  • In this HVAC Training Video, I Show the Components, Wiring, and Operation of a Direct Spark Ignition System! I Discuss Power Inputs, Flame Proving, Ignition, and How it all Works! I Show the Common Problems and Troubleshooting of this Setup! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    Tools Used In The Video
    UEI DL489 Multimeter: amzn.to/47Fod5n
    Alligator Jumpers- amzn.to/2PxqJXn
    Magnet Jumpers- amzn.to/2PyKPQZ
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos
    • Gas Furnace Training C...
    • HOT SURFACE IGNITOR Tr...
    • NO HEAT? Top 10 Proble...
    • Explaining "Gas Furnac...
    • 7 Gas Furnace Installa...
    • 5 Gas Furnace Parts Th...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.com/show/74KXLz5...
    Apple Podcasts: podcasts.apple.com/us/podcast...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #directspark #ignition #flameproving #flame #powerinput #spark #ignitionsystem #troubleshooting
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Komentáře • 108

  • @zahedaminullah6934
    @zahedaminullah6934 Před rokem +16

    Great videos as always. Well explained and I love the way you laid out all your components. This helps all of us a lot. Keep up the good work as always!

  • @coldfinger459sub0
    @coldfinger459sub0 Před rokem +15

    I wish training videos like this were available when I was a kid since my dad forced me to learn at the age of 12 and we had to order books through snail mail or request our local library to order them which would take 5 to 8 weeks for delivery. Back before the Internet was invented..

    • @1984juant
      @1984juant Před rokem

      Greetings👋. Do this mean anybody can service their own furnaces? I dont like that prospect.

    • @THExBIGxBADxWOLF93
      @THExBIGxBADxWOLF93 Před 5 měsíci +1

      Better that way because you really learn compared to this I’ll learn and forget just because it was too simple

    • @coldfinger459sub0
      @coldfinger459sub0 Před 5 měsíci

      @@THExBIGxBADxWOLF93 it good for the simple ones who get over whelmed seen too many things that are spread out .
      Some students learn better when everything is like on one page in front of them .
      Have to teach different types of students learning abilities differently.
      Some students can learn just by reading words without ever seen an actual furnace .
      Other students literally have to put their hands on the pieces take them off and put them back together before they learn .
      It all depends on the type of student you are teaching .

  • @BeardGawd88
    @BeardGawd88 Před rokem +12

    I always double check power. Great stuff, my company doesn’t teach this stuff, glad i can learn on here!

    • @grashoprsmith
      @grashoprsmith Před rokem

      Isn't that sad

    • @5822huron
      @5822huron Před rokem +6

      There comes a point where you as a tech must educate yourself. Don't wait or expect any company to get you there.. Trust me! They wont

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Před rokem +1

      Most don’t because of high turnover, takes away profits and they’ll just be teaching their future competition.

  • @zproxiimiity7733
    @zproxiimiity7733 Před rokem +3

    I love the way you teach! Your wording is on point. Hands on is the cherry on top!

  • @jimbarron8688
    @jimbarron8688 Před 9 měsíci

    No need to look any further for a video covering direct spark ignition furnaces. This is the holy grail. Very thoughtful and thorough presentation.

  • @HANDYMANDAN51
    @HANDYMANDAN51 Před rokem +3

    Awsome , every heating service should view this,thanks.

  • @mathman0101
    @mathman0101 Před rokem +7

    Craig you are going to need a furnace book to complete the set of books you already have and your videos then act as a great complement. Always well explained and laid out.

    • @acservicetechchannel
      @acservicetechchannel  Před rokem +3

      Thank you so much!!! That last book took two years!

    • @mathman0101
      @mathman0101 Před rokem +2

      @@acservicetechchannel anything good always takes time and effort to plan and then write.

  • @jimmylanders2175
    @jimmylanders2175 Před rokem +5

    Great video Craig and very thorough.

