Paano Hanapin ang Common, Run, Start sa Compressor Motor
Vložit
- čas přidán 7. 09. 2024
- #Pinoytechnicianabroad #Pinoytechnician #Pinoytechnicianvlogger
Paano e determine ang Common, Run, Start sa Compressor Motor
Paano e Ohms ang resistance ng winding ng Compressor Motor
Paano ma check kung grounded ang Compressor Motor
Read ka ng highest resistance tapos yun wala sa test lead yun ang common. Yung natitira run or start na. Common na ang isang test lead kasi alam mona ang common eh. Common to another terminal kapag nag read ng mataas run yan. Yung mababa start yan. Steady lang isang test lead sa common.
Parang mali yata
Mali.. start to common ang may mas mataas na reading.. common to running mas mababa
Life is too short. Grudges are a waste of perfect happiness. Laugh when you can, apologize when you should and let go of what you can't change.
keep grinding miloves......
Highest resistance = start + running po yan. Second highest resistance start po yan. Lowest resistance running po yan. Eto ang pinaka magandang paliwanag. Kaya naging common ang highest resistance kasi yung gitna ang gawing common. Gitna ng start at run.
ayos kateck.. ag isa mong youtube kalecky.. d kna pala sa barko.. ingat ka teck/ ka lecky.. God bless
_alam mo ikaw ang ernie baron ko dami akong natututunan na new knowledge! see you in a bit!_
No matter how you feel GET UP dress up show up and never give up because GOD WILL LIFT YOU UP 🙏Sending love and support from our VERY OWN LEGIT TEAM MASAYAHIN
Lowest resistance is running terminal idol,
Nagkamali lng sya sa pagsulat sir.
Napakahusay mo tlga Sir. Salamat sa mga ideya na ibinabahagi mo samin, malaking tulong. God bless you more Sir🙏.
May napanuod dn Ako ung highest is common ung second is starting and last is running
Yan ang gama boss
Success isn't just about what you accomplish in your life, it's about what you inspire others to do. Stay safe and healthy.
Yung common lang idol ang opposite reading idol. Kasi add run at start yung gitna sa coil yun ang common. Yung run at start hindi na yung natitira common terminal to another yung reading non yun ang identify mo hindi yung natitira.
Success isn't just about what you accomplish in your life, it's about what you inspire others to do.
Salamat sa idea sir
Ohhhh ryt idol... all set na!
di ko talaga alam yan mamaya antayin ko to pra may new learnings ako ma dscover
thanks for sharing dami ko natutunan
GOOD LUCK Hossam TEEM..............GOOOOD
Wala kang idea Sir kung gaano ka nakakatulong sa mga katulad nming baguhan pa lamang. maraming salamat po.. pagpalain ka pang higit ng Diyos..
Pag dating sa ganito bro..wala talaga tayong idea..heheheh
Goodjob sir
Be the reason someone smiles today.be masayahin
Tenk u sir. Mali lng yung 2nd to the highest reading, pero ok ang xplanation.
Napaka husay talaga
Watching my friend
Nandito ulit naghihintay para sa iyong content and God bless kpowerpuc.
thank you sir god bless you
waiting po kitakits mamaya godbless
pinusuan kona po kayo..salamat po sainyong pagbbalik..godbless
Watching here bro
you are really creative team misayahin
Masayahin
Sira na ba ang compressor ng ref ko kung mga 20-30 seconds lang cya umaandar at nag ka shut off kaagad cya.pero paulit ulit naman sya kaso mabilis lang mag shut off.pinalitan ko na ng overload protector at bago pa ang kanyang relay.
Sir bat yung iba sabi nila is 2nd to the highest resistance is yon yung starting
Tama boss
Common highest
Second highest Starting
Lowest is Running😊
Ang galing ..sir, ask kulang what are the type of freon or gas at yung psi standard requires sa 1.hp,1.5 n 2hp pag nag charge ka? Salamat!
R410a 125psi-150psi
R22 60psi-80psi
Depende parin yan sa kinakargahan mo gamitan mo palagi ng clampmeter pag nag kakarga ka ng refrigerant.
Bakit sa iba highest starting… kng sau mster highest com cap
Bakit parang baliktad sir??dapat ang running ang pinaka lowest
isang beses png kukuha ng opposite
boss d b dapat lowest resistance ay running
Aba me hanapan na mangyayari hahahahaha
good hossam Elhello team
Yung sakin lg old model masmataas reading ng running kisa starting
master im eric fresh gradute ng tesda may tanong lang po ako sa eropa po ba may technician ding po ba kc po puro nag yeyelo doon tulad po ng belgium italy at canada may aircon po ba doon pagpasenyahan po ninyo kc nagtataka lang po ako kung meron po doin aircon salamat po baguhan lang po ako at marami po salamat
Meron po sir kadalasan ginagamit sa Europe ay HVAC pag tag init pwede e adjust para lumamig ang aircon, pag tag lamig naman pwede rin e adjust para warm ang ibuga ng aircon.
salamat po
Bossing KFF
Parang mali Bro.paki review uli. Running 2nd.
Ano man Noy ang hanpon dyan baga masakit iyan hanapon ahhh
Sir tanong lang po,kung ang common ay nakakonekta sa isang linya ng supply, saan naman po ikokonekta ang isang linya ng supply, sa start po ba o sa run? Salamat po sa pagtugon. GOD BLESS PO.
Baliktad drawing mo sir second to the highest run,ung lowest start winding nalito ka yata sir
2nd highest value is starting
Its a mans department lols sasakit bangs ko dyan.
paano po pag pareparehas ang reading ng mga terminals?
shorted na ata windings niyan
Wag maniwala may sasabog na compressor pag nagkataon..😅
Baligtad nman
Boss may Mali.
Highest resistance common
Second highest Starting
Lowest resistance Running
Pinapahamak mu naman yung mga baguhan na technician..😅
Tama ka. ❤
parang mali yata bossing
kulang
Paki actual boss para sumabog ka😅😂
Mali😅😅😅
magulo to
delete muna to