STREET LIGHT TIMER SETTING AND CONNECTION

Sdílet
Vložit
  • čas přidán 13. 09. 2024
  • 24 hour timer for home
    for purchase timer please click link
    amzn.to/3wzHO3x
    In this video we explain street light timer setting, connection and also explain auto and mannual connection with selector switch
    Street light timer also known as 24 hour timer so we can control any of load with this timer and operate with time
    And in many tim we need to operate light or load manualy so by connectiong selector switch u can run your load auto and mannual directly
    In this video we explain really easily with circuit diagram for more information learning just watch and learn
    Cable testing with multimeter
    • HOW TO TEST CABLE WITH...
    Reverse forward starter power wiring connection
    • REVERSE FORWARD STARTE...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    3 phase rccb test on single phase supply practical
    • 3 PHASE RCCB मे SINGLE...
    3 phase ammeter connection with selector switch
    • 3 PHASE AMMETER CONNEC...
    8 pin relay testing with multimeter
    • 8 PIN RELAY TESTING WI...
    How to check ceiling fan common start run with multimeter
    • 3 WIRE CEILING FAN COM...
    How to make dol starter with relay
    • How to make dol starte...
    How to check ceiling fan common start run with series lamp
    • Video
    ammeter connection with current transformer
    • 3 PHASE AMMETER CONNEC...
    Cooler motor testing with series test lamp
    • COOLER MOTOR TESTING W...
    Street light timer setting
    • STREET LIGHT TIMER SET...
    Air compressure power & control wiring practically
    • AIR COMPRESSURE के ST...
    3 phase cable testing with megger
    • HOW TO CHECK CABLE INS...
    3 phase motor test with megger
    • Induction motor test (...
    Dol starter control from different points
    • MOTOR CONTROL FROM DIF...
    How to make reverse forward motor starter
    • How to make Reverse f...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    Thanks for watching

Komentáře • 142

  • @mithunmandal9459
    @mithunmandal9459 Před 4 lety +1

    Bahut bahut bahut Achcha video

  • @rahulsingh7442
    @rahulsingh7442 Před 4 lety

    Very good video

  • @nikeshwaghmare9001
    @nikeshwaghmare9001 Před 4 lety

    👍 nice video sir exlent 🙏

  • @Manavsain00
    @Manavsain00 Před rokem

    Coment to aese karte hai jese sab kuch acche se samajh gaye ho video dekhne wale sab intelligent hai

  • @ishwarcheskar4456
    @ishwarcheskar4456 Před rokem

    Thanks sir ji 🙏

  • @godblessyou9885
    @godblessyou9885 Před 3 lety

    Super ji.
    Masss 👌👍

  • @riyajuddin52
    @riyajuddin52 Před 4 lety

    Thanks.. nice video

  • @sourabhsharma5467
    @sourabhsharma5467 Před 3 lety

    Bhut acche

  • @Deepaksharma-ud2rn
    @Deepaksharma-ud2rn Před 6 lety +4

    Thank you so much sir...apke smjhme ka tarika kabile tarif hai...
    Agar aap jaise teacher rhe to sv students talented honge jise koe Hara nhi skta.. thank you sir.

  • @vijayjoshi4187
    @vijayjoshi4187 Před 3 lety

    Very good

  • @Ytgems21
    @Ytgems21 Před 4 lety

    Bahut sandar samjhaye h sir ji . Thanks sir ji

  • @asifm6312
    @asifm6312 Před 4 lety

    Good yar

  • @sourabhsharma5467
    @sourabhsharma5467 Před 3 lety

    Shandar

  • @aboarqam6500
    @aboarqam6500 Před 3 lety

    Good working

  • @supertailor7617
    @supertailor7617 Před 5 lety

    Bhut a66a video h bhai

  • @newgardening543
    @newgardening543 Před 4 lety

    Nice video

  • @mohdsufiyan6239
    @mohdsufiyan6239 Před 5 lety

    apka video bahut hi saaf n clear h for understanding.
    please 2 motor hai uska uska starting panel design karke btaye . usme timer hai overload relay hai contctor ke sath aur selector switch hai for auto manual n off. aur un dono ko float switch se v control krna hai

  • @hanumanthappakottur9062

    Very nice sir street light electrical timer video

  • @chauhanjatinjatin3856
    @chauhanjatinjatin3856 Před 3 lety

    Very nice and very helpful video sir ji 👌👍👌👌

  • @ranjansahu2362
    @ranjansahu2362 Před 3 lety

    Very nice sir.... Isme selector switch laga jai... Jisme ek local remote aur auto.. 3 mode main chalaye to kese hoga

