3 Phase Panel Change
Vložit
- čas přidán 12. 02. 2024
- Welcome to the final touches on this warehouse that was started back in June. We finished our rough in by mid-June and are finally able to get started on the finishes. We changed this 3 phase main breaker to a 3 phase main lug because there was a disconnect after the meter. Even tho this panel has no 3 phase equipment or motors connected the customer didn’t wanna eliminate the third phase in case they need it down the road. This panel took about 3hrs to change and was definitely a pain but it’s done! Onto the next! #femaleelectrician #electrican #electrician #lextheelectrician #construction #commercialelectrician #bluecollar #electricianlife #fypシ #milwaukeetools
I'm 73. Electrician all my life. I've worked with guys. That couldn't keep up with you. Wish we had more workers like you
Please put the dead front on before you turn new breakers on for the first time. Arc flash is a nasty burn and can leave permanent spots in your vision. I'm way more worried about getting my skin and eyes burned than I am getting shocked. But amazing job. Cutting the conduits with the feeders still inside is a great skill to have!
You are a warrior, and are too good for this type of cheap customer. Hopefully you got a good amount for your extra great work!🌿🌸
People like you is why “snobs” exist
That was amazing work, Lexi! What a dramatic improvement!
Love the detail and the work you put into this video. New panel looks awesome!
Cutting those pipes with a hackzall is like playing with fire. I’ve nicked the wires too many times. I’ve found sometimes you can slip a 1/2 piece of emt inside bigger pipes or use a copper tube cutter. Both of these have been golden for cutting pipe with wires in it.
Klein Tools has a hand conduit cutter looks the same like plumbers have their copper tube cutters. it is up to 1" diam. Nice tool and it even cuts RMC
Cut a piece of PVC in half length wise, than slide it down the conduit. Adjust it around as you GENTLY cut.
@@jonnybergin7711 Got one of those my self years ago, well worth the money!
Problem with tubing cutters they always leave a turned in rough circular edge that is very hard to remove from empty steel EMT. Would have pulled conduit back to coupling then cut the empty conduit & debur the edges. Have used the old panel in place and used it as a splice box to feed new panel.
Just get a deburring tool. Small curved blade on a handle that rotates as you work it around. Still a chore but better than the alternatives
Nice job. Thank you for sharing your knowledge.
Wow. Gorgeous panel installation Lexi. Bravo.
Outstanding work! Just look at that finished panel. 😍
What an improvement! Awesome work, Lexi!
Your work is outstanding!!! Keep it going love tour videos. 👍👍👍
Amazing job here Lexi thanks for fliming the video of this
Great job. Thanks for sharing...
Great Video. Thank you for sharing
Love your work and doing with your nails, amazing!!
Would of loved to get an "IR" scan of that panel while it was hot, & with all the loads fired up! Just to see all the hot spots from those loose wires. 🔥🔥
Perfect job and and it looks absolutly professional
I was going to say no more than 4hrs so good job I would tell my guys that’s all the time they would have, and I’m glad that you explained the main breaker change to main lugs and how your bonding was not right
I love hearing your though process.
Great work 👍
Hi from Australia. Very nice job so tidy. Talking to yourself is thinking out loud 😂. Great video. I'll keep watching 👍
Thank you Lexi! Great Job
Great job. You go girl. Also, you have great patience. I have ran into a few of what you just went through and I didn’t have the patience like you did. I did a lot of yelling and cursing. Be strong
Old panels are such a trip. One of the last ones I worked in was so full all the knockouts had been used and the previous person had drilled 1/4in holes in the side and ran singles wires through. That same box also had cloth wrapped wire also for one circuit..
Excellent work and tutorial
Good video awesome work Lexi keep up the good content 😎
Look how much nicer and cleaner that looks. Wow, great job.🥃🥃
Excellent Job.
I've only ever needed to use 3/4" uni-bit, found it at the Home Depot. I could have sworn it was Milwaukee, however it doesn't have the brand label on it. That one was the most ease of use for me. It has a straight edge with five edges. Should be all you need to then use that knockout component to create the gap needed as long as it's a smooth surface. Knockout tend to bend with use on uneven surfaces and break. That might concern any client. So far you have everything and then some. Thanks for sharing.
