HVAC Interview Questions and Answers | HVAC Job Interview Part-1 in Urdu/Hindi

Sdílet
Vložit
  • čas přidán 12. 09. 2024
  • This is the HVAC interview questions and answers/ HVAC Job Interview Part-1/ HVAC questions and answers in Urdu/ Top HVAC interview questions/ HVAC Interview Part-1 video for engineering job searching candidates. In this series of videos, I will explain the job interview questions and answers asked commonly regarding HVAC in a simple way in Urdu/Hindi language. This is basic Heating, Ventilation & Airconditioning (HVAC) information for juniors or beginners as well as senior Engineers, Technical Staff, and hope, this video will be helpful to learn & grow for you. If you found anything which is inappropriate then convey it in the comments for my information and rectification in the future.
    Following HVAC questions' answers explained:
    0:37 What is the difference between a 2 way valve and a 3 way valve?
    3:33 Which is better 2 way or 3 way valve according to the HVAC system?
    7:07 Where do we use 2 way and 3 way valves in chilled water and why?
    11:18 What is the difference between 3 way mixing and diverting valve?
    13:54 Can 3 way valve be converted into 2 way valve?
    15:05 How to draw a sketch of FCU and Pump chiller water connection with all accessories?
    You can watch more of Tanweer Ahmed's following related videos:
    1. Project Closeout Requirements | Part-1
    Video's Link: • Project Closeout Requi...
    2. Project Closeout Requirements | Part-2
    Video's Link: • Project Closeout Requi...
    3. Construction Sequence of Projects | Section-1
    Video's Link: • Construction Sequence ...
    4. Construction Sequence of Projects | Section-2
    Video's Link: • Construction Sequence ...
    5. Construction Sequence of Projects | Section-3
    Video's Link: • Construction Sequence ...
    6. Visit of Mechanical Workshop | Pipe Fabrication
    Video's Link: • Visit of Mechanical Wo...
    7. Visit of SASA Metal Industries for fans
    Video's Link: • Visit of SASA Metal In...
    8. What is BIM ? | Building Information Modeling
    Video's Link: • What is BIM ? | Buildi...
    9. Interview Questions and Answers by Construction Mechanical Engineer
    Video's Link: • Interview Questions an...
    10. MEP Engineering | Introduction to MEP
    Video's Link: • What is MEP Engineerin...
    11. MEP Project Engineer | Roles and Responsibilities
    Video's Link: • MEP Engineer Roles and...
    12. Maintenance Engineer | Roles and Responsibilities
    Video's Link: • Maintenance Engineer J...
    13. HVAC Interview Questions and Answers | HVAC Job Interview Part-2
    Video's Link: • HVAC Interview Questio...
    14. HVAC Interview Questions and Answers | HVAC Job Interview Part-3
    Video's Link: • HVAC Interview Questio...
    #TanweerAhmed #hvac #interview #questions #answers #mep #engineering #mechanical
    = YOU CAN FOLLOW ME ON SOCIAL MEDIA =
    WEBSITE: engineertanwee...
    FACEBOOK: web.facebook.c...
    INSTAGRAM: / tanweersethar
    LINKEDIN: / tanweer-ahmed-00142631
    CZcams: / tanweerahmed
    TIKTOK: vm.tiktok.com/...
    TELEGRAM GROUP: t.me/hvacmepenggg

Komentáře • 136

  • @TanweerAhmed
    @TanweerAhmed  Před 2 lety +4

    Part-2 video link: czcams.com/video/-lyDKsepLHg/video.html

  • @jamal6626
    @jamal6626 Před 2 měsíci +1

    Sir, aap ka bahut shukriya itni informative videos banane ke liye. Interview me ek question pucha gaya mujhse ki "3 Way Valve ko return ke bajay supply line me laga sakte hai ya nahi".
    Please iska answer de aap.

    • @TanweerAhmed
      @TanweerAhmed  Před 2 měsíci

      DRV/Balancing/2-way/3-way vales is used for control chilled water flow as per design requirements which is installed return pipeline.
      It is normally installed on return because of the following reasons:
      1. ASHRAE Recommendations.
      2. The coil of the unit should be flooded in case the valve is closed.
      3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment.
      4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.

