Top reasons compressor triping problem | Fully4world
Vložit
- čas přidán 10. 07. 2019
- Hello dosto apko is video mai compressor striping kin kin wajohat pr hota hai kia kia problem ay to compressor trip hoga ye btaya gya hai umeed lrta ho apko is video sy koch new janny ko mily ga...
Top reasons compressor striping problem in urdu hindi | Fully4world
------------------------------------------------------------------------------------------------------
Subscribe: / fully4world
Instagram Follow: / azamali256
Facebook Page: / . .
Azam ali FB ID: / smak.azam
Website:: www.fully4world.com
For Sponsorship Email: Fully4world@gmail.com
------------------------------------------------------------------------------------------------------
Big size copper pipe tube bender-Easy pipe bending
• Big size copper pipe t...
Air conditioner gas leakage common mistake || Never do such a mistake
• Air conditioner gas le...
how change ac outdoor gas valve in Urdu/Hindi
• how change ac outdoor ...
Mini Gas Welding Spray Bottle Review & Unboxing 2019 in Hindi/Urdu
• Mini Gas Welding Spray...
PCB Rely Problem Outdoor Direct on in urdu hindi
• PCB Rely Problem Outdo...
Problem coming to AC due to low gas in Hindi / Urdu
• Problem coming to AC d...
Latest technology and RAC / HVAC related videos and information - Věda a technologie
1_Gas over honeki wajahsebhi ye issue banta hai
2_outdoor fan motor slow ya nahi chalneki vajahsebhi ye issue banta hai
3_capicitor vick hone perbhi ye issue banta hai
4_filter drier block hone perbhi ye issue banta hai
5_outdoor unitme jyada dust honeperbhi ye issue banta hai
Bhai mane aap ke Vedio se bahot kuch seekh 💯 aap ke bahot best video rahti hai
My frend miis you number seding ok how aryou good
sukria bai es video ko me badee derr se tlas raha tha 🙏👍👍👍👍
Gud info sir subscribed
Tnx sir aap bahut achha sikhate ho mai aapse bahut khuch sikha hu aur khud ka business b dala hu
Kaha dala hai bhai
Jumma Mubarak bhai
UK number video
Thanks bhai jaan
Thank u sir 👍👍
Hi
My best dearest bro
Nice bhi....
Nice
Bhai ap vedio bhut acchi bna rhe hai hme bhut kuch seekhne ko mil rha plz cassete ac complain ki vedio bnaiye bhai jaan
Ok
Ma Sha Allah
Very nice video
Sir repair ka all video ki Ak link dijiya sir, joldi siknay Kay liya accha hoga .
Nice video
Nice video sir ji ♥️🌹🌹♥️
Thanks bhai
Walekum Assalam sar
In our experience we faced a similar problem with an inverter air cond last season.
After the fault tracing we found there was a blockage in the heat valve, that was due to welding by a technician in order to repair the leakage
Popely checking ato z heat valve enize unit first oldok captier andnot condesahion no cleand unt first after checkin one byed reparing fulte triecglecking find outing and popely finding ĺà+
Hi
@@jollyscaria1922 hi
Achi information
Thanks
Walekumsalam
Good
good sir
Thanks
Assalamu alaikum sir , kuchh bataye inverter ac se matallik
Very nice video Sir mera ak compressors 5mi chalne k bad hi mplekar band ho jata ha ma uska gas kam kia to v band horaha ha capi...vi chenj kia firvi band horaha ha apka had video dekta hu
Gjb
Today I was facing improper cooling problem in my 1.5 ton Volta's a c. The fan motor speed was low. Resulted compressor was tripping. The compressor was drawing high amps @15.2 amps.The technician changed the fan capacitor and some gas was topped up.The discharged pressure after topping up R22 gas was measured.It is 72psi. My question to you is that what is the MFD of fan capacitor? Does the out door coil chowkup results compressor tripping? Do you recommend pressure washing of indoor and outdoor unit?
