Adding New Cat6A Ethernet Network Cable Around the House! Thanks to FS for Sponsoring this Install!

Sdílet
Vložit
  • čas přidán 30. 10. 2022
  • I have been meaning to remount our Home TV on the wall and needing to add network drops behind the TV on the wall. Well finally after months of planning, I can finally move forward on the project. Not only did we add 4 Ethernet drops behind the TV but we also added two more ethernet drops on the outside of my house for some PoE IP Cameras. Huge shout out to Fiber Store (FS.com) for sponsoring this video so I could make this project finally happen.
    Products provided by FS.com
    123982 Cat6a Ethernet Bulk Cable: bit.ly/3eDnbAq
    20248 Single Gang Wall Plate: bit.ly/3T3ikrc
    152463 Keystone Jack: bit.ly/3yGvlPD
    All other things used in this video
    Fish Tape - amzn.to/2JUPF5Z
    In wall power - amzn.to/3NN5BaC
    GE 110 Punch Down - amzn.to/3a3VfNM
    Klein Crimper - amzn.to/2JYiBdg
    Patch Panel - amzn.to/3egWCvR
    Tripplite Network Rack - amzn.to/39ZzS0k
    Milwaukee Drill - amzn.to/2RxtJSv
    Milwaukee Spade Bits - amzn.to/39hb9Yt
    Klein Tool Belt- amzn.to/2UYUkKi
    GE Wire Cutter - amzn.to/2JZ2NXS
    DYMO Label Maker - amzn.to/2V3avW6
    Husky 5000 Lumen Light - amzn.to/33fVswU
    ✪Support the channel✪
    www.amazon.com/shop/spxlabs
    spxlabs.com/links
    spxlabs.com/shop
    ts.la/stefano66335
    Visit
    spxlabs.com
    Chat
    / spxlabs
    / discord
    @FS_com
    #FScabling, #FS4homelab, #ShareFS
  • Věda a technologie

Komentáře • 403

  • @TheViedocrasher
    @TheViedocrasher Před rokem +145

    Couple tips. Stagger your cables when taping them to fish tapes and tape a cone shape up to the fish tape itself, makes it a way smoother pulling experience. Invest in some drag line. 😂

    • @impaleds
      @impaleds Před rokem +3

      Was reacting the same way as you, it could also be other factors to staggering, but nice to make it as routine to both secure the cables properly to the fishing rod end, normaly i dont trust alone, like to cut off the sheating and make a small knot also with 2 pairs.

    • @josephhughes2784
      @josephhughes2784 Před rokem +4

      Don't forget to rub on the dawn soap on the taped cords. You will never have a cord snag in a tight spot.

    • @mckenziesmall6275
      @mckenziesmall6275 Před rokem +1

      It was on purpose, just to elicit a response/post.

    • @jayh8940
      @jayh8940 Před rokem +3

      you can cut the tip/end of the cable on an angle along with the staggering of the cables and it'll naturally cause the cone shape and pull easily up the wall without getting snagged on anything

  • @jasonmc7031
    @jasonmc7031 Před rokem +48

    Great video of your install.
    If you haven’t already, I’d also recommend creating a MAC filter on any switch port that has a cable going to the outside of the house.
    If by weird chance someone does get to your outside camera and hooks up to the Cat6 going into it, they have open access to your home network. With a MAC filter and adding only your MAC address of your UniFi camera, you’ll eliminate that possibility.

    • @mshuman
      @mshuman Před 11 měsíci +5

      Couldn't they just check what MAC address the camera uses and emulate it?

    • @Platoface
      @Platoface Před 7 měsíci +5

      Just turn on port isolation. I have that turned on for all my cameras and put them on their own VLAN. Then firewall rules so that only the NVR is on the default network.

  • @CBL138
    @CBL138 Před rokem +4

    Pull strings work great when having to pull multiple cables through the same hole. I always leave an extra string in after the job is done just in case I have do another pull in the future.

  • @ucres1
    @ucres1 Před rokem +60

    Those cardboards "blocking the soffit" are actually your ventilation baffles. You need these to direct the air upwards from the soffits rather flowing through the attic, causing havoc to the spray in insulation and reducing the insulation near the soffits.

  • @allisterdavidson9805
    @allisterdavidson9805 Před rokem +21

    7:10 - top tip....'taper' your cable ends so theres a more smoother transition when pulling up multiple cables. It avoids snagging in the wall on anything and the hole at the top.

    • @SPXLabs
      @SPXLabs  Před rokem +4

      Next time

    • @robc5278
      @robc5278 Před rokem +3

      Definitely taper or stagger (the term we use) the cables like Allister suggests but what I also do is cut all my cable ends on an angle which makes a nice smooth head when you stagger the cables.

  • @jankypox
    @jankypox Před rokem +3

    Seriously good video on this with some great tips. Short, simple and to the point! Also some A+++ tips and tricks from the community in this comment section too. Great job all around!

  • @val0228
    @val0228 Před rokem +1

    Thank you for showing the drywall clean up. So satisfying 😌
    Great video 👍

    • @SPXLabs
      @SPXLabs  Před rokem +1

      There is always that one person that loves it. I was thinking of you!

  • @AceBoy2099
    @AceBoy2099 Před rokem +10

    Alternate way of running the cables in your walls. Get a spool of string and run it, maybe 2, with the first cable then just tape new wires and pull string through, could also leave a string in wall for future pulls.

  • @aschmitt89
    @aschmitt89 Před rokem +13

    The Excess Cable you "Cut Back" should've been pushed back into the wall as a "Service Loop" so if you ever needed to move the wall plate in the future, you could. All in all, great work!

    • @SPXLabs
      @SPXLabs  Před rokem

      I did leave enough not sure if your confusing two different moments or not

    • @SuperSpecies
      @SuperSpecies Před rokem +3

      @@SPXLabs It wasn't long enough to be considered a service loop.

