HOW TO INSTALL a Circuit Breaker Double-Pole Breaker EASY AND SAFE!

Sdílet
Vložit
  • čas přidán 7. 07. 2024
  • I highly recommend you turn off the main breaker. In this video I will teach you how to install Circuit Breaker Double-Pole Breaker. UPDATED VERSION of this video ===) • HOW TO INSTALL 220V 24...
    The red and black wires are interchangeable. Can either be top or bottom, it does not matter.
    This video is for educational and entertainment purposes only. Any work perform will be at your own risk.
    Donation to support my channel running:
    www.paypal.com/donate/?busine...
    Want to buy me a cup of coffee? :) www.buymeacoffee.com/kevinpon
    Want to EARN FREE money while shopping online? Over 2500 stores.
    SIGNUP BONUS when you use my link. Join NOW and receive $30 when you spend at least $30 before taxes! Must be done within 90 days of signup.
    FOR USA receive $30USD
    www.rakuten.com/r/KEVINP1127?...
    FOR CANADA receive $30CAD
    www.rakuten.ca/referrer?refer...
    Try Amazon Prime 30-Day Free Trial
    amzn.to/3FmTMoT
    Give the gift of Amazon Prime membership
    amzn.to/3P3r1kq
    Want to EARN THOUSANDS per month as an Airbnb host? Sign up with my link: www.airbnb.ca/r/kevinp11750
    Hungry? Get $10 off your first 2 Uber Eats orders of $20 or more.
    Use my code at checkout: eats-kevp546ue
    ubereats.com/feed?promoCode=e...
    DON'T forget to LIKE this video and SUBSCRIBE to my channel!
  • Jak na to + styl

Komentáře • 120

  • @KevinPon.
    @KevinPon.  Před 3 lety +21

    2:22 *Step #1, I highly recommend you turn off the main breaker.* Newer version of this video: czcams.com/video/qWhul3Pa6mA/video.html

  • @AK3289
    @AK3289 Před 2 lety +7

    Thank you for helping me with mine! Simple job that could go wrong if you miss a step

    • @KevinPon.
      @KevinPon.  Před 2 lety +1

      My pleasure Austin! Glad it all worked out! I 🍻

  • @HobbsBhipp
    @HobbsBhipp Před 2 lety +2

    Thanks for the safety demonstration.

  • @daniellewadman3116
    @daniellewadman3116 Před 2 lety +1

    I love how calm you sound

  • @mainemade300
    @mainemade300 Před 3 lety +21

    We heard that

  • @freddiestewart9233
    @freddiestewart9233 Před 3 lety +1

    Great video thanks for showing this !

  • @sethrich2790
    @sethrich2790 Před 2 lety +1

    Excellent! Nice clear presentation. Thanks!

    • @KevinPon.
      @KevinPon.  Před 2 lety

      My pleasure and you're very welcome, Jack! I made a newer version of that video if you needed another look. Cheers mate! czcams.com/video/qWhul3Pa6mA/video.html

  • @shoja7264
    @shoja7264 Před 2 lety +1

    This is a GREAT VIDEO!!!

  • @jinchoe6354
    @jinchoe6354 Před rokem +2

    I like the swearing when you couldn't get the breaker in the first time lol

  • @ramsuwal9565
    @ramsuwal9565 Před 3 měsíci +1

    informative video , thanks Kevin

  • @goumansf7370
    @goumansf7370 Před 3 lety +1

    Thank you.

  • @georgewilson5303
    @georgewilson5303 Před rokem +1

    Thank you

  • @travisgulley2652
    @travisgulley2652 Před 3 lety

    Are all the circuit breakers in the circuit breaker panels In the United Kingdom Europe and Australia double pole circuit breakers

  • @loveydovey4u
    @loveydovey4u Před 2 lety +1

    Hey can I down size from a 40 amp double pole to a 20 amp double pole? (I got rid of my range and now was to install a mini split)

    • @KevinPon.
      @KevinPon.  Před 2 lety +1

      Absolutely, yes you can 🍻

  • @jironman21
    @jironman21 Před 3 lety +4

    hi Kevin. my dryer is rated for 30 amps and 240 volts. Is a double pole breaker marked 25 amps on each pole acceptable? i was going to install a 30 amp 4 prong outlet for the dryer. thanks in advance

    • @KevinPon.
      @KevinPon.  Před 3 lety +4

      Hi Jamesley. The answer is, it "could" work. "But" your breaker could trip once the dryer needs or requires more power than 25 amps. So you will have to see if your dryer will trip the breaker or not 🍻

  • @yanggao2343
    @yanggao2343 Před rokem +1

    Tks for sharing. Question - I haver a 110V panel, and 40 amp breaker in place. Question, I have a baler that takes 40 amp. Do I just plug in one hot wire to the breaker?

