Capillary Tube Data Chart for R290, R134a, R600a, R404a

Sdílet
Vložit
  • čas přidán 31. 05. 2024
  • HVAC CZcams Channel in English Language:
    / @ayanmechanical
    My official Facebook Page “Engr Farman Khan”
    profile.php?...
    WhatsApp Group “HVAC with Engr Farman
    chat.whatsapp.com/BWNFh3gD2n3...
    My Whatsapp : +92 3059126576
    #capillarytubesize
    #ThermostaticExpansionValve
    #CapillaryTube
    Some Important video Links....
    Capillary Tube Data Chart for R290, R134a, R600a, R404a
    • Capillary Tube Data Ch...
    Capillary Tube Data Chart for R-22, R-410A, R32
    • Capillary Tube Data Ch...
    How Refrigerator works || Refrigeration Principles Practical
    • How Heat Transfer in R...
    Different Capillary Tubes Vs TXV valve || Effects of capillary Tube size increasing or decreasing
    • Capillary Tubes Vs TXV...
    R600a Vs R134a Electrical Power Consumption
    • R600a Vs R134a Electri...
    Refrigerant recovery information || How to recover Refrigerant 134a from refrigerator.
    • Refrigerant recovery i...
    Capillary tube,
    capillary tube selection chart,
    capillary tube size calculation,
    capillary tube experiment,
    capillary tube size chart,
    capillary tube pressure,
    capillary tube change,
    capillary tube dia & length chart,
    refrigerator capillary tube size,
    Thanks for visiting my CZcams channel " FK mech official "
  • Věda a technologie

Komentáře • 73

  • @mansarhayat4543
    @mansarhayat4543 Před měsícem +1

    اللہ پاک فرمان بھای کی زنداگی کرے اس طرح کے لوگ بہت کم جو فری میں سکھا رہے ہے

  • @BilalKhan-ss2tp
    @BilalKhan-ss2tp Před měsícem +2

    Nice video sir ji

  • @jilubhai5255
    @jilubhai5255 Před měsícem +1

    Masha Allah beutiful video Bhai jann 💐💐💐💐

  • @user-uo4uh9rh3d
    @user-uo4uh9rh3d Před měsícem +2

    Good job 👍👍👍

  • @obaidish
    @obaidish Před měsícem +1

    Mashallah very nice video sir

  • @prakashgotame8875
    @prakashgotame8875 Před měsícem +1

    Good information sir

  • @rashidshaikh7171
    @rashidshaikh7171 Před měsícem +1

    Mr. F. K. Sir you is heartly teaching, suggesting technically guidence to HVAC job worker and students thanks

  • @TheAkash2818
    @TheAkash2818 Před měsícem +1

    Great sir ji 👍

  • @preetdatta5353
    @preetdatta5353 Před měsícem +1

    Very informative ℹ️👍🏽

  • @nayanjagirdar8408
    @nayanjagirdar8408 Před měsícem +1

    Nice sir 👌👍

  • @jorgealbertoretro4821
    @jorgealbertoretro4821 Před měsícem +1

    I´m from Mexico . . . Excellent information🙂

  • @swalehmuhammad2428
    @swalehmuhammad2428 Před měsícem +1

    Dear sir mujhe ya video achi lagi ap nay maree ak mushkil hal nikal diya Allah ka hukam say laki ak or masla ya hay ka

  • @msaifali6294
    @msaifali6294 Před 20 dny

    MashAllah

  • @Ganeshkaushalp07
    @Ganeshkaushalp07 Před měsícem

    Shukriya bhai

  • @user-bu9hw8ie2z
    @user-bu9hw8ie2z Před měsícem +1

    Nic

  • @keyurdabhi2340
    @keyurdabhi2340 Před měsícem

    hi sir,
    Your channel is a very good source of refrigeration knowledge. Thank you for all the knowledge.
    condensing & evaporating temperature ka data kaise decide karte hai?
    Kya evaporating temperature is minimum temperature of the system given by system manufacturer?
    Condensing temperature kaise decide kare?
    Aur sir ek aur detail video banaye ki size of capillary & condenser pipe & length kaise decide kare compressor e hisab se ? Please....

    • @FKmechofficial
      @FKmechofficial  Před měsícem

      The condenser & evaporator temp: is decided by manufacturer as per requirement of the unit using in specific conditions,
      Jaise ap kisi AC unit ke zariye agar room temp: 16⁰C tk maintain karna chahe, to manufacturer usss AC unit ka evaporator temp: taqreeban -5 tk rake ga,
      Isssi Tarah isss unit ka coil temp: taqreeban 0⁰C,
      Isssi tarah isss unit ka grill temp: taqreeban 9⁰C,
      Awr room temp: 16⁰C maintain hoga

    • @keyurdabhi2340
      @keyurdabhi2340 Před měsícem +1

      @@FKmechofficial sir ji,
      agar me nayi system design karna chahu to ye sab details kis basis pe decide kar sakte hai?

    • @FKmechofficial
      @FKmechofficial  Před měsícem

      @@keyurdabhi2340 Heat load calculation awr Refrigerant PH chart se

  • @hajmohamed3374
    @hajmohamed3374 Před měsícem +2

    Sir, visi cooler, bottle cooler capillary data videos please.

