How to connect Encoder with S7-1200 ? || High Speed Counter HSC || TIA PORTAL || Lesson#13
Vložit
- čas přidán 9. 07. 2024
- #Encoder #TIAPortal #Siemens #Simatic_manager #leaning #progamming
Complete training series of Simatic Manager and TIA portal please check it out also
Please subscribe to my channel
Encoder with PLC
using encoder with the PLC S7 1200
00:00 Introduction
00:22 What is Encoder ?
00:48 wiring diagram of Encoder
01:16 Encoder wiring with S7 1200 PLC
02:07 Encoder programming in TIA Portal
04:20 Testing Encoder program
keep up the good work. There are many channels with the Siemens tia portal, but not many that are as informative as yours
you saved our day with this information ... thanks
Great vídeo, thanks a lot.
Great explanation sir thank you.
Very helpful especially wiring
simple & accurate
very good work.
Thank you so much bro i wish to continu like this video
Thanks for the explanation.
Could you tell me where to buy the Seiki CB2000-HC encoder? I tried searching but without success. Thanks in advance.
Thank you so much
Thank you very much
Thank you
Why is Z signal connected to I0.2? Does it have any sense here? According to S7-1200 manual, only A/B signals are needed.
Can i change the input in monitor mode without using encoder??
By the way...in this wiring diagram I suppose that your Rotary Encode is NPN output (If not --- PNP--- M (0V) must be connected to 1M.... that`s right?)
The jumpre on L+and1m error
Great video! Can I know why all three encoder signal wires are connected to the PLC?
Good question! three wires to detect if the encoder is moving in CW or CCW direction
Good tutorial. But one think i cant figure out. Where is the Orange cable Z-phase I0.2? Cant see it in Hardware Inputs?
Yes its i0.2
2000 pulses per Revolution, how is it possible for this small encoder ????
Sir please same program in omron plc cx-program
Nice video.but how we get reset input the encoder
Bhai, encoder se motor ka rpm kis tarah calculate ka sakta hein siemens mein
Calculate no. Of pulses in 2 seconds and multiply with 30 to get rpm
Thankyou
Can you do a video of a stepper motor connection and programming
I will try to setup ....
Thanks i am working on s7 1200 1212c ac/dc/rly that would be very helpful
@@EASYPLCTRAINING Yes, it would be great!
How to connect two or more encoder in one plc
You can install encoder input cards with the plc
why +24V is connected to 0V?
F
How to reset count value ?
Move zero in the data register
@@EASYPLCTRAINING is there any option for external reset ?
Connect a push button with the PLC, use thus push button signal to move the zero to the encoder data register
@@EASYPLCTRAINING should we move zero in IW1000 or QW1000?
@@EASYPLCTRAINING can we do like this - "Since pulses are DInt format, after counter finishes counting until 2147483647, then can i move "1" to ID1000 directly, so that the cycle repeats?
why the counter value reach out to 1700.....??? it must be 1500 only ??? I'm right
non si vede bene
How about S7-1500 HSC ?