  • @jamaanalshahrani756
    @jamaanalshahrani756 Před 3 lety

    👍🏻 great explanations

  • @user-rj6ck6go5e
    @user-rj6ck6go5e Před 4 lety

    great work mr tahir

  • @samehmedhat7955
    @samehmedhat7955 Před 3 lety +1

    Could you please advise how can I enter a specific tap-changer value in PU for 2-winding transformer supposing I have a 230/69kV transformer with +/- 6.25% Tap Changer set as 0.3125 PU .. How can I enter this value to PSSE to deal with during power flow analysis?

  • @khairulfahim
    @khairulfahim Před rokem

    From where you got the excel file data

  • @ArjunSingh-rc2hb
    @ArjunSingh-rc2hb Před 2 lety

    Dear Tahir, I am working on version psse 34. but you have worked on psse 33. so any major difference between them. because i created ieee 9 bus system. psse34 is not working as psse 33. please suggest me. what can i do for this problem.

  • @thannainglin2462
    @thannainglin2462 Před 3 lety +2

    How to consider and calcualte Mvar of load and asumption of Generator MvarQ??

    • @Power_System_Experts
      @Power_System_Experts Před 3 lety

      Reactive Capability Curve for Generator and for load it is specified mostly

  • @pradeepkatariya3303
    @pradeepkatariya3303 Před 4 lety

    After changing set point , there is mismatch in infinite bus power . so can we consider it or we need to adjust load flow again ??

    • @Power_System_Experts
      @Power_System_Experts Před 4 lety +1

      If the output bar message is Met Convergence Tolerance then no need to adjust load flow analysis. But make sure that all generators are supplying reactive power within its capability curve range.

  • @sushmapallapothu9663
    @sushmapallapothu9663 Před rokem +1

    Hi,Thanks for the video, do you know how I can search for a specific bus number on the SLD?

    • @Power_System_Experts
      @Power_System_Experts Před rokem

      Go to ---> Power Flow and then G-out (Generate Bus Display). Then enter bus number

    • @Power_System_Experts
      @Power_System_Experts Před rokem

      Another way is via Auto Draw option. Which is under the tools bar tab.

  • @umarframadhan3190
    @umarframadhan3190 Před 3 lety

    Hello Mr Tahir,
    About Excel data, is the data from privately resouces or standard in IEEE?

  • @narayanaswamy5665
    @narayanaswamy5665 Před 3 lety

    Nice Video, Thanks for sharing. I have a doubt that when am performing the LF solution, The Pgen value at bus-1 showing 74.6MW instead of 71.6422 , I have tried several times , Can you please let me know the reason, why was it happened

    • @Power_System_Experts
      @Power_System_Experts Před 3 lety

      Thank you Narayana, basically, the swing bus indicates the system balance. Please check either your one of the generators Pgen value is added wrong (low) or check there may be a mistake in the entry of Pload.

  • @davinasamara1156
    @davinasamara1156 Před 3 lety +1

    Hello,I would like to ask you if you have data from IEEE 14-Bus System in PSS/E and if you can share? Thank you.

  • @habtamuasres4077
    @habtamuasres4077 Před 3 lety +1

    10q very much sir. but
    would u mind sending the parameters like bus data,line data and so on .... or
    if u have a link where do u got those datas ... please share to me

  • @lipubhoi9656
    @lipubhoi9656 Před rokem +1

    where is this data sheet. please provide the link.

  • @mast6footer383
    @mast6footer383 Před 3 lety

    Hello sir

  • @mohamedabdelrashid6328

    May I have your email?