  • @shahidansari9139
    @shahidansari9139 Před 2 lety +3

    Thanks for making useful video...Keep it up.May Allah increase you in knowledge.

  • @yaqoobgrandsonsengineering6817

    Salute you our Hero Tanveer Ahmad

  • @user-xb8vp9fi2b
    @user-xb8vp9fi2b Před 11 dny

    Bhut khoob .bhut acchi trhaa se explain krte hain aap

  • @TradingHeights
    @TradingHeights Před 8 měsíci +1

    your videos are very helpful sir, im working as a modeller, please make videos on quality control topic on navisworks, how to detect clashes and report them to the designers who are working on revit software., naviswork software pe
    ek playlist bana dijiye

  • @muqudiskhattak434
    @muqudiskhattak434 Před 7 měsíci +1

    your videos are highly helpful... keep it up

  • @Gulbarga_notebook
    @Gulbarga_notebook Před 2 lety +1

    And also in 2-way valve system differential pressure transmission is required. In least points sense the proper temperature, and flow meter also required to modulate the flow which is interfaced with the bms system

  • @rohanrajhasim8332
    @rohanrajhasim8332 Před 2 lety +2

    Very good and thanks so much

  • @mohammedkirmanisyed7960
    @mohammedkirmanisyed7960 Před 2 lety +2

    In my interview ,the question asked was.. why there are pressure gauges on pump suction and discharge and it's importance?

  • @mrhussainimamkhan1233
    @mrhussainimamkhan1233 Před 2 lety +2

    intresting video sir

  • @shadabrehman709
    @shadabrehman709 Před 2 lety +1

    Very good information.

  • @MereKaranArjun
    @MereKaranArjun Před 2 lety

    Very very informative video sir...
    Thanks a lot...
    And ed Mubarak

  • @ferozkhanpathan2310
    @ferozkhanpathan2310 Před rokem +1

    Assalam alaikum sir,,,,,, thank your for your all videos for sharing knowledge.
    I have 1 doubt, that 2 way valve is used in return line for AHU or FCU . But for chilled water HI-Wall unit which is wall mounted like split AC why we connect 2 way valve in supply line?? Please answer

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      You can install in supply line but if you install in return line the it will be more beneficial

  • @funtvwithamnaandhassan8674

    excellent bro
    very nice explantation

  • @imranalisoomro1844
    @imranalisoomro1844 Před rokem +1

    walikum salam sir ,very great knowledge provide, and hard work. but i personal request you some videos make in sindhi language for HVAC filed.

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      سنڌي ۾ ويڊيو ڏسڻ وارا گھٽ آھن

  • @technicalviews6207
    @technicalviews6207 Před 2 lety +1

    Well done Sir ,kindly HVAC design thumb rules pa video bnaen buildings and industries ka lia .

  • @HVACR786
    @HVACR786 Před 9 měsíci +1

    ❤ wow sir thanks

  • @gauravkumarbobde8987
    @gauravkumarbobde8987 Před rokem +1

    Great.. Sir

  • @ak-lr5jc
    @ak-lr5jc Před rokem +1

    Assalam O AllikUm Tanveer Sahib...we are building a 5 floor hospital with cooling load of approximately 500000 cfm for the whole building (average of 100,000 cfm per floor) We r having 4 chillers (3 functional + 1 standby) with a cooling load of 700 TR per chiller. We have 5 VFD based condensed water chillers each with a capacity of 1700 GPM at 185 feet head and 5 VFD based chilled water pumps with a capacity of 2100 gpm at 125 feet head. We have 2 cooling towers with 4 cells and 4000 gpm for each cooling tower. Moreover, we planning to make 2 out of 5 floors operational at this time only and energizing 1 chiller at this time.
    My question is that for only energizing 1 chiller (700 TR) only, will it be sufficient for cooling 2 out of 5 floors and if yes, gthen how many VFD based HVAC pumps (out of 5 each for chilled and condensed water pump) be required to run for this partial energization? Regards

