,3KPřed 10 měsíci
Do all plumbing levels read the same? I was surprised! #diy #plumbing
Installing a water softener. Just over 4 minutes. [With pre filter and bypass]
zhlédnutí 4,4KPřed 10 měsíci
Installing a water softener. Just over 4 minutes. [With pre filter and bypass]
Plumbing a bathroom explained in 4 minutes. [You CAN do it!] #diy #plumbing
zhlédnutí 385KPřed 11 měsíci
Plumbing a bathroom explained in 4 minutes. [You CAN do it!] #diy #plumbing
Tankless water heater piping in under 4 minutes. Rinnai 199RSC with recirc #plumbing #plumber
zhlédnutí 7KPřed rokem
Tankless water heater piping in under 4 minutes. Rinnai 199RSC with recirc #plumbing #plumber
New house plumbing rough in. Great for remodel reference. Complete explanation.
zhlédnutí 25KPřed rokem
New house plumbing rough in. Great for remodel reference. Complete explanation.
The truth about plumbing a new house. This is how I do it.
zhlédnutí 1,2KPřed rokem
The truth about plumbing a new house. This is how I do it.
Plumbing Basics in 4 minutes. New house slab plumbing explained.
zhlédnutí 5KPřed rokem
Plumbing Basics in 4 minutes. New house slab plumbing explained.
Water and Sewer Tie in
zhlédnutí 1,6KPřed rokem
Water and Sewer Tie in
The Basics of Venting in Plumbing in 4 Minutes
zhlédnutí 329KPřed rokem
The Basics of Venting in Plumbing in 4 Minutes
Pex A Freeze Test. Frozen, will it burst under pressure?
zhlédnutí 11KPřed rokem
Pex A Freeze Test. Frozen, will it burst under pressure?

Komentáře

  • @jos2389
    @jos2389 Před 8 hodinami

    I'm in n.c and never see nothing like that I think is ilegal the bubble soap go out in the sink

  • @daddy1571
    @daddy1571 Před 8 hodinami

    Nice explanation! Horizontal wet venting is the norm for multi story apartments now. You explained it very concisely. You should do a vid about soldering copper properly next.

  • @FrancisMorris-o4g
    @FrancisMorris-o4g Před 13 hodinami

    Mosciski Mall

  • @HelenLangworthy-j2t
    @HelenLangworthy-j2t Před 15 hodinami

    Kling Haven

  • @giantgrowth4204
    @giantgrowth4204 Před dnem

    Go back to square 1 son

  • @giantgrowth4204
    @giantgrowth4204 Před 2 dny

    I only use Studor on the island. Or if while lvl header above washer

  • @CoffeyBonnie-m2f
    @CoffeyBonnie-m2f Před 2 dny

    Josh Islands

  • @DennisMoffett-g9y
    @DennisMoffett-g9y Před 2 dny

    Bins Causeway

  • @TeresaArendt-s7i
    @TeresaArendt-s7i Před 2 dny

    Ulices Road

  • @TrentZeger-y5w
    @TrentZeger-y5w Před 3 dny

    Hettie Crest

  • @TimothyThompson-e5y

    Konopelski Stravenue

  • @marlonfout5911
    @marlonfout5911 Před 3 dny

    Is your code 2" vent or can you run 1 1/2 vent

  • @stevekovacs4093
    @stevekovacs4093 Před 3 dny

    This looks like International plumbing code, and would not be allowed where UPC is enforced. Never heard of venting a toilet with 1 1/2 pipe, always 2 inch and this goes back 100 years. I am sure it will work, however it's interesting the contrast between the two regulations. Everything is UPC where I live. The IPC does make it simpler for installers and is more forgiving. There are code books that illustrate the two and compare interpretation.

  • @julianfox9286
    @julianfox9286 Před 3 dny

    Your lav is going to be double trapped like that.

  • @austinroberson8
    @austinroberson8 Před 4 dny

    Heck of an alignment hack at the end. I can tell you most plumbers eyeball it and that’s why there’s a lot of tension when you cut a joint. It’s because one end isn’t square with the other. Very smart hack!

  • @RusanganwaEvarist
    @RusanganwaEvarist Před 4 dny

    ❤❤❤❤

  • @jamesmiller301
    @jamesmiller301 Před 4 dny

    Thanks for your video. We are in a new build and will get the sewer smell from the sinks here and there. Almost seems like it’s from the over drain holes in the sinks. Please help.

  • @Ticonderoga12
    @Ticonderoga12 Před 4 dny

    Watever works!

  • @xzaclee4067
    @xzaclee4067 Před 5 dny

    Looks very nice.

  • @stormyyoung6344
    @stormyyoung6344 Před 6 dny

    Thanks for letting me learn something today.