Hi
Azam bhai ir blaster banana sikhao kisi bhi mobile me connect karke mobile se c connet kar sake
Azam bhai yaar Ac k full parts pe video banana yar k Ac k kitne parts hain mukamal
Bhai yaar indoor unit orr outdoor unit dono k mukamal parts pe video banana is liye bola k abhi mera week 3 chal rha ha abhi kaam start kya ha shukriya Allah hafiz
MM
Nice video sir
LPG TIN ME GAS KASE BARE VIDEO banawo bahi
bhai aap 5 minutes ka video bnate hai jisme se 2 minutes aap ek baat ko bar bar bolte samne wla banda irritate ho jta hai or video bnd krne ka dil krne lgta hai so plz video ko bada bnane ke chakkar me irritating mat bnaiye
Y lv
Sir guess km honi ki wja se b hota h trip
gas kam ki waja sy nahi hota, zyad ahony ki waja sy ho sakata hai
Baz dafa aesa hota hai out tor unit bohot ziyada ganda hota hai tabi trip hoga mere khayal se use pani marne ke bad who set hojata hai
Ha g
Sir isme chok honeki waja se bhi hoga trip or compraser ki winding kamzor hone ki waja se bhi trip hota hai ya nahi
Ha g hota hai or agr capacitor khrab ho to bi
Sir apki video se bahut kuch seekhne ko milti hai
Sir ek split AC jo din ke time one minute baad compressor trip kr jata hai but evening mein bilkul thik chalti hai iski kya wajah ho sakta hai
Capacitor ka bi masla ho sakta hai chrck krk pta chly ga
bhai 134a gas dalo thori si heatup hora h day mai temp zada hota h or evening temp kam hota h
aslam.e.alekum
Out door sahi lokeshan pr na hone ki wajha se bhi trip hota h
Refrigerant jyada charge kr dene pr bhi trip hota h
Hmm
Or service bhi ho rakhi hai voltage bhi theek hai kya problem ho sakti hai usme gas refil karu ya nhi
Sir ji problem AAP ne batai hai isme agar ac room sencer se trip kare to kaise pata kare
Sensor change krky ya 10k ohm resistor lga kr
Ok
Assalam Walekum Azam Bhai kya hal hai Sar Mera yah Sawal tha AC ka compressor 1 ton 1.5 Aadha Ghanta chalne ke bad compressor trip kar jata hai kya reason hoga please reply I am waiting
Nhi
Bhai fins agr dammeg hui hai to bhi trip ho sakta hai ?
Ha g agr bohat zyada demmeg hui hai
Main Ne Kisi fitting Kiya Hai Woh Whirlpool ka uska side Se Hawa fake hai any Congress asite se aur condenser ke sightsaver fitness fees Samne se nahi a raha hai reply dijiye bhai jaldi thoda
Filter caplry choke hone pr bhi trip hoga
Azam bhai oil bahot kam ho jae to bhi.trip hojata he muje lagta he nere sath esa folt aaya he
G ha
Hellow sir haier aik ton ka ac ka outer tripping ka issue ha moter change keri ha fan moter likin ab outer trip ker reha ha hitup hoke 20 to 30 mint baad fan chalta rehta ha outer trip hojata ha kiya reasion ho skata ha
hi
Mera ac day time trip Hotham hai
Voltage Kam honay ki waja se bhi issue hota hai compressor trip Ka??
