Tamang Size ng Service Entrance Conductor
Vložit
- čas přidán 15. 02. 2020
- Sa video na ito ituturo ko sa inyo kung paano ma-determine ang tamang size ng service entrance conductor plus tips
Also visit my FB pages and group:
JB Online Shop
✓you can buy product such as Electrical devices mostly on industrial devices
/ jb-online-shop-8428213...
Jun Aux TV
✓all about Electrical installation and Electrical devices reviews and safety awareness on Electrical
/ jun-aux-tv-20510673918...
JB Handyman Services
✓If you’re looking for the right person to fix the problem you're facing in your home you can find it here, License Electrical Practitioner is available here, visit us
/ jb-handyman-services-4...
Electrician For Hire
✓group of Electrician looking for a job and giving and taking ideas in one another
/ 598549563632057
If you enjoy watching this video don't forget to subscribe, like and hit notification bell thank you!
Electrical wiring connection
Electrical wiring installation
Electrical devices tutorial
Power tools review
Hand tools review
New electrical devices
Thanks for Watching hope you enjoy. God bless
Thank You Brod Jun.. Sa mga inputs na natutunan ko.. Pag Retire ko sa Service.. Maga gamit ko ang Skill na pagiging Electrician.. Kahit sa Bahay ko lang.. God Bless..
Sir Jun... Pewde po demo mo... Installations of wire gamit ang 3-way at 4-way switches sa bawat ilaw ng stair sa 5 floor na building..
Eto na yung matagal ko nang inaabangan sayu sir MTS! Keep it up!
Hehe... sorry sir medyo nadelay video natin.....
maraming salamat po sa tutorial natoi, madmi po akong natutunan. keep uploading lng po thank you idol.(:
Thank you for sharing sir, marami po akong natutunan sa mga tutorial nyo.. godbless po 😊
Salamat din po sir....
sir jun thanks sa mga na turo mo marami na din akong na tutunan sayo keep safe always god bless
No probs po sir... maraming salamat din po sir...
Salamat po sa knowledge., keep the good job.
Salamat din po sir
salamat sir jun aux may bago nanaman akong natutunan sayo, pasout out naman po, taga tolosa leyte po ako, mabuhay po kayo sir,
Salamat sa mga tutorials sir at sa mga items na nabili ko sainyo hehehe. Godbless po
Maraming salamat din po sir...god bless po sir..may mga new items tayo sir sa jb online shop
Salamat sa mga upload mong kaalaman sir .
Good morning po may natutunan ako sa inyo salamat sa pag explain..nex tutorial pa shot out sir..
Thank you sir sa tutorial mo.
Ayos boss,maraming matototo sau,electrician din ako pero experience lng d nkpag aral,
Maraming salamat po sir
Ayos lang yan bastat mag check ka ng manual or meron fact reference pag gumawa ka. iwas sa tsamba tsamba na work para iwas din disgrasya. at laging e-apply ang safety basta live wire ang pinag uusapan.
Salamt sir sa mga idea na ini share mo. God bless you sir, marami akung natutunan sayo, bago pa ako sa larangan nang electrical . I salute you sir thank you so much.
Maraming salamat din po sir
Ito po talaga yung inaabangan ko nung nakaraang house wiring Tutorial mo Sir
Salamat po.
Oo nga sir nabusy kasi kaya delay na ung mha video natin sir.... maraming salamat po sir
Sige po, susuportahan ko mga videos na gagawin mo po
Nice master slamat po Ng marami😊
Thank you sir sa add. Info. Sir request po sana sizing ng dapat na contactor😅
Brod xenxa na sa comment ko pero alam ko marunong ka . Alam kong marAmi Kapang matutulungan.baguhin mo lang ung mga stake mo ,wag masyadong technical kasekame na gusting matuto ng walang pambayad sA school sainyo lang kami umaasa,wanna wag namang masyadong technical.un lang brod more power sa ch. Mo
papano po malalaman sir if there are more panel board for example sa isang commercial bldg. with all its components form Service entrance size to Main Breakers to a number of panel boards. hope to see a full video explanation and tutorials for a simple type of apartment styles or commercials type po. So Helpful po ng mga videos nyo sir... Salamat po ng madame...
