Vacuum Circuit Breaker Nameplate Details | Explained

Sdílet
Vložit
  • čas přidán 28. 08. 2024

Komentáře • 35

  • @sisir22
    @sisir22 Před 7 měsíci +1

    very nice explanations sir

    • @GauravJ
      @GauravJ  Před 7 měsíci

      Thanks and welcome

  • @ratnesh12100
    @ratnesh12100 Před 4 lety +2

    Please make video on automatic fault locator AFL .. By the way nice videos..

  • @prabhakaranr3594
    @prabhakaranr3594 Před 4 lety +2

    Nice explanation

  • @surendrakverma555
    @surendrakverma555 Před 3 lety +1

    Excellent. Thanks

  • @akashpatil9341
    @akashpatil9341 Před 4 lety +1

    Nice video thanks you so much for knowledge sharing 🙏

  • @devendraparihar1253
    @devendraparihar1253 Před 4 lety +1

    Good explanation sir , thanks

  • @niluv3982
    @niluv3982 Před 3 měsíci +1

    nice

  • @VigneshVicky-hm7kc
    @VigneshVicky-hm7kc Před 4 lety

    Useful information! Kindly elaborate about DC component. I'm not clear about it,how it occurs & when? Pls guide us

  • @shemphangnongsiej2168
    @shemphangnongsiej2168 Před 3 lety

    nice video sir, thank you very much my doubt on the duty cycle is cleared. sir, can you please define or give some reference or share some light on how to arrive the ALTITUDE CORRECTION FACTOR of the BIL of equipment above 1000m level?

  • @Eng853
    @Eng853 Před 4 lety

    Hi sir, Please make a video of ferro resonance and their effects in instrument transformer

  • @EnthusiasticRedCar-xy4yg
    @EnthusiasticRedCar-xy4yg Před 5 měsíci

    Sir, want to know about why Nitrogen gas usage in PCVCB Bussings.tnxx🙏Jai hind🇮🇳

  • @electricalhacks1795
    @electricalhacks1795 Před 4 lety

    I request you please make a video on "power system stability enhancement by simultaneous AC-DC power transmission"

  • @Sanju-hr3cr
    @Sanju-hr3cr Před 4 lety

    Pls make videos on VCB DRAWINGS.
    CIRCUIT BREAKER CONTROL WIRING WORK.

  • @donberg01
    @donberg01 Před 4 lety

    What about load break switches? There are occasions when you have to open a circuit under load, please explain?

  • @jaherayo6978
    @jaherayo6978 Před 3 lety

    sir how we know the rated volted / current from normal volt/ current ,plz explain.
    Sir plz make a video on interlocking between isolator and vcb

  • @raj....8240
    @raj....8240 Před rokem

    Relay trip coil operation on
    Ac or dc
    Ya both reply sir🤩🤩🤩😍😍🛑🛑

  • @realislamicguidance2375

    CB having Higher DC component is better or CB having lower DC component is better?

  • @balachandra7475
    @balachandra7475 Před 4 lety

    Please make a video safe plus type rmu &vcb

  • @devendraparihar1253
    @devendraparihar1253 Před 4 lety

    Make video for LA , wave trap also

  • @rahulmudavath5923
    @rahulmudavath5923 Před rokem

    Sir, why CB rating is less than transformer full load current.

  • @magnamind
    @magnamind Před 2 lety

    Had some clarification on IEC62271-100

  • @sudheersubairkutty1633

    Please note that for breaker operating sequence is mentioned in IEC-62271-100, not in IEC-62271-1 which you mentioned.

    • @GauravJ
      @GauravJ  Před 3 lety

      Operating sequence is also part of IEC 62271-1

  • @dkverma67
    @dkverma67 Před 4 lety

    What's Ferro Resonance?
    Please explain

  • @narenderreddy7305
    @narenderreddy7305 Před 11 měsíci

    Ok

  • @chinnakarlapraveen9966

    Why in transmission substations 400kV is not directly stepped down to 33kV & why they do it in 3 steps as 400/132kV then 132/66kV and then 66/33kV?

  • @chinnakarlapraveen9966
    @chinnakarlapraveen9966 Před 4 lety +1

    Hi sir

  • @chinnakarlapraveen9966

    Sir make a video on why 50Hz is used in India, where as 60Hz in usa

  • @ratnesh12100
    @ratnesh12100 Před 4 lety

    At 6.47 min,
    Generally it is either 110vDC Or 220 vAC instead of 110 kv and 220kv

    • @GauravJ
      @GauravJ  Před 4 lety +1

      Oh sorry.. did i say kV.. it’s volt actually

  • @magnamind
    @magnamind Před 2 lety

    Hi

  • @RB-xv4si
    @RB-xv4si Před rokem

    I think you are confused. In a three phase system, two poles is single phase, not two phase.