How to Install a Wall Mounted Space Heater | Ask This Old House

Sdílet
Vložit
  • čas přidán 13. 05. 2017
  • Ask This Old House master electrician Scott Caron warms up a chilly bathroom by installing an electric convection heater.
    Watch the full episode: www.thisoldhou...
    #ThisOldHouse #AskTOH
    SUBSCRIBE to This Old House: bit.ly/Subscrib...
    Time: 2 hours
    Cost: $150
    Skill Level: Moderate
    Tools List:
    Screwdriver
    Lineman’s pliers
    Wire strippers
    Drill
    Shopping List:
    Electric wall-mount panel heater
    14/2 non-metallic wiring
    Steps:
    1. Determine a source of constant power nearby to the desired installation location of the heater.
    2. Before doing any electrical work, ensure power is turned off at the breaker panel for the active circuits and confirm it’s off with a tester.
    3. If using an existing outlet as a power source, remove the cover plate with a screwdriver, then remove the outlet from the box. It may also be necessary to remove the box from the wall.
    4. Run 14/2 wiring from the existing outlet to the location of the new heater. It may be necessary to drill through wall studs or other structure.
    5. Remove the sheathing on the new wire at the existing outlet, then feed that wire through the electrical box.
    6. Strip the conductors on the new wire and either connect them to an available screw on the outlet or splice to existing conductors using wire nuts.
    7. Resecure the electrical box in the wall, replace the outlet, and install the cover plate.
    8. Strip the other end of the new wire and splice the conductors from the power supply to the appropriate wires in the heater.
    9. Install the supplied mounting brackets to the wall, then click the heater onto those brackets.
    10. Restore power to the circuit and turn on the heater.
    About This Old House TV:
    This Old House is the No. 1 multimedia home enthusiast brand, offering trusted information and expert advice through award-winning television, a highly regarded magazine, and an information-driven website. This Old House and Ask This Old House are produced by This Old House Ventures, LLC and are presented on PBS by WGBH Boston.
    Follow This Old House and Ask This Old House:
    Facebook: bit.ly/ThisOldH...
    Twitter: bit.ly/ThisOldH...
    bit.ly/AskTOHTw...
    Pinterest: bit.ly/ThisOldH...
    Instagram: bit.ly/ThisOldH...
    Tumblr: bit.ly/ThisOldH...
    How to Install a Wall Mounted Space Heater | Ask This Old House
    / thisoldhouse

Komentáře • 277

  • @foxfiresidechats5227
    @foxfiresidechats5227 Před 4 lety +12

    Scott is the best, even upgrading the outlet to a new tamper resistant!

    • @jackpast
      @jackpast Před 3 lety

      Yes, good move. I hate them personally...but if I had small children think I’d feel differently.

    • @Vanilla_Icecream1231
      @Vanilla_Icecream1231 Před 2 lety

      @@jackpast lmao whats wrong with tr plugs

    • @daidegoat
      @daidegoat Před 4 měsíci

      The best? Really? The heater should be on a dedicated circuit.

  • @Reefdevil
    @Reefdevil Před 7 lety +8

    Love the exposed receptacle box @ 0:32 next to the children's play area. "But were more worried about being cold!"

  • @aurvaroy6670
    @aurvaroy6670 Před 3 lety +4

    5:42 is my favorite part of this video

  • @tjbrower
    @tjbrower Před 6 lety +9

    I feel like these guys never run into the issues normal people do when trying to accomplish things like this lol They always have an easy access!

    • @CurmudgeonExtraordinaire
      @CurmudgeonExtraordinaire Před 6 lety +1

      Yeah, let's give them a house were they have to install it on an exterior wall where the walls are 8 ft tall and the ceiling is 10 ft tall and the wall has firebreaks in it. You can't crawl down to the header of the wall since the roof is there and even if you could, there's not enough room to run an extended length drill bit to drill a hole in the firebreak.

  • @TheHeadlessHorseman
    @TheHeadlessHorseman Před 6 lety +32

    4:20 I wished copyright free music would automatically start playing when I fixed things.

  • @buzoff4642
    @buzoff4642 Před 6 lety +9

    Love the FLIR on the cell phone. Good for finding air leaks in the winter.

  • @Aldohdezo
    @Aldohdezo Před 6 lety +6

    I don’t know why I love to watch these videos I don’t even do any handy work

  • @Yellow.Dog.
    @Yellow.Dog. Před 7 lety +107

    Not sure why I even watch the videos. All the expert advice is in the comment section. Ha!

    • @Joseph1NJ
      @Joseph1NJ Před 7 lety +1

      It always is...

    • @graceshiflett6526
      @graceshiflett6526 Před 7 lety +4

      "expert" advice

    • @jfmc2581
      @jfmc2581 Před 4 lety +2

      That's pretty much always true with this guy!!
      Hell most the electricians that come to defend seem retarded.
      I guess to get a license as an electrician the exam has a minimum number of questions you have to get wrong to pass!!

