Buhat Khoob Sir . Main nay buhat say HVAC Lesson dekhay hain . Apki Video dekh kar Pata chala k Sabse best Lesson ap dete ho . Outstanding Learning rhi meri. Thanks Alot
Aapane bola Jo bataya super super lakar ke yah sab bataya lekin vah Jara jo hai latest Nahin Dikh Raha Hai Jara Bada Akshar Mein dikhega To bahut Achcha Tha Jo formula aapane Jo bataya Upar Mein vah formula Humko chahie tha agar aap mil jaaye to bahut Achcha badhiya Rahega bahut bahut Shukriya Allah Hafiz
Dew to Sea level refrigerant is higher than lower or lower than higher? Related this question like the super heat. I don't know This questions the right answer I asking you.give answer please somebody was asked me this question in the interview.
Sir chillled water temperature outlet 9 aur inlet 4 hai compressor 100% load par nahi ja rha hai aur expention valve 47% hi open ho raha hai chiller setpoint -2.0 rkha hai kya problem ho sakata hai
Ap nay temp ni batiye , comp c nikalnay k bad kia temp r pressure hota ha cond c nikalnay k bad pressure and temperature and so on. Yeh bata datay to acha retha
Centrifugal compressor is mostly use in chiller for industrial purpose.i don't have answer related to your first question but it might be 7-9 degree celcius
Bht acha explain Kiya apne
very good Explain Thanks
Outstanding Explanation
Buhat Khoob Sir . Main nay buhat say HVAC Lesson dekhay hain . Apki Video dekh kar Pata chala k Sabse best Lesson ap dete ho . Outstanding Learning rhi meri. Thanks Alot
Tanku sir
Nice knowledge
Sir ap bohat asha samjhate hai me be ye qolification 4month ka corse hai ap ke video real hai thank u
Good explain
Good work bhai
Aasalaam alai kum awesome very nice explained
awesome bhai
Great bohat acha breif krty ho bhai ماشاءاللہ
Malomat main izafa huwa bahi aapka bot shukria
Good work
A complicated topic is heat is true highly appritiatv ur effort keep making more vdo including air balancing sty in tch frnd
Bahut hi umda explaination tha bro
I appreciate sir 🙏
Good Explanation. Nice Work
Thank you Sir😎🇮🇳💗💗
❤❤❤❤
Very well explained.
Good brother salamat rahin ap
👍
Very good effort 👍😊☺️ good bless you keep it up
Really great agr kisi ne pura video dekha hobto
🇮🇳thank you
Great Bro Keep it up you doing good job👍👍
Perfect explain
Sir, the way of teaching is very good
Very good 👍
Thank u sir
Very nice sir
Thanks
Good explanation
Excellent
Superhit sub cooling practical dicaho sir
nice sir. absoption chillr ki cycle bhi detail se batain.
Very nicely explained. Can you make a video explaining the difference between saturated suction temperature and saturated discharge temperature ?
Aapane bola Jo bataya super super lakar ke yah sab bataya lekin vah Jara jo hai latest Nahin Dikh Raha Hai Jara Bada Akshar Mein dikhega To bahut Achcha Tha Jo formula aapane Jo bataya Upar Mein vah formula Humko chahie tha agar aap mil jaaye to bahut Achcha badhiya Rahega bahut bahut Shukriya Allah Hafiz
I love you sir
I'm waiting heat exchanger part 2
Masha Allah Bhai Ixpensen Val ka jo Belo jo Tampretur sens kar ke open Clos hota hay uski ditel bataye
Thanks for good explanation, can also explain in another video how to troubleshoot system by using super heat and subcooling parameters.
Yes I am also waiting for another video about troubleshooting system by using superheat and subcooling
@@thelifetraveler1609✨✨✨✨✨Ys ✨✨✨✨✨y ✨dyYs ✨✨dyyd y 😒✨✨✨y ✨d ✨✨✨✨ ✨y ✨ ✨✨ ✨✨✨✨✨✨✨✨6s ✨✨✨s ✨✨s ✨✨✨✨✨✨y✨✨✨✨✨6 ✨✨6syd ✨✨✨✨✨✨✨✨✨✨✨✨ss ✨✨6 ✨a ✨✨✨✨✨d ✨y ✨s ✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨s✨✨✨✨sss ✨s yd ys ✨ss ✨✨✨✨✨ys ss ✨✨✨ ✨ss ✨✨✨ ✨✨✨ys✨s ✨✨ ✨s ✨ ✨✨ ✨✨✨✨y✨✨s ✨✨6 ✨ys✨✨✨✨Ys ✨✨
@@thelifetraveler1609 hi 😒😒 h dy 😒dy 😒😒😒6sss 😒😒s 😒😒s😒6yy 😒 😒ss 😒y 😒ss 😒😒😒😒😒😒😒s 😒d 😒😒
😘😘😘😘😘😘😘
Sir aik viedo bana do heat recovery and kitny type ka filter hoty hain
Sir rotary screw compressor k bry main koy viduo bana do
Thanks sir super heat or subcoling ko calculate kis taran karte hain
Assalam o alaikum bhai
Dew to Sea level refrigerant is higher than lower or lower than higher?
Related this question like the super heat. I don't know This questions the right answer I asking you.give answer please
somebody was asked me this question in the interview.
Aur expansion value ko b Kya ham latent heat changer kare sake hai
R22 ka Ek bar temperature or pressure ke sath batayenge
Bhai R22 Refrigerant ka Boiling point
-40.7 degree Celsius
R22 Refrigerant ka Freezing point kaina hota hai bhai
Kisi ko pata hoto plz comment kare
Ye harara MATLAB kya hota hai
Sir mujhy ye pochna tha ke ager hum out door condenser per water suprey kery to koi issue to ni.wo vapors ko liquid me change kery ga .
Sir chiller may aik alarm a Raha hai . display par high concentrate alarm a Raha hai agr tafseel mil jaiy tho
heat exchenger ke bare batae
Sir chillled water temperature outlet 9 aur inlet 4 hai compressor 100% load par nahi ja rha hai aur expention valve 47% hi open ho raha hai chiller setpoint -2.0 rkha hai kya problem ho sakata hai
Ap nay temp ni batiye , comp c nikalnay k bad kia temp r pressure hota ha cond c nikalnay k bad pressure and temperature and so on. Yeh bata datay to acha retha
Use pv and ts diagrams sir
Sir apne types of vapour and types of liquid gas K bare me nahi bataya
Sir pressure badhta hai to kyu temperature badhta hai plz sir reply
Sir BMS aur HVAC me keya antar hai
Aoa what is saturated suction temperature
Latent heat & specific heat chage kaha per hota he cycle me
Discharge super heat?
Feed oil temperature kese control kare
Ye hararat Kya hota h?
I have some questions can u give me answer please 1)What is the required temp.in cooler? 1)What type of compressor used mostly in the chiller?
Centrifugal compressor is mostly use in chiller for industrial purpose.i don't have answer related to your first question but it might be 7-9 degree celcius
(1) 8 degree range of acceptable cooler temperatures
(2) Mostly used of Centrifugal compressor in Chiller.
Sir,
Discharge Superheat,
Suction Superheat,
Saturated Condensate Temp
Kaise calculate karte hai.
U r Pakistani?
Ur voice by traces
Boring lag rahahai