  • @juanital.2608
    @juanital.2608 Před 9 měsíci

    You are This Old House crew worthy. Great job, great speaking voice. You'd be great on their show. This is exactly how they explain things & why i love it. You've got another new follower in me. Great job, keep it up! 👏👏👏

  • @stevencossaboon3237
    @stevencossaboon3237 Před rokem +3

    Great video Craig. Thank you.

  • @jed837
    @jed837 Před rokem +4

    Craig, you have wonderful videos for those coming up into the HVAC/R trade. Well explained . I’ve been in the trade over 30 years, and I’ve gotta say this is good stuff. Keep up the good work and happy new year!!!

  • @rammyfernando
    @rammyfernando Před rokem +2

    very beautifully explained

  • @gideonlord-adem
    @gideonlord-adem Před rokem +1

    Great experience with good explanations

  • @mouseley
    @mouseley Před rokem +1

    Great video, very well organized and laid out. Great lab setup.

  • @deanmartin1966
    @deanmartin1966 Před rokem +1

    Once again, excellent explanation. Thanks for sharing.

  • @Yeti808
    @Yeti808 Před 9 měsíci

    Amazing job explaining the operation of a spark ignition. Thank you boss man!

  • @christopherborner1139

    Craig, once again a great explanation! Thank you so much. You explain things so precise and simple. Love the video.

  • @RZeee..
    @RZeee.. Před rokem

    Great illustration. Thank you!

  • @coolramone
    @coolramone Před rokem +1

    Thanks Craig! This will help me fix my gas furnace that won’t stay lit for more than a few seconds. It’s probably the flame rod not sensing flame and either needs cleaning or replacing, but now I know how to test the flame rod, thanks to you. URDB (you are dee best!) :)

  • @davidwilliams729
    @davidwilliams729 Před 9 měsíci

    Love this guy! Thank you for making this video

  • @joshuaadkins9998
    @joshuaadkins9998 Před 6 měsíci

    Excellent tutorial. Great video! Thank you

  • @noahoyeah
    @noahoyeah Před rokem

    Wow! Very good video!

  • @panchobarajas3008
    @panchobarajas3008 Před rokem +1

    Good video thanks Craig

  • @estebancastro6297
    @estebancastro6297 Před rokem +2

    Gracias!! Well explained

  • @repairitdontwreckit4257

    Another excellent video. Thanks

  • @westsidehvac1097
    @westsidehvac1097 Před rokem

    beautiful video

  • @jaysingh-ho7eb
    @jaysingh-ho7eb Před rokem

    Great video! Thanks

  • @technician9722
    @technician9722 Před rokem

    Great video.

  • @victor.mnoriega3586
    @victor.mnoriega3586 Před 10 měsíci

    I really love your classes, Thank you.

  • @JA-vy1gp
    @JA-vy1gp Před rokem

    Great video !! Thank you

  • @Onatena
    @Onatena Před rokem

    Great video
    Thanks a lot 🙏

  • @manuelcastillo8472
    @manuelcastillo8472 Před rokem

    Thanks nice and clear

  • @waltherherrera67
    @waltherherrera67 Před 8 měsíci

    Excelente muy bien Gracias

  • @indiantraveller194
    @indiantraveller194 Před rokem

    Great job sir 😘🙏

  • @ivanl8613
    @ivanl8613 Před rokem

    exelent videos !!!

  • @sonle-fz1xb
    @sonle-fz1xb Před rokem

    Thank you so much

  • @germanrivas9925
    @germanrivas9925 Před rokem +1

    Thanks!

  • @bill98778
    @bill98778 Před rokem

    Great video!!! I wish if you would have a video about domino’s pizza chain oven, thank you Craig and happy new year 2023🎉

  • @takleung7130
    @takleung7130 Před rokem +2

    24V into the ignition module but 120V out to the sense wire. Is there a step-up transformer in the module? Am I missing something?