    • @Yellow.Dog.
      @Yellow.Dog. Před 4 lety

      @@jfmc2581 I'm having a hard time believing any trade worker would work their 8 hours then head to the youtube to comment on trade work. "In my 110 years of being a plumber...." I'm calling bullshit!

    • @leonardholt5311
      @leonardholt5311 Před 4 lety +1

      Jf Mc wa wa wahhh

  • @teravolt1195
    @teravolt1195 Před 7 lety +32

    0:56 Oh how convenient, it turns out he's an electrician.

    • @Syndiball123
      @Syndiball123 Před 7 lety +3

      Yeah they have a guy named Tom who is a wood worker a guy named Roger is a landscaper

    • @Marcel_Germann
      @Marcel_Germann Před 6 lety +4

      You forgot Richard, the plumber...

    • @StanSwan
      @StanSwan Před 4 lety

      As an electrician I am not too sure what this guy is. This entire set up is illegal.

  • @daddydoc1115
    @daddydoc1115 Před 6 lety +44

    Bollywood Vin Diesel is pretty good with wires

    • @lenovovo
      @lenovovo Před 6 lety

      That guy Scott Caron is a very handsome chap, most handsome indeed!

  • @HappyfoxBiz
    @HappyfoxBiz Před 7 lety +5

    This old house might want to look into replacing bathroom fans with one that is turned on with humidity, it would be very economical and reduce mould and mildew in bathrooms as many new style bathrooms have the light switch and fan connected or they are like the old style homes where they are seperate, the retro fitted ones are usually ran with a switch that's sometimes in unusual places.
    How the fan works is that it detects the moisture in the air and turns on automatically, once the moisture is down to a certain level, it turns off. making it ecenomical and quite safe

    • @cup_and_cone
      @cup_and_cone Před 7 lety

      These are good in theory, but a lot of homeowners use the exhaust fan when they use the toilet (even if they're not taking a 💩). A humidity switch is a hassle to the homeowner where one fan serves dual purpose. A standard timer is still a better option, IMO, for this application. The humidity sensor is a good idea if the bathroom has two fans on separate circuits (one for toilet, one for shower).

  • @ytrbro1041
    @ytrbro1041 Před 6 lety +2

    very cool device! low profile, hard wired, space saver and set temperature.

    • @JD987abc
      @JD987abc Před 3 lety

      He could have also installed an electric wall hung towel warmer/heater.

  • @lordsaagar2615
    @lordsaagar2615 Před 7 lety +12

    Did anyone notice the outlet with the missing cover at 0:32 I also think it was pointless to replace only the one outlet with a tamper resistant one as she still has to use the plug covers in the rest of them

    • @851995STARGATE
      @851995STARGATE Před 6 lety +9

      It's not pointless he was only there to install the heater not child proof all the outlets in the basement

  • @PhilipPetrunak
    @PhilipPetrunak Před 7 lety +19

    It would be a good idea to replace that outlet with a GFCI outlet. That way if any water fall in the heater there is no risk of anyone being electrocuted.

    • @Cris5598
      @Cris5598 Před 6 lety +10

      Especially me coming at 2 am from the bar and pissing in that white thing ....

    • @flexiblestrategist9922
      @flexiblestrategist9922 Před 4 lety +3

      I didn't think he would tap into another outlet. What is that outlet gets overloaded and trips the beaker with the heater on? I would have run a dedicated 12/2 directly to the panel box . I know the homeowner didn't want sheetrock being opened up in her finished basement but anytime a heat device is installed, supposed to have it's won 12 gauge wire directly to the panel box.

    • @stephensnell1379
      @stephensnell1379 Před 3 lety +1

      You mean breaker

    • @fizwin1
      @fizwin1 Před 3 lety

      @@flexiblestrategist9922 those heaters draw approx 3 amps....

    • @slappadabass3290
      @slappadabass3290 Před 2 lety

      @@fizwin1 Just commented the same thing until I saw yours. If it was 12 amps then yeah run a dedicated line, but 3 amps is no biggie

  • @deanalmeida7490
    @deanalmeida7490 Před rokem

    Can u enclose the make and model on the heater

  • @bamafan1612
    @bamafan1612 Před 9 měsíci

    What heater is this? I like that it’s wall mounted but also hardwired with a thermostat.

  • @janebishop5885
    @janebishop5885 Před 2 lety +1

    Ok....that bath was next to rooms that are heated so will naturally get enough heat to keep lines from freezing. Therefore, a small electric heater with a plug-in is fine for bathing....no calling in an expensive electrician or buying a pricey product.

  • @MarvelDcImage
    @MarvelDcImage Před 6 lety +2

    I have a basement full bath and built the room over the big return pipe for the steam radiators. Enclosed the radiator pipes in drywall box with vents tand that heats the bathroom fine.

  • @dwoodog
    @dwoodog Před 3 lety +3

    If the heater draws about 1300 watts it'll be using somewhere around 10-11 amps. Doesn't leave much left for any other devices.