  • @sunilkumaryadav4423
    @sunilkumaryadav4423 Před 4 lety +1

    Very good sir thanks you sir very help full video

  • @litoncriativity9217
    @litoncriativity9217 Před 4 lety

    Surprising wife ka video banaya nahin hai video song pura samajh mein are yaar bahut acche

  • @IsmailKHAN-gw8ne
    @IsmailKHAN-gw8ne Před 3 lety

    Selected switch connections samaj nhi aaya auto and manual wala. baki sab teek he. Thanks sir selecter switch ke connections live kro next video meh please sir. I wating for you same video

  • @nanakin6169
    @nanakin6169 Před 2 lety +1

    I want to know how to set this timer

  • @mdrahmat9007
    @mdrahmat9007 Před 5 lety

    Thanku kafi achhi video hai

  • @naturalworldutv7111
    @naturalworldutv7111 Před 4 lety

    Good

  • @RaviKumar-tr9xz
    @RaviKumar-tr9xz Před rokem

    Super

  • @MUKEEMKHAN399
    @MUKEEMKHAN399 Před 4 lety

    Very good bhai bahut auche se samjhaya aapne merr pass 1 panel hae usme laight hae kafi sari usme panel me ye sab laga hE lekin is ke sath sath usme sensor bhi laga hae pahle wo auche se kam kar raha tha lekin abhi nahi chal raha hae ab pura direct chal raha hae to mene uska sensor chanje kiiya lekin wo abhi bhi direct hi chal raha hae sensor bhi nahi kam kar raha or timer bhi nahi kar kaam direct hi chal raha hae metlab 24 horse chal raha or ha usme ye auto Manuel swich bhi laga hae usse bhi koi fark nai padh rha so please plese plese plese Ripley me sar kya problam hae usme kya chek kiya jae uska plese plese plese plese plese sar Ripley me plese sar i request u plese sar help me

  • @SP-kf3zr
    @SP-kf3zr Před 4 lety +3

    Awesome sir.. I was exactly looking for something like this..Sir, I want to convert my usually connected bulb into a timer controlled one.. If you could guide me, I would really appreciate that.

  • @kpsinghsingh9268
    @kpsinghsingh9268 Před 4 lety

    U r the best sir ji

  • @rajendrabhalekar4982
    @rajendrabhalekar4982 Před 3 lety

    👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍🌹

  • @dostmuhammad2226
    @dostmuhammad2226 Před 3 lety

    Is ke andar kitne ghante ka back up zida se zida battery dety he?

  • @rajuraju8534
    @rajuraju8534 Před 2 lety

    Ok sar

  • @mddelowarhossain8229
    @mddelowarhossain8229 Před 4 lety

    💕💕

  • @musarazabakaralijalali1720

    Very good nice video sr

  • @ness8583
    @ness8583 Před 6 lety

    Very good teaching sir

  • @surajlugade886
    @surajlugade886 Před 4 lety

    Nice video 👌👌👍👍. Pls upload every video with connection diagram and practically . Very very thx 👍

  • @dostmuhammad2226
    @dostmuhammad2226 Před 3 lety

    Sir , agr do din ke lie bijli fail ho jai to b work kre ga ? Ya ni

  • @shoaibhasan6914
    @shoaibhasan6914 Před 5 lety +1

    Very Nice Video Thanks Brother.

  • @surenderakumar6346
    @surenderakumar6346 Před 4 lety

    Ok sr

  • @sunilraval3889
    @sunilraval3889 Před 3 lety +1

    Praktikal kar ka batao

  • @dostmuhammad2226
    @dostmuhammad2226 Před 3 lety +1

    Sir , agr bijli fail ho jai toh phir be ye work kre ga ya ni?

    • @SNTECHNICAL
      @SNTECHNICAL  Před 3 lety

      Krega work isme back up k liye bettery h

  • @multiprapu1
    @multiprapu1 Před 5 lety +1

    You are fantastic sir

  • @arzookhan5930
    @arzookhan5930 Před 6 lety

    Bahut accha

  • @harekrushnabiswal5053
    @harekrushnabiswal5053 Před 5 lety

    You descride is very simiplysity. I like lov u..