    • @pointblankmatt6580
      @pointblankmatt6580 Před rokem +1

      i mean it also provides 10000 volts for the ignitor. was curious about this as well. has to be something internal in the ignition control

  • @user-mo7hu1yb8l
    @user-mo7hu1yb8l Před rokem

    Thanks

  • @paulthibodeau1269
    @paulthibodeau1269 Před 8 měsíci +1

    Great video! I have a Rheem direct spark ignition unit. The unit would short cycle where the burner would light and burn for about 4 seconds then shut off. After a few attempts, it wouldn't do anything for about an hour. I couldn't call anyone because of my work schedule and it being a holiday week also. I took a shot and ordered a new dual electrode spark ignitor from Amazon, which showed up in only 2 days. After I installed it, my heater works perfectly. Was this just a coincidence or does the spark ignitor have something to do with the flame rectification process? (it was labeled ignitor/flame sensor) Thank you.

  • @d.c2123
    @d.c2123 Před rokem

    BRAVOOOO!

  • @davidnecky8524
    @davidnecky8524 Před rokem +1

    Excellent video as always!

  • @rj.parker
    @rj.parker Před rokem +1

    The only clarification I would offer is flame sensing microamps (ua) is present on the sense wire as well as the ground wire. You need both to complete the circuit.

    • @chrisdeanndavison3626
      @chrisdeanndavison3626 Před rokem +1

      True, and I believe Craig covered this starting at about 8:00 through 10:00.

  • @aifrisyad7491
    @aifrisyad7491 Před rokem

    great video…suggest more video about intermittrnt gas valve with ignition control…thanks anyway

  • @martini4620
    @martini4620 Před rokem

    A couple months ago we installed a 95% Ruud furnace.It is now rusting very bad , the inside of the inducer collected some orangish rust. Even drain coming out is orange/rusty. Has correct gas pressure. Has both exhaust and intake going outside. RUUD Model # R95TC0701317MSA

    • @Yeti808
      @Yeti808 Před rokem

      Proper duct sizing?

  • @aidanpeluso8350
    @aidanpeluso8350 Před rokem

    Can you make a video explaining common/neutral wires. What they are, why they are there and what they do?

  • @YTsux24-7
    @YTsux24-7 Před rokem

    Frankenfurnace by AC Service tech!
    Awaiting UL approval...

  • @mohammedalobaidi9981
    @mohammedalobaidi9981 Před 8 měsíci

    👏👏👏

  • @jesparza602
    @jesparza602 Před rokem +2

    I've been looking for a video like this! As always, your explanations are clear and succinct. Thank you! Do you by chance have a book where you detail this?

  • @marcosaguilera1760
    @marcosaguilera1760 Před 3 měsíci

    Good morning, excellent explanation and I like your videos, you know a lot, I have a question about my furnice, when it calls to turn on the sparks it clicks for 30 or 40 seconds and it turns on and works well, what could be the reason, thank you

  • @Sightthrough
    @Sightthrough Před rokem +3

    I'm curious about the voltage on the flame rod, when we test flame rods in the field we always measure the signal from the rod in Microamps DC, I didn't realize there was also A/C voltage on the flame rod, so the signal from the flame rod to the board is measured in microamps, DC, but the rod also has a potentially high A/C voltage on it? Could you share more about this?

    • @chrisdeanndavison3626
      @chrisdeanndavison3626 Před rokem +6

      It is flame rectification. I know I'm not explaining this by the book, but basically, the AC voltage present on the flame rod is rectified by the flame to DC. It is just a phenomenon that happens when AC voltage is in a flame. The flame conducts a very small amount of DC current to ground, this is the uA DC that we measure. This is why the ground on a furnace is just as important as the hot and neutral. Also, rusty burners can inhibit the current flow. 14:30 Craig explains this pretty well.

    • @Sightthrough
      @Sightthrough Před rokem +1

      @@chrisdeanndavison3626 Thanks! My fault for posting the question before finishing the video.

    • @coolramone
      @coolramone Před rokem

      So there are ac micro amps AND dc micro amps running through the flame rod, and which one is being measured by the pc board, ac or dc?