    • @MattSezer
      @MattSezer Před 3 lety +2

      It doesn't. It's only about 500 watts.

    • @brinkjg
      @brinkjg Před 2 lety +2

      I wish he would have at least mentioned checking the breaker size beforehand.

  • @nestorcalderon9810
    @nestorcalderon9810 Před 7 lety +6

    No mention of the circuit capacity. Adding a space heater like that one, should not be that close to the toilet. The convenience of the outlet on the other side of the wall is great, but what if that particular circuit is already 80 % loaded?

    • @compactcow
      @compactcow Před 4 lety

      Can't wait for her to plug a vacuum into that outlet while the heater is running.

    • @Ariel1S
      @Ariel1S Před 2 lety

      It's probably a 500W heater, it's not full power.

    • @oldtwinsna8347
      @oldtwinsna8347 Před rokem

      It's a 3 amp heater. Even with a 12 amp vacuum being used in the other room outlet, it will not trip.

  • @CurmudgeonExtraordinaire
    @CurmudgeonExtraordinaire Před 6 lety +7

    I remember when houses were plumbed with natural gas lines into the walls in the bathrooms and there were gas powered space heaters mounted into the walls. When the electricity went out, we still had heat.

  • @Johngauthier740
    @Johngauthier740 Před 4 lety +3

    Nice way to start a fire adding a space heater to a existing circuit should have been a seperate dedicated circuit

    • @dlamarsobotor4573
      @dlamarsobotor4573 Před 4 lety +2

      Tend to agree but without knowing the possible total current draw it's in not 100 %

    • @Nick-bh1fy
      @Nick-bh1fy Před 4 lety +2

      John Gauthier should be dedicated yes, but assuming there’s little current draw on those outlets you should be fine. If anything a breaker will just trip

    • @fizwin1
      @fizwin1 Před 3 lety

      omg relax, those heaters are 3-4 amps and most come with a 3 prong plug

    • @electricaf365
      @electricaf365 Před 3 lety

      That won’t start a fire you bozo

  • @user-to2qk9oz6b
    @user-to2qk9oz6b Před 6 lety +1

    Lol only problem in winter would be breaker kicking off as circuit had 10 more plugs on it...🤣🤣

  • @ggillesp1
    @ggillesp1 Před rokem

    What brand is this heater?

  • @vince6829
    @vince6829 Před rokem

    Nice job. Thank you for sharing.

  • @victorlee7638
    @victorlee7638 Před 3 lety

    Point of isolation should be provided for the heater.

  • @VolpeInCalze
    @VolpeInCalze Před 7 lety +24

    no gfci required for the heater next to the toilet?

  • @stevecraft00
    @stevecraft00 Před 3 lety

    Does american code not require local isolation of appliances? In the uk we would have an isolator for that just outside the bathroom.

  • @HowardSantiago-qn4kv
    @HowardSantiago-qn4kv Před 7 lety +3

    it's not complete until he says "im going to MAAAAAK IT"

  • @zztop8592
    @zztop8592 Před 6 měsíci

    Natural gas heater is less expesive to run.

  • @luisa6366
    @luisa6366 Před 6 lety +2

    What was done to cover up the hole in the wall where the cable was fed to the wall heater? Was there a recessed wall plate used or a feed-through bushing? Was it caulked?

    • @AgentOffice
      @AgentOffice Před 4 lety +4

      Probably nothing, it's just drywall

    • @encendido27
      @encendido27 Před 3 lety +7

      The unit covered the hole.

    • @oldtwinsna8347
      @oldtwinsna8347 Před rokem

      Nothing needed. It is drywall and an interior wall so no issue with insulation.

  • @GreenMountainDIYGuy
    @GreenMountainDIYGuy Před 7 lety +4

    Anyone know the make and model number of this convection heater?

    • @lexluther8370
      @lexluther8370 Před 7 lety

      1:05 "it's a wall mounted panel heater", pause at 1:15 - It's an Envi - google

    • @GreenMountainDIYGuy
      @GreenMountainDIYGuy Před 7 lety +2

      Yep, just saw that. www.eheat.com/envi-high-efficiency-whole-room-plug-in-electric-panel-heater-hh1012t/

    • @nickv4073
      @nickv4073 Před 7 lety

      Looks like an "Econoheat" panel. They have a website.

  • @johnal4560
    @johnal4560 Před 2 lety

    Hi don't you need a separate or dedicated breaker for that i need to install some in my house so if i connect it to any out let is that gonna be ok some one said that you not have to use that outlet for anything else thx

    • @oldtwinsna8347
      @oldtwinsna8347 Před rokem

      This draws 3 amps, it's meant to be operational 24x7 so it doesn't blast heat out like a regular portable 12 amp for spot treatment. 3 amps is below threshold needed for a dedicated line.

  • @HJCF0520
    @HJCF0520 Před 7 lety +3

    Excellent video! I wonder if it has a disconnect switch built in or if it's just controlled by the thermostat. It looks like a great product.

