- कॉलम में सरिया का लैपिंग कहाँ देना चाहिए
B-zone
1. 7 Big Mistakes in RCC Beam | 7 ऐसा ग़लती जो बीम बांधते समय होता है?
• 7 Big Mistakes in RCC ...
2. 8 Big Mistakes in RCC Column | 8 ऐसी गलती जो पिलर बांधते समय होती है?
• 8 Big Mistakes in RCC ...
3. Best Zone of Lapping in RCC Slab | स्लैब के सरिया का लैपिंग कहाँ देना है?
• Best Zone of Lapping i...
4. Best Zone of Lapping in Beam | बीम का सरिया का लैपिंग कहाँ देना है?
• Best Zone of Lapping i...
5. What is Joggle? Why we Bend a bar while Lapping? सरिया का लैपिंग में जोग्गल क्यों देते है?
• What is Joggle? Why we...
6. Reinforcement Lapping zone of Column for Residential Building | कॉलम में सरिया का लैपिंग कहाँ देना
• Reinforcement Lapping ...
7. Big Mistake of Column Top Surface at Construction Site
• Big Mistake of Column ...
8. Big Mistake in Formwork | Shuttering Failure at Construction Site |
• Big Mistake in Formwor...
#LappingZone #ColumnLapping #CivilEngineering
I have learn more knowledge here then spending 4 years in engineering college. This guy is really a precious asset for civil engineering community, and he always empower and inspire young engineers. May Almighty Allah give you long and successful life. From Pakistan 🇵🇰
thanks Khan Sahab
Laping me sariya sidha Dena hai ya band kerke
Mr deepak ji aap ki hr video best hoti h or aap kafi achha samghate ho thanks ........
Welcome
Thank you sir for sharing vital informations GBU
Bahut hi mahatvporn jankari......thanku.
Bahut hi badiya bataya sir
Thanku Guru ji
Thanks for sharing & explaining these kinds of imp. points..🙏
Nice sir ji
Very good idea.
Namaste Deepak sir..
Kindly batayein ki 1st floor mein jo columns ka sariya ek ya aadha foot nikla hua hai uska lapping centre mein kese ho?
Nice important
Thanks a lot sir
Thankyou sir
Good job sir
Good
Great information Sir, please tell us about COUPLER video.
osm
Thanks a million Bhaiya
thanks
Thank you very much sir ji for this valuable information. Sir ji first floor ki slab cast karne se pahele yadi column ke sariya ko overlap krenge to sariya ko uper kaise rokenge kyon ki height jyada hogi evam flat surface bhj nahin milegi. Please suggest. Thank you 🙏
Interview me pass kaise kare sir es per video banaye
Sir hook ke bare me video daliye
Column reinforcement is right direction.
Sir couplers par ak video banaye. And 3 question ka answer de plz.? 1- Kya coupling me bhi sariya alternate cutting hona chahiye ya colum k sabhi bars ak barabar kat k coupling kar sakte h.
2- coupling bhi B zone me hona chahiye ya A zone me kar sakte h.
3- coupling or laping me kon sa method jyada strong h.
Hello sir reply jaroor dena
Colam Leaping ke paas concrit kaise kare Lenter ke paas
Sir, if we start first floor construction what we have to do only the left two feet height bars?
Sir 2nd floor main colum kuch jagah 1ft se 1.5 fit hi chhat se Bahar Nikla hai usme kaise steel badhaye
Bhai Mera doubt hai lapping piller centre oke baaki bache piller ko bhi center tho kuch gadbad ho sakta hai kya. All piller centre lapping tho load badnese tootne ka dar hotha kya? Pl message or bathovo sir. Hyderabad se mahindra Goud.🙏🙏
Sir ji colum ka maximum duri kita ft hona chahiye ye batayiye jaise mujhe 21 × 17 ft ka Living room banana hai to colum kitna ft duri par hoga ...
Mera ek plan hai 27x31 size. Can you please check it?
Hello Deepak ji me ground floor se first floor tak apna Ghar bnaunga to kya me plinth beam 9"X9" se Kam Ka rakh skta hu agr ha... to Kitna Kam..plz suggest me..
Sir coupler is better than lapping can we use coupler for domestic construction
Bhaiya agr lap column k mid me dena hai to ye nhi smjh aya k 45D ka kya mtlb hua fr..jaisy apne btaya hai ki 10' ht. K hisab se 5' pe lap dena h to 5' bar to pehly hi ovr lap me ja raha h..jbki 45D k hisab se 720 mm yani 2'4" lap ban rah hai..to jra ye clr kr dijiye
Different b/w site engg. And design engg.
Coupling kaysa hoga
12×10 column 16mm×4 12mm×4 maximum column distance kitna le sakte hai for G+1
Sir length is between floor level & slab bottom or plinth beam level & slab bottom?
36× 50 isko abhi pura banana hai lekin baad men aisa banana ki baad men 2 part kar sake aur kitna column ayega please sir batana aur front men shop dena hai
👌👌👌👌❤🌷
20 ft me sariya kaat te h wo 2 ft or bad gya clint confuse ho raha h sariya jada kt raha h ab mai kya karu
Is coupler used in lapping zone?
