HVACR: Refrigeration Service Call (Walk In Refrigerator Not Cooling) Compressor Not Starting/Working

Sdílet
Vložit
  • čas přidán 4. 03. 2022
  • HVACR (Heating, Ventilation, Air Conditioning/Refrigeration) Refrigeration Emergency Service Call (Walk In Refrigerator Not Cooling/Walk In Refrigerator Not Working) Beer Cooler Not Working/Compressor Not Starting/Working/How To Check Compressor/How To Check Run Capacitor/How To Check Start Capacitor/Commercial Refrigeration/Walk In Cooler Troubleshooting
    =================================================
    LINKS TO PURCHASE:
    Veto Pro Pac Tech Pac MC (Compact Tech Pac)
    amzn.to/2ZGttI4
    Fluke 902 FC HVAC True-RMS Clamp Meter
    amzn.to/39wvwiK​​
    Fieldpiece JL3KR4 HVACR Charge Kit (Digital Gauges/Probes)
    amzn.to/3E4W0Fr
    Milwaukee Cut 1 Dipped GLOVES L
    amzn.to/3s8H18O​
    Yellow Jacket 60613 Service ratchet Wrench
    amzn.to/3E8iYeZ
    =================================================
    Walk-in refrigerators and freezers are very large, insulated, enclosed spaces used to store and/or display refrigerated or frozen food or other perishable goods. They are used primarily in the food service and food sales industry.
    A Walk-in cooler is basically a large scale refrigerator - similar to what you have at home - except you can walk into this one! Every restaurant and fast food chain has a Walk-in cooler and it’s where they store all their refrigerated foods. Unlike a residential refrigerator though, a Walk-in cooler has a lot stronger refrigeration system that allows them to keep their food stored at optimal temperatures in order to meet certain FDA standards and to ensure that it passes local safety and food handling codes.
    Businesses from a wide variety of market segments use Walk-in coolers from Floral Boutiques to Breweries to Medical Research Facilities. Walk-in boxes come in all shapes and sizes and depending on the business’s needs, a Walk-in box can come with a lot of unique add-ons and accessories such as thermometers and temperature alarms that monitor temperature inside the box. If a business needs more than just a Walk-in Cooler, they can order a Walk-in Freezer or a Walk-in Combo Box which features to sections inside the box, one cooler and one freezer section.
    Walk-ins are constructed using panels. Walk-in Box panels easily lock into place via cam lock and can be installed right over most flooring’s (though you can purchase a Walk-in Box floor separately).
    A typical Walk-in Box can range anywhere from thousands of dollars to tens of thousands of dollars depending on many factors such as size, horsepower of Refrigeration unit, add-ons, panel thickness, location (indoor and outdoor) etc.
    =================================================
    Follow me on instagram! @JumperManTech
    For all inquiries E-mail JumperManTech@Gmail.com
  • Věda a technologie

Komentáře • 98

  • @jamescollins8148
    @jamescollins8148 Před 14 dny +1

    Great move, turning the meter off and then verifying.

  • @wd8557
    @wd8557 Před 2 lety +18

    The proper and ( SAFE ) way to discharge a capacitor is to set your meter on D/C voltage and put your probes on cap, and It will slowly start to drain it. I won 50 bucks off a guy one time when I told him I could OHM out a capacitor and find out if it's good or not. He goes I don't give a fk who taught you refrigeration you can't ohm out a cap. So we go to his van he get's out a cap I take his meter set to DC and drain it. Then I go NOW I am going to set your meter to Ohms and use your 9 volt battery in your meter to charge this capacitor If it's good you will start to see the readings rise which it did because it was new. After he picked his jaw up off the ground and handed me 50 bucks he drove off highly upset.

    • @kennethalovera2976
      @kennethalovera2976 Před 2 měsíci +2

      Damn bro thanks for the tip. gonna try me to score 50 bucks as well

  • @hecherr1121
    @hecherr1121 Před 9 měsíci +1

    Thx for the confirmation. I've guessed from the start that it could be the capacitor when you mentioned that the compressor was trying to start. Right now, im in school for hvac and subscribed and definitely going to watch your service call videos to learn some more 😊.