  • @CharlesReiche
    @CharlesReiche Před 7 lety +11

    No bath or shower, Room is between 2 other rooms. Do they really need heat? I have no heat in my farmhouse bathroom. Taking a shower in the winter? Work quickly.

    • @onecrazywheel
      @onecrazywheel Před 6 lety

      I thought what if a kid dumps a cup of water into the top of the heater in there?!

    • @nhcharmedone
      @nhcharmedone Před 6 lety +1

      Here we go again, just because YOU don't have or want heat in a bathroom, doesn't mean others should have to be cold! You do whatever makes you happy and leave others alone!

    • @jasonmorehouse3756
      @jasonmorehouse3756 Před 6 lety

      he will learn his lesson and probably only do it the once

  • @jeffarnold1983
    @jeffarnold1983 Před 3 lety +1

    I know this is an old video, but how many watts is that heater?

    • @outlander4002
      @outlander4002 Před 3 lety

      It looks like an ENVI HEATER and it's 500 watts

  • @jmsalvador3245
    @jmsalvador3245 Před 2 lety

    Where did he buy the heater?

  • @alexcorales6193
    @alexcorales6193 Před 6 lety +1

    I like this new Vin Diesel

  • @ryans413
    @ryans413 Před 10 měsíci

    How much current do these heaters draw. Can you piggyback off a wall outlet or do they have to be on there own breaker.

    • @KyleDisantoMASTERING
      @KyleDisantoMASTERING Před 8 měsíci +1

      Looks like a 500 watt model. I could be wrong. The brand is called EnviHeat

  • @hiddenman99
    @hiddenman99 Před 8 měsíci

    Seems like a bathroom heater Should be on a circuit by itself.

  • @davidmerlino2193
    @davidmerlino2193 Před 2 lety

    Cool show

  • @Kirby7601
    @Kirby7601 Před 6 lety

    Does this only work on bathrooms?

  • @bobsjers
    @bobsjers Před 6 lety +1

    How much does the heater draw that the electrician can just tap off of a circuit without looking to see how much is already on the circuit?

  • @gregorall9779
    @gregorall9779 Před 3 lety

    I would assume that the load on the heater is quite low as he is attaching it to an existing circuit?

    • @daleplumley9672
      @daleplumley9672 Před 3 lety

      The Envi Heater seen here is 500 Watts. At 115 Volts this heater will draw 4.35 Amps.

  • @marclebrun641
    @marclebrun641 Před 2 lety +1

    Would love to know how he got that outlet out of the wall with no damage considering they are nailed into the stud, just saying

    • @majorpayne5289
      @majorpayne5289 Před 2 lety

      He said box wasn’t nailed to 2x4. I find it crazy that someone would build a room without considering HVAC. Also, installing an inferior electric heater on “shared” wiring not considering AMPS or the overall load on existing 14-2 wiring. Definitely not the way I would install!! Needs dedicated 120v circuit IMO.

    • @Heelstar22
      @Heelstar22 Před 2 lety +5

      He said it’s an old work box. That means it was added after framing and thus not nailed into the stud. Old work boxes are held in place with tabs that fold up behind the Sheetrock, no nails

    • @protoman247
      @protoman247 Před 2 lety +1

      He laterally said in the video that it was an old work box. It was added after the dry wall was put up. Old work boxes work by clamping onto the wall surface. If it was a new work box, you would simply use a reciprocating saw to cut the nails holding it to the stud.

  • @adnanbradaric4162
    @adnanbradaric4162 Před 2 lety

    Someone can explain how did he connect the new wire to the electrical outlet ?

    • @bnmartell
      @bnmartell Před 2 lety

      He actually connected against code. He use the second set of screws on the outlet and used the outlet as a splice point.

  • @willc32917
    @willc32917 Před 3 lety

    If you set the thermostat by turning it up high and then lower till you hear the click will it shut off and on by itself, conserving energy?

    • @Bendigo1
      @Bendigo1 Před 2 lety

      That is what a thermostat does... It will turn off the heater when the temperature is above the set temperature, then turn it on when it is below that set temperatusre.. That click, is the switch inside the thermostat turning on or off.

  • @fixitwithzim
    @fixitwithzim Před 7 lety +24

    I probably would have done a pigtail connection in the outlet box instead of wiring the heater through the outlet. Nice clean install otherwise.

    • @cup_and_cone
      @cup_and_cone Před 7 lety +2

      Can't think of any single benefit to this aside from potentially future proofing.

    • @TheRealTonyCastillo
      @TheRealTonyCastillo Před 7 lety

      I believe by code only the neutral is required to be pigtailed, although it is common practice to pigtail all the conductors in a box in case a receptacle fails in the future and killing power to any other things downstream which in this case would be the heater.

    • @cup_and_cone
      @cup_and_cone Před 7 lety +6

      Tony Castillo - That is for multibranch circuits, which isn't in 99% of homes. There is no code requiring pigtails, or duplex outlets wouldn't exist.

