Re-Winding A Transformer for 800W Inverter 12V To 220V

Sdílet
Vložit
  • čas přidán 12. 10. 2022
  • Hi friends in this video i will Re-Winding a 800W Transformer for inverter 12V to 220V .
    information about winding
    primary High Voltage:
    0.8 mm 2x (30Turns)
    200V To 300V output
    Secondary Low Voltage:
    0.8 mm 6× ( 6-0-6 Turns For 400W ) Or ( 4-0-4 for 600W ) Turns
    11V To 13V Input High Frequency
    Use any transformer from
    EE-28 or EC-35 Transformer. form Powersupply like 400W or 800W but Your inverter circuit must Have Feedback to Stabilize the output voltage.

Komentáře • 30

  • @Electronic_For_You
    @Electronic_For_You  Před rokem +4

    👇👇👇!Attention! 👇👇👇
    Primary ( 5+0+5 )
    Secondary ( 25+25) = 110V
    ------------------------------------
    Primary ( 5-0-5 )
    Secondary ( 40+40 ) = 230V
    Watch part-2
    👇👇👇👇👇👇👇👇👇👇👇
    czcams.com/video/TN5wTN5_jTs/video.html

    • @segunjoseph8811
      @segunjoseph8811 Před rokem

      Does it mean that the secondary also will have a center tap or what does 25+25 and 40+40 means

    • @Electronic_For_You
      @Electronic_For_You  Před rokem +2

      25turns 5lair of tape then another 25 turns

  • @rishad100
    @rishad100 Před rokem +4

    Nice video as always 🔥🔥🔥. Broo Make a 2 input and 2 output ZVS driver !!!

  • @RayS-zh5we
    @RayS-zh5we Před rokem

    Alot of talent you have my friend 👍great video thanks have a great day 🙏🌞

  • @MdSamir-xy2tc
    @MdSamir-xy2tc Před rokem

    Very nice

  • @16BITMEME
    @16BITMEME Před rokem +1

    Good 👍

  • @kalashnikov_47z
    @kalashnikov_47z Před rokem +1

    Nice video 👏

  • @ahmedkaram40
    @ahmedkaram40 Před rokem

    Can you help me make a circuit that controls 50 volts and 20 amps

  • @AhmedAli-pu3le
    @AhmedAli-pu3le Před 28 dny

    Can you send ferrite core plugs, because I have many ferrite transformers

    • @Electronic_For_You
      @Electronic_For_You  Před 28 dny

      Sorry I can't because I don't have any more ferrite Transformers

    • @AhmedAli-pu3le
      @AhmedAli-pu3le Před 28 dny

      @@Electronic_For_You What are the sizes of the ferrite that you worked on in the video and wound the copper wire? I mean

  • @hichamtassi1753
    @hichamtassi1753 Před měsícem

    Good day sir. Can i reuse copper wires that i removed from transformer ? Thank you.

    • @Electronic_For_You
      @Electronic_For_You  Před měsícem

      Yes

    • @hichamtassi1753
      @hichamtassi1753 Před měsícem

      @@Electronic_For_You Thank you for your answer. What would be the number of turns to have 12v 310v (for sine wave) ?

    • @Electronic_For_You
      @Electronic_For_You  Před měsícem

      I have the latest video on it

    • @hichamtassi1753
      @hichamtassi1753 Před měsícem

      @@Electronic_For_You I did not find it, can you please send the link.

  • @quickfixengineeringltd8035

    How many turns and whats wire guage

    • @Electronic_For_You
      @Electronic_For_You  Před rokem

      This is not correct,
      I recommend checking the latest video about this !

  • @satveerbajwa2570
    @satveerbajwa2570 Před měsícem

    24 tu220

  • @jammmkhaei6966
    @jammmkhaei6966 Před rokem

    confuse it . i dont lean.

  • @jammmkhaei6966
    @jammmkhaei6966 Před rokem

    very dificult as u dont explain about it.