  • @BebaMusic-bs2uy
    @BebaMusic-bs2uy Před 7 měsíci +1

    Tanweer Sab you excellent explain , Now i Become HVAC Engineer. hahaha

  • @arshorts9868
    @arshorts9868 Před 2 lety +1

    Sir aaj kal Troubleshooting questions zyda pochaa jata h toh aap iss pe video bnaye naa....
    Mohammad Aqif Rizwan from India🇮🇳

  • @indiantraveller194
    @indiantraveller194 Před rokem +1

    Mashaallah

  • @mddanishiqbal9719
    @mddanishiqbal9719 Před rokem +1

    Very good

  • @user-dz1dv1hc3z
    @user-dz1dv1hc3z Před 10 měsíci +1

    Asslm alkm...tanveer saab....how to make budgeting and estimation of project

  • @skshahbaz1969
    @skshahbaz1969 Před 2 lety +1

    Thank you so much sir

  • @NirajKumar-mm3zz
    @NirajKumar-mm3zz Před 9 měsíci +1

    Sir, HVAC ka wire connection ka bare main bhi video bnaye

    • @TanweerAhmed
      @TanweerAhmed  Před 9 měsíci

      What do you want to know about wire connections ⁉️

  • @mdgufrankhan4785
    @mdgufrankhan4785 Před 2 lety +1

    Good 👍

  • @Anil-Veeramangalam
    @Anil-Veeramangalam Před 2 lety +1

    Thank you sir...

  • @hardikjoshi7224
    @hardikjoshi7224 Před rokem +1

    Chiller ka purging system pe video banaye?

  • @bimstrategy7560
    @bimstrategy7560 Před 2 lety +1

    Thanks

  • @henryhawk7625
    @henryhawk7625 Před 2 lety +1

    Nice Video!
    I have a query? Why are control valves(3-way or 2-way) on the return side?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +2

      They are normally installed on return because of the following reasons:
      1. ASHRAE Recommendations.
      2. The coil of the unit should be flooded in case the valve is closed.
      3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment.
      4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.

    • @henryhawk7625
      @henryhawk7625 Před 2 lety +1

      @@TanweerAhmed Thank you for such a detailed reply!

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Welcome

  • @shahbaznezami4291
    @shahbaznezami4291 Před rokem +1

    Assalamualaikum,,, taveer sir, mujhe yeh jankari lena hai Aapse ki, mujhe HVAC field me career bnana hai to kiya mujhe AutoCAD janna zaruri hai, kiyoki mai Mechanical engineer hu, lekin mujhe autocad nahi Aata hai, to kiya mai pahile AutoCAD sikh lu uske baad HVAC-MEP kr ke job, please reply me

  • @AmirAli-li2ly
    @AmirAli-li2ly Před 2 lety +1

    Zabardast ada from Mehran eccentric reducer for air pocket missing

  • @gramathara4907
    @gramathara4907 Před 2 měsíci +1

    But where is constand speed and variable speed needed? I mean which kind of building

  • @atif-aftab1atif330
    @atif-aftab1atif330 Před 2 lety +1

    Assalamualaikum sir please make a vedio on interview questions vedio in which we can interview the person having more than 5 years of experience

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      These videos will useful for junior as well as senior Engineers. Insha'Allah

  • @jimmyjohn4070
    @jimmyjohn4070 Před 2 lety +1

    👍

  • @zahidkalim8649
    @zahidkalim8649 Před 2 lety +1

    Hvac system mein chilled water line aur condenser water line mein kaun kaun se valve lage hote hain sequence mein ?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Watch my videos how to read HVAC drawing of chilled and condenser pipelines

  • @mohammedshowkatakbar8933

    assalamualikum. iam requesting to upload a video for Design of Hospital project.
    Regards.

  • @ShivPriyo
    @ShivPriyo Před 2 lety

    Thanks you sir 🥀

  • @mdsitarekhan575
    @mdsitarekhan575 Před 2 lety +1

    Sir hamko interview dena hai HVAC ke regarding to ap Aisa trick bataye ki interview clear ho gayee

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      All tricks are useless without knowledge. First improve your skill knowledge, specially basics HVAC then mention points in your CV where your grip is strong. Mostly interviewers ask questions from your CV.