Ager Ac ka power supply cut out 10 minutes bad chaltey chaltey bund ho jaie to kia fault ho ga capacitor bhi change kia hai mager fault ab bhi araha hai voltage bhi 220v to 230v hai🤔
Bhai pcb me dikkat ho sakti he
Saplai bhi thik he or capasetar bi thik he 220 volt bhi aa rahe he sarvice bhi dhup me bhi nahi laga he compressor paipig bhi sahi he fir bhi trip mar rah he
Phir compressor kamzoor ho gya hai
Sir ek problem hai ek ac hai daikan ka uska compressor trip ho raha hai
Llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll
Bhai Mai app ko falow karta hom mujay aisa complain Mila hai 1Ac Mai E6 ata hai
Dosray Mai F4 araha hai dono 2.5 ton hai
Es error ko kaisay Hal karn
Sir apr ki jaankari datawo kona falt hoga kay ampr lega
Azam bhai ek question hai 2.5 tr ke outdoor me 2 tr ka indoor work karega kya
Nahi.....altar ho ga phir.agar laga dia bhe . To restart nahi ly ga.....ok
Sir compressor 3 ghante bad trip karta he voltage fan capacitor bhi sahi
24 ya 26 pr chalao ac
1.5 ton Volta's 5 star split a c ke andar kita na gas pressure rakhana chahi ye?
6
Sir Sabor is Ac ha barkar trip to tah ha
Voltas inverter AC din main chalta h pr raat main nahi chalta to kya. Problem ho sakti h
Gas ka masla ho skta hai ya compressor ka ye to ab check kr k pta chly ga
Hi aoa bro ac ky indoor wala room temperature sensor ager indoor coil ky bilkul sath hy to us ka kia issue aata hy
Hi
Sir 15 mint main compresar trio ho rha hai phr bht heet ho jata hai strt hi ni ho rhaaa
Compressor kitne parkar ka hota hai
Outdoor unit 5 millit k bad trip ho jata he... Firr se 5_10 minit me start ho jata he... Fan speed is good ..... What is the reason of tripping problem... ( Panasonic Split AC 1.5 T
Sam to sam problem
@@zikriyakhansafi3469 outdoor condenser coil me problem thi. Mene jet presor moter se whater. Condencer ko servicing kar diya ab Sistem ok ho gai . . Amp Norma ho gaye
Hello
Inverter a.c me is problem hoya to kiya karu.
give number
On hotay hi compressor band hojaye fyr?
Akelay outer unit k compressor ki serviceability kesay check hogi???
Hi sgehzad
Which camera you are using?
Fone
Hi Naveen bahi kase ho
Fan ki speed bhi sahi ha koi tariqa ha fab ki speed malO kerne ka ke kitni speed iski hoti h
Sir agr hm ik new ac install krny jain or wahn undergrond piping hui hoti h os m 3 wires ya 4wires hon or ac 5wairs wala ho to osy kesy coction krny h plz sir ik video bna dain
Is 2 wire is tarha ki hoti hai jo neutral hoti hai un dono nutral ko 1 wire sy hi lga skty hai
چل ۔۔۔۔۔ کنی
Voltage km hone pr bhi trip hoga
New split ac triping every 5 minute
Mitsubishi heavy duty 1.6 wrost ac
Sir aapki aplication nahi a rahi h play store par
Application ka naam kiya hai bhai
Azam bhai o garnal ka r410 h but usmen out nhi nekl rha raly b chenge krwa li h out door raly b change ki vair wadra b chek ki but fold nhi hal ho rha
machine new laga ne bolo
Bhai temperature jyada hone pr bhi trip hota h
Kha se ho app sir
Water Pressure cleaning ak sal me kini bar karna chhiye? Usase indoor aur out door unit ki fins kharab nahi hongi? Usaki life kam ho ja ye gi kya?
Thanks
Abhi thandi chalu hongi to karwa ke rakhu ya garmi se pahle karwa lu?
Azam bhai the reason could be that the temperature surrounding the out door unit is very hot. This reason I have experienced.
