Sir for the proper compaction of sub grade of slab on grade it is better to consider the OMC-optimum moisture content of the soil so that you can get the proper compaction of 95% or more. Remember that dry soil cannot pass the FDT of 95%.
Hello engr ,,,,very interesting content mo at very nice good explanation din ,,,,,,kmusta ang epekto ng gamot against anay? Also anong brand ginamit against anay? Pls reply salamat ulit,,,
Thanks for sharing Sir Giordan. Queires lang po A. Baka pwd po kau gawa ng content for FDT full process till computation. B.Doon sa isolation joint ng poste , meron po bang standard dimensions. C.Standard time to start for power trowel after concrete pouring D.What about suspended slabs Sir. Baka pwd karin magawa. Thanks Again thanks for the info sir.
Hello po, ano po mas ideal na unahing buhusan? sog po ba or upper slab (2F) slab? Pwede ka po gumawa content about sa pag cut ng buhos? If masyadong malaki yung area na bubuhusan, like 15×24 floor area. Or better na buhusan na lang isahan then lagyan po ng contraction joints?
boss, eto yung comment ko sa SOG mo. i correct mo na lang ako!hahaha 1. yung sa overlapping ng vapor barrier mo parang maiksi, pangalawa sa construction joint wala naman nakaabang para overlapping ng vapor barrier. 2. bakit walang backer material dun sa isolation joint mo? 3. construction joint ba o contraction joint (14:10). 4. yung installation workmanship ng dowel (not sure) hahaha anyway!! nice vid idol!! mahirap talagang gawin yung nasa libro sa actual (workmanship)haha
Contraction joint Idol yung part na may cutting using Concrete cutter Construction Joint yung dugtungan ng Concrete formed by the Forms at Isolation Joint nman ang tawag dun sa parat n may pa triangle to isolate or separate the column to slab and sometimes tinatawag din itong construction joint.
May Backer material naman sa magkabilang dulo ng Forms sa part ng isolation joint idol, hi indi lng halata saka may Vertical stopper naman and aside from that tinupi lng yang purlins para mag act parin sila as one.
Hello Engr Aron! Thank you po sa additional knowledge sa field. Meron lng po ako sanang additional questions. Ginagamitan dn ba ng pangvibrate ung construction ng slab, if so, what kind of tool yung ma rerecommend nyo. Meron dn ba mga standards yung mga construction joints? Also ano po ba yung marerecommend niyo na reference for additional information about this subject.
engr! ang galing ng vids nyu, ask ko po sana ung concrete pouring sa slab, anung tawag sa equipment po na truck? tsaka ila po output ng nabubuhus nya per hour po? marami pong salamat!
Good day engr. Ask ko lang po re sa construction joint. Ano po depth ng putol nito? Halfway lang po ba before the depth hitting the rebar? Applicable din po ba ito sa slab sa residential
Wala naman pong problem nakpatong naman sa compacted Soil. ANG slab naman ay more on Compression kaya ang patitibayin niyo lng ay yung Lupa na papatungan ng slab.
For me Structural, pero nasa sayo naman yun Idol as long as masaya ka sa ginagawa mo nag eenjoy ka masasabing kong better fit ka with that Job. Pero kung hindi kana nag eenjoy Better na mag try ka ng Iba for you to find your interest.
@@ARONJAMESGARCIA ah. Okay po sir haha. Goodluck po sir sa journey niyo. Pero ganun po curriculum namin ngayon sir eh, pagpasok ng 4th yr, mamimili na ng specialization yung mga students.
Thickening slab di ba po para sa CHB yan boss? And yung para sa anay di po long lasting yan kaya dapat ata naglagay tubo tapos kinakargahan periodically.
Yes idol para sa Partition wall, naglalagay din kami ng thickening Slab sa mga gilid na hindi kayang abutin ng compactor " For warehouse na nagdadala ng mabibigat na load pero sa residential hindi nman needed na maglagay pa.