That was great Thank you.🤠
Y’all f’ing ridiculous saying it took 8 hours. lol, it would take me a week then I would give up and call Lexi to finish.
100% true I do the same thing
Cuz you're not a man. 🤡
@@keirgamingmorons.
Honestly shouldn't take more than a few hours.
@@xsbiggy6349Companies make some big money on panel swaps. Takes a few hours and charge $500-1,000 for labor. Panel swaps is where the moneys at.
I’ve been using a 7/8” Milwaukee shock wave bits for my punch set. They’re cheap and fit in my impact 👍and hold up decently.
Few tips
On the unibit, greenlee is good, been using the same bit for 16 years, it's a matter of how you use it. Oil, low speed, high pressure and a pilot bit.
Adding a gutter can be the best thing to do in that situation.
Try to avoid panels with those kind of knockouts if all possible, you may be left with a hole not needed and critters can get inside and cause havoc.
If all possible pull those wires back before you take the panel off. Have seen it too many times where people have cut the wire and caused issues.
Take the time to make a panel schedule, it saves lives and equipment, plus it's code.
Take your time
love the work
excellent job 💯
Greenlee step drill bits works really well.
Nice job Lexi, I work in electrical service as well for a solar company. We change panels and meters.
100% agree that older wires had thicker insulation....found this out recently when redoing some wiring in my attic. I also confirmed this when I realized my old wire strippers (I've probably had for 30 years) weren't stripping new wire correctly as the cutter hole was expecting the older/thicker insulation.
I like how you said my dumbass forgot to do this lol. And here I thought I was hard on myself.. Great Job! You are awesome 😎
Anytime I get to a job and I see a 8/12+ roof I immediately start talking to myself! Haha! I’m glad I’m not the only one
Te a quedado muy bien. Saludos
Excelente trabalho! Parabéns 😊
Moving into the aptitude test! If I pass that then into an interview. Hoping to join the team! Great work btw!
Ive had my greenlee uni for 15 ish yrs ....granted i do hvac and dont use it as much as you are ...but i saw a spyder brand today that looked pretty sweet im going to pick and try out
Lexi, the best step bits in my opinion are the Milwaukee cobalt coated step bits. You have to order them on line but the last the longest. They are pricy up front but they do last a while. Panel steel is brutal on bits. But you should give them a shot. Also a drop over oil or pre drilling a small starter hole with a twist bit will preserve the longevity.
I enjoy your clips, you really know what you're doing. I have one concern, I used to be on the safety team where I worked. Don't you think anytime you are using power tools you should have a hairnet on? I almost thought you were going to catch your hair when you were using your drill.
I use the Klein carbide hole cutter bits instead of the step bits. They work great
hardworking, smart, charismatic, disciplined and gorgeus. you are not from this planet. greetings from thousands of km away.
I would recommend Klein QRST15 unabit on an impact. Milwaukee 49-56-9810 is the perfect size for the draw stud on the slugbuster. I always use a self tapper for a pilot to make the tip last longer, cutting oil also helps keep it cool!
For my personal StepBit I drill a pilot hole first and use some cutting oil. I use Milwaukee StepBits
Love it!!❤❤❤
Looks so much better
Pretty damn good job honestly.
As far as the unibits go I’ve had the best luck with the Dewalt ones. Last a very long time and about half the price of the Greenlee and Milwaukee brands and we use them Dailey. Hope this helps. Nice job BTW. 👍🏻
Nice clean job. A lot prettier than the other panel. Quality work.
You are good, every video you do your panels are so clean. from a shit hole to safe clean panel.
Greenlee step bits/unibits work great and they're half the price on ebay. Carbide hole cutters are good for stubborn knock outs, no pre-drilling needed. taping all the wires together before you shove them back in the panel makes them go in much easier.
Hey lexi👋, awesome work. Just so cool to watch you have that fun.
Is there like some kinda panel jack stand that can hold it in place while you adjust and screw the oanel into the wall? Im looking for such a tool to add to my collection.
So funny I sound exactly like that talking to myself while I’m working 😂😂
Nice job.
Literally a rock star! Any thought on selling T-shirts or other swag. I would definitely purchase one or two!
I have used the same Greenlee step bit for over 10 years.