  • @hasanadil8934
    @hasanadil8934 Před 5 lety

    Good explain

  • @sabahathussain3402
    @sabahathussain3402 Před 5 lety

    Good vedio sir pls electrical type diagram also shown

  • @pankajkumar-ix2cj
    @pankajkumar-ix2cj Před 5 lety +1

    Thanks full video... 👌👌👌👌

  • @yeye-rq8yt
    @yeye-rq8yt Před 5 lety +2

    HI Bhai.g aap ki video bahot bahot achhi lagi good information Bhai god bless you 👌

  • @shuaibmohammad5039
    @shuaibmohammad5039 Před 5 lety

    Great video

  • @ambalalnagda2027
    @ambalalnagda2027 Před 5 lety +1

    Super sar

  • @narayanlalyadav4620
    @narayanlalyadav4620 Před 4 lety

    Hi sir aapka batane ka tarika achcha hai,par me ye nahi samjh paya ki,maan lo ki aapney selector switch se manual kar ke motor 1 ghanta chalaya to us 1 ghanta timer me power nahi gaya to timer nahi chalega to aapkey dwara jo setting ki gai hai us samay ke anusar nahi chalega vo 1 ghanta lete chalega,to mere kahney ka matlab ki har bar timer me time set karna padega kya

  • @ajmaljani2452
    @ajmaljani2452 Před 5 lety

    nice bro you are beauty

  • @zishanzaved188
    @zishanzaved188 Před 5 lety

    Nice vedio

  • @karansrikonda4559
    @karansrikonda4559 Před 5 lety

    Kadak

  • @naserkumar5762
    @naserkumar5762 Před 5 lety

    Bahut a66a

  • @ImranAli-yg3ep
    @ImranAli-yg3ep Před 5 lety +1

    Nic brother
    thanks

  • @kumarvickysharma4675
    @kumarvickysharma4675 Před 5 lety +1

    Thanks sir

  • @ashokdobariya6567
    @ashokdobariya6567 Před 5 lety

    Thank you sir

  • @DawoodKhan-vt7wy
    @DawoodKhan-vt7wy Před 4 lety

    Realllyyyyyy good

  • @vasughamot7980
    @vasughamot7980 Před 6 lety +1

    Nice

  • @houstonembroidery8771
    @houstonembroidery8771 Před 5 lety

    thanks

  • @anilkumarghosh4161
    @anilkumarghosh4161 Před 2 lety

    Jab manual me chele ga to Timer ke clock bandh ho jai gi

  • @sujonmahmud4132
    @sujonmahmud4132 Před 3 lety

    আমি জানতে চাছি এই টাইমার কি বিদুৎ চলে গেলে টাইমারে সময় কি টিক থাকে

  • @deepakpatial4134
    @deepakpatial4134 Před 5 lety

    Sir agr manual mein on off ke liye push buttons use krne honge to kya Hume manul wale nc se phase Lena padega

  • @devdev8461
    @devdev8461 Před 6 lety

    Good morning

  • @narayanlalyadav4620
    @narayanlalyadav4620 Před 4 lety

    Sir ji namstey,yadi 2. Ghante tak manual me chalta hai or fir auto me kartey hai to timer me fir se time set karna padega kya

  • @upendarnishad6178
    @upendarnishad6178 Před 5 lety +1

    very ni sir

  • @subhashbeck
    @subhashbeck Před 4 lety

    Kitne pole ka contractor us kiye hain..

  • @hirokjyotinath2246
    @hirokjyotinath2246 Před 4 lety

    Thank you so much for your valuable video lectures
    Sir
    Please make video on remote wiring of submersible water pump starter

  • @ranjansahu2362
    @ranjansahu2362 Před 4 lety

    Sir iss main contractor ka NO main ek.. selecter swich k nc se ek connection Dia hey.. aur contror NO ka dusra point ko kon sa connection denge.. diagram main missing hey

  • @houstonembroidery8771
    @houstonembroidery8771 Před 5 lety

    timer ki supply jo 7-8 mei lagtii he agar wo 4 hrs keley off hojay to kya timers 4 hours peechy hojayga?

    • @sitarampoudel4561
      @sitarampoudel4561 Před 5 lety

      Sir kaise banega only 1 second on Hona Chahiye for 10 minute ke bad for 1 second on kaise Hoga sir?

  • @Raj-cf6fe
    @Raj-cf6fe Před 5 lety +1

    Where can I buy the contractors?.

  • @manojnajuka
    @manojnajuka Před 6 lety

    Timer battery pe chalta hai kya

  • @kennethlobo4420
    @kennethlobo4420 Před 4 lety

    Good explanation .Thank u. Could u pls keep the same colour RED when u are taking connection from phase connection to common point ,of timmer.