  • @korgaun
    @korgaun Před rokem +11

    Next time pull that slack up in the attic as a safety loop and attach to the support beam for future issues. Either side might go bad or damaged so you always want to leave slack. As for future pulls if you want to pull multiple lines there are two methods so it doesn't get knotted while pulling. You can wrap it around the cat6 spool and bring a ladder in to allow it to easily spool out or you can tape around 5-6 feet to keep it clean. Either will work.

  • @mikebutton5174
    @mikebutton5174 Před rokem +55

    Several improvements on your technique. 1) Any penetrations from your heated space into the attic need to be calked to block air leakage The air leakage can cause significant cold spots in your wall and possible condensation in the wall during the heating season. 2) Label your cables before pulling them so you can identify each run 3) At the very least, wire map each run to validate the runs 4) label you r wall jack and your server patch panel

  • @mrmotofy
    @mrmotofy Před rokem +2

    Tell your wife HI from all of us. We do enjoy seeing the amazing helpful wives that make our lives so much easier.

  • @mikel9567
    @mikel9567 Před rokem +38

    Some things I noticed and have probably already been mentioned. Those cardboard barriers are critical. They are soffit vent deflectors and the protect your soffit vents form being covered with insulation. You need to go up there and make sure your vents are clear. it isn't necessary to install new ones if you have missing ones as long as you aren't going to be adding insulation. Second, use a stud finder to locate the studs. Much more accurate. It's your house so not that important, but if you were doing this at a friends house or a customers house, get a small shop vac. Use the shop vac next to your drywall saw when cutting to keep the amount of debris on the floor minimal. Use a reel to pull the tape, if you don't have one, figure 8 the cable on the floor before pulling. It will pull much easier and you won't damage the cable or the wall. Caulk all penetrations into attic or that lead to the outside. Use the appropriate caulk. Typically, fire code requires a fire rated caulk to be used if you are going through any fire barriers as well, so keep that in mind. Use bushings when pulling through an exterior wall or soffit. It will protect your cable.

  • @eduardocavazos1704
    @eduardocavazos1704 Před 10 měsíci +1

    Beautiful work. Great video.

  • @juansaydeflores890
    @juansaydeflores890 Před rokem +12

    make sure you use plenum rated cable in the attic... also use a network tester to test for straight through continuity and any errors on the line.

    • @etekberg
      @etekberg Před 8 měsíci +4

      I don't see a need for plenum rated cable since none of it was run in a plenum. Attics in houses are normally not plenums, and you can see he has typical supply and return ducts.

  • @gasoares85
    @gasoares85 Před rokem

    Great video and what a beautiful house you have. Congrats!

  • @ikke656
    @ikke656 Před rokem +1

    18:16 We also sometimes have problems with RJ-45 plugs, I found out that some plugs are only compatible with stranded wire.
    And most often we use solid wire for fixed connections like in walls.

  • @ShinyTechThings
    @ShinyTechThings Před rokem +11

    You can use a hard drive magnet on both sides of Sheetrock to fish a line through. Just watch your fingers when the magnets make contact.

    • @mrmotofy
      @mrmotofy Před rokem

      The magnepull makes life way easier

  • @Platoface
    @Platoface Před 7 měsíci

    I’m on my 2nd roll of 1k foot of 6a. Fun winter project. I have 13 cameras and the 4 drive NVR. Also 2 of the outdoor LED motion lights. I’ll be hanging more of them as I really do like them.

    • @SPXLabs
      @SPXLabs  Před 7 měsíci

      haha wow! nice. Doing this stuff during winter is definitely a fun project.

  • @ningli8614
    @ningli8614 Před rokem +2

    thanks for the recommendation.😄

  • @warthogA10
    @warthogA10 Před rokem +21

    Always run a pull string with your cables.
    This way of you ever need to run a new cable, simply tie into the pull string, making sure to run a new pull string with the new cable.
    I typically run a string down with each drops as well, for any future need

    • @SullySupa
      @SullySupa Před 4 měsíci +1

      This comment is gold!!!

    • @ford9501
      @ford9501 Před 22 dny +1

      Also helps to tape a label to the string with the length of the run. Can help order the right length if you need to run a pre-terminated cable in the future, like a fiber patch in the future.

  • @foxpopuli6982
    @foxpopuli6982 Před rokem +3

    I enjoy this kind of content. Subscribed 👍

  • @garybowers5724
    @garybowers5724 Před rokem +3

    I did the same (but in the UK) running cat6a between 110yr old walls :P the result is great though as I got a HDAnywhere 8x6 matrix and centralised by streaming devices and satelite box in my rack - this runs 4K HDR over Cat6a to the TV's
    I've also ran some setereo audio baluns over them also to feed audio around it's great!!

    • @SPXLabs
      @SPXLabs  Před rokem +2

      Oh nice. I should probably look into HDMI over ethernet. What equipment are you using to accomplish your setup? I'm in the early planning stages of how I want to get audio and video to and from the TV and am looking for any recommendations or just general insight to existing setups.

  • @kotgc7987
    @kotgc7987 Před rokem +2

    7:21 electrician's tape around the end tip of the Ethernet cables and the pull through, smoothens the pull through.
    10:52: ceiling speakers FTW.

  • @robertkinnan3478
    @robertkinnan3478 Před rokem +3

    Many times the current length of the cable is written on it. Basically you could have read that off your first cable without pulling it out.

  • @austinsdarkhalo
    @austinsdarkhalo Před rokem +1

    Cheers to a fellow Subi owner!
    Great video, gave me a few ideas for my house. Looks like you're based in TX (based on build styles/ internal structures). Adding some extra insulation up in the attic might help your AC bill in the summer time! Doesn't look very thick in the videos but the climate for TX is around Zone 2/3 so roughly R30-R60 recommended. Cellulose is a crazy cheap option and pretty easy to install. But you'll want any and all cables ran before you do that, so you don't need to disturb it. Just my thoughts, because electricity is expensive 🤣

    • @SPXLabs
      @SPXLabs  Před rokem +1

      Big fan of the WRX and of course STI.
      Thanks, I am in Huntsville, Alabama. I don't remember the R value for the insulation but there is about 14 inches except for the areas I disturbed.