    • @KevinPon.
      @KevinPon.  Před rokem

      I am going to assume there will be 2 hot wires. 1 red, 1 black and the neutral possibly? Have to read the specs on the baler. If it's 240V then you will need a double pole breaker. Two hot wires that plug in the breaker 🍻

    • @yanggao2343
      @yanggao2343 Před rokem +1

      Actually the baler is 110V and thus only have one hot one neutral and one ground. So hence my question, if I hook up to one screw on the breaker with hot wire, that gives me 110V. Question is would this get me 40amp (and breaks at above 40amp?).

    • @KevinPon.
      @KevinPon.  Před rokem

      Yes, you would get up to 40 amps 🍻

  • @rabinzx
    @rabinzx Před 3 lety +1

    What awg of wire you use? What gang box for you use for the other end?

    • @KevinPon.
      @KevinPon.  Před 3 lety +1

      Different applications uses different breaker size, different gauges and different boxes. Example: 15A plugs uses 14awg wire, 20A plugs + 12awg, 30A dryer plug + 10awg, 40A range + 8awg, 60A Tesla faster charger use 6awg 🍻

  • @treuthconductor8979
    @treuthconductor8979 Před 3 lety +2

    I like the way you teach class clear concise

  • @gusmartinez90
    @gusmartinez90 Před rokem +1

    Hey yah

  • @Albertojedi
    @Albertojedi Před 2 lety

    Hello. Are those gloves made of any specialty insulator material?

  • @SlickWorks
    @SlickWorks Před 3 lety +2

    Great video. Red and black is covered, Im just wondering what to do with the white wire and the ground now though

    • @KevinPon.
      @KevinPon.  Před 3 lety +2

      Thank you! Sorry about that. The white will be screwed down on the neutral bar with the rest of the white. The ground with be with the rest of the ground. Here's a more recent video czcams.com/video/pTq6NmAdJSk/video.html

    • @SlickWorks
      @SlickWorks Před 3 lety +2

      @@KevinPon. I figured it out today thanks!! installed my first breaker in my shop!

    • @KevinPon.
      @KevinPon.  Před 3 lety +2

      @@SlickWorks that is awesome! Congrats on your success! 🍻

    • @daddywoofdawg
      @daddywoofdawg Před 3 lety +1

      Is that for a 115v or a 220v? If for a 220v what do you do for 110v?

    • @KevinPon.
      @KevinPon.  Před 3 lety +1

      @@daddywoofdawg Double-Pole is for 220-240V. For an example an oven uses 220v for the heating coil and 110v for lights and other components.

  • @johnnypoppyhead4116
    @johnnypoppyhead4116 Před 3 lety

    insulation an 30 amp breaker ..so the white is grounded??

  • @knaightmare9598
    @knaightmare9598 Před 4 lety +5

    I see that you connected the red wire on the top terminal of the breaker and the black on the bottom. Do they always have to be in this order or are they interchangeable. Black on the top terminal and red on the bottom?

    • @KevinPon.
      @KevinPon.  Před 4 lety +8

      Thanks for bring up that question. On a double pole breaker, either color can go top or bottom. It does not matter.

    • @knaightmare9598
      @knaightmare9598 Před 4 lety +2

      @@KevinPon. Thanks, I was able to connect a new 30 amp breaker for a new water heater.

    • @KevinPon.
      @KevinPon.  Před 4 lety

      @@knaightmare9598 You're very welcome! That is awesome!

    • @zackpercellvo7923
      @zackpercellvo7923 Před 4 lety +2

      Is there supposed to be an either white, green or non insulated ground wire, too? All the other vids I've seen on this subject have it but I don't really understand it. I'm just interested in how it all works.

    • @KevinPon.
      @KevinPon.  Před 4 lety +1

      @@zackpercellvo7923 Yes there is! I should've put it in the video too. The white wire is your (neutral wire) it goes on the neutral bus bar. It connects all the wire wires together. The bare or green insulated wire goes on the ground bar with the rest of the grounded wires. Hope this helps. Cheers!

