INSTALLING 15KW SOLAR PV SYSTEM "Start to Finish "

Sdílet
Vložit
  • čas přidán 9. 09. 2024
  • This video will show you how to install 15KW Solar PV System and help you understand how the system operates.

Komentáře • 169

  • @abdulrahmanmuhammad6205
    @abdulrahmanmuhammad6205 Před 4 měsíci +9

    Honestly when we talk of proffessional work this is a very good example. Kudos to the camera man and the editor. I hope to see more of videos like these on this page.❤

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +3

      Thanks Muhammad really appreciate your wonderful comment and by the way I am the camera man and the editor.

  • @austinsagba7098
    @austinsagba7098 Před 4 měsíci +1

    Thanks. I appreciate the fact every beginner can follow up and understand the step by step approach to I stalling a solar system form the video. Great job.
    Great team. Top notch Professional work.

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +1

      Thanks Austin really appreciate it

  • @wnderjuan2344
    @wnderjuan2344 Před 3 měsíci +2

    Very Professionally done! You deserve to have many more clients! Hello from Manila!

    • @DNC2.0
      @DNC2.0  Před 3 měsíci +1

      Thank you so much bro really appreciate the positive energy

    • @wnderjuan2344
      @wnderjuan2344 Před 3 měsíci

      @@DNC2.0 Im studying solar now and this video really inspires me! Thanks bro

    • @DNC2.0
      @DNC2.0  Před 2 měsíci

      @@wnderjuan2344 you're welcome bro

    • @hakeemkareem3211
      @hakeemkareem3211 Před měsícem

      @@DNC2.0 Do you have a branch in Lagos? Can you please post a contact e-mail or number or website?

  • @sushanthsrkr
    @sushanthsrkr Před 3 měsíci

    Thats what I call the informative video. All my installation doubts are cleared.

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Thanks mate always happy to help

  • @simonemmanuel9734
    @simonemmanuel9734 Před 4 měsíci

    Dem. This is standard. Every tolls are complete. When it comes to professional I give it to you guys. I wish u guys are in Nigeria I would have given you guys job instantly

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      Thanks bro really appreciate it but we're located in the Gambia 🇬🇲

  • @atobsky
    @atobsky Před 3 měsíci +5

    The panels themselves should be grounded to Earth ..The SPD is not enough especially in a large setup like this

  • @eddyidemudia7356
    @eddyidemudia7356 Před 3 měsíci

    Nicet to see this Guys doing the Job with passion

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Thanks mate really appreciate the possitive comment 👍

  • @powerwall
    @powerwall Před 2 měsíci

    Great.We have wall mounted battery as well.

  • @mbyesowe7828
    @mbyesowe7828 Před 4 měsíci

    Good job young men. Am proud 👏

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      Thanks sowe really appreciate it and maybe it's all because of the calculations we did in class 😂

  • @madouceesay2151
    @madouceesay2151 Před 4 měsíci

    Thank you so much bro the installation is so neat and easy to understand ❤

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      You're welcome bro

  • @ikediashitimothyonuorah417
    @ikediashitimothyonuorah417 Před 4 měsíci

    Omo see clean job! I shall definitely call you guys to come install my EG4 18kpv soon

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      Thanks really appreciate it but which country are you located

    • @larutadelosmilagro3706
      @larutadelosmilagro3706 Před 4 měsíci

      Felicidades jóvenes buen trabajo

    • @meilyn22
      @meilyn22 Před 4 měsíci +2

      18KPV can only be used in the United States and Canada or countries with 120v/240v and 60hz split phase. If you live in Nigeria, that inverter isn't for you. You need a 230v single phase inverter with 50hz. You need an inverter with L1 and Neutral. Not one with L1 and L2. Understand what you are doing before buying something you won't be able to use without a transformer.

  • @aglactv7893
    @aglactv7893 Před 3 měsíci +2

    Neat job but the DC cable size for the Battery Bank is too small, cable size for the 3 battery set up should not be less than 50mm-75mm.....because when the battery is drain and is set to charge the cable temperature will slightly increase and might not the able to withstand the charging current of the 3 storage devices

  • @user-xe7bw4gq1f
    @user-xe7bw4gq1f Před 3 měsíci +1

    Nice job!❤

  • @y_Tech0
    @y_Tech0 Před 2 měsíci

    A very nice layout man.
    May I know if your battery do get fully charged. Your installed capacity from the pv 10800w to charge 45kwh battery may take time. Aside you powering your load from it you still can’t harness it all and on a bad weather days. You may not get to harness 2kw from the pv.

