How Defrost Works on a Heat Pump! Explained Step by Step!

Sdílet
Vložit
  • čas přidán 27. 07. 2024
  • In this HVAC Training Video, I show the Defrost Sequence of Operation on a Heat Pump and I Explain How Each Component Works and is Powered. The Outdoor Fan shuts off, the Reversing Valve changes the direction of the refrigerant, and the W Terminal sends power to the indoor air handler to power the Electric Strip Heaters! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos/Articles
    • How an Air Handler & H...
    • Air Handler Control Bo...
    • Heat Pump Thermostat W...
    • Air Handler with Elect...
    • Heat Pump Fan not Runn...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.com/show/74KXLz5...
    Apple Podcasts: podcasts.apple.com/us/podcast...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #defrost #component #reversingvalve #valve #airhandler #eletrical #stripheating #heating #heaters
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Komentáře • 137

  • @acservicetechchannel
    @acservicetechchannel  Před 3 lety +3

    -Thermostat Wiring Quizzes www.acservicetech.com/quizzes
    -Our Website has FREE Videos, Calculators, Podcasts, Articles, Tips, Quizzes, Q/A: www.acservicetech.com
    -Facebook Tips: facebook.com/acservicetech
    -Tools we use, Our Book, Workbook, and Quick Cards: www.amazon.com/shop/acservicetech
    -Join our updates list for an email strictly from us for new videos, articles, products and website features! www.acservicetech.com-Our E-book, Paperback, Workbook, Quick Cards, PowerPoints, www.acservicetech.com/store
    -Posters, Book, Workbook, Cards on Amazon: www.amazon.com/shop/acservicetech
    -Our E-book: play.google.com/store and iTunes and search "ac service tech"
    -Posters & PowerPoints on our Website: www.acservicetech.com/store
    -Spanish Paperback and E-book: www.acservicetech.com/libros-en-espanol

    • @saulsanchez9531
      @saulsanchez9531 Před 2 lety

      id like you to make a troubleshooting book how to diagnose control boards ,pressure switches ,reveasing valves and all components that the heat pumps , air handle and the funace especially in spanish

    • @jeffreybricks2687
      @jeffreybricks2687 Před rokem

      Hey ac Service Tech, if the unit shuts off during the run timer let's say is 40 minutes and it shuts off after 20 and than runs agian will it pick up where it was when the heat turned off?

  • @Sam-dc7qp
    @Sam-dc7qp Před 3 lety +26

    Best Teacher hand's down

    • @jollyscaria1922
      @jollyscaria1922 Před 2 lety

      Systeom not pnp dow no pressar relaszbai

    • @jollyscaria1922
      @jollyscaria1922 Před 2 lety

      Ok gas revomed need mut pump down peger only down ok big pint

    • @NROhvac
      @NROhvac Před 5 měsíci

      Yes, he is hands down the best

  • @thaitichi
    @thaitichi Před 3 lety +4

    I've asked this question several times online and nobody ever seems to know the answer. You are amazing!

  • @falconewk
    @falconewk Před 3 lety +16

    Excellent video, simple enough for this electrician trying to develop his HVAC knowledge. Thanks Craig! Your book has been helpful as well.

  • @mixtecooaxaqueno6730
    @mixtecooaxaqueno6730 Před 3 lety +7

    One of the best hvac teacher in youtube, I'm learning a lo from your videos and book.

  • @Joe_Joe_The_HvacMan
    @Joe_Joe_The_HvacMan Před 3 lety +6

    I have been an instructor and in the field for 30yrs. This is an EXCELLENT presentation on time/temp defrost system! GOOD JOB!!

    • @acservicetechchannel
      @acservicetechchannel  Před 3 lety

      Thank you very much and thanks for teaching techs. It takes passion to teach for 30 years, awesome!!!

  • @shooter2843
    @shooter2843 Před 3 lety +11

    Another great video. I wasn't ready for the trade after trade school, your videos helped more than I can say.

  • @bigwhitemeathead7684
    @bigwhitemeathead7684 Před rokem +1

    Your series of videos helped me locate and fix a high voltage short in the condenser and a low voltage short in the thermostat wire. This was after the professional hvac techs gave up. Thank you for creating the excellent heat pump videos and for your excellent explanations in each and every one of them!

