  • čas přidán 5. 10. 2019
  • One way of PLC-PLC Communication.
    PUT memory areas to a partnered PLC
    If this video helped you, please consider helping me by joining my "GoFundMe" and donating a small amount to my cause. Link here:
    www.gofundme.com/f/let039s-fi...
  • Věda a technologie

Komentáře • 95

  • @sashkindg
    @sashkindg Před 4 lety +1

    Hello! With PUT, Data Blocks can be optimized ?

    • @hegamurl7434
      @hegamurl7434  Před 4 lety +7

      Generally said: Yes!
      But the topic is a bit more complicated... when using "optimized block access" you can not used on an "address based" way anymore, so you have to use the symbolic names or drag and drop (like I did in the video with the data that the first PLC sends). You can PUT a whole DB, simply by dragging it and dropping it at the "SD_1" input.
      ...but as said... the topic of optimized block access is quite complex, maybe I'll make a video on it in the future.

    • @sashkindg
      @sashkindg Před 4 lety +2

      @@hegamurl7434 I think the topic of optimized block access will be very useful.

    • @MAli-zh6cr
      @MAli-zh6cr Před 4 lety

      @@hegamurl7434 In case of whole db with different data types needs to be sent, should I make another db on the other side (plc) with same data types/lengths as well?

    • @bacem_ch
      @bacem_ch Před 3 lety

      @@MAli-zh6cr yes

  • @shushimhuntinwabbits
    @shushimhuntinwabbits Před 2 lety

    Once again, a logical clear explanation for anything Siemens based... Thanks so much 🙂

  • @austins.275
    @austins.275 Před rokem +2

    Man I ran out of inputs on a big project and thought "PLC to PLC communication should be easy" 72 hours of pulling my hair and you saved me. Had EVERYTHING right but couldn't get the REQ parameter to work and your video explained it perfects. Thank you!

  • @zedjag7701
    @zedjag7701 Před 3 lety

    Another great TIA Portal video, thanks a lot.

  • @NikitaBelousovIE
    @NikitaBelousovIE Před rokem

    Thank you very much for so easy explanation of the complicated things!

  • @framos9991
    @framos9991 Před rokem

    My favorite teacher /Thank you!

  • @76POK
    @76POK Před 2 lety

    Thanks again. I have got so much help from this site!

  • @armchairfreedomfighter

    Keep'em coming!!

  • @Automation28
    @Automation28 Před 2 lety +1

    thanks for your videos, those are very useful to learn about automation

  • @pksharma9329
    @pksharma9329 Před 4 lety

    Sir your video always helpful for me....greetings from INDIA as well

  • @rhysdavies8947
    @rhysdavies8947 Před 4 lety

    Awesome video. Thanks!

  • @crja4114
    @crja4114 Před rokem

    My good friend you have a new subscriber. Thanks.

  • @braincrackz
    @braincrackz Před 4 lety +3

    hello there greetings from saudi arabia. god bless you

  • @sagarparmar8904
    @sagarparmar8904 Před 3 lety

    Sir , your videos are very helpful thanks 🙏

  • @alexchiosso221
    @alexchiosso221 Před 4 lety

    Thank you so much!!!

  • @simonmax3901
    @simonmax3901 Před 4 lety

    That was so informative

  • @naifsahin
    @naifsahin Před 2 lety

    Very useful, thanks.

  • @HectorRodriguez-si3yr
    @HectorRodriguez-si3yr Před 3 lety

    i love u man, thanks a lot.

  • @IK-qu9hw
    @IK-qu9hw Před 4 lety

    Thank you sir.

  • @mobros1298
    @mobros1298 Před rokem

    so clear thank you

  • @Raul-jl1nd
    @Raul-jl1nd Před rokem

    thanks, grate job

  • @vishalpatil6740
    @vishalpatil6740 Před 4 lety

    Thanks bro.... 👍

  • @mirrorcopy4681
    @mirrorcopy4681 Před 9 měsíci

    மிகவும் நன்றி நண்பா

  • @alvaropalenciano6147
    @alvaropalenciano6147 Před 3 lety +1

    Master!

    • @hegamurl7434
      @hegamurl7434  Před 3 lety

      Give yourself some years and experience and you will be the master!