  • @meditationbiswas3741
    @meditationbiswas3741 Před 28 dny +1

    Excellent Sir. Please give an idea of what is the evaporator copper tube length of 1/4" dia . And what will be the condenser length of 3/16" dia for a 1/4 Compresso and a capillary tube of 0.032.

    • @FKmechofficial
      @FKmechofficial  Před 28 dny

      Evaporator length 50 ~ 60 ft,
      Condenser length 75 ft

  • @gpsjoybhai273
    @gpsjoybhai273 Před měsícem +3

    deep freez ka capillry deta bataye sir ji

  • @meditationbiswas3741
    @meditationbiswas3741 Před 28 dny +1

    The condenser made of iron

    • @FKmechofficial
      @FKmechofficial  Před 28 dny

      In mostly refrigerators, condenser made of iron and In air conditioners condenser made of copper

  • @nidaassociates7441
    @nidaassociates7441 Před měsícem +2

    Ek aur refrigerant hai but apne nahin likha hydrocarbo

  • @user-jy5xd3hd3o
    @user-jy5xd3hd3o Před měsícem +1

    deep freezer ma be kya yai deta use kya ja skta ha ya us k ala sy calculation ho gi ??

    • @FKmechofficial
      @FKmechofficial  Před měsícem

      No Dear, Deep freezer me data tora sa change hota hai

  • @patelbrijal241
    @patelbrijal241 Před měsícem +1

    Sir fan cool conditioner & fan heat exchangr evaporator me bhi ae chalega

  • @kashmirrokerz7889
    @kashmirrokerz7889 Před měsícem +2

    Sir deep freezer ki capilary kitne hone chahye

    • @FKmechofficial
      @FKmechofficial  Před měsícem +2

      Next video me deep freezer Ka data chart banawonga Insha Allah

  • @abdulraheemthebo8212
    @abdulraheemthebo8212 Před měsícem +1

    Sir agr hum ek sada compressor ki jagah ek inverter compressor use karen to us k liye hamen kon c cheezen dekhni parengi

    • @FKmechofficial
      @FKmechofficial  Před měsícem

      Bhai hr aik chiz dekni hai, condenser evaporator, capillary tube but most important capillary tube ko zaroor compressor ke mutabiq honi chahye

    • @abdulraheemthebo8212
      @abdulraheemthebo8212 Před měsícem +1

      Sir agr time miljaey to is per ek rehnumai wali video banaden plz

    • @FKmechofficial
      @FKmechofficial  Před měsícem

      @@abdulraheemthebo8212 Insha Allah zaroor

    • @abdulraheemthebo8212
      @abdulraheemthebo8212 Před měsícem +1

      Thank you very much sir may allah bless you long and healthy life❤❤❤❤❤

  • @swalehmuhammad2428
    @swalehmuhammad2428 Před měsícem +1

    Please air rehnumai farmay

  • @asadkhan9887
    @asadkhan9887 Před měsícem +1

    Assalamualaikum Bhai me Karachi se hon ap se mulaqat karna chahta hon mera ice cream ka kam kuch mashwara karna he

    • @FKmechofficial
      @FKmechofficial  Před měsícem

      Wa Alaikumussalam,
      G Janab me Bannu se hon.
      Abhi issi waqt mera Ghar Taxila me hai.
      Awr currently me Haripur me Technical college me Job kar raha hon

  • @mohanv9483
    @mohanv9483 Před měsícem +1

    Lbh means sir

    • @FKmechofficial
      @FKmechofficial  Před měsícem +1

      LBP means, low back pressure,
      Evaporator temp: -5⁰C ke below

    • @mohanv9483
      @mohanv9483 Před měsícem +1

      @@FKmechofficial thank you sir

  • @swalehmuhammad2428
    @swalehmuhammad2428 Před měsícem +2

    Manay single door deep freezer ma capillary change ki hay or wo 134 ka system tha us ma manay 290 dali hay lakin ice nahi arahi sido per or return bhe achay say arahi hay back presdure 8 hay

    • @FKmechofficial
      @FKmechofficial  Před měsícem +1

      Agar unit me koyi awr issue nhi hai, to pir back pressure 12 SE 15 tk rak Lo bhai

    • @FKmechofficial
      @FKmechofficial  Před měsícem +1

      Leken R290 gas liquid halat me charge karna chahye

    • @swalehmuhammad2428
      @swalehmuhammad2428 Před měsícem +1

      Sir g apki sari bat sahi hay lakin capillary .32 ki dali hay or pressure bhe 15 kiya lakin phir bhe sido per ice nahi arahi poori rat ma ak katora bhe nhi jamaya kiya karna chahiya

    • @FKmechofficial
      @FKmechofficial  Před měsícem

      @@swalehmuhammad2428 condenser ki temp: IN our OUT kiya hain

    • @swalehmuhammad2428
      @swalehmuhammad2428 Před měsícem +1

      @@FKmechofficial sir temp meter nahi hay is liya condensor ka temp note nhi kiya