  • @adewumisesan26
    @adewumisesan26 Před 3 měsíci +5

    You made a mistake why are you still backing your battery with external breaker what of if the breaker trip off it will remain only PV voltage on the system are you know only PV voltage can damage the system without seen battery

    • @chiemezieanaebonam9898
      @chiemezieanaebonam9898 Před 3 měsíci +2

      Not a mistake
      This is Ivem that means it can work without batteries
      External breakers are recommended by the manufacturer

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Thanks mate

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      You can even use only the panels without batteries with these inverters. The Batteries are just there to store energy which is to be used later on.

  • @samuelkunsauka
    @samuelkunsauka Před 3 měsíci

    This is smart job. Keep it up

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Thanks, will do!

  • @bergertshitenge1375
    @bergertshitenge1375 Před 3 měsíci

    I really appreciated your installation, it's great especially the PV support used, is it possible to share with us the lengths of your PV supports and the weight of the concrete blocks used.
    I am also an engineer in the solar field thank you

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Yes, of course
      Oh alright thats pretty cool the dimensions of the frame are as follow. The Base angle bar is 1m 76cm, the long vertical angle bar is 80cm, the shorter angle bar is 40cm, and the top sloping angle bar is 1m 76cm. Keep in mind that the panels we use are 1m 96cm × 1m6cm alright i hope that helps

  • @Sindhu_Jatt
    @Sindhu_Jatt Před 3 měsíci

    *Waaooo Nice work. But there is no gap between the panels, a strong wind can pulled it out.*

    • @DNC2.0
      @DNC2.0  Před 3 měsíci +1

      Thanks mate, I don't think it can

  • @adanbouzoua
    @adanbouzoua Před 4 měsíci +1

    Good job!

  • @user-qb6ro2dy5b
    @user-qb6ro2dy5b Před měsícem

    Great job

  • @thierrymukadi6475
    @thierrymukadi6475 Před 2 měsíci

    Good job and thanks

    • @DNC2.0
      @DNC2.0  Před 2 měsíci

      Thank you too, and you're welcome

  • @nnekaenweliku917
    @nnekaenweliku917 Před 4 měsíci

    Good job guys. I appreciate the simplicity and neatness of the job. I'm thrilled with the panel installation especially that you had everything custome made and easy to install. A quick question though, how did you fix the concrete or brick to the roof floor?
    Wish you were in Nigeria.

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +1

      Thanks bro really appreciate it. The concrete bricks aren't fixed to the roof floor but instead we just placed it because the weight of all the concrete bricks combined is enough to securely hold the panels.

  • @keyable
    @keyable Před 3 měsíci

    Great work, would be nice to see the schematics of the project 🙏

  • @ousmanamnjie9869
    @ousmanamnjie9869 Před 4 měsíci

    Nice and clean job my bosses

  • @jonesnyuykighan6300
    @jonesnyuykighan6300 Před 3 měsíci

    Excellent job

  • @culmani
    @culmani Před 2 měsíci

    a job well done. kudos. can ds ivem5048 carry a 1hp ac waterpump with only solar panel, no battery?

  • @Jo_Fidel
    @Jo_Fidel Před 2 měsíci

    Nice job

  • @venceslaswembenyui1551
    @venceslaswembenyui1551 Před 3 měsíci +1

    i really did enjoy the work but please can you help me with the calculation steps

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Which calculations are you refering to

  • @lukeaaronpower448
    @lukeaaronpower448 Před 4 měsíci

    Good installation work Sir . Out of curiosity which Installation regulations did you use to install this system ? I might have few questions i need to ask

  • @muhammadriaz6341
    @muhammadriaz6341 Před 2 měsíci

    ❤ Excellent 👌

    • @DNC2.0
      @DNC2.0  Před 2 měsíci +1

      Thank you! Cheers!

    • @muhammadriaz6341
      @muhammadriaz6341 Před 2 měsíci

      @@DNC2.0 you are welcome to Pakistan 🇵🇰

  • @morgenmachote9503
    @morgenmachote9503 Před 3 měsíci

    Good job

  • @pamprorecords2440
    @pamprorecords2440 Před 4 měsíci

    wow great job, it’s very great. Please can you lead me a little on how you made the holes in the bricks to be able to fix the iron bars on them?
    And what kind of bricks are they exactly?
    thank you and I can't wait to see your response