  • @jkbrown5496
    @jkbrown5496 Před 3 lety +4

    I have adaptive defrost on my system. It failed last year, with a board and thermistors replacement. But I looked into how it is different than the traditional time/thermostat defrost.
    It has a coil temp sensor (thermistor) instead of a thermostat and an ambient temp sensor (thermistor). It has some algorithm that determines when to defrost based on the comparison. I did learn if the ambient temp sensor fails, the board defaults to a 30 minute time cycle (and uses the same when it is first powered up till it gets a "sense" of the temperature profile). If the coil sensor fails then defrost stops like with a thermostat. Also, the selector pins on the board don't adjust the time, but rather the coil defrost termination temperature. Haven't been able to find much on the why or wherefore of raising or lowering the termination temperature.
    Testing spare coil and ambient thermistors, I noticed the resistance test current on the meter will cause them to climb reading as it warms them up. So you have to be quick about taking the reading if you want to convert it to a real world temp. Haven't found any good information of field testing for sensor drift. So it is kind of open, shorted, or seems close enough to my outside air temp reading for testing.

  • @adamcraig1568
    @adamcraig1568 Před 3 lety +3

    Great video. Waiting for the communicating systems to be on here

  • @vnesmuonnam
    @vnesmuonnam Před 3 lety +3

    Save me a lot time and money on books. Thank you

  • @jeffreybricks2687
    @jeffreybricks2687 Před rokem +1

    You also seem like a very positive and great person, thankyou Craig!

  • @drprofessor1414
    @drprofessor1414 Před rokem

    You’re a wonderful teacher, so eloquent with your words. Very intelligent friend, thank you for your efforts and knowledge!

  • @brianosegueda3622
    @brianosegueda3622 Před rokem

    Excellent explanation of what happens in heat pump mode.

  • @jeffreybricks2687
    @jeffreybricks2687 Před rokem +1

    You make everything so simple man THANKYOU!

  • @tserevenad
    @tserevenad Před 2 lety

    DIYer here, .... wow mind bending. big respect to you pros!

  • @CHOMAHOMA
    @CHOMAHOMA Před 3 lety +1

    Thank you very much for your videos. They always help me to understand HVAC and to improve my skills every time.

  • @primusheating1
    @primusheating1 Před 3 lety +3

    Always clear and precise from you my friend.

  • @aaronwynkoop7066
    @aaronwynkoop7066 Před 3 lety +2

    Awesome job. If you could do a video on furnace and the components and maybe show the wiring that would be awesome

  • @pingpong9656
    @pingpong9656 Před 2 lety

    Master class teacher - really clarifies the defrost

  • @albotiger7268
    @albotiger7268 Před 3 lety +4

    Very good explanation. Great videos as usual!

  • @acrepairnearme
    @acrepairnearme Před 3 lety +1

    Brilliant! Best teacher on CZcams!

  • @D2O2
    @D2O2 Před 3 lety +1

    Turning the aux heat source on also adds energy to the refrigerant raising compressor discharge temp making for a quicker defrost.

  • @HillBillyGaragew
    @HillBillyGaragew Před rokem

    Good job on explaining easy to understand you!

  • @hkhsm359
    @hkhsm359 Před 3 lety +2

    Nice video. Great knowledge.
    Thanks for sharing

  • @jesusdelgado2232
    @jesusdelgado2232 Před 2 lety

    Awesome Vid, I needed this refresher!

  • @8joh58
    @8joh58 Před rokem

    Great explanation Craig 👍

  • @walterrisco4236
    @walterrisco4236 Před 3 lety +1

    Really good explanation very clear am glad that your share all your knowledge of hvac thanks. :)

  • @gotchaplumber
    @gotchaplumber Před 4 měsíci

    Great explanation!

  • @Demy26
    @Demy26 Před 3 lety +2

    Great explanation

  • @buddycheck84
    @buddycheck84 Před 3 lety +6

    How you have the time to make these great videos and not be in demand to teach in person across the country (all things equal of course) is beyond us,,!!!

  • @JeanMedard-fh6fj
    @JeanMedard-fh6fj Před 7 měsíci

    Really good video!

  • @eman3208
    @eman3208 Před 3 lety +2

    another awesome video.. Thanks!