  • @jsnxng7578
    @jsnxng7578 Před 11 měsíci +6

    Hey jumperman great videos I’m currently at the tail end of my HVACR program and I have to say your videos are very help and gives a good insight on what day to day service calls look like. Thanks

  • @nicolerennie
    @nicolerennie Před 2 lety +8

    fantastic job!! I really appreciate how thorough you are w your craft & make sure you do it RIGHT & CLEAN & WELL. TY JMT🌟

    • @JumpermanTech
      @JumpermanTech  Před rokem

      Thank you! Stay tuned for new videos every week🔧

  • @binyammamo6454
    @binyammamo6454 Před měsícem

    You are really good man. I watch this several time.

  • @keorapetsefoli9652
    @keorapetsefoli9652 Před 8 měsíci +1

    Good job with fault finding, and you are right wires not looking good. Wiring must be neat and easy to follow. Please share your follow up video links.. Thank you.

  • @altralitycomforthvacr4337

    Love it man. I would be one of those guys to double check to make sure if the part is 100% bad but love your trouble shooting process

  • @TheSlim2none
    @TheSlim2none Před rokem

    Love those field piece probes a must for any real tech.

  • @salimlemdani
    @salimlemdani Před 2 lety +1

    You too man.
    I was looking for this kind of explanation and demonstration that is very rare.
    Hope to see the video when you did the work on this unit.
    Well done bro.

  • @resurgensix
    @resurgensix Před měsícem +1

    Always great content my man!

    • @JumpermanTech
      @JumpermanTech  Před měsícem

      Thank you brother! Stay tuned for new videos every week🔧⚡️🤙

  • @beaut9206
    @beaut9206 Před rokem

    Watched this video in my tech school. Thank you for sharing.

  • @BLOODSWEATXXXSTEEL
    @BLOODSWEATXXXSTEEL Před rokem

    Nice work and great integrity

  • @izzybell11
    @izzybell11 Před 2 lety +5

    Interesting and helpful video. Great job as always.

    • @JumpermanTech
      @JumpermanTech  Před 2 lety

      Thank you! Appreciate your comment & support 🙌🔧⚡

  • @mattalexander8919
    @mattalexander8919 Před 2 lety +3

    Nice Video, I enjoyed it. But seriously?? A light with a cord and plug.

    • @JumpermanTech
      @JumpermanTech  Před 2 lety

      Thank you! Haha I always use the M12 cordless drop light but it went missing so I went with the cord! Lol. Hate using a cord😂 Stay tuned for new videos every week 🔧⚡

  • @leonardhannah1045
    @leonardhannah1045 Před rokem

    Good details in describing everything

  • @musakavalci9470
    @musakavalci9470 Před 2 lety +3

    As always excellent content

  • @DavidMartin-yr9ym
    @DavidMartin-yr9ym Před 2 lety +1

    You the man bro keep knocking them down

    • @JumpermanTech
      @JumpermanTech  Před rokem

      Thank you! Stay tuned for new videos every week🔧⚡️

  • @HICDIY
    @HICDIY Před rokem

    Great job my friend lots to learn share ...❤

  • @davidchsw
    @davidchsw Před 2 lety +2

    Good video. When you have a potential relay there should be a bleed resister on the start capacity.

    • @JumpermanTech
      @JumpermanTech  Před rokem

      💯 safety first! Thank you! Stay tuned for new videos every week🔧

  • @timcastilo6962
    @timcastilo6962 Před 2 lety +22

    Should have slugged some refrigerant in it to keep their food cold till the next weekday then come back and do a leak search

    • @erickglo436
      @erickglo436 Před rokem +13

      That’s probably what he did off camera. It’s illegal to do that if you know there’s a leak in the system.

    • @stangaloski4208
      @stangaloski4208 Před 9 měsíci +1

      It's illegal? Really?