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +2

      The bricks are custom made cement bricks with a length of 40cm, width of 16cm and a height of 19cm. To make the bricks you should make a custom made frame using these measurements then then mix the cement with sand and pour it in the frame you made then you take two bolts and put the heads in the wet cement, and measure the distance between the two bolts for consistency on the other bricks. After you made the bricks you measure the point of the two bolts on the bricks and drill the same measurements on the metal bars so that you can easily slide it in then tightening it with a nut securely. Alright i guess that answers your question and thanks for the positive comment by the way. Peace out✌️

    • @pamprorecords2440
      @pamprorecords2440 Před 4 měsíci

      Thank you for your reply @@DNC2.0

  • @hussaini24
    @hussaini24 Před 4 měsíci +1

    Abeg my question is, Does inverter has efficiency rating like d way panel does? E.g I can only get 3kva from an inverter of 5kva?
    Clean installation guys, gudus👏

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +1

      No you can't get up to 5000W in a 5KW inverter because you have to take into consideration the power factor which most inverters have 80 percent of or 0.8

    • @meilyn22
      @meilyn22 Před 4 měsíci +1

      They aren't 100% efficient, just FYI. Most of them are around 90-94%, efficient, which is good.

    • @meilyn22
      @meilyn22 Před 4 měsíci +1

      They also have continous and surge ratings. Inverters lose efficiency because of heat, conversions, and how much power they take to run. A 5kva inverter can never give you 5kva. The highest it can produce at its best is 4.5 - 4.8kva. Except the manufacturer is accounting for those inefficiencies.

    • @meilyn22
      @meilyn22 Před 4 měsíci

      Knowing Felicity, I can tell you their claims are mostly BS. So their inverters will be less than 90% efficient. They aren't honest.

    • @atobsky
      @atobsky Před 3 měsíci +1

      Any appliance rated in KVA is just a marketing strategy to make the appliance look bigger than what it actually is, after all, your TV eg is not rated in " KVA but WATT... Most KVA rated inverters have a power factor of 0.8 so, for example , an inverter rated at 5KVA PEAK WILL PROBABLY BE A 4KW or 4000Watts .... So when buying inverters , look out for the ones in Watts not KVA. Most inverters made in Europe or for European Markets are rated in WATTS and they also come at huge prices

  • @ekedonz
    @ekedonz Před 2 měsíci

    Why did u use 2 dc breaker for the pv. Why not go straight to the surge protector then to the breaker which will pass to the inverter. I don't mean to challenge. I'm always trying to learn.

    • @DNC2.0
      @DNC2.0  Před 2 měsíci

      Thanks bro for the positive energy. Yeah the first DC breaker serves as a fuse to protect the inverters from over voltage ⚡️ from the panels incase of surge,and the second one just serves the purpose of an isolator

  • @azisebance7222
    @azisebance7222 Před 3 měsíci

    Sono molto fiero di voi bravi fratelli miei

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Thanks am proud of you too✌️💯

  • @yahayajamiu9041
    @yahayajamiu9041 Před 4 měsíci

    This is a very good job. Please what is the name of the terminal you linked all the batteries to called? Made the installation so neat and free of cable joints

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +3

      Its a 4 post power distribution busbar. You can search it on Google for more information, and thanks for the comments

  • @elvisbestroyal80
    @elvisbestroyal80 Před 3 měsíci

    In the setup was each inverter and battery connected to separate loads in the house
    Like each controls his own load ?

    • @DNC2.0
      @DNC2.0  Před 3 měsíci +1

      No the the inverters were connected in parallel to increase the overall output power and the batteries as well were connected in parallel to increase the overall capacity. They are all collectively controlling one big load

    • @elvisbestroyal80
      @elvisbestroyal80 Před 3 měsíci

      @DNC2.0 oh I see. Thank you

  • @latifsalehadam71
    @latifsalehadam71 Před 2 měsíci

    Hi bro , here at the end , all 3 inverter output is connected in paralel to distribution box ??

    • @DNC2.0
      @DNC2.0  Před 2 měsíci

      Yeah all the inverters are connected in parallel then to the distribution board

    • @latifsalehadam71
      @latifsalehadam71 Před 2 měsíci

      So all 3 inverter give single phase 220v , what about if i connected each inverter to its single phase so i get use in 3phase house . Is it possible ?