  • @ShinyTechThings
    @ShinyTechThings Před rokem +4

    Drill up and use a glow necklace through the hole to make a reference point. Then putty to patch and paint.

    • @rawniew
      @rawniew Před rokem +3

      this guy cables

    • @rawniew
      @rawniew Před rokem +1

      also instead of pulling that reference first run back all the way just add extra pull length the wall height to get the other 3 up

    • @mrmotofy
      @mrmotofy Před rokem +1

      Use a magnespot, has a little sharp in with a bunch of magnets attached. Then a locater one uses from other side. Can locate within 2" or so. No holes to patch, paint to touch up etc...and they're cheap

  • @ptessier73
    @ptessier73 Před rokem +21

    CAT6A, man I feel for you. After running many parts of my house with CAT6 where I couldn't feel my fingers in the end, with CAT6A being a thicker cable, you were in a world of pain lol. Seriously doing SOLID cable termination is a pain compared to stranded but there is no choice when you are putting anything in the walls as per fire code at least here in Canada. Really good to give yourself a lot more cable than you need on each end; I was glad I did. When you terminate a cable it doesn't always work out, I had to redo that 2 to 4 times at times on 1 end just to have a proper termination.

    • @SPXLabs
      @SPXLabs  Před rokem +10

      Bruh, I had an hour and 58 minutes of video, mostly terminating. My hands and fingers had so many cuts from nails and splintered wood, so holding those tiny wires to slide them into the RJ45 connector was brutal. And I only did it 6 times. The reason the video just seems to jump from TV to 2 outdoor runs is because I was just so over lugging the camera up and down the ladder to the attic lol. Most of the video was uninteresting too, I think. Just pulling and pushing cable around.

    • @user-nh3gu1ge3d
      @user-nh3gu1ge3d Před rokem +8

      And as an IT contractor, Cat6A was a terrible choice anyway. I know he got it for free so I guess in that regard it makes sense but from a choice standpoint, a 4k UHD stream is around 25 Mbps. Most smart TVs only have a 100 Mbps NIC anyway. Cat5e is already 10x overkill for that. Then stepping up to Cat6, you can get gigabit, and even 10 gigabit up for 40 meters, which would be 100x overkill. Then stepping up again to A would simply give a longer range, 100 meters, on that pointless 10 Gbps. So many people online say to "future proof" and buy the biggest, most expensive cable, but that's really dumb. 5e is fine for 99% of end user applications, 6 is overkill. 6a is just double overkill. And when you consider that 5e has been around for over 20 years, and is STILL overkill for most end user things, if puts into perspective just how useless your "overkill" solution really is. Again, if I'm getting the cable for free I'll use it, but there's absolutely zero reason to buy it. It just hurts your wallet and is a harder job for the exact same performance.

    • @SPXLabs
      @SPXLabs  Před rokem +7

      Yup all of this. Which none of which I talked about or mentioned. Just got some free cable and installed it.

    • @ptessier73
      @ptessier73 Před rokem +3

      @@user-nh3gu1ge3d I went with CAT6 in my home because it wasn't that much more expensive over CAT5E and that way my house if secured for 10GB in the future if I want to. You are right in saying it is overkill maybe for the next 5 to 10 years until you start getting devices capable of 8K. But I mean that will take a hell of a lot of time before we get there. Do you need 10GB right now in homes? Probably not, it is too expensive anyway. I think the next logical step is 2.5gb for homes and that would be good for people who need it. But the problem is that there are not many products out there for 2.5Gb. I haven't seen a single 24 ports 2.5gb switch yet.
      As an IT contractor, you most have installed plenty of cable right? I have a question for you. As per code, running wires in walls require PLENUM cable. So I'm using CAT6 plenum. But I was often faced with issues doing my termination, in preparing the wires, it would happen once in a while one of the wires would break!! Is that something common?

    • @user-nh3gu1ge3d
      @user-nh3gu1ge3d Před rokem +2

      @@ptessier73 I actually ran Cat6 in my house as well, but for reasons similar to yours. It's definitely overkill. Even 5e is overkill for 99% of end user devices. Your smart devices, cameras, etc. are all 100 Mbps max so even cat5 would be fine. But I typically have 10 boxes of cable on hand and, before CV screwed everything up, the difference in price was only like 25 bucks or so (around 125 vs 150 bucks for 1k ft). I also felt a little better about using a thicker gauge wire for POE, though I'm sure there's no real difference. 6 is also more tightly wound so better for cross talk and things like that, but you shouldn't really have that issue anyway. If you're laying your wiring on top of florescent lights, then that's an install issue anyway.
      And even 8k streams will only use about 100 Mbps, so again, there's just no reason for it most of the time. 10 gig is good for mass devices, infrastructure like switches, servers that serve multiple/many clients, huge data transfers like video editing. The bandwidth required for even the highest definition streaming is minimal, audio is nothing, gaming is nothing, etc. Basically the most common thing that needs gig to 10 gig is video editing and huge file transfers, like if you are moving around 100 gig files, stuff like that. Even moving 100 gigs on a cat5e will "only" take a minute and a half so not that bad. When you go 10 gig then you need MASSIVE infra spending because you've got to upgrade every switch in the chain, every NIC, every device. If ANY device is slow then it will bottleneck the whole thing. Even your standard HDD is only around 150 MB/s so that can't even keep up with a 10 gig cable. That can barely saturate a 1 gig line. So you'll have to use solid state storage and if you're working with 100 gig files, that means you need tons and tons of space, like 50-100 TB of solid state hard drives, and you need redundancy, etc. you're talking about tens of thousands of dollars per server like that, thousands on switching, etc. The most that a "pro-sumer" like me would do at home would be a direct connect from a cheaper server to a PC, with a small, single digit 10 gig switch, and just let the HDD RAID be the bottleneck. Very fast but not "large enterprise" fast.
      As to your question about the plenum, almost all the cable I run is "riser" not plenum. Plenum costs way more and is only used for plenum spaces, to put it simply, air circulation. You don't have to use plenum in walls or ceilings or pretty much anywhere UNLESS it's inside an air duct or certain ceiling air spaces (like if you have drop ceilings that have air supply or returns that will suck in the air from that space). Long story short, it's again one of those "almost never" things. I know the Safety Sally's will come out of the woodwork and tell me how wrong I am and blah blah blah but I'm telling you. I worked in a data center before and we used many vendors and whenever we got quoted runs, it was always riser cable. You had to specifically ask for plenum and then it would be vastly more expensive. YMMV.
      It's the same cable, it's just the sheathing is slightly less toxic when it burns. But guess what, smoke is toxic 😆! Whatever you're burning, if you're breathing that in, you're in for a bad time. I get it if it's in an air vent or whatever but like I said, in most cases it doesn't make a noticeable difference. You may have company or insurance requirements though, they may require you to run plenum in the ceilings for liability purposes but we never did. Maybe we are a bit too "cowboy", I dunno.
      And finally, to answer your question about the wire breaking, it sounds like you scored the sheathing a bit too deep. If you cut around the sheathing and dig too deep, it cuts into the copper wire and absolutely, it will snap off. Hope that answers your question. Whew!