    • @TheRealTonyCastillo
      @TheRealTonyCastillo Před 7 lety

      zimsjeep Yeah the pig tail is for multi branch circuits as you mentioned, still good practice to pigtail I truly believe.

    • @fixitwithzim
      @fixitwithzim Před 7 lety +2

      Tony Castillo I never said anything was code. All I was saying was I would have pigtailed the connection rather then feed it through the outlet. No right or wrong way here. Just personal preference.

  • @brendancarlson1678
    @brendancarlson1678 Před 3 lety

    Did I miss the gfci part?

    • @daleplumley9672
      @daleplumley9672 Před 3 lety

      This is hard wired. It does not need to be on a GFCi circuit. If it plugged into an outlet in the bathroom, it would need to be a GFCI outlet or GFCI circuit breaker in the service panel, as GFCI protected outlets are required in bathrooms.

  • @nathanz1982
    @nathanz1982 Před 7 měsíci

    What about a GFCI?

    • @oldtwinsna8347
      @oldtwinsna8347 Před 6 měsíci

      Have to agree, can easily see a kid thinking it would be interesting to pour some water down those grills since it's mounted so low they can easily reach it.

  • @artmiranda8085
    @artmiranda8085 Před 6 lety

    I have a 16x15 room that has no heating at all and i need to make it a room temp. Has one door leading to the front, another door leading to the backyard and another to the garage. Also has windows and concrete floors. What heating solution would you recommend ? I was told to either go with DV wall heaters or one with hyper heat pump system. I'm from Chicago! Please help!

    • @tylernettestad
      @tylernettestad Před 6 lety

      Ductless heat pumps are awesome. Check out some of the Fujitsu models. They will heat a room even when the temps fall to -15 degrees F.

  • @backpacker2009
    @backpacker2009 Před 6 lety

    Can this same installation method be used to wire in a Stiebel Eltron
    CK 1500w wall heater? I would like to add this heater to my bathroom/hallway circuit via an outlet in the bathroom. This circuit has a few outlets and three single LED bulb lights on it. Any thoughts or ideas would be greatly appreciated! Thank you

    • @gregorall9779
      @gregorall9779 Před 3 lety +2

      I would suggest that you try to use a dedicated circuit due to the wattage of your heater. 1500 watts equals slightly more than 12 amps which is 60% of a 20 amp circuit or 80% of a 15 amp circuit. I don't know what your branch circuits are run in, so to be safe, install a 20 amp dedicated circuit if possible.

  • @zeframmangum3356
    @zeframmangum3356 Před 6 lety

    can you do how to install a swamp cooler

  • @stuntcardriver
    @stuntcardriver Před 7 lety +1

    wall heater doesn't need to be on a dedicated circuit?

    • @yaosio
      @yaosio Před 7 lety

      They were using an extension cord for the other heater, suggesting there wasn't a plug already in the bathroom.

    • @cup_and_cone
      @cup_and_cone Před 7 lety

      The Cat Man
      circuit ≠ outlet

    • @cup_and_cone
      @cup_and_cone Před 7 lety +3

      stuntcardriver - NEC says as long as it's under 50% circuit capacity it's acceptable, as long as manufacturer doesn't require it. The heater was 4 amp.

  • @stevenpersinger6577
    @stevenpersinger6577 Před 2 lety +1

    Why not gfi protect it. I definitely would being in a wet location with children. And why doesn't this man ever use a cordless to put stuff together

  • @marcodm
    @marcodm Před 6 lety

    240V is much better but chose this route not to make holes to panel. Just cant plug something amp heavy on plug circuit.

    • @dlamarsobotor4573
      @dlamarsobotor4573 Před 4 lety

      Without know all the parameters this is only a guesstimate.

    • @oldtwinsna8347
      @oldtwinsna8347 Před rokem

      There's no 240v line anywhere near that wall. And not needed for that single room size anyway.

  • @djamelazerty7549
    @djamelazerty7549 Před 7 lety

    very good job

  • @zekenzy6486
    @zekenzy6486 Před 7 lety

    nice work

  • @cobaltpica
    @cobaltpica Před 6 lety +1

    No shut off switch and RCD protection?

  • @davekauffman8727
    @davekauffman8727 Před 6 lety

    Wiring it is the easiest part, showering loads the air with moisture, which condenses on all surfaces in the bathroom, including the non-heated electrical parts of such an appliance. No real danger because if it does short the electricity will go to the ground-wire, but this is a bad spot for this heater.

  • @ncc74656m
    @ncc74656m Před 7 lety

    Could you tell me why he didn't tape off the wire nuts? Not necessary? Not recommended?

    • @Engineer9736
      @Engineer9736 Před 7 lety

      I never heard about taping wire nuts. Every country has a building code which describes how electrical (and other construction) work has to be carried out. No need to be creative, or better said, you absolutely should not deviate from the building code. Every little detail in there has a reason which comes from hundreds of years of construction experiences country-wide. If you are not an certified electrician, you should not do anything electrical, not because of you cannot do it, but because you don't want your insurance saying "You didn't get a certified electrician, so it's your problem that your house burned down".