    • @jynnandtonnyx
      @jynnandtonnyx Před rokem +4

      @@coolramone the way I understand it is : there is AC power (different than voltage) available to the flame rod. When the circuit is closed by the flame, the AC power is rectified by the flame to a small DC circuit which can be measured in micro amps. The flame is the switch.

    • @rj.parker
      @rj.parker Před rokem

      @@coolramone dc microamps

  • @odishoodisho4904
    @odishoodisho4904 Před 8 měsíci

    If the module go bad and need to be replaced should we have to look the same one or there is an universal will work with all models ? And it needs to do some changes or just we can put it direct without any changes thanks in advance

  • @Kh2456
    @Kh2456 Před rokem

    Having issues with my raypak pool heater. I have identified it down to a flame rectification issue as the pilot lights well and doesn’t activate the main gas valve for burners. Today I attempted to test the negative for micro amps (disconnected from gas valve) I connected it in series and couldn’t get a micro amp reading. When unplugging I got electrocuted by touching one probe of the multimeter when the positive was plugged into the negative. Why would the negative be carrying an electrical charge from the motherboard? Thanks

  • @edwardgarza5104
    @edwardgarza5104 Před rokem +1

    Is there a step up transformer inside that board to be able to send 120 vac to the flame sensor?

    • @caru3257
      @caru3257 Před rokem

      120v is present at the board and it doesn’t require a step-up transformer.

  • @MrSnomanjankens
    @MrSnomanjankens Před rokem

    I had a headache yesterday with a direct spark ignition furnace, except it had a pilot ignition assembly with a single flame rod.
    The ground wire was hanging on by a thread & was enough to not not give it proper ground.
    Also the pressure switch was constantly opening and closing since the inducer is on its was out only pulling .67” of WC on a .70” WC switch.
    The arching from the spark ignition due to the opening/closing of the pressure switch I think may have caused the pilot assembly ground to fail? 🤷

  • @Morbidhouse
    @Morbidhouse Před 6 měsíci

    I'm getting a voltage drop in the MC terminal, when the wire is connected to the gas valve it is only reading 15vac however when it is disconnected from the gas valve it reads 26vac. The pilot is sparking and lighting and blower is turning on however this drop in voltage seems to be preventing the burners from coming on. Would it be the gas valve or the ignition control module at fault?

  • @RC-Heli835
    @RC-Heli835 Před 5 měsíci

    My old 1986 System does not seem to have a flame rod. It just has the old school honywell intermittent igniter and sparker and the fan limit switch.

  • @eloy09
    @eloy09 Před rokem

    I was troubleshooting a lochinvar water heater. Same principle though, what happening is it will prepurge and trial for ignition again and again. What should be the problem? No flashes

  • @user-jp5py6ry7t
    @user-jp5py6ry7t Před 3 dny +1

    When the AC voltage is sent down for the sparking across the the probes(or probe and burner ) to the ground to make the circuit , the flame sensing probe is also sending ac down to the flame to convert to DC for same ground to prove? Is the flame rectification proven after the sparking stops , like a window of time ? As it would be AC from the spark and DC from the flame proving or am I getting confused ? Or is it possible to sense both at the same time from the same ground ? Anyone’s insight is helpful tia

  • @light0000
    @light0000 Před 8 měsíci

    Is it possible the flame sensor is bad and wouldnt let my HSI igniter to glow?

  • @Purifiedinfire
    @Purifiedinfire Před 6 měsíci

    My furnace has a control board for everything.
    The inducer fan goes, the spark ignitor clicks, the gas valve opens in short few second spurts a few times but it won't light. While doing this the furnace clunks or clicks like a gas valve or relay.
    The best I can gather it's a rusty buner tube not getting ma back to ground or a bad ground and it cutting the gas quickly then retrying a few times before giving up for a few minutes.
    The part I don't understand is why the clunking or clicking.
    The furnace doesn't do this all the time just sometimes.