Good morning po sir @Aron James Garcia. Regarding po sa construction joint, pag nagcut po ng concrete flooring sagad po kasama rebar? Yung sinabi po nyo na after malagyan ng pilapil buhusan ng tubig para macure di ko po magets hehe? Ano po ang lalagyan ng water ang construction joint po ba? Paano po macure ang construction joint pag nalagyan ng water? Pasensya na po sir dami kong tanong. Thanks in advance po.
Kapag magCut ng Flooring for CONSTRUCTION JOINT hindi kasama ang bakal sa puputulin, a minimum of 50mm ang Depth ng Cutting sapat na para magtuloy yung cut sa ilalim ng Concrete.
Engr aron.. magtanung lang sana aku sa fdt.. anu ba yung diameter nung hole at anung lalim po..? At anu po ba yung sand na nasa cone po..? Anung klasing sand yun..?
Laser ? Hindi ito effective, Kung mapapansin mo gumamit kami ng C Purlins para pang porma, naka level ang C Purlins na ayon sa thickness ng Slab, gumagamit kami ng aluminum tubular na may sukat na 2x6 para magung shereder uoang pantayin ang Concrete, yung C purlins ang nagsisilbing guide para sa elevation, at gumagamit kami ng level instrument/Auto level para ma set ang C puroins sa tamang elevation.
Sir Kung hindi monolithic yung buhos naten sa beam at slab dahil sa kakulangan ng porma it is okei na mag iwan ng 100mm sa ating beam para sa slab kung ang slab ay nasa 150mmyung thickness ng suspended slab?..
@@ARONJAMESGARCIA kasi sa beam namen ay may depth xa na 50cm at yung base nya 30cm bale hindi ko xa pinuno para sa slab nag iwan ako ng 10cm for the suspended slab at saka kami lng mag poporma para sa slab nauna lng yung beam... Tapos na eh..
Apektado kasi yung effective Depth ng Beam, kasi kapag gumagawa kami ng Design, we consider "d" measure from the neutral axis ng rebar hangang sa outer most fiber.
@@jhatero587 kung Slab on grade no need to order PCD, G-1 pwede na mas mura since ang slab on grade. naman is more on compression kaya ang spacing ng bakal niyan nasa 400mm- 600mm lng kaya pasok ang G-1 na bato diyan
@@ARONJAMESGARCIA Contraction joints (sometimes called control joints) are used in unreinforced and lightly reinforced slabs-on-ground to minimize random cracking. By creating straight-line weakened-planes in concrete, contraction joints “control” the cracking location by inducing cracks at predetermined locations
@@jeffersonlavarias6190 Contraction ang tawag dun sa may part na May cutting or Sawed by the Concrete cutter, Isolation Joint naman ang tawag dun sa part na my pa triangle to Separate or isolate the slab sa Column it can be a Construction Joint also. Construction joint nman ang tawag dun sa part na may porma sa longitudinal direction ng buhos or ng Slab and formed sa pamamagitan ng porma.
Pinaghalong Gravel ang Sand as a filler. Pero yang ginagamit namin na klase ng base coarse yan po ay galing sa mga malalaking bato sa bundok kaya kapag nabasa tumitigas siya.
@@ARONJAMESGARCIA kayo na lang po ba naghalo nun sir? At may sinusunod ba na ratio Yun? At mga gaano kakapal po yung ginagawa nyo? Share ko po sa mga kaibigan ko channel nyo. Galing sir
Sir, tanong lang po. Saan ba ang tamang splicing zone/ area para sa suspended slabe rebars? Saan lang pwedi mag splice. Wla kasi ako makitang video. Thanks sir.
Sir for the proper compaction of sub grade of slab on grade it is better to consider the OMC-optimum moisture content of the soil so that you can get the proper compaction of 95% or more. Remember that dry soil cannot pass the FDT of 95%.
Thank you Sir, marami akong natutunan sa mga videos mo.
God Bless you.