  • @user-kh7zt4ti5x
    @user-kh7zt4ti5x Před 3 lety +1

    Very helpful, thank you

  • @hanound79
    @hanound79 Před 3 lety +1

    Useful information 👍

  • @eternallife721
    @eternallife721 Před 7 měsíci

    Very nice video. Thank you very much.

  • @omarr.r1448
    @omarr.r1448 Před 2 lety

    Awesome video

  • @juancarlossalcitas1690

    We love your videos

  • @campbull_7815
    @campbull_7815 Před 3 lety +2

    Great video

  • @tecniman356
    @tecniman356 Před 2 lety

    You are the best!

  • @montes5686
    @montes5686 Před 3 lety +2

    Good video thx

  • @humbertomacias3239
    @humbertomacias3239 Před 10 dny

    Amazing

  • @Ted_E_Bear
    @Ted_E_Bear Před 3 lety +1

    Great information !

  • @jjjames5089
    @jjjames5089 Před rokem

    Great detail in your teaching, keep it up.
    Perhaps you could help, I need a parts catalog for an old Goodman model CPK224-1B heat pump.
    I'm having trouble finding the right reversing valve coil.

  • @charlesmorgan2234
    @charlesmorgan2234 Před měsícem

    All your vids are great including this one! My only question is when the heat pump turns on electric heating in the air handler does it also turn on the air handler blower?

  • @sharky5570
    @sharky5570 Před 3 lety +2

    Question what is the lowest outdoor temps that these things run in? I have had the things running in temps to mid teens. Ohio.. Also in a pinch I have had the dfs go bad and jumped it out till new one arrived. It would be in defrost for 10 min and go back into hp operation. Carrier did not know if it would work but it does because of the timer. Great video.. subscribed.

  • @thehifiwifiguy
    @thehifiwifiguy Před 2 lety +3

    Why don't they build heating elements into the coils to prevent this? It would potentially use less electricity than the coils in the handler IMO. It would also prevent the excessive reversing valve use.

  • @nickledimez4012
    @nickledimez4012 Před 3 lety +1

    Buy his book! Great investment

  • @johndoe-wt4ui
    @johndoe-wt4ui Před 3 lety

    🙌 the best the 🐐the legend

  • @NOVAServicesLLC
    @NOVAServicesLLC Před rokem

    Any clearer and I’ll see my reflection 😂all jokes aside awesome video and very informative.

  • @x-man4702
    @x-man4702 Před 2 lety

    Subscribed! Thanks for the video, very informative! Quick question: While the system is in defrost mode, does the fan inside the house runs simultaneously? If so, why?

    • @MaMa-qh4dy
      @MaMa-qh4dy Před 2 lety +1

      Yes it does. In doing so, the fan helps to transfer heat from inside the structure to the outdoor coils to defrost the ice. Additionally, the indoor fan blows air over the resistance strip heaters to heat the "cool" air due the the unit running in a/c mode during defrost cycle.

  • @spelunkerd
    @spelunkerd Před rokem

    When in air conditioning mode, is there a similar defrost cycle to prevent freezing of the indoor coil? Why not? Is it because ambient temp in the home rarely gets so close to the freezing point? If you do see freezing of the indoor coil while in AC mode, do you think of other causes like a dirty filter, low freon charge, or other causes of poor air flow?

  • @mjfollrd
    @mjfollrd Před rokem

    Can the heat pump only go into defrost on a heat call or does the DTS put it into defrost automatically no matter what if heat pump is running of not Great Video Thanks

  • @thisisyourcaptainspeaking2259

    Found my defrost sensor dangling, disconnected from the coil tubing, where should it be mounted, before/after the "evaporator"?

  • @HVACRTECH-83
    @HVACRTECH-83 Před 3 lety +3

    Or it will power up the gas burners on a gas/dual fuel setup during defrost

    • @jkbrown5496
      @jkbrown5496 Před 3 lety

      The defrost board puts power on the W wire (independent of the thermostat) so what ever heat source W controls will come on.

  • @OcRefrig
    @OcRefrig Před 3 lety +2

    Good video ! Like #104.

  • @enduringpromise
    @enduringpromise Před 3 lety

    Hello Craig, I know this question is not related to the video. I could not find the answer on you other videos. Two questions...
    1. Is there a way to bleed the small air bubble in the BODY of the manifold gauges or is it so minimal that no one worries about that air bubble?
    2. If you do not connect the yellow hose to the tank, how do you return the high side refrigerate to the HVAC using a 3 value manifold gauge set? I believe the yellow line would be full of air and there is no valve available to isolate it from the body. Thank you for everything you do. I love listening and watching to all of your videos.