  • @beautyofislam323
    @beautyofislam323 Před 4 lety

    Thanks sir

  • @kadadjamel4545
    @kadadjamel4545 Před rokem

    MERCI beaucoup

  • @kathirangamuthu3574
    @kathirangamuthu3574 Před 3 lety

    Thanks

  • @santoshkumarpatro2772
    @santoshkumarpatro2772 Před 4 lety +1

    Thanks for this video..its helped me

  • @GeneralKiller1337
    @GeneralKiller1337 Před 3 lety

    Nice job, Hega! I have one question: can I use this protocol with SINAMICS devices or the S7 protocol is only for the comunication between 2 S7 PLCs?

  • @danielesauhs5083
    @danielesauhs5083 Před 3 lety +1

    Hey man! I really like your videos, your explanations are excepcional, thanks for this knowlegment.
    Just a quick question, I have 2 PLC 1500, both have diferent subred, but one of them have two ethernet ports available, is it possible to link each other trought this free port?

  • @jamesedrielleaurellana
    @jamesedrielleaurellana Před 9 měsíci

    😍😍😍

  • @petervranks2723
    @petervranks2723 Před 3 měsíci

    Hello , video is well explained as ever, but still a question : do'n I need to define the S7-connections in the network view are they generated automatically ? What is the SIMATI-ACC option ? Best allways on for easy configuration with unspecified partner ( in my case S7_1500 GET from S7-1200 ?

  • @ouluberlu7373
    @ouluberlu7373 Před rokem

    Hi, I'have got a 1214CPU and using TIA V15. Unfortunatley, S7-communication library is missing. Do you know if I can import it in TIA? If yes, where can I get this library?
    Or is it a default library?
    Thanks for your videos !

  • @ansonkiek6471
    @ansonkiek6471 Před 4 lety

    If we set unspecified is this must delete the s7 connection ?
    My partner plc is s400 , I tried use this function communicate but always failed.

  • @NotMarkKnopfler
    @NotMarkKnopfler Před 3 lety

    Is this command also available over Profibus (rather than Profinet)? Thanks :-)

  • @seanyushi9096
    @seanyushi9096 Před 2 lety

    The connection id is actually not taken care by TIA. I've tried to have more than 1 PUT instructions and all of the block will always have the identical configuration following the latest changes i made, e.g. ip address of partner, memory address, etc. And this might be my issue, i need to change the connection name.

  • @stuatkins5
    @stuatkins5 Před 2 lety

    hi great video , if i wanted to send a qr code value (say PAC123) from one plc to another is a put instruction the best way?

  • @hansbrannstrom620
    @hansbrannstrom620 Před 2 lety

    Hi Thanks a lot for all nice videos you share with us :-)
    Is it even possible to test this PUT & GET function with PLC SIM? I does not get it to work....

  • @akshayjadhav6145
    @akshayjadhav6145 Před 3 lety

    Hello, thanks for such great videos.
    Could you have a video on Ethernet diagnostics to find communication error in your network and display on HMI.
    That would be very helpful
    And thank once again

  • @Gumballation
    @Gumballation Před 8 měsíci

    Hi sir! Your tutorial is amazing ❤. I have a question: is it possible to take text input from a human-machine interface and then process it using if/else statements like in programming? For example, the user types "password" and if the password is wrong, you know, like an if/else statement in programming.

  • @khaledtebai3920
    @khaledtebai3920 Před 4 lety +1

    This video came just in time! thank you so much!
    I have a school project, in wich I have to communicate three S7-1200. for now, connecting two PLC's is quit clear, with three , do I just need to add PUT and GET functions in the three of the PLC's if i want to send and read data from all three of them?

    • @hegamurl7434
      @hegamurl7434  Před 4 lety

      Yes exactly! Junse repeat for the third PLC

    • @genantamtam9364
      @genantamtam9364 Před 3 lety +1

      @@hegamurl7434 so putGet is only for siemens s7 communication? What if i want ro connect to other systems with my siemens plc? You have a video on that?

  • @deshabandhunayak320
    @deshabandhunayak320 Před 4 lety

    What is the maximum size of data we can send in PUT command?

  • @zhengkunyan8001
    @zhengkunyan8001 Před 4 lety

    Good

  • @legendary686
    @legendary686 Před 3 lety

    Thanks for the video. I have a question. Can you do this with PLCs from different brands? i.e Sending data from my siemens PLC to an omron in a different project for example?