Thanks sir @Aron James Garcia sa very nice and informative video. God bless po sir.
Amazing wow😱😱👌🏼
Ang galing mo po idol
gawa po kayo video about fd test. and many more tests regarding construction. Thank you!
Hi sir, newbie here. Steeldeck naman po next videos nyo sir thanks
Semding love and fullsuppport and keep vlogging giordan
Stay safe Giordan
ang galing.Giordan
Galing namn.keep safe.@giordan
❤️
Hello engr ,,,,very interesting content mo at very nice good explanation din ,,,,,,kmusta ang epekto ng gamot against anay? Also anong brand ginamit against anay? Pls reply salamat ulit,,,
Control Joints for cracking control
Galing naman talagang nakakamangha enjoy giordan
Ang galing naman ganun pala yun from Giordan
Keep on Vlogging Gedion
Ask ko sir pag sa mga pond po pag mag hukay at mag semento na ng floor need po ba lagyan ng gravel? Ung seeementohin
Thanks for sharing Sir Giordan.
Queires lang po
A. Baka pwd po kau gawa ng content for FDT full process till computation.
B.Doon sa isolation joint ng poste , meron po bang standard dimensions.
C.Standard time to start for power trowel after concrete pouring
D.What about suspended slabs Sir. Baka pwd karin magawa. Thanks
Again thanks for the info sir.
Sige Idol gawan natin ng Content yan
Ano mahal mgpaslab .. laki money kylangan .. fr giordan
Gandang Gabi po
Gano ko lang po
Pano po b mag estemati ng cemento graba at white sand
Sa slab na may sukat na 32sqr miter
Kalawak ng lugar GIORDAN
FDT Field density Test 95 Compaction
Hello po, ano po mas ideal na unahing buhusan? sog po ba or upper slab (2F) slab? Pwede ka po gumawa content about sa pag cut ng buhos? If masyadong malaki yung area na bubuhusan, like 15×24 floor area. Or better na buhusan na lang isahan then lagyan po ng contraction joints?
anong thickness ng poly??
yung pag renta ba ng trowell kasama na operator?
Bakit hind gamitan ng elephant foot compactor ang edges ng SOG.
You are doing proctor compaction test. How about penetrometer? It is much faster.
Chooks lang sakalam 💪
Sir, pano po magdesign ng reinforcement sa slab on grade?
Ok lang b nk primer paint anilyo
boss, eto yung comment ko sa SOG mo. i correct mo na lang ako!hahaha
1. yung sa overlapping ng vapor barrier mo parang maiksi, pangalawa sa construction joint wala naman nakaabang para overlapping ng vapor barrier.
2. bakit walang backer material dun sa isolation joint mo?
3. construction joint ba o contraction joint (14:10).
4. yung installation workmanship ng dowel (not sure) hahaha
anyway!!
nice vid idol!! mahirap talagang gawin yung nasa libro sa actual (workmanship)haha
Contraction joint Idol yung part na may cutting using Concrete cutter
Construction Joint yung dugtungan ng Concrete formed by the Forms at
Isolation Joint nman ang tawag dun sa parat n may pa triangle to isolate or separate the column to slab and sometimes tinatawag din itong construction joint.
May Backer material naman sa magkabilang dulo ng Forms sa part ng isolation joint idol, hi indi lng halata saka may Vertical stopper naman and aside from that tinupi lng yang purlins para mag act parin sila as one.
Hello Engr Aron! Thank you po sa additional knowledge sa field. Meron lng po ako sanang additional questions. Ginagamitan dn ba ng pangvibrate ung construction ng slab, if so, what kind of tool yung ma rerecommend nyo. Meron dn ba mga standards yung mga construction joints? Also ano po ba yung marerecommend niyo na reference for additional information about this subject.
Conrete Vibrator same with the vibrator use in pouring of Columns and other reinforce concrete.
Reference : DPWH Blue book.