    • @sprockkets
      @sprockkets Před 3 lety

      Better solution, don't use archaic manifolds for checking pressures. Use probes. And if you are against electronics, use the analog equivalent, and you won't have to worry about it.
      And if you are worried about the high side and losing liquid, use this:
      www.trutechtools.com/Accutools-Shrader-Depressor-Tool-5-16Fx1-4M

  • @toolemanful
    @toolemanful Před 3 lety

    Off the subject what is a reset relay?? And how is it drawn? Thank u

  • @mikesweet9623
    @mikesweet9623 Před 2 lety

    Hi, thanks for a very helpful video that you've shared with us. My question is that when it is difrosting and the gun of thr heat pump stoped working, is it normal that the compressor making a huming noise. should i let it run?; if so for how long it must run to defrost the heat pump. thank you.

    • @MaMa-qh4dy
      @MaMa-qh4dy Před 2 lety +1

      The hum you hear from the compressor is usually masked by the loud noise of the fan. It is normal noise. Depending on what model unit you have, some defrost according to "time," and some defrost according to demand (outdoor coil and outdoor ambient temperatures). Just let it do its thing.

  • @jeff-w
    @jeff-w Před 7 měsíci

    Its amazing how refined the operation of these machines is, while at the same time its comical how archaic and sloppy the controls are.

  • @tylerlyons8109
    @tylerlyons8109 Před 3 lety +1

    One thing I would correct here, the timer does not start counting run time until the defrost sensor closes, it does not "check" the sensor every 30/60/90 minutes, this is a common misconception that I also thought was the case for years, until I had a debate with another tech about this, we made a bet and bench tested a few different boards, I lost, might make for an interesting video

    • @helobeast
      @helobeast Před 3 lety

      And what you find im curious. Cause im thinking about putting mine on 30minutes or should i leave it at 60 minutes??

    • @jkbrown5496
      @jkbrown5496 Před 3 lety +1

      I traced out a simple Goodman board and was surprised to see that, as you say, the board isn't even powered till the DFT closes. R to the board immediately goes out on the 2nd R terminal (with no other connections on the board) and the DFT terminal is the start of all the circuitry. So the DFT has to be closed to power the board. However, my current system with adaptive demand defrost is has always-on power via R. It even separately monitors the HPS and LPS instead of series wiring.

    • @tomozinga2267
      @tomozinga2267 Před 3 lety +1

      Tyler is correct. This is a common misconception, it’s presented incorrectly in many training videos and books. But that defrost timer does not run unless the defrost thermostat is closed.

  • @mark_Hershey
    @mark_Hershey Před rokem

    During defrost mode is the evaporator getting cold or does refrigerant not reach indoor coil?

  • @magnito9811
    @magnito9811 Před 11 měsíci

    what happens to the inside coil during defrost ? system basically runny on ac mode wouldn’t the inside could be cold and counter act the electric heat?

  • @manna5610
    @manna5610 Před 8 měsíci

    Is there a timer on how long the heat pump will run in heat mode before the elements will turn on? My hp will run to about 88 deg, then temp will start to drop (about 5 min), and the elements will turn on until the set temp is reached. this happens every time I start the hp in heating, even if I continually, adjust the set temp to turn off the hp and them turn it right back on. Service tech told me it is running fine, but could not explain why the elements keep turning on every time. Thanks for any help.

  • @charliemendez1479
    @charliemendez1479 Před 5 měsíci

    0:25 when this happens coil in air handle is cooling while aux heating at the same time?

  • @craigalan7911
    @craigalan7911 Před 2 lety +1

    Hi. I’m a very tech savvy homeowner. My heat pump was diagnosed with a bad defrost board. I would like to do a self install. Other than swapping out the board, does it require any kind of recalibration or anything?

    • @MaMa-qh4dy
      @MaMa-qh4dy Před 2 lety +3

      No. Just be sure to disconnect power to both the outdoor unit as well as the indoor unit. You don't want to get killed, and you don't want to short-out your low voltage transformer and/or fuse.