  • @nandasarkar664
    @nandasarkar664 Před 4 lety

    Timer chalati samay awaas kiu hoti he

  • @vickysharma2259
    @vickysharma2259 Před 4 lety

    Isme push button kese laga skte hai

  • @hindurashtrrawat483
    @hindurashtrrawat483 Před 5 lety

    Contactor ka neutral or phase ka point batana

  • @sikandarbirua1409
    @sikandarbirua1409 Před 5 lety

    please provide us
    1.components rating and value

  • @sandeepkumar-jk3ij
    @sandeepkumar-jk3ij Před 5 lety

    Timer 5 no se or bi chala sake h

  • @abulfazal5629
    @abulfazal5629 Před 5 lety

    Pictical pus krke nehi krna ham lok pictical dekhana chatehe

  • @VIKASHKUMAR-xc1mk
    @VIKASHKUMAR-xc1mk Před 6 lety

    Sir aap coaching karwate h Kya main join karna chahta hoon

  • @hindurashtrrawat483
    @hindurashtrrawat483 Před 5 lety

    Bahut purani confusion dur kr di brother

  • @vaiducreativechannel8832

    Motor K liye connection kaise kray

  • @simonkarre4409
    @simonkarre4409 Před 6 lety

    3 phases supply me timer kase karte hai please batana sirl

  • @premchandhembram119
    @premchandhembram119 Před 5 lety

    Bhai hum Street light nahi fit Nahi kar pa rahe hai kaya kare reply kare

  • @alokranjanupadhyay3118

    timer ke baad contector laga karke kitna bhi load diya ja sakta hai

    • @SNTECHNICAL
      @SNTECHNICAL  Před 5 lety

      Ha contactor ki kitni ratting hogi itna diya ja skta h

    • @rajukhardia4594
      @rajukhardia4594 Před 5 lety

      Bhot a6a hai bro tnx ase video bnane k liye

  • @pinkrose9062
    @pinkrose9062 Před 4 lety

    Respected sir plz clear two points..
    when main supply fails..timer Will stop or remain continue?
    After completion 24 hours Will it repeat it self forever in 24 hour cycle?

  • @nasirshaikh4749
    @nasirshaikh4749 Před 4 lety

    Sir in k price kya Hote Hain ine chijon kya

  • @vasu615
    @vasu615 Před 5 lety

    First show the parts of timer,tell about needles that are installed ( hour and minutes type needles) and graduation marks details and its divisions and then how it is set and then connections and settings etc;-

  • @kashipal1022
    @kashipal1022 Před 3 lety

    415volt contact 220volt timer c

  • @vivekverma5351
    @vivekverma5351 Před 4 lety

    isme selector switch ko auto me conection kaise kiye iska daigram nhi samajh paya

  • @pulokbiswas7011
    @pulokbiswas7011 Před 5 lety

    3 phase submarshal 440 volt kayse set Kare?

    • @tanweerhassan550
      @tanweerhassan550 Před 3 lety

      Single phase k jagah only 3 phase wala Contracted fix karna hoga & contractor k operating cool tak same single phase connection as it is karna hai & 3 phase supply direct contractor k top input meh deña hai & output meh supply load & ENJOY.

  • @dostmuhammad2226
    @dostmuhammad2226 Před 3 lety

    Bijli jane ke bad kitne ghante tak timer switch on rehta he sir?

  • @mohammadasgarkhan3788
    @mohammadasgarkhan3788 Před 11 měsíci

    Sir ap sld banana Sikh lo bad me teaching karna

  • @janakiram7973
    @janakiram7973 Před 4 lety

    Telugu translate sir

  • @Mahadevkikripa822
    @Mahadevkikripa822 Před 5 lety +1

    वीडियो बहुत अच्छा है पर आप जो डायग्राम में आते हैं उसका 1.pdf छोड़ दीजिए करें इससे सुविधा होगी

    • @SNTECHNICAL
      @SNTECHNICAL  Před 5 lety +1

      Ap video pause krk screenshot le liya kijiye

  • @BaadshahBaadshah-dr4rq

    That min

  • @vikashrajpurohit3351
    @vikashrajpurohit3351 Před 6 lety

    Sir aap konsi company me job krte ho plz tell me

  • @clintonsimba431
    @clintonsimba431 Před 4 lety +1

    I am following your post buy u are using language I DNT understand... Pliz why can't you use English which is a universal language

    • @SNTECHNICAL
      @SNTECHNICAL  Před 4 lety

      Please watch sn technical special for english video