Cutting takeoffs and proper attachment to trunklines (Mechanical Training # 104)

Sdílet
Vložit
  • čas přidán 27. 07. 2024
  • Test questions below!
    Common tools used are linked in the description below;
    Video Chapters
    0:00 Intro
    0:18 Tools used
    0:50 How to use a Malco hole cutter
    4:23 Assembly line process
    6:19 The do's and don'ts of takeoff placement
    9:48 Cutting takeoffs with snips
    15:25 Installation of takeoff on insulated duct
    18:11 Flex duct connection notes
    19:17 Working with flex duct and measuring tricks
    22:38 Flex connection to a boot
    27:12 Flex connection to trunkline
    29:02 AGL Mechaincal Tips Exclusive Tip
    29:58 Flex connection to trunkline
    33:45 More on Panduit straps
    35:28 Proper mastic application
    36:05 Closing
    Tools used;
    Wiss Scissors
    amzn.to/3HKBKP5
    Bostitch Staple Gun
    amzn.to/3V8xCLN
    Malco Hole Cutter
    amzn.to/3FzAUBP
    Red snips (Midwest offset were used in video)
    amzn.to/3V99mZI
    Duct tape used
    amzn.to/3PD7441
    Mastic tape used
    amzn.to/3HHVAdx
    Impact drill
    Speed drill
    Razor knife
    Sharpie
    Dykes
    Duct tape used
    amzn.to/3PD7441
    As an Amazon Associate I earn from qualifying purchases.
    Cutting takeoffs and proper attachment to trunklines (Mechanical Training # 104)
    1. When setting your hole cuter size you should;
    A. set it for the exact size hole you are cutting
    B. set it about a ¼” larger than the size you want to cut so that you have room for error when setting your takeoff
    C. adjust the speed setting on your hole cutter
    D. all of the above
    2. When using your hole cutter you should;
    A: cut in a clockwise rotation
    B. slightly angle your hole cutter so that it cuts faster
    C. pull back on the hole cutter towards the end of the cut so that the material doesn’t collapse.
    D. all of the above
    3. Whenever possible before starting takeoffs you should;
    A. route all of your supply runs to the trunkline
    B. mark your takeoff and then strap your run to the takeoff
    C. mastic the trunkline
    D. all of the above
    4. When cutting takeoffs you should;
    A. start and finish installing each takeoff individually
    B. if possible mark all takeoffs at once, then cut all takeoffs at once, then install all takeoffs at once
    C. carry all your tools with you while cutting takeoffs
    D. all of the above
    5. When installing takeoffs in a crawlspace the runs should be;
    A. perfectly level
    B. cut takeoffs towards the top of the trunkline and add an elbow to keep the runs high
    C. cut the takeoff at a slight angle and angle then run upwards to allow more room for crawling
    D. cut the takeoff towards the bottom of the trunkline to allow room to crawl over
    6. When marking takeoffs avoid placing takeoffs;
    A. closer than 12” of the endcap
    B. on a transition
    C. on an elbow
    D. all of the above
    7. When marking takoffs, takeoffs should be;
    A. at least 6” apart if not more
    B. staggered from each other and not directly across
    C. on the correct size duct outlined on the plans
    D. all of the above
    8. After setting a takeoff you should inspect and confirm that
    A. there is no material obstructing the opening
    B. that the radius of the takeoff aligns well with the duct
    C. there is a good seal around the takeoff, mastic tape if necessary
    D. all of the above
    9. When working with flex duct it is important to
    A. stretch the flex out after opening the box
    B. keep your ends tucked when working with flex
    C. immediately strap flex that it is hanging off a boot or fitting
    D. all of the above
    10. When planning runs out each run should have
    A. a strap every 8’
    B. downward slope for proper air flow
    C. at least 4-6 feet of flex with two 90 degree turns to avoid excessive noise and airflow
    D. all of the above
    11. Before hanging boots they should;
    A. always have flex attached
    B. have mastic applied if application allows
    C. have boot clips or plaster flanges if needed
    D. all of the above
    12. Flex runs should be routed and strapped to the trunkline prior to cutting takeoffs. When doing this it is important to consider;
    A. planning the most efficient route to the takeoff while considering attic access
    B. strapping every 4’ and avoiding any sagging
    C. strapping properly to avoid a kink at the boot
    D. all of the above
    13. When determining where to cut flex for trunkline attachment it is important to
    A. cut flex about 6”-8” longer to allow for connection loss, adjust if cut too long
    B. cut flex exact length to takeoff
    C. allow plenty of extra flex so that there is plenty for a connection even if the run ends up being too long
    D. cut flex short and add splice later
    14. When making a flex connection to the trunkline you should
    A. tuck the end of your flex duct so that the insulation is doubled up
    B. gently tighten the flex with a double piece of duct tape
    C. use double pieces of duct tape about 5” long, rounding them while sticking them in place
    D. all of the above
    15. When applying mastic to a takeoff you should
    A. only mastic tape seems
    B. solid mastic a clean circle around the takeoff
    C. mastic before you tape
    D. all of the above

Komentáře • 159

  • @markmartin6856
    @markmartin6856 Před 4 měsíci +10

    You can always tell when you're being taught by someone with tons of experience. Great job dude!