Maraming salamat Jun
Ayus to .. more power sir jun
Salamat po sir...
tnx sir sa video marami natutunan
Maraming salamat sir Jun sa malinaw mong paliwanag .God bless po.
Maganda yang tutorial mo boss.madami akong natutunan. tanong ko nga kung puede yung walang MTS pero may nema 3r tas deretso sa panel board?.
Salamat sa tutorial sir😊
Maraming salamat din po sir...
Solid subscriber here
sir discuss mo din yung color coding ng wires para marami ang makaalam mula sa main entrance grunding, power outlet lighting, aircon range etc thanks
Thank u sir.
Sir good morning i realy appreciate yuot tutorial and i want more knowedge about on how to install the right number of wire or sizes ,for service entrance,outlet, lights and switches,shower heater and water pump thats my concern,and i hope
you can help me thank you so much and good day.
New subcriber sir.. salamt napaka informative mupoh..👍👍👍 meron napo ba kayo vedio about sa malalaking wire ang main breaker gaya ng 200 amps, anu po sa meter termanation?saka size of wire sa service entrance?? Salamat po sir info..
GOOD JOB SIR
Thank you idol may natutunan na nman ako Mula sa good tutorial salamat and more power Emil from Caloocan city God bless!
Tsaka "feeder"(pvc conduit) na po ang tawag pag load side na ng 30 amp service disconnect..... Ang "service entrance conductor" (metallic conduit) ay hanggang sa "line side" lamang ng 30 amp service disconnect.... Malalaman mo kung service entrance conductor kapag walang paraan mo mapapatay ang power kundi tawagin ang electric utility
thank you for additional info sir..stay safe po
Salamat boss
Thank u boss. Very informative. No. 2 pala talaga pag 100amps. San kaya boss pwede makabili nung wire na 30mm2 dito sa bulacan?
Nice tutorial sir 😊
Thanks and welcome
@@junauxtv pwd po ba NEMA 3 100 TO 60 MAIN??
salamat Boss
Ok ah
Sir maraming salamat sa tuturial nyo mdami na din po ako natutunan tanong ko LNG po among laki LNG po ng wire para sa bilog na meterbase
magbase po tayo sir sa rated amps ng metro sir..
Ok tnx
Nice boss
Sir Jun pakigawa nman ng video paano mag-install ng wire gutter for multiple meter.
Soon po yan sir...wala pa lang tayong gamit
Ayos yung nasa background na raketa dong 😁
Hindi ko na nga ngagamit yan dong...hehehe
Pm kita kapag nagka-sched uli dong
Sir may napanood ako na video mo,kung 100 square meter ang bahay, ilang amperes?TV,component, ref, rice cooker, plantsa, electric fan, washing machine yan pi ang mga gamit, salamat po sa nasagot,more power and God bless.
pwd na jan sir 40a
Sir Jun, tanong lang po... Kailangan ko pa ba maglagay ng Nema 3R breaker aside from main panel board? Salamat po & Godbless!
Proud san lukas tech'n.
Sir salamat at marami akong natutunan sayo.. Ask kulang kong magkano ang ang price ng contactor.?
depende sir kung ilang amps need mo sir..
Boss nasa PEC ba lahat ung cnasabi mo? Bat dmo nabanggit kng ano ang standard height ng metro at ung size ng pedestal entrance? At ung mga clearance ng breaker at sub breaker mo dapat me clearance yan wala sa code yta ung nlagay mong L-T box d pede ung gagayahin mo ung gawa ng iba, pano kng mali at wla sa code d mali rin mali yta ung mga paliwanag mo.
Salamat po sa tutorial Sir. :)
At sumakto po itong vid na to sa itatanung ko. Ask ko lang po? Kung may 20 piraso na tig 5hp na aircon(commercial)? Ilang amps po ang required nun? :)
Main po ba sir or each?
@@junauxtv main po Sir.
Ano ba ang linya mo Single phase o 3 phase.