    • @aidanc3049
      @aidanc3049 Před 8 měsíci +1

      ​@stangaloski4208 its most definitely illegal in Europe anyway as if you know its leaking you might aswel vent refrigerant out to atmosphere

    • @JustinBurito
      @JustinBurito Před 5 měsíci +5

      In the United States it needs to exceed a leak rate for it to need to be condemned

    • @DABOSSnova
      @DABOSSnova Před měsícem

      Ur not supposed to do dat goofy

  • @thesilentonevictor
    @thesilentonevictor Před 2 lety +2

    Great work tech 👍

  • @blessingmasiyaw3984
    @blessingmasiyaw3984 Před rokem

    Thank you for the videos Jumperman Tech , i would some videos on BMS 💯

  • @carlosemmanuelgarciabrito791

    Nice and precise good work

    • @JumpermanTech
      @JumpermanTech  Před 2 lety

      Thank you! Appreciate the feedback🙏 Stay tuned for new videos every week 🔧⚡

  • @danielsaldana4663
    @danielsaldana4663 Před 5 měsíci

    Right on man great job

  • @mikedavis6023
    @mikedavis6023 Před 11 měsíci

    Very informative

  • @gabrielmendoza9165
    @gabrielmendoza9165 Před rokem +3

    Checking pressures is not the first thing you should do buddy

  • @dangerhellbender3245
    @dangerhellbender3245 Před rokem +1

    I like your get it down right work. Thanks for sharing

    • @JumpermanTech
      @JumpermanTech  Před rokem

      Thank you! Stay tuned for new videos every week🔧

  • @rocker8692
    @rocker8692 Před 2 měsíci

    Jumper man,are jumper man tech cause you are a master jump roper?

  • @Eddy63
    @Eddy63 Před 2 lety +3

    Good vid ... Thx for posting ...

    • @JumpermanTech
      @JumpermanTech  Před 2 lety

      Thank you Eddy! Appreciate the comment🙏
      Stay tuned for new videos every week 🔧⚡

  • @mansourramzey7711
    @mansourramzey7711 Před 2 lety +3

    Great video

    • @JumpermanTech
      @JumpermanTech  Před 2 lety +1

      Thank you! Appreciate the feedback🙏Stay tuned for new videos every week 🔧⚡

  • @Artisan.HVACR1
    @Artisan.HVACR1 Před 2 lety +4

    I noticed at the 4:22 time stamp you stated even though the system was marked as R-12, it was actually using R-134a. I understand that your reasoning for that statement was the phaseout of R-12 many years ago. However, if that system was actually using R-134a as you stated, it should have been CLEARLY remarked by the contractor that did the work with R-134a identifiers to indicate a refrigerant retrofit took place on the system. That is standard procedure for all refrigerant retrofits. Since that wasn't done, many technicians would think that was an old R-12 system that never went through a retrofit. Also, the low pressure switch setpoints would tell a technician if the cut-in and differential setpoints were set on the correct setpoints for the refrigerant type being used. I would look at those setpoints to see if they were truly set up for R-134a or if the setpoints were set up for R-12 pressure/temperature. That system could just be an old system that has stood the test of time and still has R-12 in it. I use the phrase "stood the test of time" until now that you were dispatched on to this service call where it has obviously finally shut down.

  • @gedyx
    @gedyx Před 10 měsíci

    Hey Boss excellent breakdown, i have a question, I'm studying for a test which type of cartridge fuse used in a industrial refrigeration one time fuse, time delay fuse, tube fuse with reset or plug fuse with reset?

  • @wasimedoo7994
    @wasimedoo7994 Před 2 lety +1

    Nice job

    • @JumpermanTech
      @JumpermanTech  Před rokem

      Thank you! Stay tuned for new videos every week🔧⚡️

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Před 2 lety

    Are they using a boiler for heat add for the loop? Anytime i work on a coaxial system i always do a quick backflush, unless its glycol. It takes a few minutes and very little amount of tools ( i don't disagree with your methods at all ) that unit needs some help

  • @jonstevens7032
    @jonstevens7032 Před 9 měsíci +3

    I would have fixed it on the spot.. Id have found the leak, fixed the leak, reclaimed the system, and recharged it. No need for a second service call.

    • @delrey-p
      @delrey-p Před 5 měsíci +1

      Most people would reclaim it then repair and recharge it instead of repairing it, reclaiming it then recharging it.

    • @citricdemon
      @citricdemon Před 2 měsíci

      If it were me, I'm built different, so it wouldn't be problem

  • @MariosACandRefrigeration

    Those compressors are not cheap to put a titen 2.60 $ instead of usa hd for $6.00 I would not take the chance.thanks for the vid,keep posting.