  • @gbreezie
    @gbreezie Před rokem +1

    So both wires connect to the breaker? No wire connects to the panel? Like the white one usually does

    • @KevinPon.
      @KevinPon.  Před rokem

      Correct both red and black is connected to the breaker only. And the white wire to the neutral bar 🍻

    • @oiooio6087
      @oiooio6087 Před rokem

      why does my uncle only have positive to the breaker and the negative not connected to the breaker at all but to the ground side

  • @kene8895
    @kene8895 Před 2 lety

    Where were you placing the wires your hand was in the cameras way

    • @KevinPon.
      @KevinPon.  Před 2 lety

      Sorry about that! Hope this video will be better czcams.com/video/qWhul3Pa6mA/video.html

  • @gw9450
    @gw9450 Před rokem

    It helps when it not so much explanation and more doing

    • @KevinPon.
      @KevinPon.  Před rokem

      It helps when you press fast forward

  • @ursala3000
    @ursala3000 Před 3 lety +2

    Hey brother, is there a way I could DM you and ask you electrical related questions? I really need some advice.

    • @KevinPon.
      @KevinPon.  Před 3 lety

      Yeah bro send me your email

    • @m16club2
      @m16club2 Před 3 lety

      L

    • @joeylopez9277
      @joeylopez9277 Před 3 lety +1

      @@KevinPon. I'd like to ask a question as well. How can I reach you? Thanks for the video.

    • @KevinPon.
      @KevinPon.  Před 3 lety

      @@joeylopez9277 what's your email?

    • @joeylopez9277
      @joeylopez9277 Před 3 lety

      @@KevinPon. Joeylopez7@gmail.com

  • @Silojohnson
    @Silojohnson Před rokem +1

    Jus shut the main off. They make really nice flashlights these days.

  • @theeffindip6162
    @theeffindip6162 Před 4 lety +3

    Can you put the wires in first then put it on

    • @KevinPon.
      @KevinPon.  Před 4 lety +1

      Yes you can. But make sure the breaker is in the off position

  • @unassailablefacts
    @unassailablefacts Před 2 lety +1

    Is it possible to make a mistake and install the white and black wires to the breaker the wrong way? Meaning r they interchangeable. The white where the black used to be and vice versa.

    • @KevinPon.
      @KevinPon.  Před 2 lety

      Mistakes can happen but just have to pay attention. They cannot be interchangeable 🍻

    • @unassailablefacts
      @unassailablefacts Před 2 lety

      @@KevinPon. but the air handler and condenser started working and the 2 pole 20 amp breaker did not trip. Maybe that’s how I should be wired? Black on the bottôm and white on top

    • @KevinPon.
      @KevinPon.  Před 2 lety

      @@unassailablefacts check out this video czcams.com/video/qWhul3Pa6mA/video.html
      You never put white and black on the load side of breaker

    • @jessemclaughlin9680
      @jessemclaughlin9680 Před rokem +1

      You can sometimes use the white as a load wire, but you should indicate that with red tape on the white wire.

  • @sheltonhall6036
    @sheltonhall6036 Před 3 lety +1

    Was there no ground wire in the circuit?

    • @KevinPon.
      @KevinPon.  Před 3 lety +1

      There is one. I've made a newer video with the wires with demonstration. czcams.com/video/pTq6NmAdJSk/video.html

    • @sheltonhall6036
      @sheltonhall6036 Před 3 lety +1

      @@KevinPon. Came in handy today! Thanks for the upload.

    • @KevinPon.
      @KevinPon.  Před 3 lety

      My pleasure 😎🍻

    • @sheltonhall6036
      @sheltonhall6036 Před 3 lety +1

      @@KevinPon. Earned a sub too!

    • @KevinPon.
      @KevinPon.  Před 3 lety

      Thank you, thank you! I really appreciate it Shelton!

  • @FloridaMark1611
    @FloridaMark1611 Před rokem +1

    Step 1: Have a decent panel.

  • @shuha24
    @shuha24 Před 3 lety

    What's that red wire? Where are the grounded neutral, ground wires?