  • @bellilly
    @bellilly Před 6 dny

    you're helping me understand plumbing logic and i thank you. i'm trying to figure out how it all works (to understand how my house's plumbing is put together), what's important, and your videos are very useful. : )

  • @user-zb2sx5cn6q
    @user-zb2sx5cn6q Před 7 dny

    best 4 min EVER......!!!!!!

  • @naftaliweiner1699
    @naftaliweiner1699 Před 7 dny

    What about the toilet isn’t that the 4th fixture unit?

  • @santime8190
    @santime8190 Před 7 dny

    Well first off it should be a “y” and not a “T” on the stack 😂inspection failed on quick glance

  • @stevea2488
    @stevea2488 Před 7 dny

    Nice !! That would work great, too, if the stem breaks

  • @tomjenkins1405
    @tomjenkins1405 Před 7 dny

    What is a stack. One vent through cealing. per stack.

  • @johnbeck6047
    @johnbeck6047 Před 7 dny

    I really appreciate your videos you prevented me from making a lot of mistakes

  • @JenniferKrell-j3n
    @JenniferKrell-j3n Před 7 dny

    Quick question. My toilet is in the center of the room. When I'm using a wet vent, can I use a double WYE fitting to branch off in both directions?

  • @johngallati8164
    @johngallati8164 Před 8 dny

    WHAT STATE?

  • @jeffreyplumber1975
    @jeffreyplumber1975 Před 8 dny

    yes its legal I understand its illegal to trap as well. UPC code

  • @ednorm6241
    @ednorm6241 Před 9 dny

    are you in sc by any chance i need sheet laminate counter tops installed

  • @offgridatliberypoint

    Great videos

  • @peterpiotrowski-h8f

    More guys like this, a life would be easier, Thanks a lot

  • @uncleharley1
    @uncleharley1 Před 10 dny

    If you're going to recommend we watch a specific video first, how about a link I looked for several minutes and still haven't found the video you recommend first

  • @matthewmcbeth4099
    @matthewmcbeth4099 Před 10 dny

    Amazing and quick information

  • @TheRealKalEll
    @TheRealKalEll Před 10 dny

    Our plumber was here to fix an issue and now it ALWAYS smells like... rotten eggs and sometimes poop. (System: Country septic holding tank/septic leach bed/tile bed.)

  • @marlonfout5911
    @marlonfout5911 Před 11 dny

    No clean out on the washer and laundry sink ? Should have a clean out on the washer & laundry sink

  • @elcachorrof1484
    @elcachorrof1484 Před 11 dny

    Thats is an ugly rough. Learn from the texas plumbers

  • @jordanstarcher3782
    @jordanstarcher3782 Před 11 dny

    Super informative. TY!

  • @HonorableBeniah-A
    @HonorableBeniah-A Před 11 dny

    I use a shoe spoon

  • @mrrich6412
    @mrrich6412 Před 12 dny

    Yes we can in NC USA

  • @DYIIdeas
    @DYIIdeas Před 12 dny

    Just replumbed an old farm house that didn't have any venting and used nothing but AAV's at all the fixtures. No more sewer gas. Works great.

  • @khildaehith11
    @khildaehith11 Před 12 dny

    Wtf are you dense? No way can we do this soap bubbler

  • @brittanythompson4366
    @brittanythompson4366 Před 13 dny

    Is the 2 inches for the wet vent a requirement by code? Or could you get away with using 1 1/2 inches?

  • @bryanjackson1571
    @bryanjackson1571 Před 14 dny

    Nope. That will be double trapped.

  • @richardordonez8331
    @richardordonez8331 Před 14 dny

    What i appreciate the most about this instal is that he didn't use any combination fittings with useless plugs in them

  • @RezaMemari-ux3xi
    @RezaMemari-ux3xi Před 14 dny

    Technically this consideration cud prevent big damage in future !!

  • @darincatanzarite6230
    @darincatanzarite6230 Před 14 dny

    No! That’s against code you must halve p trap on sink!

  • @theracerguy754
    @theracerguy754 Před 14 dny

    Just some pointers for you. I’m not planner and the only thing I’ve ever done is change a sink but the way you explain things to is too much as a college teacher. You leave too much room for questioning. Makes me way to find another video. If you are aware of this just know what’s gonna happen. People won’t follow you if you are doing this to gain followers then you might want to change your ways if you do it to get customers then keep going because you are making seem as if this is very difficult when in reality it’s not.

  • @hilhernandez998
    @hilhernandez998 Před 14 dny

    Can you do one on gray water from the shower and washer for those of us trying to grow shade in Phoenix, AZ while respecting water conservation ordinance?