  • @vijayakanthm705
    @vijayakanthm705 Před 4 lety +1

    Thanks to your good work.I have a question That i didn’t have a physical plc ,so shall configure two plc’s in a single project and test them with each other by single PLCSIM.Don’t bother if it is a genuine question

    • @tuleanhvt
      @tuleanhvt Před 3 lety

      you can simulate two PLC by PLC SIM

  • @santiagomoore374
    @santiagomoore374 Před 3 lety

    Sir, I have confusion over profibus, profinet, ethernet?? Please make a video on this topic.
    At 0:32 we found two ip address
    1) is 192.168.1.1
    2) 192.168.0.101
    What is those two ip?? Please explain or suggest any video

  • @ikkusoft
    @ikkusoft Před 3 lety

    Can this be simulated in PLC SIM,
    I tried, I'm not getting value in other PLC.

  • @Der_Geraet1
    @Der_Geraet1 Před 3 lety

    Kann man damit auch bspw. M0.0 der einen sps setzt M0.0 der zweiten sps? Sprich kann man einfach nur merker 1 und 0 setzten damit?

  • @dee-hl2tp
    @dee-hl2tp Před 3 lety

    Hi, another great video thank you. Just one question, In the PU_DB ADDR_1 parameter, (P#M0.0 INT 1) is M0.0 not just 1 BIT? If so how can you store an INT value in it?

  • @kreditslavkov8115
    @kreditslavkov8115 Před 2 lety

    Hello, pleace can i have a guestion.... i used a condition as you did at the end of the video for the REQ input. i also put a negativ contact "PUT_DB".DONE instead of freguency. but when i did it for the first time nothing has came into the my next plc. when i deleted it and did it again and upload the plc program again, it works. But when i was working on that again today also same problem and i have to do the same solution. deleted that condition and do it again the same. unfortunetly i cannot used the frueqvency condition, do you know why this negativ contact "PUT_DB".DONE doesnt work for the first time(the datablock put_db is green, but nothing has came into the database on the next plc...)? and is there any solution idea for condition like do it with every cycle of the cpu?

  • @user-ch1ep4hi7q
    @user-ch1ep4hi7q Před rokem

    I need to get encoder value from another cpu can I use the GET bock
    and how???

  • @Reaper0931
    @Reaper0931 Před 6 měsíci

    Hey, How can I send more information ? Im a beginner and you say in the end of the video that it is possible, how ?

  • @whatacode
    @whatacode Před 2 lety

    How Can we send use put for more than 5 plc and send data to one Common plc.....
    Please respond sir

  • @GeorgeMan_1981
    @GeorgeMan_1981 Před 4 lety +1

    Just subscribe ..

  • @mohdshahzad9427
    @mohdshahzad9427 Před rokem

    How to convert 1 Word into bits via siemens S7 1200 PLC?

  • @melvingomez426
    @melvingomez426 Před 3 lety +1

    How do you send multiple data..🙏🏽

  • @EshmesVid
    @EshmesVid Před 4 měsíci

    Uhh it also works on Logo not only S7

  • @dennisrubio2375
    @dennisrubio2375 Před rokem

    why does not PLC 102 isnt on profinet red plz help sr

  • @vinothparker7425
    @vinothparker7425 Před 4 lety +1

    Kindly make a video on various communication protocols and what is the difference between each of them sir..

    • @hegamurl7434
      @hegamurl7434  Před 4 lety +1

      Will do at some point!

    • @genantamtam9364
      @genantamtam9364 Před 3 lety

      @@hegamurl7434 hi there.
      You mentioned 14:46 that put/get is not your recommended type of communication but you mentioned "ip protocol"? Which one is that? Isit i-device/control? IO communication by pnpn coupler? Is that the most common?

  • @ericanderson560
    @ericanderson560 Před rokem

    DO you have to set up a TCON to do a put? If not what's the purpose of setting up the TCON in the prior video?