  • @atobsky
    @atobsky Před 3 měsíci

    I did not see an RCD anywhere in your installation ? Well laid out installation

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      The RCD is installed in the main distribution box which unfortunately wasn't shown on camera

    • @atobsky
      @atobsky Před 3 měsíci

      @@DNC2.0 Even at that , the inverter should have its own RCD and this is important to show in your installation videos so viewers are convinced you know what you are doing and that you take safety importantly...there should be an RCD , a Type B or Type F , after the inverter before the Distribution Board

    • @Opsolar
      @Opsolar Před 3 měsíci

      Naija una too the find error abeg

    • @atobsky
      @atobsky Před 3 měsíci

      @@Opsolar it is from the errors and feedback, improvement and better delivery of service is generated... Errors and feedbacks are beautiful things

  • @mauriceamollo8538
    @mauriceamollo8538 Před 3 měsíci

    Did you wire the batteries in parallel or series? what are the capabilities per batteries?

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      We wire the batteries in parallel to increase the overall capacity. Each battery is powerful enough to power a small house

  • @dannyoliver7953
    @dannyoliver7953 Před 4 měsíci

    Could you tell me were you getting grounded mount for panels from also solar panels

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      They were custom made bricks with bolts sticking out to easily tighten the metal frames on the bricks

  • @dannyoliver7953
    @dannyoliver7953 Před 4 měsíci

    Gm can you give me some measurement and the solar rocking system plus the dimension of the solar panel. I would appreciate it thank you.

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      The dimensions of the solar panels are 1960×1060×35mm or 196×106×3.5cm

  • @fortniegodking5776
    @fortniegodking5776 Před 3 měsíci

    what type of inverter did you use and what's the spec of them. Thanks

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      It's a 5000W, 48V, 119A Felicity inverter

  • @pipoy4886
    @pipoy4886 Před 4 měsíci

    syperb work brother. There is no SCC in your set up. as i understand the solar is directly connected to your inverter and the inverter has battery port for its dc output?

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      Thanks for the comment mate. The panels are not directly connected to the inverters but instead they're connected to a Surge Protective Device first before reaching the inverters

    • @pipoy4886
      @pipoy4886 Před 4 měsíci

      @@DNC2.0 i see. thats what im talking about there is only protective device between the two. kudos

  • @benedictokpala5846
    @benedictokpala5846 Před 3 měsíci

    Great job bro. Please which software did you use for the wiring diagram ?

    • @DNC2.0
      @DNC2.0  Před 3 měsíci +1

      I didn't use any software for the wiring diagram. I draw it myself

  • @IEJonah
    @IEJonah Před 3 měsíci

    Do you carry out work in lagos??... and also how much will the 15kwh battery cost now?

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      We are located in the Gambia but if you need our service we can come and install for you. The batteries are each costing about $1810 you can check it on alibaba for more information

  • @odoohub5010
    @odoohub5010 Před 3 měsíci

    I wss expecting you use ferrules to avoid loose contacts over time

  • @IsraelGebremarime
    @IsraelGebremarime Před 3 měsíci

    NICE🥰🥰

  • @sunenergytechnologies4918
    @sunenergytechnologies4918 Před 4 měsíci

    why you use dual breaker with SPD.. ? instead of single

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      We use it for added protection

    • @i-TEQ_power
      @i-TEQ_power Před 4 měsíci

      You should have used double SPD instead, if you are actually keen on Added protection.
      Peace!!!

  • @dannyoliver7953
    @dannyoliver7953 Před 4 měsíci

    Thanks for the help?if you can get the custom metal frame dimensions that holds solar panels.I’ll pay you for it, I’m trying to setup like yours

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Oh alright thats pretty cool the dimensions of the frame are as follow. The Base angle bar is 1m 76cm, the long vertical angle bar is 80cm, the shorter angle bar is 40cm, and the top sloping angle bar is 1m 76cm. Keep in mind that the panels we use are 1m 96cm × 1m6cm alright and no need for you to pay bro am here to help anytime you need me

  • @JumaMonyluak
    @JumaMonyluak Před měsícem

    How many solar panels did you installed

    • @DNC2.0
      @DNC2.0  Před 19 dny

      In this project we installed 24 panels

  • @user-ph6cp2ox7u
    @user-ph6cp2ox7u Před 2 měsíci

    Please the pv is it potential voltage or different things

    • @DNC2.0
      @DNC2.0  Před 2 měsíci

      I don't understand the que3

  • @user-kw4fq5hj3z
    @user-kw4fq5hj3z Před 3 měsíci

    The company specializes in the production of solar photovoltaic bracket galvanized pipes, durable and anti-corrosion, with a service life of up to 25 years, good quality and low price. Welcome to cooperate.