  • @VictorGarcia-ri6uw
    @VictorGarcia-ri6uw Před rokem

    Where can I buy the spark igniter wire?

  • @imbobbymuddah
    @imbobbymuddah Před 2 měsíci

    What about a faulty module? How can you troubleshoot for that

  • @PBS-nm1uu
    @PBS-nm1uu Před 5 měsíci

    bad camera angle but good video

  • @mplscarsales6652
    @mplscarsales6652 Před rokem

    Hi my furnace always had at least 1 click I hear before start up and fan kicking on but lately I been hearing 2-3 clicks/Spark before the blower motor kicks on is that normal ? Same clicks I hear in your video at 8:16 but yours clicks/sparks much more .

  • @christiansnyder1746
    @christiansnyder1746 Před rokem +1

    Craig I have a stupid question
    If there is only 24 V going to the ignition module, how does it produce high voltage?

    • @acservicetechchannel
      @acservicetechchannel  Před rokem

      There is a low voltage to high voltage transformer under the hood of the icm.

  • @EC20121
    @EC20121 Před rokem

    Flame roll out switch, cannot find a replacement for mine, keeps tripping can you help me find a replacement for it? Thank you

    • @jimbarron8688
      @jimbarron8688 Před 9 měsíci +1

      A flame rollout that is constantly tripping is usually a sign of a cracked heat exchanger and is very bad news. These switches are generally very reliable so you'd be fortunate if a replacement solved your issue. A CO detector near the burners when it's running might show high CO as would a washy flame pattern that rolls out when the main blower powers on.

  • @dennisnoone7427
    @dennisnoone7427 Před rokem

    why does a new ds845 dont have a terminal for fame sense anymore? the one you have still have one, but if i google for a new one it doesnt

  • @mr.spliffaddikts9548
    @mr.spliffaddikts9548 Před rokem

    I have a question ?? Is there a device tool that a Hvac tech can u to plug on fan motor’s n control board to get a diagnosis besides a (multi meter ) to test all components

    • @mr.spliffaddikts9548
      @mr.spliffaddikts9548 Před rokem

      It’s there any please link it to the comment section please n thank

    • @chrisdeanndavison3626
      @chrisdeanndavison3626 Před rokem

      @@mr.spliffaddikts9548 The short answer is no, not really. Most furnaces for the last 30 years do have some sort of onboard diagnostics. When there is a problem, we count blinking lights on the control board and then find the key to what the blinking lights mean to narrow our search for the problem. However, some upper-end units do have more sophisticated means of diagnosing the issue. I service WaterFurnace geothermal units and use an Aid-Tool analyzer on the 3 Series and 5 Series units. Apparently, the 7 Series units can be diagnosed through an internet connection, but I have no direct experience with them. The analyzer can provide a lot of information about how the unit is operating and what issues it might have had or is currently having. Much better than blinking lights.

  • @windturbineclimber5412

    How does it get up to 10000 volts?

  • @rodgraff1782
    @rodgraff1782 Před rokem

    Are there manufactures who are still using DSI. I thought everyone had switched over to HSI quite a while ago.

  • @OneLeggedTarantula
    @OneLeggedTarantula Před 8 měsíci

    I didn't know they made these, but was just thinking what a waste of power the old glow ingiters waste.

  • @zogonet
    @zogonet Před rokem

    hello, can you provide Polisz subtitles on your channel

  • @ausseamore8386
    @ausseamore8386 Před 8 měsíci

  • @EC20121
    @EC20121 Před rokem

    Or why would it keep tripping?

  • @CecilMerrell
    @CecilMerrell Před rokem +1

    Here is a great video that goes into detail about the flame rectification physics and how flames can act as a diode that basically makes a half wave rectifier ->
    czcams.com/video/FjrzbqFDnAw/video.html

    • @CecilMerrell
      @CecilMerrell Před rokem

      Additionally, looking into Townsend Discharge is an interesting physics rabbit hole.