  • @marcushahn6750
    @marcushahn6750 Před rokem

    To the wall next fly please and thank you

  • @robertpeters9438
    @robertpeters9438 Před rokem +2

    You need to cover or remove the food products below.

    • @JumpermanTech
      @JumpermanTech  Před rokem

      Good advice. Thank you! Stay tuned for new videos every week🔧⚡️

  • @rishijagnarine1806
    @rishijagnarine1806 Před 5 měsíci

    What refrigerant was that system using?

  • @amfmechanicbowlingcommunit5048

    I am interested in learning more about this walk in freezers. I like the way you explained it. What of brad and kind of tools you use to check the high and low on the compressor?

  • @mahrez5244
    @mahrez5244 Před rokem

    Nice man , i wanna put my foot in a field may i work with you couple times for free just to learn more ?

  • @harryschrysan3183
    @harryschrysan3183 Před měsícem

    I recon that both caps got destroyed because of the compressor was short cycling constantly.

  • @WIINNER1040
    @WIINNER1040 Před 4 měsíci

    Jump man where you located

  • @hg2.
    @hg2. Před rokem +1

    I didn't see the link in the description for the follow-up video.

    • @JumpermanTech
      @JumpermanTech  Před rokem

      Thanks for pointing that out & for watching! Stay tuned for new videos every week🔧⚡️
      Follow up video link (Refrigerant Leak Repair)
      czcams.com/video/7sICT9-0nAQ/video.html

  • @monchichipower6334
    @monchichipower6334 Před 4 měsíci

    Prefer jobs that are routine
    This industry it’s always a different thing

  • @LuchambeeLuchambee
    @LuchambeeLuchambee Před 9 měsíci

    What's the cost of job like that

  • @Face426
    @Face426 Před rokem

    I got freezer room but it does not go less than 10 degrees.

  • @richardharmon874
    @richardharmon874 Před 2 lety +1

    Why no 409a?

  • @MrAtlasJude
    @MrAtlasJude Před 6 měsíci

    0:01 light switch

  • @bxnorris2002
    @bxnorris2002 Před rokem +1

    after hours heading to a wine cellar not working, first time working on one 😅

    • @JumpermanTech
      @JumpermanTech  Před rokem

      Just another day in paradise 🥂😂 Stay tuned for new videos every week🔧

  • @dirt5547
    @dirt5547 Před 2 měsíci

    If you would like to learn something about refrigeration, you can ask.

  • @shine-cg9uf
    @shine-cg9uf Před 2 lety +1

    💪🇺🇸👍❄

  • @primetime758
    @primetime758 Před 2 lety

    Just a question have you been doing this long? or are you a rookie

  • @nielsdaemen
    @nielsdaemen Před 9 měsíci

    Follow up on this?

  • @simplybuyer1
    @simplybuyer1 Před 6 měsíci

    What can you earn as a technician

  • @Brad-ns1no
    @Brad-ns1no Před 3 měsíci

    The last thing a tech should do is open up the system, even to just hook up a probe

    • @citricdemon
      @citricdemon Před 2 měsíci

      Yeah, unless that's what the problem is. Then it should be the first thing.

  • @elconodetumai13
    @elconodetumai13 Před rokem

    134a

  • @jyphc1679
    @jyphc1679 Před 2 lety

    You should use R422B is compatible with R 22 mineral oil. R134A is POE OIL

    • @JumpermanTech
      @JumpermanTech  Před 2 lety +2

      This was not a R22 system. It was a R12 system and the replacement is R134a👍Thanks for watching!

    • @rolandgirouard5914
      @rolandgirouard5914 Před 2 lety +1

      @@JumpermanTech only with an oil change kiddo. If you're not replacing the oil then you should use 209 and not 134

  • @richardharmon874
    @richardharmon874 Před 2 lety

    Where was leak.i bet it was on evap

  • @KobeOverLebronAllDay
    @KobeOverLebronAllDay Před 2 lety +1

    you should never discharge a start cap like that...use your meter or a resistor.

  • @walkingoverabridgeman2729

    Real techs don’t use shitwaukee tools

  • @lonewolf-sd2ko
    @lonewolf-sd2ko Před měsícem

    Should have top off with refrigerant . Full siteglass. 134 a tefrigerant. Discharged the compacitor with a screw driver on both terminals.