Verry well said idol, ask ko lang sana idol kung tama ba ang gagawin ko bali gumamit ako ng single CB 20 A para sa switches at outlet dahil tv, washing machine, electric fun at tatlong ilaw lang ang gamit ko, ngayon ang problema idol is dahil makiki connect lang kami sa kapit bahay at may sarili naman pannel board ang kaso malayo na ang distansya kaya diko pweding idugtong doon ang aking breaker so pwedi ko bang lagyan nalang ng pinaka extension wire ang breaker which is #12 at isak isak sa outlet nalang? Sensya na idol masyadong mahaba ang kwento ko!
Malaking tulong ka sir sa mga naguumpisa mag contrata ng electrical services...salamat!
Sana ipinaliwanag mo din kung bakit hindi dapat underrated or overrated ang service entrance conductor.
sir idol sana po magturo ka din ng FACP with interfacing sa control ng jockey pump or fire pump. .thank you po
soon sir sana magawan natin yan..
@@junauxtv update
@@JZMusicChannel wala pa po sir...
Sir may sina unang PLANKA kami gusto ko sana e DIY by my own into Panel Board then bawat breaker naka attach ang bawat output ay may submeter kc nagppa ROOM for RENT kami salamat sa pag tugon
👍👍👍
Sir, ang nagproproptect sa feeder between 30 amps service disconnect at main breaker ay ang 30 amp service disconnect. Hindi po ang 60 amps breaker sa panel... Kasi yung 14 mm sq. wire is line side po ng panel.
what if sir walang service disconecct ano ang magpoprotect ng service entrance conductor mo..?
@@junauxtv sir, bawal po ang walang service disconnect base sa PEC section 2.30.1.2. .. Baka ang tanong po na dapat ay ano ang magproprotect sa line side ng service disconnect? Meralco po ang may tungkulin kung gusto nila protectahan ang service entrance conductor. Salamat po
sir.pa request nman yun.pagset up ng 24ways na mcb 2p0le breaker
Sa outlet kung 20a breaker dapat outlet mo 20a din. Kadalasan na binebeta rated lang for 10a or 15a.
Sir request ko lang po kung paano mag install ng mga meter base sa isang commercial building.... kailangan ba ito ng malaki laking space para dito? at saka pwede bang ilagay yung mga meter base kasama ng mga panel board ng building?..... salamat sir
cguro ang dapat gawin sa atin gumamit n lng na breaker n afci at gfci . kaso medyo mahal nga lng
Dapat naman talaga meron kaso hindi na nagagawa
Thanks.my question is why you have 2 main breaker?
You mean MTS sir?
pa shout out po sir watching fom dammam ksa
Jun ask lang ako ano ba yung nilagay mo na separate box sa taas ng nema 3r at katabi ng mcb breaker din ba yun?
Good evening sir Jud may tanong lang po ako may ilili pat kasi akong service entrance tapos ang wire ng service provider (#10 5.5mm²) tapos sa bahay na wire Service etrance wire 8.0 balak kasi ng may ari na magpagawa ng bagong bahay katapat lang ng kanilang lumang bahay, Hindi nalalayo ang mga load ng bagong bahay at ang luma PWeDE ko bang lakihan ko ang wire ng service entrance from (8.0mm²) to ( #6 14mm² or #4 22mm² wire) kahit Di alam ng service provider or meralco??? I advance ko nalang para Hindi na magpalitpalit ng pa wire ang may ari kung sa Kali magawa na ang bahay baka kasi in the future may idagdag pa I advance ko lsng sabi mo nga sir sa video mo,, Sana masagot nyo ho sir salamat..
Sa meralco
De 10 yung standard wire
Nila para sa commercial
Kaya 30 amp na breaker
Gagamitin
Gud pm sir para po makuha ang tamang size of wire sa service entrance dapat po muna makuha ang lighting plan at computin po ito.
Kung mag uupgrade ka ba ng size sa feeder at breaker, pati yung galing poste na wire ay kailangang palitan din?
Helo Sir new subscriber ako sa chanel mo.. May itatanong Lang po ako.. Kc yung pinang wiring ko sa ilaw ay 3.5mm no. 12 ok Lang ba ito at 15 amper ang ang c.b niya bali 11 na ilaw siya. Salamat sa sasagot..