    • @KevinPon.
      @KevinPon.  Před 3 lety

      Hello, there's a red and a black wire. For a range for an example (black 120V) + (red 120V) = 240V
      Here's an updated video czcams.com/video/pTq6NmAdJSk/video.html

  • @-smp-scientificmethodpersp838

    Where is the neutral wire? (It's white for anyone else reading this that's wondering)
    Which is which with the red and black?
    Which or where is the ground wire? (Green)

    • @josephrostkowski674
      @josephrostkowski674 Před 3 lety +1

      Know this, electricity is color blind. Don't trust color, trust your intrustment of testing. Voltage with travel through any wire no matter what color. In a perfect world colors help,but don't ever trust the person that works on it before you.

    • @josephrostkowski674
      @josephrostkowski674 Před 3 lety

      Electrons are color blind USE YOUR TESTING INSTRUMENT. IF YOU DONT UNDERSTAND WHAT YOUR METER IS TELLING YOU. CALL A LICENSE ELECTRICIAN.

    • @-smp-scientificmethodpersp838
      @-smp-scientificmethodpersp838 Před 3 lety +1

      @@josephrostkowski674 I know how. I'm certified for this. I just think it should be in the video. This comment for for the content maker. It doesn't take a licenced electrician to do this. Good content though, and good comment comment from u 2. Never trust the colors lol both our comments should be in the video for educational purposes.

  • @xIGOTUx1
    @xIGOTUx1 Před 3 lety +6

    I like the way you explain things. But you said nothing on how to uninstall a breaker. Not even explaind what the wires are or where the red and black wires go.

    • @KevinPon.
      @KevinPon.  Před 3 lety +1

      Sorry about that, this is for installation. But to uninstall a breaker all you would have to do is follow the steps backwards. Where the red and black wires plug on to, either top or bottom works. It does not matter.

    • @xIGOTUx1
      @xIGOTUx1 Před 3 lety +1

      @@KevinPon.You did a good job. I just figured adding that to your video would be a helpful tip to your viewers.

    • @KevinPon.
      @KevinPon.  Před 3 lety

      Yes, you are definitely right! I'll have to make another video.

    • @-smp-scientificmethodpersp838
      @-smp-scientificmethodpersp838 Před 3 lety

      @@KevinPon. did you make it yet?

    • @KevinPon.
      @KevinPon.  Před 3 lety +1

      @@-smp-scientificmethodpersp838 unfortunately not yet. Hopefully within the week

  • @darrellcuellar7861
    @darrellcuellar7861 Před 2 lety

    Supposed to be torqued at 30in lbs

  • @ram43x80
    @ram43x80 Před 3 lety +1

    Where was ur ground?

    • @KevinPon.
      @KevinPon.  Před 3 lety

      Hi Ram, sorry about that. The ground wire is on either left side or right side near the edge of the panel. You will see it. All with your ground wire together. Here's a new video that has the ground wire showing around the 10 minute mark. czcams.com/video/qWhul3Pa6mA/video.html

  • @StoneSoupVideos
    @StoneSoupVideos Před rokem +2

    Appreciate the tutorial but there's no way in hades i'll do anything without turning off the main breaker first. Electricity takes the path of least resistance through the body, and a lot of it will actually arc around your body as it heads toward the ground. It will not be a good day for you, and likely your last day as well.

    • @KevinPon.
      @KevinPon.  Před rokem

      Yes, better be safe than sorry 🍻

  • @JAHBOAN
    @JAHBOAN Před 3 lety +2

    "Ahh fuck" :)

  • @Tigereyes502
    @Tigereyes502 Před 3 lety +4

    Anyone else get nervous lol

    • @KevinPon.
      @KevinPon.  Před 3 lety

      😂

    • @rustybarrelhomebrewing1017
      @rustybarrelhomebrewing1017 Před 3 lety +3

      lol yep, the moment when he said "you could die"

    • @KevinPon.
      @KevinPon.  Před 3 lety

      🙈😂

    • @Lawless187indika
      @Lawless187indika Před 3 lety +2

      @@rustybarrelhomebrewing1017 lol.. right?..😂and said it so eerily calm and friendly. Lil Hannibal Lecter Professional electrician .. lol GOod video KP

    • @KevinPon.
      @KevinPon.  Před 3 lety

      😂 thank you my friend

  • @claytonosborne313
    @claytonosborne313 Před rokem

    Could you have , i don’t know, zoomed in a little? Or shown the old one coming out? Lame

    • @KevinPon.
      @KevinPon.  Před rokem

      Try this one 🍻 czcams.com/video/pTq6NmAdJSk/video.html