  • @Tony-dk1bp
    @Tony-dk1bp Před rokem +20

    I can't imagine a better teacher.

    • @yodamanrulz176
      @yodamanrulz176 Před rokem +2

      I have to applaud the teaching capacity, patience, and forthright giving the knowledge that this fellow is capable of. Your methodology should be taught to other teachers. So many are flawed. Thank you for your time sir. You’re one in 1 million. 👍🏻🤓

    • @courtneywilliams9530
      @courtneywilliams9530 Před rokem +2

      I teach for a living and he is a natural born teacher. His companies website says they have 100 years of experience, so I’m guessing he came from a family of excellent teachers. But I’m sending this to a number of my HVAC oversight on projects I’ve volunteered for because it is so helpful. Please keep putting out more. I will watch them all!!!

    • @Mr572u
      @Mr572u Před 11 měsíci

      ⁠@@courtneywilliams9530. Company’s

  • @jamespurchase4035
    @jamespurchase4035 Před 6 měsíci +26

    Jack Reacher does HVAC too? I'm impressed😂

  • @douglassmorris7375
    @douglassmorris7375 Před 6 měsíci +6

    I'm a DIYer and started a register reposition out of frustration. Was really uncomfortable until I watched this video. I am now so ready to finish this job😀.

  • @alexeilesukov6624
    @alexeilesukov6624 Před 6 měsíci +13

    My baby brother just recently got promoted to foreman at a hvac company and wants to bring me in. He told me to try to learn as much as possible about the trade by watching CZcams videos. He said that your videos are the most informative ones and that I should follow and subscribe. He also told me to lose some body weight. When you mentioned working in crawling spaces and uncomfortable positions, I understood. Thank you

  • @WOW_AQUATICS
    @WOW_AQUATICS Před rokem +17

    Best video on professional instruction installation I have ever seen. Thanks sir.

    • @tantricsphinx
      @tantricsphinx Před 7 měsíci

      When this piece ended, I thought, "Wow! That was the best..."
      🫡

  • @patrickjoseph7726
    @patrickjoseph7726 Před 6 měsíci +3

    Andrew, that was fantastic ! I'm a professional handyman and this is probably the best video I've ever seen for conciseness, camera quality, knowledge, and voice presentation . Great job ! PJ

  • @mikev.1034
    @mikev.1034 Před 12 dny +1

    I seen a bunch of videos like this but, I think your method is definitely superior to other methods I seen. 👍

  • @matthewray4637
    @matthewray4637 Před 11 měsíci +3

    From a fluid mechanics point of view, adjacent takeoffs (or takeoffs on opposite sides of the trunk in the same area) are more efficient than having two side by side on the same side of the trunk (particularly when they are close together). Adjacent ones will evenly distribute the airflow to both takeoffs and create two opposing vortices in the trunk which creates a negative pressure in front of takeoffs leading to a forward turbulent flow in the trunk line which has better sheer properties and can actually improve performance over longer runs. Having them on the same side one after another will create two vortices with the same direction on the same side, this can cause two big issues. First, if they are too close, you will have flow separation and potentially flow reversal immediately after the second takeoff. Second, if they are too close the vortex around the first takeoff can create a turbulent flow over the outlet to the second one creating a drop in pressure in the second line.

  • @freddycarballo4248
    @freddycarballo4248 Před 6 měsíci +2

    Man you are professional with no doubts.

  • @ianhinkle4587
    @ianhinkle4587 Před rokem +6

    2 years as an apprentice summed up in a 36 minute video. Great work. Keep them coming.

  • @pin_cushion
    @pin_cushion Před rokem +2

    Please keep making content! These videos put This Old House to shame. I just paid for a system design for my house with no preexisting duct and I'll be DIYing and this is the best advice for ducting i've stumbled across.

  • @philiplacey5430
    @philiplacey5430 Před rokem +1

    God help me if I ever need to crawl up in an attic and do any of this - but if I do, I'm ready! Nicely done!

  • @jdawes4403
    @jdawes4403 Před rokem +1

    Keep ‘‘em coming bro- you’re helping people !

  • @Esiddik
    @Esiddik Před rokem +2

    I watched like toooooo many videos of nonsense before I found you!!! and the only problem was because your title makes your videos hard to find !!!! 😭😭😭 ( for a beginner not knowing those are the terms to use)
    Amazing tutorial , you are an amazing teacher!! I wish I found you 16 videos ago 👏🏼👏🏼👏🏼👏🏼

  • @JayMurrr
    @JayMurrr Před 10 měsíci +1

    I watched many videos and got bored AF. But for some reason yours got my attention and I watched the whole video. I’m trying to add a run to my garage so I’m sure this is what I need to learn.