  • @nigelmoullin452
    @nigelmoullin452 Před rokem +5

    Nice video, just a few points -
    You levelled the low level box to the top of the existing plate so when you fitted the plate it looks like it is slightly higher.
    I would not pull the cable off the side of the drum, either use a cable dispenser or even a broom handle through the drum.
    Do you not number the outlets

    • @SPXLabs
      @SPXLabs  Před rokem

      Yeah I didn’t think of it till way to late.
      They are labeled in the other end.

  • @Airborn14
    @Airborn14 Před rokem

    Great video!

  • @keystroke13
    @keystroke13 Před rokem +22

    Consider getting a bump cap if you're worried about hitting your head on roofing nails. Cheaper alternative to quick care or tetanus shots.

    • @SPXLabs
      @SPXLabs  Před rokem +2

      Next time!

    • @TXCowboy35
      @TXCowboy35 Před rokem

      that protects your head but what about your back?

    • @chadhowell1328
      @chadhowell1328 Před rokem

      You won’t get tetanus from it, just scratches and cuts. Tetanus comes from bacteria found on the ground and not rust like many think. Bump caps are worth it though in keeping your noggin scratch free

  • @AndreMiller-RED
    @AndreMiller-RED Před rokem +1

    Idk if anyone mention this but the cables have measurement markings on it to help with that issue. So in your case after you ran the first one you can look at the measurement and go off that reading.

    • @SPXLabs
      @SPXLabs  Před rokem +1

      I actually never noticed that’s awesome

  • @mrmotofy
    @mrmotofy Před rokem +1

    Yep stagger your cables 2-3" at least or use a cable pulling sock, pulling sleave or whatever they're called. The wire mesh that expands over the end of the cable then collapses as it is pulled tight.

    • @johnolsen3341
      @johnolsen3341 Před rokem +1

      It's called a kellum grip

    • @mrmotofy
      @mrmotofy Před rokem +1

      @@johnolsen3341 That may be ONE name for it

  • @THECHEESELORD69
    @THECHEESELORD69 Před 5 měsíci +1

    Now that is on sexy spool of cable!

  • @erickonassis6310
    @erickonassis6310 Před 2 měsíci +1

    Cant wait to do this to my home, going with aruba equipment..

  • @christopherortiz8713
    @christopherortiz8713 Před rokem +1

    Great video.. need to run a few for the house as well. What kind of camera did you use? Also what kinda switch do you recommend for your network closet?

    • @SPXLabs
      @SPXLabs  Před rokem +3

      It was a Ubiquiti UVC G3 Pro. Well for my network closet it's all ubiquiti everything. Because it's an ecosystem and everything works well. For other people, that is a super loaded question, because I have no idea what your expectations are, your goals, wants, needs, and desires. Are you technical, and even if so are you more of a lazy admin who wants to set it and forget it or are you a I must control every facet of each piece of tech admin.

  • @chrisasgari5451
    @chrisasgari5451 Před rokem

    I love it thanks.

  • @holeefook3149
    @holeefook3149 Před 10 měsíci +1

    I'm thinking about just using the coax the previous owner has in every room (from Dish and cable) with Moca.. just switched to fiber (waiting in line for home install)..

    • @SPXLabs
      @SPXLabs  Před 10 měsíci +1

      Moca is a great simple easy thing to do. Most of the time I just recommend that to folks over running wire because it's cost effective and most people don't watch cable tv anyway.

  • @libaaxalee
    @libaaxalee Před rokem +2

    Great job, now that is what I need to do on my home networking. Hope you were in my city in KC to give me an estimate :)

  • @ShinyTechThings
    @ShinyTechThings Před rokem +1

    Do 4 speakers in the ceiling for surround sound. That's what I have and it's awesome!

    • @BigWill3855
      @BigWill3855 Před rokem

      Can’t go wrong with an 5.1.4 Dolby Atmos setup

  • @GotWire
    @GotWire Před rokem +3

    love it man! Besides going in the attic I love running cable! and I thought that was funny your wife dint want to be in the video 🤣

    • @ptessier73
      @ptessier73 Před rokem

      🤣😂Indeed that was hilarious. And the look he gave her.. LMAO.

    • @SPXLabs
      @SPXLabs  Před rokem +3

      I love everything about running cable, except for actually running cable lol. She may or may not have been partially nude.

  • @Espiritiv
    @Espiritiv Před rokem +3

    The cardboard stuff is actually to keep your blown in insulation from blowing into the soffits and also direct air up along roof. PS what is the name of those push rods? Got a link you can add to description?

    • @SPXLabs
      @SPXLabs  Před rokem +1

      These are the rods I bought, amzn.to/3CwtjTN

  • @bbateman09
    @bbateman09 Před 2 měsíci +1

    In my experience passthrough connectors are not the best. 2 piece connectors use a passthrough "loading bar" that's cut flush then inserted inside the connector. This ensures no wires protrude out of the connector end causing unreliable connections. The best connectors have a 3rd piece to separate the 4 twisted pairs and maintains the twist right up against the termination points inside the connector. It's more steps to terminate but is the best possible connection with the least amount of signal loss. Some high end AV equipment like certain control systems specifically state to never use passthrough connectors.

