Nitrox 6kw Parallel connection | Nitrox 6kw k parallel kray ALB electric solar energy
Vložit
- čas přidán 7. 09. 2024
- inverex nitrox 6kwnitrox 6kwnitroxinverex nitrox 6kw smart load settingnitrox 6kw hybrid inverternitrox inverex nitrox 6kwnitrox 6kwnitroxinverex nitrox 6kw smart load settingnitrox 6kw hybrid inverternitrox parallelinverex nitrox 6kw hybrid solar inverter6kw solar system installationinverex nitrox parallel operationnitrox hybrid parallelinverex nitrox parallel,inverex nitrox 6kw complete installationnitrox parallel programing
Assalam walekum sir aapki video dekhkar Kafi kuchh sikhane ko Mila
Thanks watch my video
سچ پوری ایمانداری کے ساتھ
❤
Parallel karany steps bataie
Connection pehlay kartay hy ya programming pehlay lazmee Kar k connection karnay hutay hy
Good information ⚡🛠️🌅
Very informative bhai
💯 original one video and other also
Informative ❤
Smart load sahi work kar rha hai? Or aap nei dono inverter mei CT lagae hai inverter setting "zero export to load" hai ya "zero export to CT" ya "selling first"
G bhai good working kr rha Zero export to load
sir keya phir ghar main ek invter ki in wire deni ya 2no ki common karni hoti
Common
Aoa bhi wapda se single tar leni ha agar 3phese meters ha to 2phese use kar sakte ha ya meters single phese 2 ho to?
Assalam o Alaikum Bhai g Agr 1 inverter Bettry wala ho
Or 1 with out bettry ho to 2no parallel ho jaye gain
13A say 14A aik string ka current hota hai. Us pr 16A ka DC breaker lgta hai. Ya max 20A ka. Ap nay 63A k lga diay hain. Isi liay fault ki soorat main breaker trip nahi krtay. Ainda is point ko bhi yaad rakhain. Magnetic flux cancel kr k liay jo rings inverter k sath atay hain wo bhi ap nay nahi lagaye
Aj kal invertr k sath 8 megnt ring ata hai. ?? Can u explain
13 ya 14 A to hota ha apne sai bola.Panel ki lament 13 14 A hi hoti ha agr short circuit ho to yahi current hamen mile ga. Wapda mein hamari generation jyada hoti hai mtlb Megawatt Tu shar circuit per current 300% brh jata hai. Solar per aisa Nahin hota. Solar mein hamen safety chahie majbuti chahie 20A heat up ho jaega 20A ka lga lo ya 63A ka ya trip Nahin honge. Maksad ji hota hai ki hit up hokar aag na Lage.
سنگل فیز پر 12 کلواٹ لوڈ؟
Bhai nytrox 6kv k sath 585 k 9 panels series main lga dain tu koi masla tu ni
@@masoodmobiletricks3132
No isho
Can we use this inverter with sharing electric company with out battery use in day time?????
Yes
@@muhammedshahbaz-zuhan THANKS FOR REPLY,...MY SOLER PLATES 12 -580watts.i want to use this inverter with out battery
Day time with out battery.....i mean can i use this with sharing with kE.as i m in karachi...please.
bhai bahawalpur aty hn ap??
@@danibabaofficial8578
Kam ho to
سلام ۔۔۔
Invrex 6000 ki wifi kise kre gy..
Apps n sating bata do plzzzzz..
Kia ek Nitrox 8kw or ek Nitrox 6kw apas main Parralel ho sakte hain??
@@user-bp2zg2jx2l
No possible
@@muhammedshahbaz-zuhan 8kw k sath 8kw hi parallel hoga?
@@user-bp2zg2jx2l
G bhai
@@muhammedshahbaz-zuhan Mehrbani
@@muhammedshahbaz-zuhan agr 2 8KW inverters ko Parallel kar dein to wo 4 tubular battreis k sath chal jaeingy ya 8 batteries lagani pareingi??
کیا دونوں انورٹر کو الگ الگ پینلز دینے پڑتے ہیں؟ اور نیٹ میٹرنگ میں کیا دونوں انورٹر گرڈ کو سپلائی دیتے ہیں؟ اور بیٹری صرف ایک انورٹر کے ساتھ لگے گی؟ پلیز رہنمائی فرمائیں۔
Ji Bhai donon inverter ko alag alag panel lagte Hain aur donon inverter jo hai parallel hote hain donon gridfiding karenge batteries jo hai donon ko attach ho gi
@@muhammedshahbaz-zuhan
Can we use dual output features of parallel inverters
Sir number dedy please @@muhammedshahbaz-zuhan
Kya 8 kilowatt aur 6 kilowatt ko parallel Laga sakte hain
Not possible
اسلام علیکم بھائی جان
یہ انورٹر PV سے پاور پوری ہونے پر گرڈ کو 0 ظاہر کرتا ہے
لیکن اس کے باوجود 3amp تک لا لوڈ گرد سے کنزیوم کرتا ہے
اس کی کیا وجہ ہے؟ ؟؟
جزاک اللہ خیر
capacitor current K amper ha
Ser apka number chahiye
03093863630
Aoa bhai kia ap rahim yar khan sy hn tu plz send me ur contact number
03026034771
03016034771