  • @marcveuhoff1871
    @marcveuhoff1871 Před rokem +1

    Excellent Video! We'll explained. I've seen many duct tutorials and you are one of the best.

  • @Davidandgoliathhvac
    @Davidandgoliathhvac Před rokem +1

    Great content Andrew! Keep showcasing your craftsmanship! It inspires guys like me to improve our skill set and quality of work.

  • @carlotodaro5052
    @carlotodaro5052 Před rokem +1

    awesome lesson, I can't wait to see the workmanship I have in my attic. I'm going to finish a room upstairs and wanted to see how everything needs to be. That was a great how to and explanation on how it all works. thank you, Sir.

  • @jerryc7016
    @jerryc7016 Před rokem +1

    Excellent video. Very detailed. Easy to understand. 👍

  • @colindgrant
    @colindgrant Před 9 měsíci +1

    Fantastic video. Very well explained with no fluff.

  • @absoluteidaho3767
    @absoluteidaho3767 Před 4 měsíci +1

    Excellent video and information! Thanks for sharing your knowledge!

  • @jeremygattenby2183
    @jeremygattenby2183 Před 11 měsíci +2

    Thank you! Going to be installing my own ducting to save some money. This video really helps.

  • @bradsmart7190
    @bradsmart7190 Před 6 měsíci +1

    Took on the job of installing my own furnace/heat duct. Lots to learn, thx for all the in depth info!

  • @JohnBehling-ek6ik
    @JohnBehling-ek6ik Před měsícem +1

    Outstanding video- you are an excellent teacher. Thank you for taking the time to share some of your knowledge.

  • @israelquintanilla2784
    @israelquintanilla2784 Před 3 měsíci +1

    Thank you for taking the time to teach us this very much appreciated

  • @briancarroll.
    @briancarroll. Před 4 měsíci +2

    Great video. Thanks for the lesson!

  • @3dux128
    @3dux128 Před 8 měsíci +1

    Pro! Pride in workmanship! Whatam I doing here. He had me hooked. Thanks.

  • @yorkrojas1452
    @yorkrojas1452 Před 9 měsíci +1

    Thank you Sir. Just started in the Trade!! Thanks a Million!!

  • @monkeyfinger7949
    @monkeyfinger7949 Před 3 měsíci +2

    Really great tutorial. I learned a lot. Thank you!

  • @janerikborge
    @janerikborge Před rokem +1

    Excellent presentation. Thank you.

  • @tomhernandez1308
    @tomhernandez1308 Před rokem +1

    I thought your cutting method for a takeoff hole was quite novel and effective. Given then chance, I'm gonna try that myself in my own DIY work. Thanks for the very helpful video.

  • @tantricsphinx
    @tantricsphinx Před 7 měsíci

    Andrew, I wasnt familiar with your channel before watching this video. Just wanted to say that I love your communication style. So deliberate, detailed, well reasoned...no fluff all useful knowledge. That was 36 minutes of learning. A very satisfying experience. Thank you!

  • @ryansport33
    @ryansport33 Před 3 měsíci +1

    I'm hooked. OG methods shown here!

  • @tunaman2200
    @tunaman2200 Před rokem +1

    Excellent Video! Thank you!

  • @elonmust7470
    @elonmust7470 Před 11 měsíci +1

    Thanks for putting your heart into what you do. I appreciate your sharing of knowledge!

  • @gabrielakerekes5844
    @gabrielakerekes5844 Před 11 měsíci +1

    Amazing video,very clear and at point teaching. Love your video and too bad you are not servicing Florida. We need to connect almost all returns from rooms to the main line. Builder did run the flex tubs but didn’t connect them to the Trunkline and that cause us a great trouble with AC uneven in rooms having 6-7 degrees difference from main hallway in the middle of the house where the main return it’s hook up and the rooms around the hallway. Now after leaving 10 years in the house we discover the returns are not hookup to the trunkline. I would love to give you the job but you are in different state. But honestly your video couldn’t be more clear and having mechanical knowledge and education,I think we my husband we can do it.
    Thank you for your video and I already subscribed . I enjoy watching you valuable classes! 🥂

  • @wdanderson1984
    @wdanderson1984 Před rokem +1

    Great information dude. Thanks for the video!

  • @edwardsmith9256
    @edwardsmith9256 Před rokem +1

    thank you for your excellent lesson on Flex duct work. I am currently replacing my old flex duct. I now see what I could have done better. Thank goodness, I have only just started. Hopefully, the fold back method will make things much easier. Thanks again for your video.

  • @gordonbramhan7520
    @gordonbramhan7520 Před 11 měsíci +1

    I have been in hvac for 30 years but installing ductwork is not my thing. Thanks for the information and detailed explanation
    I use zip ties and duct aluminum tape exclusively

  • @andranika6203
    @andranika6203 Před rokem +1

    Thank you for teaching 👍👍👍

  • @thomasbessent3670
    @thomasbessent3670 Před rokem +2

    sir I want to thank you for an outstanding presentation ! you have saved me thousands of dollars , you are very practical in your profession you have one good gift , and this one is needed in the HVAC community as a homeowner I will take out my 30-year-old duck board that has invaded my home . again thank you so much for your presentation ): God bless you and your family .