@@ARONJAMESGARCIA Thank you Engr!
engr! ang galing ng vids nyu, ask ko po sana ung concrete pouring sa slab, anung tawag sa equipment po na truck? tsaka ila po output ng nabubuhus nya per hour po? marami pong salamat!
Concrete mixer.
Chooks to go baka naman haha😂 padugo haha
Hahaha,
@@ARONJAMESGARCIA idol matic meron naman yan pag may testing kung wala nung buhus haha😂
Yes Idol😁
Okay sana ung buhos mo sir kaso bleeding ung concrete.. malambot kasi ung halo e.
Hanep ang choox to go na plastic bag
Hahaha baka sakali mag sponsor 😁, nakalimutan nila magdala ng Pan kaya yan alternative.
choks to go lng malakas 😂😂
Hhahahahhaha
Good day engr. Ask ko lang po re sa construction joint. Ano po depth ng putol nito? Halfway lang po ba before the depth hitting the rebar? Applicable din po ba ito sa slab sa residential
Slab for Residential, hindi naman idol kasi hindi naman ganun kabigat yung load compare sa industrial at mga kalsada na mabibigat ang dinadala
Good day engr. tanong lang ano kaya possible solution if hindi nakapag abang ng dowel bars sa ground beam for slab on grade.
Wala naman pong problem nakpatong naman sa compacted Soil. ANG slab naman ay more on Compression kaya ang patitibayin niyo lng ay yung Lupa na papatungan ng slab.
Hi sir. Ask lang sa pag cut ng construction joint dapat po ba hanggang baba sa yung pag cut or half lang sa pag cut?
Thank you po for this video po
1inch lng pwede na po
Engr penge naman pong tips. What specialization is better? I'm stuck between construction management or stuctural? Thank you Engineer. 🙏☺️
For me Structural, pero nasa sayo naman yun Idol as long as masaya ka sa ginagawa mo nag eenjoy ka masasabing kong better fit ka with that Job. Pero kung hindi kana nag eenjoy Better na mag try ka ng Iba for you to find your interest.
@@ARONJAMESGARCIA Ah. structural ka po ba sir?
Hindi Idol, pero pinapractice ko siya, pero hindi ako entitled as Structural Engineer.
@@ARONJAMESGARCIA ah. Okay po sir haha. Goodluck po sir sa journey niyo. Pero ganun po curriculum namin ngayon sir eh, pagpasok ng 4th yr, mamimili na ng specialization yung mga students.
@@edwinsternagpacan494 wow ayos Yan Idol.
Kelangan ba sir chooks to go yung lagayan ng soil
Hahhahahaha😆😆😆.
Hindi naman Idol😁
Pwedi mag tanong sa isang bags na cemmento ilang buhangin at ilang grava yong tamang timpla salamat
czcams.com/video/GLekIyLJX4Q/video.html
Thickening slab di ba po para sa CHB yan boss? And yung para sa anay di po long lasting yan kaya dapat ata naglagay tubo tapos kinakargahan periodically.
Yes idol para sa Partition wall, naglalagay din kami ng thickening Slab sa mga gilid na hindi kayang abutin ng compactor " For warehouse na nagdadala ng mabibigat na load pero sa residential hindi nman needed na maglagay pa.
Boss Baka po may materials price list po kayo jan for construction. Pwede pong mahingi?
Send ko Bukas Idol, nakalimutan ko isend😁, Sorry.
Boss bak pwde makahingi rin materials price list for contruction
Good morning po sir @Aron James Garcia. Regarding po sa construction joint, pag nagcut po ng concrete flooring sagad po kasama rebar? Yung sinabi po nyo na after malagyan ng pilapil buhusan ng tubig para macure di ko po magets hehe? Ano po ang lalagyan ng water ang construction joint po ba? Paano po macure ang construction joint pag nalagyan ng water? Pasensya na po sir dami kong tanong. Thanks in advance po.
