TIA Portal: OPC UA Client Interface Tutorial

Sdílet
Vložit
  • čas přidán 27. 08. 2024

Komentáře • 16

  • @Darkruss1991
    @Darkruss1991 Před 10 měsíci +2

    Your videos are very clear. Thanks a lot. YOu saved a lot of time for me

    • @System-Restored
      @System-Restored  Před 10 měsíci +1

      Happy to give you some time back, exactly why I put in the extra effort. For one I already had to do it, might as well help someone else.

  • @esmaeilalikhani6988
    @esmaeilalikhani6988 Před 10 měsíci +1

    your caption is very clear and i understood opc ua thanks❤

  • @nkosinathimazibuko8788
    @nkosinathimazibuko8788 Před 10 měsíci +1

    very clear demonstration i will try this application

  • @user-pn9gb2zr1n
    @user-pn9gb2zr1n Před 3 měsíci +1

    Thanks, it was usefull

  • @suriyat8773
    @suriyat8773 Před 11 měsíci +1

    Thank you

  • @jjjan13
    @jjjan13 Před 7 měsíci +1

    Good morning. My PLC is not a siemens (B&R in this case). I try to find this PLC online but it doesn't work. Do I have to do it with Imported Interface .xml? Thanks in advance.

    • @System-Restored
      @System-Restored  Před 6 měsíci

      Do the tools like UA Expert or SiOME function correctly? Is it an HMI or another processor as the client?
      Yes exporting the interface, and import it in B&R is the right next move it you can't browse it online. I would tend to think you maybe have something like passwords or certificates or endpoint URL with port numbers could be wrong. For example the address may not be what you think it is, or maybe you are dealing with a NAT?
      Then if nothing else, maybe a wireshark sniff can show what is actually attempting to happen.

    • @System-Restored
      @System-Restored  Před 6 měsíci

      When you use the client interface to search for other data using opcua, you probably failed to configure the properties of that client interface, which provides the IP address to each server you are trying to connect to. If you just do a search, you're probably missing the URI and port numbering. Wireshark it to see what is going out. I am certain you did ensure it pings right?

    • @System-Restored
      @System-Restored  Před 6 měsíci

      I believe you have configured the port number as you should in the client interface, but what you don't want to do is include it twice, otherwise, the search is not going to work, see here: czcams.com/video/nXUsnkgHsGk/video.htmlsi=Ani0AUCDxMkD9UO3&t=140

  • @Adrian-fn4sb
    @Adrian-fn4sb Před 9 měsíci +1

    Hi, I have a project from customer with configured users and passwords in User Menagment for OPC serwer in Tia Portal, and my question is did you know is it possible to get user password from Tia Portal project ?

    • @System-Restored
      @System-Restored  Před 9 měsíci +2

      Hi,
      No once passwords are typed they become asterisk out of view. Most project I seen have the password as the comment, which is bad security but a way to combat your current situation.
      You could go in there and put the password you like but do know any other connections using that username and password will need to also be reconfigured. Maybe try and turn off the certificates and wireshark sniff the connection for username passwords .Best of luck in your endeavors.