सीखें दो इंडोर और आउटडोर की वायरिंग ! How To Connect 2 Indoor Units With 1 Outdoor Unit

Sdílet
Vložit
  • čas přidán 29. 08. 2024
  • सीखें दो इंडोर और एक आउटडोर की वायरिंग ! How To Connect 2 Indoor Units With 1 Outdoor Unit
    Hi Friends,
    I am Ismail Khan and all of you are most welcome in my CZcams Channel Ideal For Technical
    In this video I have explained about multi split AC wiring which contains 2 indoor units and 1 Outdoor Unit
    This is old model multi split AC wiring which has a four terminals contactor this contactor has two NC and Two NO Terminals.
    In this split as two indoor units operates their compressor separately but condenser fan is operated by both indoor units that is why it is required a contactor
    Hope you enjoy this video
    Thanks
    About The Channel:-
    Dosto Mere CZcams Channel Ideal For Technical Ke zariye Refrigeration And Air conditioning, Electricals, Electronics, Mobile, CZcams Channel Aur Computer Se Related Technical Knowledge, Tips And Tricks Ke Saath Social Welfare Se Related Video Upload Kiye Jaate Hai
    Videos Ko Dekh Kar Comment Zaroor Kijiyega
    Watch My Other Videos :-
    Biggest Problem Of PTC Relay Solved
    • Biggest Problem Of PTC...
    Double Door Refrigerator Wiring
    • Double Door Refrigerat...
    What Is Gas Geyser
    • Inside Gas Geyser ! Ho...
    Compressor Is Running But AC Not Cooling
    • Compressor Is Running ...
    How To Fit The Valve On Refrigerant Can
    • How to fit the valve o...
    Double Door Refrigerator Not Cooling
    • Double Door Refrigerat...
    Big Fault Of Double Door Refrigerator
    • Big Fault Of Double Do...
    Window AC Leakage Test And Repair
    • Window AC Leakage Test...
    Frost Free Refrigerator Wiring
    • Frost Free Refrigerato...
    Wiring Of Refrigerator
    • Wiring of refrigerator...
    Less Cooling In Refrigerator
    • Less Cooling In Freeze...
    Damper Of Samsung Double Door Refrigerator
    • Damper Of Samsung Doub...
    How To Top Up Gas In Window AC
    link:-
    • Window AC Gas Top Up !...
    Refrigerator Leakage Test
    Link:- • Refrigerator Leakage t...
    Song/Music :-
    Song/Music Attribution Not Required Provided By CZcams Library
    Disclaimer :-
    Copyright Disclaimer Under Section 107 Of The Copyright Act 1976,
    Allowance Is Made for " Fair Use " for Purposes such as Criticism, Comment, News Reporting, Teaching, Scholarship And Research, Fair Use Is A Use Permitted By Copyright Statue That Might Otherwise Be Infringing
    Nonprofit, Educational Or Personal Use Tips The Balance In Favour Of Fair Use.
    Thank You So Much
    #multisplitacwiring
    #ductlesssplitac
    #idealfortechnical
    Contact For Business Inquiries :-
    ismail05ideal@gmail.com

Komentáře • 27

  • @dilshadqureshi9573
    @dilshadqureshi9573 Před 15 dny

    Very good information sir g u r the genius ❤ love u from u.p

  • @mujeebansari1965
    @mujeebansari1965 Před rokem

    Very nice sir 👍👍👍
    Sir ka samjhane tareeqa lajawab hai ❤❤❤

  • @tahirfarooq2551
    @tahirfarooq2551 Před rokem

    Very informative khan sahib. Geety raho.

  • @ArmanKhan-jq4gm
    @ArmanKhan-jq4gm Před rokem

    Superb wiring sir

  • @AmirulIslam-hc6eo
    @AmirulIslam-hc6eo Před rokem

    Split AC ka contactor ke sath demo banake video banaa ke le kar sir❤❤❤❤❤❤

  • @ArmanKhan-jq4gm
    @ArmanKhan-jq4gm Před rokem

    Nice video sir

  • @UmmeKhan-fy7ei
    @UmmeKhan-fy7ei Před rokem

    Very Nice👍👍

  • @SUMITKUMAR-co6ij
    @SUMITKUMAR-co6ij Před 5 měsíci

    Very good

  • @mritunjaypratyush7180

    Sir right wala main common main aap phase diye hai jabki neutral jayega tabhi dono indoor ka wiring compressor se same goga

  • @shalukhan4223
    @shalukhan4223 Před rokem

    Super🎉

  • @rkpandey7447
    @rkpandey7447 Před 4 měsíci

    Pls share more details..can we convert single outdoor unit in to two indoor unit ,this will work

  • @parijeevika1060
    @parijeevika1060 Před 5 měsíci

    Agr ek time me ek hi ac chalaye to bijli ek ac ke hisaab se hi kharch hogi kya

  • @singhgurpreet1482
    @singhgurpreet1482 Před rokem +1

    Sir fridge ke capllery ka pressure kaise test krte a our jb hmm pressure test krte hai to kya frezer teda nhi hoga

  • @parijeevika1060
    @parijeevika1060 Před 5 měsíci

    2indor 1outdor
    Me agr 1hi AC chalega to billi ki khapat ek ac ke hisaab se chalegi kya

  • @user-rl1hn4dp1b
    @user-rl1hn4dp1b Před rokem

  • @rupeshnaik9056
    @rupeshnaik9056 Před rokem

    🙏

  • @prakashgotame8875
    @prakashgotame8875 Před rokem +1

    Sir 2 indoor ekai time me chalaya ta tyo chalega ki naii

  • @rishikesh-yt435
    @rishikesh-yt435 Před rokem

    Samajh mein nahin a Raha hai sir ji

  • @prakashgotame8875
    @prakashgotame8875 Před rokem +1

    Sir One outdoor unit 1 compressor 2 ton ka And 2 indoor 1 to 1 ton ka uska wiring diagram kaise hoga indoor chalega tyo kya hoga

    • @IdealForTechnical
      @IdealForTechnical  Před rokem

      Thanks for comment
      Apna question thoda clear kijiye please

    • @prakashgotame8875
      @prakashgotame8875 Před rokem

      Sir Maine bolrahu ki One outdoor unit 2 ton ka haii And 2 ton ka outdoor se 1 ton 1ton ka 2 indoor unit connect hai outdoor me 1 haii compressor haii chalega ki naii uska wiring kaise hoga sir

    • @IdealForTechnical
      @IdealForTechnical  Před rokem

      @@prakashgotame8875 kya apne iski pipe connect kar di hai,
      Iski wiring ho jayegi

    • @prakashgotame8875
      @prakashgotame8875 Před rokem +1

      Kaise hota haii video banaya piz

    • @IdealForTechnical
      @IdealForTechnical  Před rokem

      @@prakashgotame8875 OK 👍