  • @JBLewis
    @JBLewis Před rokem

    Props on the SubieFest T-Shirt

    • @SPXLabs
      @SPXLabs  Před rokem

      Pretty cool to get down to Florida and be apart if it

  • @deathblade909
    @deathblade909 Před rokem +1

    i have been wanting to do this but with access points from my main ONT

  • @32bitDK
    @32bitDK Před rokem +2

    Good video .

  • @fps_purple9556
    @fps_purple9556 Před rokem

    @spx is the insulation on those conductors for the white striped pairs actually striped or solid white?

    • @SPXLabs
      @SPXLabs  Před rokem +1

      Yes, all the stripes exist for orange, green, blue, and brown. I'm fairly color impaired and in real life they are very vibrant and visible.

  • @everss02
    @everss02 Před rokem

    For the outlet an old work box, outlet and a few feet of romex is all u need, easy and way cheaper and cleaner.

  • @najjamitat9517
    @najjamitat9517 Před 4 měsíci

    @ SPX Labs' couldn't you have just used a pull string to run the other 3 after you found out how long they needed to be?

  • @DuceFace
    @DuceFace Před rokem +2

    My man actually pulled up a tray24k stream on the TV. What a legend

    • @SPXLabs
      @SPXLabs  Před rokem +1

      I Watch that milk drinker all the time, him and all his team killing shenanigans.

  • @bryguy2724
    @bryguy2724 Před rokem +1

    Don't spools of cable usually have distance markings on them so you can just use that instead of pulling it back out to measure it?

  • @Daltoncom
    @Daltoncom Před rokem +1

    I have had surprising success with cheap iSelek brand pass thru connectors from Amazon. I install Unifi cameras professionally.

    • @SPXLabs
      @SPXLabs  Před rokem +1

      I'll give these a try when I run out of connectors. Thanks for the heads up!

  • @ge2719
    @ge2719 Před rokem +1

    Any idea how you'd do this in a house with two floors? Getting cable down to the bottom floor from the loft seems like only way would be to pull away the skirting, and cut holes in the walls and even then you've got to get the line down the floor joist gap and In behind the plasterboard in the floor below.

    • @SPXLabs
      @SPXLabs  Před rokem +2

      There are a ton of dependencies, generally the easiest less painstaking way to go between floors is to just run the cables along the exterior of the house and drill through the house exterior and interior walls.

  • @ZRubidium
    @ZRubidium Před rokem +2

    Curious Question, I've done a couple of Ubiquiti installs for friends and family member, and I bought a 12-port (punch-down) Patch Panel and ran 12 cables (all plenum rated) from the "wiring closet" to the attic, terminated it, then built cables to go from the patch panel to the end device. Each build I did we never had the idea for more than 2 devices, but the idea of future additions was appealing. Why not just add one now, I know that creates another point of failure and complexity, but easier to "add" devices.

    • @SPXLabs
      @SPXLabs  Před rokem

      I don’t understand? I ran 4 cables behind the tv.

    • @ZRubidium
      @ZRubidium Před rokem +1

      @@SPXLabs did you run the cables from the office, up to the attic, down to the room? Then also ran more wire for camera's, the curious part would be why not add a patch panel to the attic, so you don't have to keep doing more runs from the wiring closet to the attic in the future.

    • @SPXLabs
      @SPXLabs  Před rokem +3

      I ran a bunch of cables yeah. I have never thought about that. That’s way too smart for me lol. Hmm. Good idea though for real

  • @molek5823
    @molek5823 Před 2 měsíci

    These Transmission have very sick engines, proof somethings wrong with them!!!!

  • @mpitogo1978
    @mpitogo1978 Před rokem

    Wow, big undertaking is it worth the effort? So my house was wired with cat 5e. I'm running a 2.5G backbone 1 core switch and two Asus ET12 using the 2.5g wired for backhaul priority with 2 other 1G dumb switches for edge devices and it seems to be ok with it. I found some ports just needed re-termination on the jack and all seems to work after. I wonder what the cost benefit is? I'm looking at the stats of the 2.5ge and it seems to be ok, on my 2.5G PC shows no Discards or Errors. Perhaps if I move to 10G then yes only so much s/n ratio bandwidth on cat 5e.

    • @SPXLabs
      @SPXLabs  Před rokem +1

      cat5e will do 2.5/5G up to 100 meters, so you probably don't need to upgrade the backbone at all. I have cat6a run all over the house (mostly unnecessarily) but in my office I must have it so I can do 10Gb (1GBps) because of all the youtube videos I make and am constantly saving on my home server. If you do ever move to 10G then cat6a will be most appropriate, especially for long cable runs.

  • @ICgasm
    @ICgasm Před rokem

    Pass through plugs may require you to cut closer to the plug, since the crimper doesn't fully trim the conductors off.

    • @SPXLabs
      @SPXLabs  Před rokem

      I’ve read about that but haven’t experienced it until maybe now.

    • @mrmotofy
      @mrmotofy Před rokem

      I've started using pass through. Use a regular crimper, pull wires Trim with a flush diagonal cutter. Pull wires back slightly so don't protrude then crimp. No extra tools to buy or carry

  • @Bad.Skunky
    @Bad.Skunky Před rokem

    Good stuff man! Hey, what kind of camera did you use for this video --if you don't mind me asking?

  • @Platoface
    @Platoface Před 7 měsíci

    I recommend the Sonos Arc. FYI, DO NOT hardwire in any Sonos speakers as it can create a loop in your network. I found out the hard way.