Hassan Faheem yh problem esi waqt hoti hai jab outdoor heat ko sahi tarah say bahir nahi nikal pata ta.....agar andar heat jama hojay or bahir ki jo heat hogi wo mil kar is ko mazeed hot kartay hayn us ki waja say trip hoata hai......agarbp fan sahi raftar say move karrha hoon to jitna be hot weather ho kabhi be compressor trip nahi hoga...
bhai mera problem ye hai mera split...rat bhar sahi chalta hai low blower per....agr fan speed tezz karo to trip hojata hai...din main low blower per bhi nahi chalta....mera out door unit ki fan speed bhi good hai capacitor bhi new lagya hai gas pressure bhi thek hai...phir kiya waja hai jo out door unit heat up hota hai....or out door unit maine khud saff kara hai pani say usk bad bhi ye problem ari hai....
@@subscribefornoreason1520 Gas pressure kita he?
55
@@subscribefornoreason1520 Me A C technician nahi hun.Me ak engineer hun.Firbhi general knowledge ke hisab se us me 65-75 psi ,Running me, compressor ON me (R22 gas)gas pressure ho na cha hi ye. Aap pahele leakage check karwa ke gas top up karwai ye. Firbhi A C technician senior se salah lena. Meine abhi abhi 72 psi gas topped up kiya,fan capacitor change kiya he aur abhi ekdum cooling badhi ya aa ra ha he.
Bhai genaral ka 5ton ka ac 5 minute chalta fir chalu nahi hota
Compressor me oil km hone pr bhi trip hota h
Hmm
azam bhai compressor strt hoty he trip ho jataa h
Camparsar chulo nahi hon ka karan
Azam bhai aapka chanal nhi mil rha kya aapne chanal Dala he ya na
Bhai inveter ac Ko non inveter kar sakte hai kya
Nhi
Help Me Bro
Assalam o Allikum
Bhai meray pass Haier ka 1.5 ton ka split hai Gas ok Service ok. capiciter both are ok.
Per one hour k bad fan off ho jata hai compressor chal raha hota hai jis ki waja buhat heatup ho jata hai phir 1 hour is ko cool kerney k bad dobara on kertey hein.
Karachi k AC tehnichion kehtey k fan motor kharab ho rahi hai jab k fan speed bilkul ok hai.
Please bataein k mein aaya circuit check kerwaon ya fan motor change karon.
JA ZAK ALLAH
Hahaha.... nice bhai....acha sawal hy....agar ap k pas steplizer hy to os sy voltege 300 sy ziyada out ho rahy hen.agar direct hy to bhe volteg ziyada hen.jab volt ziyada hon to fan capiceter bhe phat jata hy.
Imran Compressor Tripping rat ko q nhi hota
Sir agar outdoor unit sa Capri nikal k 1/4 ka pipe laga diya jay too kya hoo ga...........?
Ostad admi ho....is ka jawab kia hy ap he bta do.....lekin mojhy jo experions hy who ye k..retan bhe aiay ge magar indor temprchar nahi bana raho ga....lekin pipe agar 19 inch sy 12 inch ho to thorda bohat kam ho ga.....agar 6 inch kar dia to compreyshar jal jaiay ga.
2 minute ka problem 5 minute ka video..ek baat ko das baar repeat karte ho..isse confusion hota hai
Ok next time behtar hoga
Bhai aap kaha se ho
Lahore
Jekar pcb de kar tripp karda hove ta kese pata kare
Sir hama rah Ac trip ho ta he . gass ka . thore kam ho to fr be trip ho ta he
Capacitor khrab ho sakta. Hai
Ya service hony wala ho ga
Capesatir change keya . he . fr be trip ho ta he .
Assalm o Alaikum bhi ma sab dakh lia capistor b chg kar k dakh lia ha bs returns b bhot dair say ati ha or kuch dair bad trip ho jata fan chalta ha but comprasor trip ho jata ha clean b ha
Outy dhoop ma laga ho ga
Stabilizer laga ho ac k sath or ac trip kr jae to kia stabilizer on rahe ga ya trip kre ga
Breaker lga hoga to wo trip kry ga
AC ke ander ya pipe me pani chala jaye to kiya kare sir
Chootar