Yung mismong ibabaw ng Slab po lalagyan ng tubig for 3 do day, hindi po yung dugtungan ang lalagyan ng tubig
Kapag magCut ng Flooring for CONSTRUCTION JOINT hindi kasama ang bakal sa puputulin, a minimum of 50mm ang Depth ng Cutting sapat na para magtuloy yung cut sa ilalim ng Concrete.
Gets ko na po sir. Thank you so much po sir and God bless.
sir bat nilalagyan ng pilapil na sand yung contraction joint?
@@rangom812 ang purpose nung pilapil ay para sa Water ponding hindi yun para sa Contraction Joint. Nagkataon lng na dun nilagay yung buhangin.
Sir idol engineer,bagong subscriber mo pa notice.....tanong ko lng anong tawag s chemical spray s lupa n pra s anay??
LEADREX ginagamit namin.
Careful lng sa pag gamit after mag apply dapat maghugas ng kamay yung taong nag spray.
Engr aron.. magtanung lang sana aku sa fdt.. anu ba yung diameter nung hole at anung lalim po..? At anu po ba yung sand na nasa cone po..? Anung klasing sand yun..?
If you use 100mm or 4" na Diameter ng hole ang lalim nito ay 4" din
For 6" Diameter hole 6" din ang lalim
Otawwa Sand.
Napansin ko din ,,,paano ang level ng concrete finish? Hindi ginamitan ng lazer levelling?pls xplain
Laser ? Hindi ito effective,
Kung mapapansin mo gumamit kami ng C Purlins para pang porma, naka level ang C Purlins na ayon sa thickness ng Slab, gumagamit kami ng aluminum tubular na may sukat na 2x6 para magung shereder uoang pantayin ang Concrete, yung C purlins ang nagsisilbing guide para sa elevation, at gumagamit kami ng level instrument/Auto level para ma set ang C puroins sa tamang elevation.
Mahusay nman ,,,maraming salamat din Engineer...more power!
Compressive strength and mix po ng concrete, engr?
3k Psi
Regarding sa Design mix may nauna akong na upload na video yung mga value dun yun din yung ginamit diyan sa Slab na yan, try to view Sir😊
sir, gaano kakapal ang slab sa warehouse sa video sir?
150mm
Sir Kung hindi monolithic yung buhos naten sa beam at slab dahil sa kakulangan ng porma it is okei na mag iwan ng 100mm sa ating beam para sa slab kung ang slab ay nasa 150mmyung thickness ng suspended slab?..
Hindi po siya pwede,. Ganito nlng gawin mo idol kung hindi kaya buong slab pwede mong gawing dalawang buhusan yung Slab.
@@ARONJAMESGARCIA kasi sa beam namen ay may depth xa na 50cm at yung base nya 30cm bale hindi ko xa pinuno para sa slab
nag iwan ako ng 10cm for the suspended slab at saka kami lng mag poporma para sa slab nauna lng yung beam... Tapos na eh..
Apektado kasi yung effective Depth ng Beam, kasi kapag gumagawa kami ng Design, we consider "d" measure from the neutral axis ng rebar hangang sa outer most fiber.
PWEDE PO BANG GAMITIN ANG POWER TROWEL SA SUSPENDED SLAB?
Yes Idol pwede.
Engr. Pareho lang po ba SOG and SOF?
Yes po
Sir pa help naman po. Which one is safer or better ma una ba buhos ng slab or columns? Maraming salamat po
Slab on grade ba? Column po muna bago slab.
anong thkness ng polyethylene sheet n ginamit nyo engineer?
0.25mm idol
@@ARONJAMESGARCIA salamat Engr 👍🥰
Sir saan po nakakabili ng polyethylene? May link po ba kayo? Thanks po
For base coarse engr. What alternate material do you recommend?
G-1 but more expensive
Okey lang po ba 3/4? Yung gamit namin sa manual concreting ng poste at grade beams. Or better G1 na lang po?
3/4 malaki na po kasi yang G-1 mahirapan ng pumasok sa mga pagitan ng bakal
How about po sa slab on grade po? Sa gen notes namin ang slab on grade po G1. But is it okey to order 3000psi 3/4 28days pcd?