    • @SPXLabs
      @SPXLabs  Před 7 měsíci

      Hey I was just looking at that today. I’ll keep that in mind. I still do not know what I’m going to do to this day

  • @mrmotofy
    @mrmotofy Před rokem +10

    FYI, TECHNICALLY modern Fire Code requires those holes in the wall plates(top/bottom wall horizontal 2x4/6) need to be sealed by a foam/fire caulk. Many inspectors will let you slide by stuffing some fiberglass in there. Don't want smoke traveling between floors in a fire. It's certainly not a BAD idea and it's quick and easy

    • @prevaloir5362
      @prevaloir5362 Před 9 měsíci +1

      Who follows that?

    • @Fireguy473
      @Fireguy473 Před 6 měsíci +1

      that ONLY applies to firewalls/barriers, and you only need to fill it with material that matches the rating of the wall that was penetrated. Unless any of the wood was treated with fire resistant coating (which most residential construction is not) there is no fire rating, ergo no fire resistant caulk is needed. The code you may be referring to isn't really about smoke, its about maintaining the fire wall's rating to prevent heat and fire from spreading, also the code you are referring to is for commercial establishments and apartment complexes. It is still recommended he fill in the remaining space of that hole with an insulation foam to prevent a break in the insulation. Also at no point do we let anyone slide by stuffing some insulation in the hole for the reason i mentioned earlier, that is a violation 100% of the time, no other inspector, including myself, that I know of ever let that slide

    • @mrmotofy
      @mrmotofy Před 6 měsíci

      @@Fireguy473 I had a job for 3yrs walking around with inspectors. I don't know where you are but it's NOT only a firewall. It was any floor penetration. The firewalls had to be firecaulk

    • @silverbackag9790
      @silverbackag9790 Před měsícem

      Used to be common practice to stuff mineral wool in them. Maybe not in all regions.

  • @godslayer1415
    @godslayer1415 Před rokem

    LOL CAT6a - did that 15 years ago. Good Job - obsolete before it's even installed.

    • @SPXLabs
      @SPXLabs  Před rokem

      Dang 15 years ago I was in high school. That's pretty sweet that you were able to install it so long ago. Back then we had just transitioned from telephone lines to ethernet, I believe plain old cat5. Anyway, it's more than good enough for me. Cheers!

  • @robertharker
    @robertharker Před 4 měsíci

    Why did you not put the cable spool on a pipe or broom handle suspended between two chairs to unspool the cable?

    • @SPXLabs
      @SPXLabs  Před 4 měsíci +1

      Man I never would have thought of anything like that even if I had all of those things sitting in front of me

  • @schmat73
    @schmat73 Před rokem +1

    Can you add the link for the power extension boxes? Maybe you did and I’m just not seeing it.

    • @SPXLabs
      @SPXLabs  Před rokem +2

      I missed it. amzn.to/3NN5BaC

  • @caskervold1
    @caskervold1 Před rokem +1

    Is your preference for new home CAT6A shielded or unshielded ?
    Thank you

    • @SPXLabs
      @SPXLabs  Před rokem +1

      It depends on size and length of the cable runs. Unshielded cat6 is fine most of the time but if you can afford it just go for Cat6a. shielding is pointless in a non scientific environment

  • @simezra
    @simezra Před rokem

    Headlamp used? i liked the flood beam

    • @SPXLabs
      @SPXLabs  Před rokem

      It’s klien headlamp. Couldn’t tell you anything else about it except it charges via USB C

  • @Ralph-ha
    @Ralph-ha Před 3 dny

    guys, i need help..what's the job description to run ethernet cables or school carrier?

  • @rossrobinson7943
    @rossrobinson7943 Před rokem +3

    So couldn't you have used the foot numbering marking on the cable to know how long to cut the cables #2-4?
    Or does this new stuff not have the sequential numbering?
    Life hack: When you get a new spool write down the foot number on the start of the spool. Then you know how much cable you have left.
    2nd hack: When you pulled the first cable, also attach a pull string for the follow on cables. Of if you think you might add a cable in the future, leave a pull string with the cable. Then you don't need to fish in the future.
    3rd: When pulling a bunch a cables make a cone with tape to help it to snag less. + You can stagger the start of the cables to not have a big wad at the front.

  • @bdfresh973
    @bdfresh973 Před rokem

    On the exterior camera, how did you mount the camera? Is it mounted into the 2x4 for the soffit? or screwed into the metal? Any insight on that process would be appreciated. Thank you in advance.

    • @SPXLabs
      @SPXLabs  Před rokem +1

      There is a piece of wood that extends out that I screwed the mount into. I have other cameras that are screwed into the soffit and have been fine. Over the last couple years the driveway camera has survived several thunderstorms with winds of 50mph or more and it’s screwed into the soffit

    • @bdfresh973
      @bdfresh973 Před rokem

      @@SPXLabs therefore, you probably were able to get at least two of the three screws into the wood 2x4, correct? *Which I believe would securely fasten the camera--did you use the third screw into the sheet metal or leave it out?

    • @SPXLabs
      @SPXLabs  Před rokem

      I’m not aware of a third screw being provided by Ubiquiti. Just using two. Got hit by tornado winds last night and all cameras survived

  • @taht_dg
    @taht_dg Před rokem

    Would make a bet that the reason the cable ends you mentioned weren't working for you might of been the quality of the little copper bits that penetrate into the wires in the cable, noting that you were using a bit thicker of a cable that I assume had beefier rubber on the wires inside.

    • @SPXLabs
      @SPXLabs  Před rokem

      That’s definitely a possibility.

  • @a1r3x
    @a1r3x Před rokem

    What kind of in wall speakers would you get?

    • @SPXLabs
      @SPXLabs  Před rokem

      I haven’t purchased any yet

  • @jimholloway1785
    @jimholloway1785 Před rokem +1

    Do you have the links for the Klein 6a passthrough connectors? Were the Klein passthrough connectors Cat 6 or Cat 6A?

    • @SPXLabs
      @SPXLabs  Před rokem +2

      I don’t think they designate between the two. But I use these and they work fine.
      amzn.to/3zPES7v

    • @jimholloway1785
      @jimholloway1785 Před rokem +1

      @@SPXLabs Thankyou

  • @user-xp8qz1cc8z
    @user-xp8qz1cc8z Před 6 měsíci

    Hope to copy this exactly. Why 4 data ports behind TV? Nice job!