    • @hegamurl7434
      @hegamurl7434  Před rokem

      No you dont have to, they are different merhods of communication. The videos are unrelated

  • @ericanderson560
    @ericanderson560 Před rokem

    Do you have to be online for this to work? I can't get it to work at all. It tells me the data type is wrong when it is clearly correct, or it tells me the specified value is invalid

    • @ericanderson560
      @ericanderson560 Před rokem

      It says "The data type DInt of the actual parameter does not match the data type Remote of the formal parameter". In this case I dropped it in directly from the tag table of the receiving PLC, which is in my project. They are both Dints

  • @mat77111
    @mat77111 Před rokem

    I take it this method doesn’t work with S7-1200 PLCs?

  • @umairshah9735
    @umairshah9735 Před 4 lety

    Hi dear , Watching your vids . Best one can offer for the betterment of human beings . Thanks alot . Dear i want to send my Level signal from one PLC to other . I am no expert . Kindly, advice me videos in your playlist which can help me . Thanks

  • @Olavotemrazaodenovo
    @Olavotemrazaodenovo Před 4 lety

    Where can I find the frame structure of a command between IHM and PLC by profinet? If I want to snif the protocol to discover how the adress of the word in PLC is coneccted with other adress word in IHM, how can I do it? Congratulations from Brazil. Thank you.

    • @hegamurl7434
      @hegamurl7434  Před 4 lety +1

      Don't know what exactly you are looking for... but for analyzing network packages I recommend a free tool called "Wireshark" with which you can analyze network packages

    • @ziborgbe
      @ziborgbe Před 4 lety +1

      search for s7 protocol

    • @Olavotemrazaodenovo
      @Olavotemrazaodenovo Před 4 lety

      @@hegamurl7434 I want to analyze it. Thank you for wireshark!

  • @mubarishussain3696
    @mubarishussain3696 Před 4 lety

    So you only put instruction to communicate.What about get instruction on receiving PLC.Is not required?

    • @hegamurl7434
      @hegamurl7434  Před 4 lety

      You only have the instruction on one PLC: If you want to read data from another PLC you use "GET" and if you want to push data into the other PLC you use "PUT". The other PLC does not need any function (although some prerequesites as described in the video)

  • @mehmettevfikcete3397
    @mehmettevfikcete3397 Před 4 lety

    Hegamurl hi,
    Is there a limit on this process. I mean, can i send for example 200 byte datas with 300 ms rate ?
    And could you share a lesson about putting or getting data from different brand plc's to siemens plc please.(not s7 connection)
    Thank u so much again. God sent you to us. :)

    • @mehmettevfikcete3397
      @mehmettevfikcete3397 Před 4 lety

      Note: our network bandwith is very nice. There is no bottleneck on this topic.

    • @hegamurl7434
      @hegamurl7434  Před 4 lety +1

      Very good question! I have never tested the maximum, but also have never reached it. I'll simply test it out (and also read the documentation) on it, when I have the time.
      As far as I know the PUT/GET here is only between SIMATIC components. For other devices I always recommend a TCP connection (my next videos will be about that)

    • @lassejespersen9880
      @lassejespersen9880 Před 4 lety

      With the 1500 system you Can PUT 400 bytes and GET 400 bytes

  • @MrPushpalm
    @MrPushpalm Před 2 lety

    Will s71200 communicate with s71500

  • @saeed2tube
    @saeed2tube Před 4 lety

    Hi
    I have question maybe irrelative.
    How we can mirror hmi to monitor without pc and use finger touch of monitor?
    And if you can please make video about data logging server.
    thankful

    • @hegamurl7434
      @hegamurl7434  Před 4 lety +2

      Hi! I am not sure if I fully understand your question, but if you want to use your PC as HMI you will need WinCC Professional Runtime on your PC, which will simply run a program that emulates an HMI on your PC.
      Added Data Logging to my list!

    • @saeed2tube
      @saeed2tube Před 4 lety

      Thank for your answer. But i want connect monitor directly to hmi.

    • @GeorgeMan_1981
      @GeorgeMan_1981 Před 4 lety

      Use sm@rt client ..

  • @mrloh7197
    @mrloh7197 Před rokem

    Is it possible to use Put and Get instruction with the CPUs with different TIA Portal Version? One using V15.1 and another using V16.0.

  • @BG-gr1uu
    @BG-gr1uu Před rokem

    Please improve voice quality,

  • @hichemchawi4498
    @hichemchawi4498 Před 4 lety

    thanks for your videos, those are very useful to learn about automation