@@jhatero587 kung Slab on grade no need to order PCD, G-1 pwede na mas mura since ang slab on grade. naman is more on compression kaya ang spacing ng bakal niyan nasa 400mm- 600mm lng kaya pasok ang G-1 na bato diyan
Ilamg mm po ba ang spacer na ginamit nyo?
75mm gamit niya
sir, anong tawag doon sa hindi nabuhusan malapit sa column?
Isolation Joint
Engr anong sukat ng spacer nyo thanks
Footing
3-4inches in Diameter x 3 inches thick
Comlumn & Beam
2inches in Diameter x 40mm thick
Suspended Slab
2inches in Diameter x 20mm thick
hindi ba control joint ang tawag dyan engineer?
Contraction Joint
@@ARONJAMESGARCIA Contraction joints (sometimes called control joints) are used in unreinforced and lightly reinforced slabs-on-ground to minimize random cracking. By creating straight-line weakened-planes in concrete, contraction joints “control” the cracking location by inducing cracks at predetermined locations
Suggest lng alisin nio nlng po un "a few moments later" irritating n po and redundant po. Sayang s seconds of info
Ang reklamador mo, nanood ka pa...ungrateful person!
Required curing time natin ?pls..
3 days po idol
Maraming salamat....Engr Aron
Constructiom joint ba tlaga yun sir or contraction/control joint.
@@jeffersonlavarias6190
Contraction ang tawag dun sa may part na May cutting or Sawed by the Concrete cutter,
Isolation Joint naman ang tawag dun sa part na my pa triangle to Separate or isolate the slab sa Column it can be a Construction Joint also.
Construction joint nman ang tawag dun sa part na may porma sa longitudinal direction ng buhos or ng Slab and formed sa pamamagitan ng porma.
Nice video sir. Tanong lang po, yung sub base course po, ano po ba ito?
Pinaghalong Gravel ang Sand as a filler.
Pero yang ginagamit namin na klase ng base coarse yan po ay galing sa mga malalaking bato sa bundok kaya kapag nabasa tumitigas siya.
@@ARONJAMESGARCIA kayo na lang po ba naghalo nun sir? At may sinusunod ba na ratio Yun? At mga gaano kakapal po yung ginagawa nyo? Share ko po sa mga kaibigan ko channel nyo. Galing sir
@@yieldstress Ready mix na po siya Idol, pagkabili sa mga supplier ng aggregates.
@@ARONJAMESGARCIA nice idol. Wala lang dito sa mga hardware sa min.. pwede na kaya graba na lang at buhangin na hinalo?
Para sa Residential po ba?
Or ung my butas ung parlines nyo,, hnd ko kc nakita na my abang kau para sa next span
May Dowel Bar yan Idol na 16mm para sa Dugtungan ng next span😊.
My napapansin ako sir,, ung forma nyo na parlines, parang walang nakalabas na bakal para sa next nyong span
Kung mapapansin niyo yung purlins may butas, naglalagay nlng kami ng Dowel Bar.
Good idea idol
gaano kahaba ang dowel na nilalagay sir... nka hook parin ba sir or straight lng? thanks sa pagsagot sir.. 😊😊😊
0.6m wala ng hook
Sir, tanong lang po. Saan ba ang tamang splicing zone/ area para sa suspended slabe rebars? Saan lang pwedi mag splice. Wla kasi ako makitang video. Thanks sir.
Splicing zone for slab located at 0 bending moment usually located at L/3- L/5 where
hello po, may tanong po ako. Ano pong dimension ng thickening slab po?
150mm or 6in.
Pero kung residential 100mm or 4in.
you mean to say sir galing sa bottom ng slab natin, bababa pa ng 150 or 100 po? how about yung slope nya po? hehehe
@@aeronsycezar yes Idol Total of 0.3m yung Thickness at yung slope naman is 45degrees.