    • @SPXLabs
      @SPXLabs  Před 6 měsíci +1

      Because they gave me 1000 feet of cable and well I’m already doing the work may as well run more. Also I like the idea of having dedicated connections back to the server closet. I’m only using 2 ports currently.

  • @davidmann3536
    @davidmann3536 Před 4 měsíci

    Wish you had demonstrated attaching the cable to the connector.

    • @SPXLabs
      @SPXLabs  Před 4 měsíci

      On the plus side there are some channels out there that show how extremely well. And probably more entertaining than me too

  • @TacticalMoistTowelette

    Thanks for the video. I noticed a few things from the video. Are you a Trey24k fan? Do you play Tarkov?

    • @SPXLabs
      @SPXLabs  Před rokem

      Yeah I watch that milk drinker anytime I get a chance. I do play Tarkov when I have time.

  • @Jack_Frozt
    @Jack_Frozt Před 10 měsíci +1

    i love overkill

  • @Shia-Isna-Asheri
    @Shia-Isna-Asheri Před měsícem

    Hi, I am new to all this so please tell me why do you run 4 cables when you can just have one RJ45 or Fiber cable and add a Network switch? Am I missing something?

    • @SPXLabs
      @SPXLabs  Před měsícem

      I explained it in the video

  • @lancerudy9934
    @lancerudy9934 Před rokem

    Did you put numbers on the cable?

  • @bjornjoseph
    @bjornjoseph Před rokem

    house has 5e for telephone and i ran about 8 cat6 lines... eventually id have to redo the 5e when 2.5gb comes standard

    • @SPXLabs
      @SPXLabs  Před rokem

      Man that’s really cool you had 5e. I would have loved to have Ethernet everywhere I lived

  • @25566
    @25566 Před 10 měsíci +1

    I would have installed the network ports behind the furniture, tv only needs one but your consoles, media players, etc might need the other ones. So that way only one cable goes up the side of the wall

    • @SPXLabs
      @SPXLabs  Před 10 měsíci

      That's a good idea actually. So far, no consoles only Apple TV which is mounted behind the tv. a Receiver will go in the network closet in the future.

    • @andrewoakeshott8931
      @andrewoakeshott8931 Před 5 měsíci

      That is what I did When I did my place, 4 to each TV location, One at the TV and 3 at rhe Bottom

  • @iixnullxii1
    @iixnullxii1 Před 2 měsíci

    Man I wish I could wire my 50s house but I just don't have the skill to do drops. I've resorted to wiring around the trim of the house and routing it in through the outer walls of select rooms.

    • @SPXLabs
      @SPXLabs  Před 2 měsíci

      That’s honestly not a terrible idea. It’s either that or tear up dry wall, drill holes through studs, and then patch and paint everything back uo

  • @hariharaans
    @hariharaans Před rokem

    🔥🔥🔥

  • @electricalservicesmaroc

    hello what is the name of camera you use for filming

  • @ShaamanRyu
    @ShaamanRyu Před rokem

    silly question : what is that orange bracket thing you have that supports the ethernet wall plate?

    • @SPXLabs
      @SPXLabs  Před rokem +1

      Not silly. A single gang mounting bracket.

    • @ShaamanRyu
      @ShaamanRyu Před rokem

      @@SPXLabs is there any specific one you recommend? Or is whatever I find at the local hardware store good enough?

    • @SPXLabs
      @SPXLabs  Před rokem

      amzn.to/3VXDbwX This one

  • @jimbaker4277
    @jimbaker4277 Před rokem

    13:35 3M tape is best in hot and cold work sites.

  • @Gameplayer55055
    @Gameplayer55055 Před rokem +1

    Used cat6 cable mostly for future proofing. Nothing special, but it was a bit tricky to terminate connectors

    • @SPXLabs
      @SPXLabs  Před rokem +2

      Cat6 is perfect for typical home use. Much better than cat5e. You did good.

    • @Gameplayer55055
      @Gameplayer55055 Před rokem +1

      @@SPXLabs used shielded ones, because internet wires were alongside with mains wires

    • @SPXLabs
      @SPXLabs  Před rokem +2

      Probably a good idea. If there is a lot of electrical I’ve hear interference is possible.

    • @mrmotofy
      @mrmotofy Před rokem +2

      @@Gameplayer55055 Many long time experts say yes...shielded is a good theory...in reality...don't worry about it. In a home it's extremely rare to ever be an issue

    • @Gameplayer55055
      @Gameplayer55055 Před rokem

      @@mrmotofy many mains wires scared me and in local stores shielded cables were just a bit more expensive

  • @lupelai8962
    @lupelai8962 Před 8 měsíci

    I have an ethernet on the room above my home office. Is it possible to split that connection and bring that cable down? I have access to the attic right above my home office. The room with the ethernet connection is slightly to the right. I hate Wifi extenders!!! They crash constantly and keep losing my remote desktop connection to my work computer

    • @SPXLabs
      @SPXLabs  Před 8 měsíci

      It's better and easier to just run a new cable from inside the house to the outside the house and back inside. Otherwise consider paying a professional to do it right. Otherwise you will just have headaches from the shortcut you are asking about.
      Alternatively if you have COAX in your home, you can buy a pair of these and get internet to another room with it. amzn.to/45Xup87

  • @ashegheaty
    @ashegheaty Před 7 měsíci

    Is it possible to connect my internet modem to my smart tv with wire in an approximately 30 meter distance ? If yes what cable is the best ? Thank you .

    • @SPXLabs
      @SPXLabs  Před 7 měsíci +1

      Assuming your smart tv has an Ethernet port, yes it’s possible. A simple Ethernet CAT5e cable should be more than perfect for the job.

    • @ashegheaty
      @ashegheaty Před 7 měsíci

      ​@@SPXLabsthanks alot

  • @tlwebdesign1
    @tlwebdesign1 Před rokem +1

    ℹ just had fiber optic cable installed any suggestions on getting my house wired?