    • @morlamweb
      @morlamweb Před 4 lety

      Taping the wire nuts is recommended only if there are exposed conductors below the wirenut. That shouldn't happen in most cases if you cut the correct amount of sheathing off the wires and uses the correct size wirenuts. Use silicone-filled wirenuts for added protection in outdoor boxes.

  • @mamanothing9506
    @mamanothing9506 Před 3 lety

    Gee would have liked to know the brand of this heater

    • @outlander4002
      @outlander4002 Před 3 lety +1

      500 watt ENVI HEATER

    • @evaeva1932
      @evaeva1932 Před rokem

      @@outlander4002 how much square footage room would you put this in? I have a 10 x 12 sun porch with lots of windows i can't use in the winter due to cold, even with a heat duct

  • @andreafelton689
    @andreafelton689 Před rokem

    4:22 he didn't say what he was doing next. Bad teacher

  • @davidredpath4781
    @davidredpath4781 Před 6 lety +5

    I would have used pigtails for the receptacle.

  • @panama-sx2oh
    @panama-sx2oh Před 4 lety

    how many amps does that heater put out

    • @brbrofsvl
      @brbrofsvl Před 3 lety +1

      The Envi ones seem to draw around 4 amps

  • @laurie6123
    @laurie6123 Před 3 lety

    How many square feet can one of those wall heaters heat?

  • @curiosity2314
    @curiosity2314 Před 7 lety +3

    Better solutions out there for this scenario.

  • @MSI2k
    @MSI2k Před 7 lety +49

    God bless electricians. Making holes in my walls and studs like friggen rats in a Russian ships.

    • @yaosio
      @yaosio Před 7 lety +60

      Electricians keep general contractors working by destroying floors and walls, general contractors keep electricians working by cutting through live wires. It's the circle of life.

    • @Joseph1NJ
      @Joseph1NJ Před 7 lety +19

      You forgot plumbers, even bigger holes, degrading structural integrity, and then leave a mess.

  • @flamingballzonice
    @flamingballzonice Před 7 lety

    what's that heat sensor cam scott attached to the iphone called?

    • @QuadroNVS
      @QuadroNVS Před 7 lety

      FLIR ONE Thermal Imager for iOS - You need the hardware (detachable camera) and the FliR app.

  • @joeacfalle2380
    @joeacfalle2380 Před 7 lety

    Whoa, how did you set the outlet to work with plugs and not a paper clip and no more plug covers? This is an interesting video to make.

    • @TrafficControlFreak
      @TrafficControlFreak Před 7 lety

      it's just a different outlet..

    • @lexluther8370
      @lexluther8370 Před 7 lety

      google - tamper resistant outlets

    • @JaredBartimus
      @JaredBartimus Před 7 lety +2

      Something has to be pushing against both hot and neutral for the built in shield to open up. So you need to be dedicated enough to zapping yourself that you would remove a normal cover anyway.

    • @jgroenveld1268
      @jgroenveld1268 Před 7 lety

      Yeah the UK system uses a shutter system where the earth/ground prong must be inserted to open the neutral and live/hot ports. The US version I seen is a type of cover that covers the entire outlet and you use the plug to "shift" the cover to access the hole.

  • @wefixit5906
    @wefixit5906 Před 7 lety +1

    i'm pretty sure there is a violation with pigtail because we shall not use device as a pigtail.

  • @andreafelton689
    @andreafelton689 Před rokem

    The music is inappropriate

  • @matthewnowak3488
    @matthewnowak3488 Před 2 lety

    Did anyone notice that he didn’t use a pigtail to wire the outlet back up, it looks like he used the receptacle as the splice point, that’s bad practice.

    • @jamesthew800
      @jamesthew800 Před 2 lety

      Strange how in the US you pigtail connections and in the UK that would be concerned bad practice as we minimise wire joints as much as possible (less possible points of failure)

  • @snowingli8747
    @snowingli8747 Před 6 lety

    can you do a video report for our new heater ?

  • @QuadroNVS
    @QuadroNVS Před 7 lety +3

    I no expert but isn't that against code to put an electric source/object that close to a source of water unless its GFCI certified ?

  • @saulgoodman2018
    @saulgoodman2018 Před 7 lety +2

    Wouldn't it be better to wire it to the bathroom light switch?
    So when put put on the light it goes on.

    • @oldtwinsna8347
      @oldtwinsna8347 Před rokem

      You'd need like a 5000 watt equivalent blast forced air heater to do what you are suggesting, as the instantaneous heat output is never going to happen with a tiny heater.

    • @saulgoodman2018
      @saulgoodman2018 Před rokem

      @@oldtwinsna8347 No you don't. He essentially did the same thing, on a different circuit.

  • @Burps___
    @Burps___ Před 7 lety +23

    Too close to toilet, uncomfortably warm for newspaper readers.