  • @elizabethmasih4602
    @elizabethmasih4602 Před rokem

    My AC contensate pump do not start automatic when the reservoir tank is full but the contender outside get shut off and air handler keep running

  • @jasonwee4305
    @jasonwee4305 Před 3 lety +2

    Hi Craig
    Thank you for the awesome video and explanation
    Question : I've come across numerous H/Ps that have had the board and DFT replaced. My question is where do you think the best location for the DFT is, because sometimes I've seen them located right after the outdoor txv, or right (seems to be) the exit for the condensing coil.
    Thanks in advance

    • @acservicetechchannel
      @acservicetechchannel  Před 3 lety +3

      I would like to see them need the middle of the outdoor coil but between the outdoor coil and the metering device works as well.

  • @chrissauter7501
    @chrissauter7501 Před 3 lety +1

    How are we supposed to know when to use O or B?

    • @sprockkets
      @sprockkets Před 3 lety +2

      Rhreem and it's brands use B. Almost everyone else does O.

  • @BornToFly4031
    @BornToFly4031 Před 5 měsíci

    How does a dual fuel (Propane) defrost work (Trane 18xi) if cutout/balance temp is set to 26 degrees? And temp never gets above 26 for a few days?

  • @solexxx8588
    @solexxx8588 Před 8 měsíci

    I would think that a hot gas bypass is more efficient for defrosting and consumes less power than turning on a resistance coil.

  • @Ray-wr2wr
    @Ray-wr2wr Před měsícem

    where is 24v coming from to the reversing valve ?

  • @charliedc2A
    @charliedc2A Před 2 lety

    My defrost is set to 30 minutes will this be ok

  • @mindcreation3591
    @mindcreation3591 Před 3 lety

    Sir there is a Hitachi inverter AC. R-410a has gas. Ampere 4.1. But sir cooling is not happening. What's the problem with that, sir?

  • @joebar2249
    @joebar2249 Před měsícem

    Hallo
    My mitsubishi heat pump stops after a half our and unit outside is frozen..
    Wher should I look for the problem..Gas is checked and refilled by technician, but no sulution.

  • @johnconnor7501
    @johnconnor7501 Před rokem

    I don’t understand. So the 60 minute timer is just to have the board check one switch every 60 minutes? If it is why not keep it at 30 minutes instead so it check as often as possible since the temperature switch is the one actually making the decision to turn on defrost?

  • @kitchenratt
    @kitchenratt Před 3 lety

    👍👍👍

  • @dymarke
    @dymarke Před 2 lety

    Can I ask a question about a 4 zone mini split heat hump?
    I have oddities in my defrost cycle. I have a 4 zone C&H Sophia with ceiling cassettes. Usually all cassettes will defrost together but I have one cassette that will go into a defrost cycle when the other cassettes are still heating. Occasionally that cassette will stay in defrost and not complete the cycle. I have also had two cassettes (only two running at the time) that did not complete the defrost cycle and just didn't start up again. Power cycling returns proper function. This is a new system and my first mini split so I am still learning but this seems like odd behavior. Any thoughts would be appreciated.
    Thank you

    • @acservicetechchannel
      @acservicetechchannel  Před 2 lety

      I would contact their tech support to explain what is happening and determine the cause, thanks!

    • @dymarke
      @dymarke Před 2 lety

      @@acservicetechchannel
      I did email them with no response but I will try again.
      Thank you

  • @johndeez2012
    @johndeez2012 Před 2 lety

    mine pumps cold air when in defrost mode

    • @MaMa-qh4dy
      @MaMa-qh4dy Před 2 lety +2

      It should do that. But your strip-heaters in the indoor air-handler should turn on to warm the cold air that is blowing over the indoor coil.

    • @johndeez2012
      @johndeez2012 Před 2 lety

      @@MaMa-qh4dy so my strip heaters might be bad

  • @throttlebottle5906
    @throttlebottle5906 Před 3 lety +1

    heat pumps work great, without power, just ask Texas! (ok that was an uncalled for low blow lol) I almost feel bad about their overall not expecting the worst and having some form of backup plans in place or at minimum some work-around means. :| sad place of life survival skills and surroundings means to accomplish such the USA has become

  • @erichorton1440
    @erichorton1440 Před rokem

    Pause at 6:47 and tell me his thumb isn't fake.