    • @SPXLabs
      @SPXLabs  Před rokem

      Like by a professional?

    • @mrmotofy
      @mrmotofy Před rokem +1

      I just made a vid about the basics of home networking and there's lots of info in there as well as more in the pinned comment

  • @ethanb9632
    @ethanb9632 Před rokem +1

    It was the Trey24k Tarkov stream for me

  • @EvanIIRC
    @EvanIIRC Před rokem

    Nice. Also let me know when you're done with that 42U rack. I'll take it off your hands free of charge :)

    • @SPXLabs
      @SPXLabs  Před rokem

      I may already be done with it…. It’s too big to fit anywhere

    • @EvanIIRC
      @EvanIIRC Před rokem

      @@SPXLabs that's big sad

  • @jfkastner
    @jfkastner Před rokem

    Well done! Don't drill too many holes into your house though

  • @kurlis
    @kurlis Před rokem

    You know it doesn't matter the A or B standard as long as you match your colors on the other side you're good

  • @JasonsLabVideos
    @JasonsLabVideos Před rokem

    Awesome video my friend !! I just did this for my theatre room :) BTW give me your Ryobi Leaf blower !! I need that !

    • @SPXLabs
      @SPXLabs  Před rokem +2

      Hell yeah! It will pay off in the long run so I'm glad that I had to opportunity to do this. What do you want me to blow? oh never mind misread that.

    • @JasonsLabVideos
      @JasonsLabVideos Před rokem +1

      @@SPXLabs Made me spit my coffee out, you owe me a new keyboard ! Sending you an Invoice for replacement !

    • @SPXLabs
      @SPXLabs  Před rokem +1

      You have my address!

    • @JasonsLabVideos
      @JasonsLabVideos Před rokem +1

      @@SPXLabs On my way !

  • @ptessier73
    @ptessier73 Před rokem +1

    Out of curiosity, did you build walk ways made of plywood in your attic or are you just being careful not to step on drywall?

    • @SPXLabs
      @SPXLabs  Před rokem +2

      There are some walkways already up there but the vast majority of it, I am just carefully stepping on the existing studs.

    • @JeffGeerling
      @JeffGeerling Před rokem +2

      @@SPXLabs I call that the "calves will be sore for the next week" approach to attic work 😂

    • @SPXLabs
      @SPXLabs  Před rokem +2

      At my age, it’s sore all over.

    • @ptessier73
      @ptessier73 Před rokem

      @@SPXLabs Time to ask your wife for a back rub.

    • @SPXLabs
      @SPXLabs  Před rokem +2

      “Well Jules, the funny thing about my back is that it’s located on my …..”

  • @jfkastner
    @jfkastner Před rokem +6

    BTW when I install cameras I use thinner cheaper CAT5 because normal SOHO security cameras will never ever exceed 100Mbps anyways (mine are limited to 8Mbps video stream via firmware) ... also when you pull 4 cables at once tape them together 'staggered' 1/4 in offset each that'll create something looking like a speertip that's easier to pull though

    • @SPXLabs
      @SPXLabs  Před rokem +1

      Don't exceed 100Mbps yet. lol

    • @jfkastner
      @jfkastner Před rokem +1

      @@SPXLabs one day you can watch ants crawl into your backyard on your 400 megapixel cam ... maybe then you need to upgrade to gigabit but the CAT5 is still good enough

    • @SPXLabs
      @SPXLabs  Před rokem +2

      I want to live in a world where I need 10GbE for my cameras

    • @jfkastner
      @jfkastner Před rokem +2

      @@SPXLabs I installed a 'video wall' for a customer with 10 full HD screens, and we ran about 3 Gbps continuously to feed video through the 10 Gbps LAN

    • @SPXLabs
      @SPXLabs  Před rokem

      That’s it?? Those are rookie numbers. You got to pump it up!

  • @w9gb
    @w9gb Před 3 měsíci

    NOTES: Suggestions from 4 decades of Cable Pulling (Electrical and Low Voltage)
    1.) Drill Holes correct diameter to Pull Maximum # cables (like 4, your TV pull)
    2.) Use Pull Strings for Future Proofing (later cable pulls)
    3.) 500 and 1000 foot spools of Category 6a UTP usually length marks on outer jacket,
    use that feature to determine length of that TV to Patch Panel cable.
    -
    Fire Caulking already mentioned.
    I have watched Cable Crews fired, and one group brought to tears by Fire Inspectors.
    He had investigated a recent fire - lack of fire blocking help spread fire (and he showed them).

  • @chrisdover8014
    @chrisdover8014 Před rokem +1

    The cardboard is to encourage the airflow from you soffit vents to follow the roof to the ridge vent. I need to pick up a roll of that cable for my house.

    • @SPXLabs
      @SPXLabs  Před rokem +1

      Oh neat, I thought it may have been there to keep water from getting in or something stupid lol. Thanks for the details. I got plenty of extra at the moment. Come on by.

    • @mrmotofy
      @mrmotofy Před rokem

      Just holds back insulation from blocking air flow or the insulation from falling down into soffit since it can be 15" thick or so up there

  • @Hemux0
    @Hemux0 Před 9 měsíci

    Nice video... and also shout out to Trey24k! :D haha could it be you are a fan of Tarkov? awesome

    • @SPXLabs
      @SPXLabs  Před 9 měsíci

      Yeah buddy! I play fairly often.

  • @christinakloster9843
    @christinakloster9843 Před rokem

    Not gonna lie I did not care of 6a when I started to use it to run it in my house but I love it and prefer it over 5e

    • @SPXLabs
      @SPXLabs  Před rokem

      The more I use it the more I find how difficult it is to wire up. It’s not hard just a bit more strenuous

  • @fieldy69420
    @fieldy69420 Před rokem +1

    Rj45 ends aren't designed to be used on solid cable. That's why all patch cables are stranded cables.
    You didn't have to pull the cable back out the wall. The cable has footage markings on it.

    • @SuperSpecies
      @SuperSpecies Před rokem +2

      Not true. There are different type of RJ45/8P8C ends for solid and stranded.