  • @user-qw2pt6os5y
    @user-qw2pt6os5y Před 10 měsíci +1

    excellent explanation

  • @jamescollins8148
    @jamescollins8148 Před 10 měsíci +1

    Phenomenal! Great video Thank You Andy!

  • @Lkom24
    @Lkom24 Před rokem +1

    I love the malco hole cutter

  • @terrygrant8126
    @terrygrant8126 Před 7 měsíci +1

    I have done it wrong and now I know thanks to you friend!

  • @scottschweigert1657
    @scottschweigert1657 Před 4 měsíci +1

    you gotta add a tip jar or something to your links --- this is such well done and high quality content

  • @WhiteWakedNProud
    @WhiteWakedNProud Před rokem

    TWIMC
    here in socal in commercial for flex tails, we use panduits with a strap gun and some people sink 3-4 screws into the zip tie. After using the strap tool, I've never had one snap or fall off with or without screws. As long as the strapping tool was used on a fitting with a rib, without a rib it'll forsure pull off but get it tight with the strap gun and fasten some screws through the zip ties, like 3 or 4 minimum even spaced out, then call it good. And the use of tape is unnecessary and air leakage will be minimal which imo makes the process easier, quicker, and prevents frustrations from working with tape.
    I'd also like to add that i think people snap the zip ties using the strapping tool and snap the zip ties which leads to frustration, causing them to hand tighten them or use linesman. Which is easily pulled off, however some screws into the zip ties can help without the strapping gun.
    However I believe this is due to mishandling of materials. If film tape, zip ties, or even the pookie get left in the sun it can degrade such materials significantly.
    Thank you showing how to insulate fittings, i spent hours google searching how to and such info was not available. Cant wait to wrap a 90 and it look tits

  • @jimmyfavereau
    @jimmyfavereau Před 11 měsíci +1

    Gold! Thank you 🙏🏼

  • @aKumah.
    @aKumah. Před 5 měsíci +1

    deserves a subscription 🤝🏼💪🏼

  • @clemgray
    @clemgray Před 8 měsíci +1

    Thanks… You just saved me $4000. Awesome

  • @Ageehvac
    @Ageehvac Před rokem +1

    Thanks bro...lots of info

  • @damianbenavides8653
    @damianbenavides8653 Před rokem +2

    Thanks 👍🏻👍🏻

  • @MickLeonardJD
    @MickLeonardJD Před měsícem

    Thanks Man.

  • @davejohnsonnola1536
    @davejohnsonnola1536 Před 6 měsíci +1

    F&B refrigeration guy looking to upgrade my 1940s cottage to central HVAC.
    Gracias.

  • @ansarhassan4
    @ansarhassan4 Před rokem +1

    Great video loved it, just wondering how to choose right duct size, I am planning DIY duct for my parents house. Please have video on this subject

  • @chris_jorge
    @chris_jorge Před 2 měsíci +1

    damn there's no chance ill find someone in miami, fl that will do a job with this level of detail

  • @performancehvacr6629
    @performancehvacr6629 Před rokem

    I have always done at least two wraps of duct tape and 3 screws. Do you find a need for screws? Awesome videos. I watched the first one a while back. Glad to see you back at it.

  • @jonc5152
    @jonc5152 Před rokem

    man - wish I'd found this sooner... I am on the tail end of redoing my upstairs (attic) ductwork. Not knowing how to handle rigid duct I opted to just do everything with flex. I basically made 2 straight headers down each side of the attic and tapped off to boots using wyes. I screwed the flex wire to the wyes with zip screws and sealed with mastic tape.... the inside air seals are durable but the jacket seals are not super great. I used canned foam to foam insulate the wyes but it makes the connection to the flex insulation odd. I think my way out to a decent quality is duct tape between the vapor barriers and foam. I am also considering zapping them with a coating of spray foam (2 part, not 1 part cans) as additional exterior sealant. If the duct taping goes well then I may just be able to mastic the whole joint instead.
    I leaned a lot on the attempt and I've also learned a lot from your great channel. If I redo my ducts in the future (if the ones I just did have an issue or maybe when I go to change out my new HVAC units in 12-15 years) then I will definitely go with rigid metal headers, hopefully I can just find pre-insulated spiral sections... I don't understand why those aren't more of a "thing".... pre insulated spiral with an array of pre insulated fittings... suspend, screw, foam seal together.
    Anyway... thanks Andrew!