Bade se bade balloon Banane se Kis Tarah Se Kaalam Jana chahie
Welding kar sakate hai sir???
Sir. ,, How much should be the center 2 center distance of steel in the slab .
6 inches CC
Sir jone a lapping aaya to kya hoga
Please video banao 😭😭😭
Mera lapping jone a me aa raha hai
Ghar already bana hua hai then lapping kaise hoga 5' par??
Deepak sir aap me mera house map nahi banaya
Splice length or development length??? 🤔
Sir any vacancy at your site?
Lapping dena jaruri hai kya .. sidha ek sariya upar tak nhi le ja sakte kya
सर गढ्डा की गहराई 4 फीट है और ग्राउंड लेवल से प्लिंथ बीम 4 फीट तक रखना है और 10 फीट पर छत देना है
कॉलम में 4 सरिया 16 एमएम की और 2 सरिया 12 एमएम को दे रहे तो आप बताए कि 16एमएम की सरिया को कितनी फीट तक कटिंग करे और 12 एमएम की सरिया को कितनी फीट तक कटिंग करे और 16 एमएम की सरिया में लेपिंग कहा दे 12 एमएम की सरिया में ले पिंग कहा दे
How to calculate CFT of column eg ( 9x 12" ) 10ft height
breadth 9"=0.75'
length 12"= 1'
height =10'
volume = 0.75 x 1 x 10= 7.5 cft
@@CivilEngineerDeepakKumar thank you 🙏
is it written in IS 456:2000 ? please confirm sir
IS 13920
Sir bina colom k kitna floor tak bna sakte h
2
भाई मेरे मकान का काम छत पड़ने तक पहुँच गया हैं अभी टाई बीम और छत पड़ना बाकी हैं अगर छत पढ़ जाती हैं तो 18 इंच सरिया (सरिया 16mm) ऊपर के लिये बचेगा !
तो अब मैं क्या करूं ?
(a) 18 इंच में ही लेपिँग करके ऊपर के कालम का सरिया लगवा दूँ ?
(b) टाई बीम तथा स्लेब के साथ मिलाकर और ऊपर के निकले हुये सरिया के साथ 30 इंच का लेपिँग कर ऊपर के कालम का सरिया लगवा दूँ ?
प्लीज़ जवाब जरूर देना कौन सा तरीका मजबूत रहेगा ?
a या b ?
Ground floor ki column mein lapping dena chahiye ya nahi. Agar jorurat he toh kyun?
Utna lamba steel khada kaise hoga
Thank you sir
Lapping kiya hota hai
Sir 1 4 slap ka apko koi video hai
?
Deepak sir look like,,,,
Vijay kumar😄😄😅
Slab m sabse jayda bending moment kha hota hai?????????
mid
Kya Plinth beam ke niche lapping Diya ja Sakta hai ?🙏
Kya aapko eska answers mila
@@firehouse7047 nahi
25 mm gone to zone A then what do we?
no issue
Sirji mai foundation bana kar chhod diya tha .ab ghar banana chahta hu.lekin foundation ke upar kewal 4 inch saria nikla hua.please mujhe kya karna chahiye.
galat hai
fir se banaye
Yadi framed structure bnana hai to galat hai
Magar yadi load bearing structure bnana hai aur foundation Ka width and depth theek thaak rakha hai to bnaa lo.
Saalon Saal bhi chal Sakti hai.
Lekin bhukamp aaney pe building load bearing ki tarah hi react karegee aur intensity jiyada honey pe collapse ho Sakti hai.
Choice aap ki hai.
Zone A me lapping dene se kya hoga
Aandhi tufan or earth quick me break hone ka chance hota hai
Lesser the bending movement, lesser the chance of failure during seismic jerks.
भविष्य में उपर घर बनाना हो और सरिया स्लैब से 1 फ़ीट ही उपर हो जो कि जंग लगा हुआ हो तो सर् उस परस्थिति में क्या करना चाहिए ? मेरे में ऐसे ही परिस्थिति बनी हुई है । लपपिंग कहा देनी चाहिए और कैसे ? कृप्या बताएं ।
drill kar ke de
@@CivilEngineerDeepakKumar drill se to purana lantel tutta hai. Us se koi problem nhi hogi?
@@sabsepahle1487
Send me picture in my email id
Sir apse kuch kam tha drawing se related kaise contact kare
Plz ans..
beam me lepping hoga
श्री मान लाल रंग के मार्कर का प्रयोग करे तो आप द्वारा लिखा दिखे
care this
Sir please thoda apna video short rakha kariye to the point baat krni chahiye 10 min kaa video bahut bda ho jata hai aur jo title hota hai video kaa wo last 2min mai hota hai to kosis kijiyega video thoda short rakhne ki
care it
Sir aap ke wajah se kitne engineer site pe gali khane se Bach jayenge thank u
thanks
Galat hai