Autocad Civil 3D - Harçlı İksa Duvarı (Duvar Boyutlarının Lineer Değiştiği)

Sdílet
Vložit
  • čas přidán 27. 08. 2024
  • Shoring Wall (Linearly Changing Wall Dimensions)
    Contact for assembly: civil3d.designer1@gmail.com
    OPERATIONAL STEPS
    A simple road with a 3:2 slope, 5 meters in width, will be drawn along a 100-meter route.
    An shoring wall will be constructed on the right side of the road, having the following specifications:
    - A fixed height of 2 meters between 0-40 meters.
    - A linear increase from 2 meters to 8 meters between 40-70 meters.
    - A fixed height of 8 meters between 70-100 meters.
    No drainage excavation will be carried out behind the wall between 0-40 meters.
    Drainage excavation will be conducted behind the wall between 40-100 meters.
    Once the project is drawn, calculations for the shoring wall will be performed, including:
    - Wall volume
    - Backfill material volume behind the wall
    - Wall excavation volume
    - Normal excavation/fill volume

Komentáře • 6

  • @sadkozdemir6727
    @sadkozdemir6727 Před 2 lety +1

    Maşallah üstadım çok güzel olmuş ellerinize sağlık başarılarınızın devamını dilerim

  • @huskodgn
    @huskodgn Před 2 lety +1

    Yapıyosun bu sporu şef👍

  • @emrahcitrak
    @emrahcitrak Před rokem

    Çok güzel çalışma. Merak ettiğim bir nokta var. Lineer geçişi SAC'da hangi komut ile gerçekleştiriyorsunuz? Bunun ile ilgili elinizde bir örnek dosya, döküman var mı?

    • @AutocadCivil3D
      @AutocadCivil3D  Před 9 měsíci

      Teşekkür ederim, mail adresim üzerinden iletişime geçebilirsiniz Emrah Bey.