  • @nlh8162
    @nlh8162 Před 9 měsíci

    Well that's a great teaching sermon right there my friend the problem is you have to find the suppliers that will stock these parts I love those start collars not all suppliers have them

  • @pastormartinez4676
    @pastormartinez4676 Před rokem

    Branching is the best best method, it self-balances air pressure and velocity.gradually reduce the size from the plenum with wyes and always use angled take-off’s (unless you’re working on a tight area such as a basement)
    Also,make sure to use dedicated Panduit gun (semi or automatic) and keep duct stretched and turns smooth!
    As a side note,we always use manual adjustable dampers, (where access is possible) it pays off when customers call-back complaining about un-even airflow (trust me,they always find a problem in one of the rooms)!
    And last but not least… if you’re running over 25 feet duct,upsize diameter 2” for friction,remember air is a fluid and follows the rule of “Path of least resistance”!
    I keep learning and improving my methods every day and following others good practices I’ve seen when I get a chance(on service calls) and applying what I’ve learned over the years… I must say without bragging that the results are extremely satisfying!
    This video it’s a good introduction for the apprentice on “How to” do the work,but in practice wouldn’t perform at it’s best!
    Good enough it’s neither good nor enough!
    Don’t get me wrong,this is a good video,but it would be a great video if it further explained the above mentioned facts!

    • @TonyNanni
      @TonyNanni Před 8 měsíci

      Why don’t you explain what your “branching” method is and show these “angled” takeoffs you would use on round pipe trunk line.

  • @MFD541
    @MFD541 Před 3 měsíci +1

    point is, no excuses for not knowing your job. well done.

  • @markdarling7526
    @markdarling7526 Před rokem +3

    Just watched all 36 minutes and loved it. You have taught me a lot about running and installing ductwork. Am about to tackle my house here in Florida. Original ductwork is 39 years old and I’m losing air and house stays dusty all the time. My house is only 1200 sq ft
    and replaced my unit from 1 1/2 ton to 2 1/2 ton just 10 months ago. The original ductwork is all flex , main truck line is 10” with 4” going to all the registers. Any tips or advice or other of your videos of yours you can tell me. Thanks again for taking the time to share your knowledge in this matter of HVAC ductwork.

    • @Perly53
      @Perly53 Před 8 měsíci

      Hi Mark. I'm in FL too with similar situation. Did you get this done? How did it go?

  • @ludwig6332
    @ludwig6332 Před 4 měsíci

    The guides state it is better to have opposite take offs at the same place for efficiency, as staggered close together reduces aire flow, static pressure.

  • @kelturner5452
    @kelturner5452 Před 11 měsíci +1

    When we do takeoff on insulated trunks we use the end of starter to cut thru by rotating back& fourth,like when you demonstrated dropping marker. Fantastic tutitor glad I' ve found your channel,subbed 1st. video before done. Great content no nonsense instructions! Keep them coming,love phrase quality is your reputation!! Permission to borrow sir? Thank you

    • @aglmechanicaltips
      @aglmechanicaltips  Před 11 měsíci

      You can use that phrase all you want. I'm glad you like the channel.

  • @TheFla904
    @TheFla904 Před 7 měsíci

    Pookie on the inner liner first, then panduit strap on the inner liner

    • @themrmoy40
      @themrmoy40 Před 3 měsíci

      why pookie the inside ?What's the point on that?

  • @learning2a2day98
    @learning2a2day98 Před 5 měsíci +1

    Electrician here, I can say I have never worked around any ductwork this guy has installed. The amount of times I have had to fix flex attachment points with only the large zip ties holding and zero tape. Weather, they are off when I get there or fall off from the easiest little touch. Having a conscious might make a little more work or take a little more time at the time, but what used to be called taking pride in one's work makes less work for all involved. Think down the line, after we all leave the jobs, service and maintenance involve human bodies with access being the most important part of those two inevitable facts of what we do in the trades.

    • @damienarnold6585
      @damienarnold6585 Před 2 měsíci

      Those guys must NOT be using a pan duet gun to tighten the zips. The zip will stay on a lot longer than the tape.
      I do hvac and when I run duct I use both zip and tape. Imo opinion to use one without the other is lazy. I've been back on jobs and seen the mess after a few years have passed .

  • @TheFla904
    @TheFla904 Před 7 měsíci

    If it’s snaplock pipe, use your duct knife and it pops a hole super easy

  • @joeshearer1247
    @joeshearer1247 Před rokem

    I like cutting the take offs before I wrap it If I can…. just curious what you thought about that. Also why You don’t use the skrim tape for the duct wrap

  • @lestalkmorebasss
    @lestalkmorebasss Před 12 dny

    On a commercial job site the insulators get upset if you go around cutting circles out of their insulation. They’d prefer you mark the circle and cut an X so the insulation is not removed. The cuts let the insulation be folded back and the tap installed 🤙 in a residential setting the X cut method creates less trash in the attic. I’ve seen some really awful ductwork during my years and mostly it’s from carelessness

  • @MichaelDFortner
    @MichaelDFortner Před 9 měsíci

    The heat in the attic will eventually harden the duct tape. I have some in my attic and it needs to be replaced. So I would use metal tape or something else.