    • @xraydelta100
      @xraydelta100 Před 7 lety +8

      Absolutely too close.....Reading the newspaper and suddenly you have a flaming paper in your lap and shorts.

    • @stephensnell1379
      @stephensnell1379 Před 3 lety

      No idiot would od that whilst on the toilet

    • @MD-wq6on
      @MD-wq6on Před 3 lety

      At least the toilet seat would be warm.

  • @pedrosilverio5255
    @pedrosilverio5255 Před 6 lety

    the heat is badly connected because if the outlet is damaged the heat will stop working

  • @vegasfordguy
    @vegasfordguy Před rokem +1

    TOH should have kept Scott on the show. I think they made a bad decision when they let him go.

  • @jareds7969
    @jareds7969 Před 7 lety +9

    Nice. Should have ran a new circuit. It takes 4 amps/475 watts at 120v and that was only a 15 amp circuit. That's not counting the other loads on that circuit. They will be tripping the breaker every so often.

    • @cup_and_cone
      @cup_and_cone Před 7 lety +2

      Lot of high power vacuums go right up to UL 12-amp limit...most are 8+ these days. Add something like a desktop computer or plasma TV already on circuit, breaker trip.

    • @jareds7969
      @jareds7969 Před 7 lety

      Yeah. Our vacuums are 12 amps.
      Are there permits required to install something like this?

    • @Joseph1NJ
      @Joseph1NJ Před 7 lety +1

      Plasma in 2017? I thought they don't last that long.

    • @cup_and_cone
      @cup_and_cone Před 7 lety +3

      Joseph1NJ - Most plasma TV's were sold with 50,000+ hour lifespan. That's almost six years of continuous usage. We have a 50" LG plasma going on 7 or 8 years now, runs at least 12 hours a day and only thing that's ever needed changed was the power supply control board last year. Plasma TV's fell out of favor because they take a lot more electricity over LCD/LED TV's (in some cases three or four times more), they also are much heavier/cumbersome, and were far more expensive to manufacture and couldn't be economized.

    • @Joseph1NJ
      @Joseph1NJ Před 7 lety

      I didn't know that. Some friends were early buyers, and their's died in about 5 years or so.

  • @Community-Action
    @Community-Action Před 6 lety

    Don’t miss when you piss or you’ll get a zap!!

    • @MD-wq6on
      @MD-wq6on Před 3 lety

      Have you tried this before?

  • @erianaplantagenet6610
    @erianaplantagenet6610 Před 4 lety

    Link to heater www.eheat.com/envi-high-efficiency-whole-room-120v-hardwired-electric-panel-wall-heater-2nd-generation-hw3012t/

  • @DordiHOTS
    @DordiHOTS Před 6 lety

    i like scott

  • @Ariel1S
    @Ariel1S Před 2 lety

    Ugh, never install that kind of thing near a toilet. Splash from the toilet will corrode it and it will fail within a few years.

    • @jamesreynolds5776
      @jamesreynolds5776 Před rokem

      Close the lid if flushing lol 😆

    • @Ariel1S
      @Ariel1S Před rokem

      @@jamesreynolds5776 The corrosion happens from spashback while going to the bathroom, not while flushing.

  • @gordonalexander1639
    @gordonalexander1639 Před 6 lety +1

    Where’s the RCD?

  • @andyzamboknee
    @andyzamboknee Před 6 lety

    brand? Is that an eheat Envi?

  • @johnbaptist7476
    @johnbaptist7476 Před 2 lety +1

    ∞ ❤ ly work . I realy enjoy to watch U , when U explain how to fix the problem . I think it is your charisma .📡 ✟✡✟❤ U .

  • @HalfBlocked
    @HalfBlocked Před 6 lety

    That window in the background is crooked AF

  • @jfmc2581
    @jfmc2581 Před 4 lety +1

    Dosen't this require a dedicated circuit to be up to code?

    • @kylefowler5082
      @kylefowler5082 Před 4 lety +1

      while I couldn't find the exact unit installed in the video, based on the size of the wires of the heater and by similar units online with specifications I believe the heater installed is around 400-500 watts which is around 4.2 amps max. The circuit he tapped into is a 15 amp circuit (only rated for 12 continuous amps however).
      Overall its OK, definitely the cheapest option they have since it seems they can't run a dedicated circuit without drywall damage. As long as they don't use a vacuum cleaner when the heater is on they won't trip a breaker LOL
      This video is a good example of why it's not a great idea to put in hard ceilings in a basement of an older house that hasn't been modernized throughout. You end up with these compromises over and over. A better option would have been a ceiling grid with nice ceiling tiles in the basement if a whole house remodel wasn't in the budget.

    • @jfmc2581
      @jfmc2581 Před 4 lety

      @@kylefowler5082 , Yeah I just thought a permanent installation needs a dedicated circuit. I mean the unit is only 500 watts and permanent wiring should be a lot safer that a 1500 watt portable heater, but I thought a licensed electrician had to follow code and run a dedicated circuit. Is that not the case?