  • @jakemilkovich1722
    @jakemilkovich1722 Před 3 lety

    In your given example, if the defrost cycle is a maximum of 10 minutes, why the expense and added
    complexity for emergency heat? 10 minutes of no heat, for an average building, should not even be
    noticed.

    • @acservicetechchannel
      @acservicetechchannel  Před 3 lety +1

      The problem is that its not that the indoor blower shuts off. It is literally running in air conditioning mode and the refrigerant is absorbing heat from the building in order to move it outside to melt the ice. You can stop the indoor blower because then there will be no heat in the refrigerant to melt the ice outside, thanks!

    • @sprockkets
      @sprockkets Před 3 lety

      Indoor creature comfort.

    • @enduringpromise
      @enduringpromise Před 3 lety

      @@acservicetechchannel FYI, missed the word, "not". Cannot stop the blower...

    • @jkbrown5496
      @jkbrown5496 Před 3 lety

      You'd be surprised how pissed off you get when your heat is blowing cold(ish) air. Even though objectively it only reduced the temp 1 degree. I started watching these videos because my system had issues. I finally learned the right questions to ask. My defrost board has two rows of terminals, input and output. When installed they'd put the W wire on the input terminal. I don't cuss the AC guy who installed the system all winter anymore.

  • @sgtfixer
    @sgtfixer Před rokem

    Does a heat pump make a loud woosh sound during this process? I’m concerned something is wrong with my girlfriends condenser.

    • @MaMa-qh4dy
      @MaMa-qh4dy Před rokem +1

      That is normal when reversing valve goes back to heating mode causing the refrigerant flow to be reversed.

    • @sgtfixer
      @sgtfixer Před rokem

      @@MaMa-qh4dy thanks!

  • @realestateservicessaleshea99

    👍🏌
    Stay safe.
    Retired keyboard super tech.
    Wear your safety glasses.

  • @kevinvillal6169
    @kevinvillal6169 Před 3 lety

    This nigga can teach

  • @yamahasuperbike2202
    @yamahasuperbike2202 Před 3 lety +1

    I currently have a heat pump at my residence. I'll never own another one again. Piece of shit. Not very warm in the winter and not very cold in the summer.

    • @MaMa-qh4dy
      @MaMa-qh4dy Před 2 lety +1

      "Not very warm in the winter" -- NORMALLY TRUE. "Not very cold in the summer" -- then, you have a problem with your unit.

  • @r410a8
    @r410a8 Před rokem

    If a heat pump is air-water the indoor electrical resistances does continue to heat up the water? This doesn't require a nominal electric power comparable to nominal heat power of indoor exchanger element that is working like condenser in normal cylce,producing the heat power of rifrigerant compression plus refrigerant evaporation latent heat? And what happens to total electric power consume for this few minites if the machine has to consume power for compressor + electric power that equals compressor+evaporator (on normal cycle conditions)?,Doesn't this reduce dramaticaly the instant heat cop of heating from a scale multiplicate of 1 ,for instance 4,to a number lower than 1?
    If a machine gets freeze all the time and gets turn on the defroast cylce frequently for instance 1 time per hour for 10 minist ,the total cop won't be lower than a nominal eventualy?
    For instance assume a large heat pump with a nominal heat production 1Mbtu/h has a theoritical average hourly cop for a cold outdoor conditions 3,5,then to 1 hour only 1/3,5 Mbtu electrical power has been absorbed by the electrical grid and the rest 1-(1/3,5) has been absorbed as heat by the outdoor unit. If and a defrost 10 min need to be turned on ,the defrost cycle cop is 1 (because heat resistants produce all the demanding work for the defrost time,that equals 1Mbtu/h*(10min/60min) are produced now from heat resistants without having the 3/4 parts to been pumped from outdoor enviroment ) minus 1/3,5 (the theoritical work of compressor that it continues work and consume grid power without producing any good heat work indoor ,that equals 1Mbtu/h*(10min/60min)*(1/3,5) cop) = 10 minites defrost cop 1-0,285 = 0,714.So the total hourly cop isn't 3,5 but 3,5*(50min/60min)+0,714*(10min/60min)=3,035.If my calculations are right then with more time defrost cycle the more less expected average cop will you have in far cold enviromments .
    Is this a vfm thing taking to account the extraordinery coast of electrical power and the fact that the heat pump is selected for energy and money save?