  • @ericviele4379
    @ericviele4379 Před 5 měsíci +2

    Fantastic teaching and incredible work. My only concern was that you kept mentioning duct tape, but I’ve always heard duct tape is no good in this application (oddly enough).
    What type of tape do you use?

    • @rod00777
      @rod00777 Před 3 měsíci

      What type of tape is he using?

  • @joeshearer1247
    @joeshearer1247 Před rokem

    The only issue I see with double wrapping the tuck so much is you have a lot of excess inner liner bunched up

  • @cadamham
    @cadamham Před 28 dny

    How do you see taps with dampers and adjustable handle?

  • @sergiohernandez4163
    @sergiohernandez4163 Před rokem

    By code in Kentucky we have to use metal tape and zip tides instead of mastic. I argue my point that zip tides are worthless but can't argue with the inspector

  • @bethannejones-berger8507

    I have to take out a air return. It had some rust and I bought a new one, but I can’t get the original one off. There’s some kind of a weird tool that doesn’t work for a screw of any kind I recognize. How can I get it out?

  • @stevebabiak6997
    @stevebabiak6997 Před rokem

    No mention of dampers. Do you normally not use them?

  • @johndavidson5564
    @johndavidson5564 Před rokem +2

    Ok liked and subscribed first of all, second, I'm a commercial HVAC lead in Indiana and I have never seen anyone duct sealing the outside of insulation. Is that required in your area? we also never use the yellow formaldehyde insulation usually r-4 1/2 inch formaldehyde free, the white kind. Unfortunately, Panduit straps are commonplace here but I also tape the inner flex and then the outer after Panduits. Though after hearing your tear out experience with sweating I may stop panduit strapping the outer jacket. I am very curious to get your thoughts on some things as I am always trying to grow and learn. We typically wrap out pipes before installation, and then double back and duct seal all metal seems, then the next day we come through and piece out the missing insulation. We do not use staples as a matter of fact I have never seen staples be used here. Almost everyone uses Nashua FSK tape for holding the insulation together and some companies only use 3M Venture Tape UL181 which both does not adhere very well, and looks bad so I try not to ever use it. Also wanted to give you some video ideas since it seems that the channel is new. I would love to see you wrap a reducer and an end cap and some other fittings. thanks.

  • @willowmoon4866
    @willowmoon4866 Před rokem

    Can you teach us to connect a downdraft for an evaporative unit 3000 c.f.I . House 2:29 is 40 length x 35. It has three room left house plus 10x10 bathroom and right side living ding and kitchen.
    Do we use aluminum duct work or that flex stuff.
    Please teach us. Need your advise

  • @TonyNanni
    @TonyNanni Před 8 měsíci +1

    Didn’t know such tradesmen still existed. Must be the last one.

  • @scotthayes6946
    @scotthayes6946 Před rokem +1

    Hi Andrew. Great video. Great tips. Great techniques. One question: What is the duct tape you are using? Many thanks.

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem +1

      In this video I used Nashua 365 a.co/d/fAO8lsM This is a really sticky tape though so if it is really hot out 90°+, you might want to use shurtape (I dont have the model at this time).

    • @scotthayes6946
      @scotthayes6946 Před 11 měsíci

      @@aglmechanicaltips Wow.!! Thank you for the speedy reply. I will give the Nashua 365 a try. Many thanks.!!

  • @thecurious6721
    @thecurious6721 Před rokem +3

    Thanks for the great tips 👍 I am in Canada and we use rigid uninsulated ducts, which are (mostly) in conditioned space. But it is very informative especially as the flex ducts (as the manufacturers say) are gaining popularity here as well. Could you advise what kind of duct tape you are using and what will happen if you dont mastic over the tape at the take off? Do you use flexducts for 2 storey houses as well? We have difficulty moving air from the basement to the second floor with rigid ducts. I am wondering how it would be with the flexducts. Thanks 🙏

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem +2

      I was using Nashua 365 duct tape but I will changeout the tape used based on the season and outdoor temperature (super sticky duct tape is hard to work with on hot days). Mastic provides air sealing when applied directly to sheet metal seams. When applying mastic over duct tape on insulation seams it just provides another level of durability to the tape and prevents the tape from coming up. If you didn't mastic it, it would probably be alright but if it's available I would apply it.
      Couple notes on flex ducts; In my region, we don't have basements and normally wouldn't "chase" duct up to another level due to the length of run and a couple other factors. Long lengths like that should probably be ran in hard pipe but flex can be used if you do a static loss calculation on the flex and upside the flex to a larger size to account for the static loss. Example: a 6" hard duct that is 20' long might be equivalent to a 8" flex duct that is 20' long (I didn't calculate this, I'm just giving you an example). Hope this helps.

    • @thecurious6721
      @thecurious6721 Před rokem +1

      @@aglmechanicaltips Thank you very much for such detailed answer. 🙏

    • @hairlesscactus
      @hairlesscactus Před 11 měsíci

      Do you ever have condensation forming on the uninsulated ducts?