  • @safdarchuhan5705
    @safdarchuhan5705 Před rokem +1

    hvac legends or symbol in detail btayen plz

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      My videos are available on legends and symbols

  • @MDArif-gb9bi
    @MDArif-gb9bi Před 2 lety +1

    Why we used 2-way valve in return line of Ahu/Fcu
    Sir Can u describe this.

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +1

      DRV/2-way/3-way vales is used for control chilled water flow as per design requirements which is installed return pipeline.
      It is normally installed on return because of the following reasons:
      1. ASHRAE Recommendations.
      2. The coil of the unit should be flooded in case the valve is closed.
      3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment.
      4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.

    • @MDArif-gb9bi
      @MDArif-gb9bi Před 2 lety +1

      @@TanweerAhmed thank you sir.
      Plz upload next part

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Welcome... Insha'Allah soon will upload

  • @indiantraveller194
    @indiantraveller194 Před rokem +1

    Bhai jaan mughe bhi hvac ka channel banana hai category kaun sa select karein please bataiye 🙏😘👍🇮🇳

  • @aliasghar7420
    @aliasghar7420 Před 2 lety +1

    Fire pump ka flow test kaise karte hai pls bataiye

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Fire pump flow measure through flow meter installed in pump room. Some my videos are available and further will prepare

  • @sarabjitsingh3258
    @sarabjitsingh3258 Před 2 lety +1

    HVAC maintainance department mein vacancy batana.
    HVAC engineer or supervisor k level ki.
    ...bcoz I have iti in refrigeration and air conditioning and diploma in mechenical both i have done.

  • @SadiqKhan-qo5yg
    @SadiqKhan-qo5yg Před 2 lety +1

    Sir vrf py video banaye

  • @asemtantawy5779
    @asemtantawy5779 Před 2 lety +1

    Could you put translation in English and thank you sir for your efforts

  • @mustaquekhan945
    @mustaquekhan945 Před 2 lety +1

    The same question asked in my interview but he asked me like that why we used 3-way valve in FAHU instead of 2-way if 2 way we used it's also workable

  • @funtvwithamnaandhassan8674

    how we set the percentage in mixing valve

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      It is built-in in valves. Actually there are three types:
      1. On/Off valve as per temperature demand
      2. Proportional valve which automatically % open open or close as per demand i.e. may be 10%, 15%, 20%, 25%.....100%
      3. Percentage valve which open and close fixed %wise such like 0%, 50% & 100%

  • @jahirkhan8581
    @jahirkhan8581 Před 4 měsíci

    sir HVAC / MECHANICAL SUPERVISOR KE KOI VIDEO SHARE KARE

  • @MrShadab7
    @MrShadab7 Před 2 lety

    what is double regulating valve?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Watch my video on Double Regulating Valve

  • @Gulbarga_notebook
    @Gulbarga_notebook Před 2 lety +1

    You have not showed eccentric reducer in the suction line , this is most important to provide eccentric reducer

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +1

      Thanks for highlighting and sharing your positive response

    • @mohammedkirmanisyed7960
      @mohammedkirmanisyed7960 Před 2 lety

      In my interview also asked eccentric reducer on suction of pump and flat side to or bottom?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      There are different conditions. Insha'Allah will prepare video on this topic

  • @motivationalmsp9681
    @motivationalmsp9681 Před 2 lety +1

    HVAC vs MEP pe ek video banaye

  • @s.kranjan2731
    @s.kranjan2731 Před rokem +1

    Hi

  • @mathanraja43
    @mathanraja43 Před 3 měsíci +1

    Hello sir, please translate in English

  • @abdulkarim9807
    @abdulkarim9807 Před 2 lety

    Assalamualaikum sir

    • @abdulkarim9807
      @abdulkarim9807 Před 2 lety

      Sar compensation chain ka kya use Hota Hai

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      W.salam,
      Where is installed compensation chain?

  • @hardikjoshi7224
    @hardikjoshi7224 Před rokem

    Plasr

  • @rajinfotech4020
    @rajinfotech4020 Před rokem +1

    Tanweer Bhai aap APNA Whatsapp number send kar sakte hain...

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      You can ask here, I will must reply or joint my Telegram group "HVAC|MEP Engineering"