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Thanks mate 👍

  • @sunenergytechnologies4918
    @sunenergytechnologies4918 Před 4 měsíci

    is this right angle ..? for opposit pannels

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +1

      Yeah we carefully studied the movement of the sun to efficiently install the panels to harvest maximum sun rays

  • @JumaMonyluak
    @JumaMonyluak Před měsícem

    Send me the diagram of this connection it’s really professional

    • @DNC2.0
      @DNC2.0  Před 19 dny

      I just posted the wiring diagram for my latest video on my community post so you can check it there

  • @theo2378
    @theo2378 Před 3 měsíci

    Where was this installed?

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      In the Gambia 🇬🇲

  • @NetZeroghana
    @NetZeroghana Před 2 měsíci

    Beautiful, which country?

    • @DNC2.0
      @DNC2.0  Před 2 měsíci

      Gambia 🇬🇲

  • @ChandrashekarCN
    @ChandrashekarCN Před 4 měsíci

    💖💖💖💖

  • @Mr-Nun
    @Mr-Nun Před 3 měsíci

    Neatly done job. ❤ how can I contact you for a jobs in Lagos Nigeria.

    • @DNC2.0
      @DNC2.0  Před 3 měsíci +1

      We're located in the Gambia 🇬🇲

  • @Ghedi1965
    @Ghedi1965 Před 4 měsíci

    could you please share the 15kw package contents?

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +1

      We bought 24 panels of 450W.
      3 inverters of 5KW to be later connected in parallel to increase the overall output power to 15KW.
      3 batteries of 15KWH 51.2V each to be also connected in parallel

  • @MsLewisky
    @MsLewisky Před 3 měsíci

    Plz how can I get that bus bar for battery

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      You can get it by ordering it on the interet or getting it from an electrical shop

  • @mauriceamollo8538
    @mauriceamollo8538 Před 3 měsíci

    What is the size per batteries?

    • @DNC2.0
      @DNC2.0  Před 3 měsíci +1

      The Batteries are 15KWH 51.2V lithium ion batteries

    • @mauriceamollo8538
      @mauriceamollo8538 Před 3 měsíci

      So how many solar panels are needed to charge one batterie in this setup?

  • @AnsoumanaBiaye-ej1jn
    @AnsoumanaBiaye-ej1jn Před 4 měsíci

    Vous êtes dans quel pays

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Am in a country called Gambia 🇬🇲

  • @ota-ke
    @ota-ke Před 4 měsíci

    How much for this exact system

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      I don't really know the answer to that because the home owner ordered the materials from china

  • @obichukwuebukajames1209
    @obichukwuebukajames1209 Před 3 měsíci

    Are u guys in Nigeria??

    • @DNC2.0
      @DNC2.0  Před 3 měsíci +1

      No we are located in the Gambia

  • @technotemka
    @technotemka Před 3 měsíci +1

    Колхозят, где опрессовка или пайка? 😢

    • @DNC2.0
      @DNC2.0  Před 3 měsíci

      Soldering was not needed but crimping was done behind the scenes

  • @gitsingelenaratsadaolur4819
    @gitsingelenaratsadaolur4819 Před 3 měsíci

    DC 😊Cable connectıon not safe

  • @1982757
    @1982757 Před 4 měsíci

    where are you located

    • @DNC2.0
      @DNC2.0  Před 4 měsíci +1

      Am from the Gambia 🇬🇲

  • @onimisilovesonmusic4548
    @onimisilovesonmusic4548 Před 4 měsíci

    Ur panels will have too many shades

  • @plantsolar1436
    @plantsolar1436 Před 4 měsíci

    inverter should not attached close to wall

    • @DNC2.0
      @DNC2.0  Před 4 měsíci

      Thanks bro

    • @Heimatar
      @Heimatar Před 3 měsíci +1

      Yes it should

    • @Heimatar
      @Heimatar Před 3 měsíci

      And they made relatively safe distance from each other

  • @aidamacayan430
    @aidamacayan430 Před 3 měsíci

    Not good installation not using terminal lugs no quality. Trash bin

  • @Heimatar
    @Heimatar Před 3 měsíci

    This is bad because only 1 inverter was enough with those amount of solar arrays the customer trusted you and your calculation otherwise good job.

    • @Opsolar
      @Opsolar Před 3 měsíci

      No 1 inverter isn't enough, the building has a lot of loads and getting an higher inverter will require 96v

    • @Heimatar
      @Heimatar Před 3 měsíci

      @Opsolar what on earth will he use more than 22 amp and continues 5kw in home residence

  • @IngBey-5710
    @IngBey-5710 Před 3 měsíci

    Nice job

  • @topreyalite
    @topreyalite Před 3 měsíci

    Good job

  • @savageolatunde6731
    @savageolatunde6731 Před 4 měsíci

    Good job