    • @thecurious6721
      @thecurious6721 Před 11 měsíci +1

      @@hairlesscactus in normal situation - no. In my experience I had issue only once, when the guy closed basement registers and it was very humid there and airflow was slow, so that ducts where very cold. Sometimes plenums sweat a little bit. Other than that no issues. And we have 70% humidity in the summer.

    • @hairlesscactus
      @hairlesscactus Před 11 měsíci

      @@thecurious6721 thank you for the reply!!

  • @darrenaugustine6508
    @darrenaugustine6508 Před rokem +1

    Thats awesome! What is your method of insulating boots?

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem +2

      We have been working on a video on insulating misc fittings which includes straight boots, 90 degree boots and endshot boots. We are hoping to get this video uploaded this week. Stay tuned!

  • @TB-px6jk
    @TB-px6jk Před 2 měsíci

    Do I need to paint the tape seams with duct seal on the supply and return ducts in a crawlspace if the crawlspace is encapsulated and has a dehumidifier installed?

    • @aglmechanicaltips
      @aglmechanicaltips  Před 2 měsíci

      Yes, unless the space the duct is in is the space you are conditioning I would seal it as much as possible. Any leakage into the crawlspace is lost efficiency. I use a product called "mastic tape" on my ductwork seams instead of duct tape then mastic (just saves time). I also seal the exterior seems but that is a code that exists in my region and might not apply to you.

  • @salzafar2030
    @salzafar2030 Před 10 měsíci +1

    Great video, is this some special duct tape for hvac ducts? Thanks

    • @aglmechanicaltips
      @aglmechanicaltips  Před 10 měsíci +1

      Yes, the tools and materials used are linked in the video description

  • @BradsHacks
    @BradsHacks Před 3 měsíci +3

    You look like Jack Reacher /Alan Ritchson

  • @domeniclarosa6156
    @domeniclarosa6156 Před rokem +1

    Hvac 101 jack reacher style

  • @pete7960
    @pete7960 Před rokem +1

    Your knowledge is amazing/impressive! I am working on a small 2 bedroom 1 bath home 880sq ft. The plan is to install a 2 ton unit with a square to round plenum that will include a 12" trunk 5-6' long. The trunk will have 6 takeoff saddles, (2) 8" for kitchen/dining and living room. (2) 7" for the 2 bedrooms and (2) 5" for the utility room and bathroom. From trunk to register boots there will be flex duct used 3' to 6' long max. I am wondering if this will provide sufficient air flow? The ducts will be in the unconditioned space with the intention of producing a compact system. Attic space is limited, the highest point is 24" Any advice will be greatly appreciated.

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem +1

      Without me going to paper with what you outlined I believe this will work fine. I would run a 14" return minimum to lower the system static pressure but 12" supply should be fine.

    • @pete7960
      @pete7960 Před rokem

      @@aglmechanicaltips Thanks Andrew! I watch your videos over and over, you have made it soo much easier for me to insulate. I hope you were in south florida, I would hire you, down here quality and workman ship is soo poor. Its all duct board and flex. I am looking for a quality install that I can only achieve by doing it myself.

    • @pete7960
      @pete7960 Před rokem

      @@aglmechanicaltips After writing my question. I have decided to make it mostly sheet metal, except for the area that the ducts cross the attic opening, there I will run short piece of flex, so if I ever need to go in the attic, I can remove the flex for easy access.

    • @pete7960
      @pete7960 Před rokem

      @@aglmechanicaltips I am installing a 9" jump duct from room to room and in the bedroom I am placing a 14x14 return grille on the wall where the air handler is on the other side. For the rest of the house, I will be using a louvered door.

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem

      Return will work great like that. Is there a reason you are using hard pipe for the branch lines? Sheet metal is technically better durability wise but if flex is strapped properly there is absolutely nothing wrong with it and your system will be much quieter at the vents as flex does much better acoustically. So hard pipe or flex but if it was my house I would flex those runs all day long especially with how short they are...

  • @janerikborge
    @janerikborge Před rokem

    Gteat video. What is the R value of the flex you used in the video?

  • @greggclark1805
    @greggclark1805 Před rokem

    How do I measure insulation for my duct work, it's about 6' round, I want to make sure the insulation fit?

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem

      I did a video on wrapping round pipe. See link on my channel but these are the pipe pattern sizes. Note that depending on the brand etc. these pattern sizes can be off a little bit. Always dry fit pattern sizes and adjust as needed;
      Pipe Pattern Sizes (ONLY APPLIES TO 3” INSULATION);
      (Note: Pattern sizes can change based on manufacturer and other factors)
      ALL SIZES ALREADY INCLUDE 2” LIP!
      4” = 16" + 2" Lip
      6” = 23" + 2" Lip
      8” = 30" + 2" Lip
      10” = 38" + 2" Lip
      12” = 44" + 2" Lip
      14” = 52” + 2" Lip
      16” = 57" + 2" Lip
      18” = 65" + 2" Lip

  • @scottschweigert1657
    @scottschweigert1657 Před 6 měsíci +1

    do you have to use a round take off on a round pipe? or can you bend the flange of a flat take off to fit? (none of the supply stores in my area have round takeoffs)

    • @aglmechanicaltips
      @aglmechanicaltips  Před 6 měsíci

      I've always been able to find round takeoffs, that's odd that your suppliers only have flat. I don't think flat would look good because it would bend the pipe it is attached to.