    • @kylefowler5082
      @kylefowler5082 Před 4 lety

      @@jfmc2581 permanent fixtures do not necessarily require dedicated circuits. Some do (like fridges and washing machines) and some dont. Not including code required dedicated circuits a good general rule is not to load a circuit more than 80% of its rating. Exceeding 80% can lead to nuisance tripping. For example if the heater pulled 12 amps and you were installing it on a 15 amp circuit it would need to be a dedicated circuit because that's 80% of the circuit's rating. But that 12 amp heater could share a 20 amp circuit with something else provided it doesn't pull more than 4 amps. (this circuit would have a total of 16 amps which is 80% of 20 amps)
      A common example of dedicated appliances sharing the same circuit is alot of houses are wired with the garbage disposal and dishwasher sharing a 20 amp circuit.
      Another example I've seen a few times is that a gas air handler and its code required service outlet share the same circuit. The air handler pulls just 5 amps usually so that leaves enough for the service outlet. I personally don't like it but it can be done.

    • @jfmc2581
      @jfmc2581 Před 4 lety

      @@kylefowler5082 , Really just asking about the NEC for this. Is it considered an appliance? Do you know what section allows for this? Also when a licensed electrician does the work does it have to be 100% to code all the time?

    • @kylefowler5082
      @kylefowler5082 Před 4 lety +1

      @@jfmc2581 in the NEC the only required dedicated appliance circuits in a home are for the fridge, microwave, and washing machine that I can recall off of the top of my head. Stoves and dryers can be gas or electric powered meaning they will or will not have dedicated circuits depending on that.
      Other than that the NEC doesn't specify that a hardwired appliance have a dedicated circuit. Let's say you were only using electric wall mounted heaters to heat your home. If you ran a dedicated circuit for each one you could end up filling up a whole panel with dedicated circuits for no reason if several heaters could be on one circuit. It would be an unnecessary waste of time and money. When baseboard heaters were common in houses they typically shared a circuit when that was possible.
      And yes electricians must follow the NEC code all the time, no exceptions

  • @SR-hl5vz
    @SR-hl5vz Před 6 lety +7

    RIP electric bill : (

  • @matthewwong1064
    @matthewwong1064 Před 4 lety

    I though he said level with the toilet. What happened?

  • @jrnull1
    @jrnull1 Před 7 lety +4

    And "No Mention" of how MOST heating circuits need to be separated from other circuits to pass code...

  • @farrell2k
    @farrell2k Před 6 lety +6

    Bad. Always install heat on a dedicated circuit. Now that socket is basically unusable when the heater is running.

    • @twngrl1625
      @twngrl1625 Před 6 lety

      Thats true

    • @MrWHITTERS8
      @MrWHITTERS8 Před 6 lety +1

      How is that socket outlet unusable when the heater is running? They'll still be power at the outlet, the heater is only spured off of it whilst you can still plug into the three pin plug.

    • @farrell2k
      @farrell2k Před 6 lety

      MrWHITTERS8 - that heater is 120v,, likely 1k watts or 1.5k watts. Good luck plugging anything other than an electric shaver in there while the heater is running.

    • @squamnh
      @squamnh Před 6 lety +2

      475 Watts

    • @fnhwk
      @fnhwk Před 6 lety

      You do have a valid point but I disagree with you. That heater most likely draws under 10 amps. Assuming it's a 15 amp circuit I am going to take a wild guess they dont plug in anything in their touchscreen room that would draw more than a couple amps. Chances are the heater is only going to run a few times a year.

  • @bobandbobandbob6285
    @bobandbobandbob6285 Před 4 lety +1

    "New plugs."
    Meanwhile Britain has had that feature since 1946 and it's been a requirement since then

  • @johans7119
    @johans7119 Před 3 lety

    Great for wet towels and the kid's cups of water...

  • @peteo4454
    @peteo4454 Před 7 lety

    what brand is that?

    • @lexluther8370
      @lexluther8370 Před 7 lety

      1:05 "it's a wall mounted panel heater", pause at 1:15 - It's an Envi - google

    • @peteo4454
      @peteo4454 Před 7 lety

      Lex Luther thanks i couldn't read that on phone

    • @lexluther8370
      @lexluther8370 Před 7 lety

      + Pete O - took me more than once, and I was using a full screen. I was going to send a link, but I didn't know where you live and what stores are available to you.

  • @brettvukovich6220
    @brettvukovich6220 Před 3 lety

    She has the personality of a brick wall.

  • @StanSwan
    @StanSwan Před 4 lety +5

    Do I even need to go though all the NEC codes that make this illegal? Amazing you do not have an expert check out what is guy is doing.

  • @Lcab-bh3wx
    @Lcab-bh3wx Před 3 lety

    Why not a pig tail.

  • @iheggis86
    @iheggis86 Před 6 lety

    American toilet rolls are wide! 😳