Sutton tools is a good brand for drill bits we use in Australia we call them Christmas tree bits
Panels can get long! LOL! sometimes for no reason. When I review the panels that are being procured I have to make sure they are not super long! one time the vendor tried to give us a 6ft 400A panelboard! LOL1 there were so many spaces "provisions" on the bottom. They will line the breakers on one side sometimes instead of lining them up side to side to get the shortest height! Good job!
Incredible job on that panel ⚡️⚡️ have you tried the milwaukee unibits ?? Lex there pretty awesome
Can you take a stone to the cutting edge of the stepped bit? Honestly never sharpened one (only twist drills), but that is what I would try, first.
Good Job.
Use cutting oil with your unibits and other bits. When i did panels used it and it helped some.
Bosch titanium uni-bits have served me well
What a mess? You have more patience than me, I would ripe the whole panel off the wall. you go Lexi.
Question... I noticed some of the hot wires that went into the breakers on the lower, right side of the panel had some copper showing. Is that OK? I thought the insulation was supposed to go right up to where the wire goes into the breaker. LOVE the channel!!
Love and respect from India 🇮🇳… ❤️✌️
Wow there are a lot of poke hazards with that work. Noticed you didn’t have full coverage side shields… but pretty big glasses. Have you ever had any close calls with eye pokes?
Great Job!!!
I see that you are wearing safety glasses. Excellent.
You are the hero))
Well, at least they gave you service loops. Isn't there a tool for raising the box into place to make it easier than struggling with it? Like an old style car bumper jack of some kind. Nice job.
Where in australia we call them a step bit but what ya do is u spray a bit of WD40 on the surface ur goin to drill if its metal or get some oil and it will save ur unibit alot but also make goin through the metal faster
clever! wise man always told me never go in dry. lmao!
Found carbide hole cutters while double or triple the price of a unibit is way faster because you are only cutting g less then 8% of the KO and very little hot chips to burn you. I have a Klien 7/8" diameter that I have drilled over a thousand holes and still fairly sharp!..
Have u tried the Greenlee unibit? We used to get them all the time at work.. was a little expensive but lasted a lot longer than other bits
GreenLee step bit are awesome combined with cutting wax. It will last👍🏻
Amazingl
You are a pro 🙌 💪💪💪💪💪💪💪
Great work, wrestling all those wires into place 😅
Outstanding electrical workmanship. I didn’t see you put any fasteners in.
😅 That is a clean panel. 👌🏿
Just a question. Are you not required to use bond bushings on concentric knockouts? I know you didnt actually use the existing concentric knockouts but you were within them to some degree. And I like Lennox step bits. Great job btw
Nice panel swap, but I noticed your feeder phasing was black, blue, red.
Was this because of rotation ?
You are amazing
Maybe Klein would send you a case of step drill bits?! I have successfully used them but I clearly don't use them as often as you would...
You need a Greenlee GBS12, I sell electrical Parts in Florida. This is the best uni-bit, Expensive, but its because its the best. Klein's new Valo bits are nice aswell but they are expensive too.
Wow anda sangat berbakat😊
you probably already know this but, when drillings metals slow is key to making bits last.
In regards to the pre set knockouts why not cut the conduit back and put the necessary bends on the cut off piece to align with the pre existing cut outs?
Yep… she’s kareen!
I love seeing tidy wire management.
😊👍🏼
I like to use a tech screw to punch a hole then use the step but it saves your step bits lol
Omg get a nice 3/8 cobalt bit and a slug bunter kit. That expensive on unibits lol
I run a 7/8”-1 1/8” Klein bit. Was 50$ on amazon lasted me two years before it got chipped out a bit on the edge. Its dull but it still cuts a slow 1/2” knock out(7/8” hole) cut the 3/4” knock out faster.
Look, I don’t know anything about electrical work. And I don’t know how I got here. But that’s like the greatest face I’ve ever seen.
PLEASE tell me where you got that hex key set 🤯
Haven’t looked into it but maybe adding some oil to the uni bit as you drill may help extend the life of it
yep. Using cutting fluid when cutting metal will certainly keep the bit sharper longer.
Rockstar! Pretty sure you burped there toward the end ... major kudos for being human! ❤