    • @scottschweigert1657
      @scottschweigert1657 Před 6 měsíci

      @@aglmechanicaltips one of the downsides of living in Hawaii - had to change my plan twice. Was going to do duct board, but can only find 1” duct board r4… so I found a place with round metal duct, but now no local place (even Home Depot) has round take offs! I can get em shipped but then they’re like $70 each … and I got 10 branches

  • @devinfisher1815
    @devinfisher1815 Před 16 dny +1

    Is that tape 1402 mastic or something a little thinner? And I assume it’s not necessary to mastic over the take-off to supply line? Thanks for the info.

    • @aglmechanicaltips
      @aglmechanicaltips  Před 15 dny

      It is 1402 mastic tape. If using "mastic tape" then it is not necessary to mastic over the takeoff but it should be sealed one way or the other if in non-conditioned space.

    • @devinfisher1815
      @devinfisher1815 Před 13 dny

      @@aglmechanicaltips Ty!

  • @xmanprime3328
    @xmanprime3328 Před 7 měsíci +1

    Safety glasses???

  • @BloominOnion1
    @BloominOnion1 Před rokem

    Hey man. At 30:00 let's say I have a damper in that collar with a threaded rod and wingnut sticking out. What 's the best way to get that flex over that without rips, etc?

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem +1

      I understand the struggle here. I bend the damper handle out 90° from the takeoff. Make a VERY small slit in the insulation jacket and press the handle through the insulation and insulation jacket. I then stab through a piece of duct tape with the handle to prevent the slit I made in the insulation jacket from spreading. I then bend the handle back down. So in the end you have a clean piece of duct tape flat against the insulation with the handle sticking though it. I hope I explained this right, kind of difficult... Also, depending on the flex brand you might not have to make the slit and can actually pierce it with the damper handle itself.

    • @BloominOnion1
      @BloominOnion1 Před rokem

      @@aglmechanicaltips you are the man. Thanks for the info. Top notch channel.

  • @trevmint5615
    @trevmint5615 Před 18 dny

    There's 2 different tapes in the tools list. The one you're using in the video has no plastic to peel away from the tape. Is the tape you're using good enough or do i need the other aluminum tape as well.

    • @aglmechanicaltips
      @aglmechanicaltips  Před 17 dny

      The tape that has the plastic peel away is "mastic tape" and is made for metal to metal connections only (sheet metal work). For fiberglass duct wrap or flex duct connections you will want to use the Nashua 365 tape (listed in description under "duct tape used").

    • @trevmint5615
      @trevmint5615 Před 17 dny

      @@aglmechanicaltips thank you.

  • @elijahgoodman3140
    @elijahgoodman3140 Před rokem

    Great video. No FSK tape?

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem

      No, we are required by code to coat our duct tape seams with mastic in my area. Duct tape works a bit better for contours in this application in my opinion. I do use FSK for small tears and rips simply because I can hide the tear altogether and it looks better than a blob of mastic in one small area.

    • @elijahgoodman3140
      @elijahgoodman3140 Před rokem

      @@aglmechanicaltips Gotcha, thanks for the response.

  • @jmelliottprop
    @jmelliottprop Před rokem

    What scissors are you using?

  • @1hiphopnow
    @1hiphopnow Před 8 měsíci

    Was that 4’ or 6’ flex?

  • @jeffc19831
    @jeffc19831 Před rokem

    What tape do you use?

    • @aglmechanicaltips
      @aglmechanicaltips  Před rokem

      Mastic tape used
      amzn.to/3HHVAdx
      Duct tape used
      amzn.to/3PD7441

    • @benfish527
      @benfish527 Před rokem

      @@aglmechanicaltips when do you use each tape? Is the mastic tape used on the connection between the flex inner core and the metal takeoff and also the flex inner core to metal boot?
      Is the non-mastic tape only for the insulation?
      Great series of videos btw. I've learned a lot!

    • @vikingrobot4179
      @vikingrobot4179 Před rokem

      Very informative video.
      I subscribed so as not to become a bitch/ripping duck tape at same time.
      Haha….that broke the class tension at the end.
      Curious if you have a video on installing the vent boxes.
      I’ll scour your videos to see…..loved the tutorial.
      Do you have a cheaper recommendation on the tape to use?
      $55.00 is a lot of money for a small job.

  • @dreece2000
    @dreece2000 Před rokem

    Big swol