Sir tanong ko lang para sa 6 branches na panelboard kung 60 amperes ang main CB ng panelboard then my 3 branches na may tig 20 ampere para sa aircon, water motor at convenient outlet at isang 16 ampere para sa ilaw at may isang spair na CB kaya padn ba ng main na 60 ampere kung sakali in the future maging 20 amperes din ang spair na cb so Bali 4 branches na may 20 amperes at isang 16 amperes Sana masagot mo sir ang tanong ko balak ko kasi palitan plug in type un luma namin panelboard na fuse type salamat sir and Godbless
Sir request lng po kung panu mag install ng 3 phase breaker.
Soon po sir...
Sir salamat madami na din ako natutunan sa inyogusto ko LNG sana malaman Kong anong laki LNG ng wire para sa bilog na meter base tnx po
Pwede bang mag exceed ang ampere ng mga branches circuit breaker sa main breaker na 60amp? Ano po ang disadvantage nun sir and what is the solution. Sana sagutin mo.
Opo sir....hindi mo mamaximize ang ampacity ng isang cb
Master pwede po ba na 40amp ung NSA NEMA at pagdating SA branches ay 30amp nlng.kasi malau SA bahay ang poste Ng meralco.
Informative. Kaso hirap sundan ng sinasabi mo. Mas maganda kung meron ka ng script o outline na guide mo para hindi pautal utal sa pagsasalita at patalon talon ng sinasabi.
agreed
Sir tanong ko lng p0 mgppkabit aq ng split type aircon, ok lng ba na ggmit ng 3.5mm stranded or #12 na wire sa 20ampers na breaker at ikabit ito sa main source? Hnd po cya idaan sa main breaker kc 30amp ung breaker ko sa loob ng bhy
Sir meron po b kaung mairekomendang tao para mag install ng wire mula sa poste ng meralco patungo sa loob ng bahay?
sir may tanong lang po, kung ok lang ba ang 15amps na breaker para sa 0.5 na aircon. . at tsaka ok lang ba din na 15amps ang service entrance. .
Boss yung wire size ba either copper or aluminum same lang consideration sa sizing ng wire or 1 size higher yung aluminum? Thanks
sir, sa phelpes dodge and royu wire, ano po advantage and disadvantage nila
Gud am, ..boss, bakit kailangan pa ng nema 3r na may pareho din amperage ng cb sa mismong panel box, diba pwede na deretso na lng frm kwhmtr to panel box
Brother jun tanong ko lang dito po sa amin sa zamboanga city ung hot at neutral lang pwede po ba gawin ito ng line to line at may neutral paano po siya gawin ?
Naisip ko sir lalagyan ng capacitor pero hindi na din applicable kasi 440v na po un...hindi rin po advisable...para sakin sir its a no
Good Afternoon Sir, Sir Boss saan ba kinukuha ang size ng wires sa conductor? o sa insulator?
tamsak at dikit na lodi...pasukli na lang..
Idol may tanong Lang ako tungkol naman sa inverter na welding machine puwede bang mag plug nalang ako sa 220 outlet na may 30 Amp or direct mismo ba ang circuit panel ako kukuha ng power at makakasira ba ng appliances ang welding machine? salamat God Bless..
Direct ka po sir sa circuit breaker... hanggang 10 amps lang kasi madalas ang outlet sir...tnx po
Idol ano main breaker ng may load ka aircon washing machine dryer at dicoryente kalan at heater sa shower tig iisa ba sila ng breaker at ano size ng wire
tapos na po kc ang bahay sir
Boss Jun, sa province ko ay L to N and power supply. So, anung common size ng wire ang nasa power provider (yung wire papasok sa service entrance cap or service drop ba yun?)? Kung sa 100 amps na breaker ay gauge #2 wire ang standard, may chance ba na mas maliit yung wire ng power provider? Currently is 60 amps/10 branches lang house ko at like ko mag upgrade. Thanks again.
bili ka mam juliet ng electrical book by max fajardo.....
Yes mam...nangyayare yan....ang wire na gamit mo is no.2 din ang galing ng Power provider is no.6 lang...lalo na kung upgrade hindi na nila pinapalitan...
Ask ko lng qng ok lng ba na dumikit sa grills ng terrace ung conduit pipe pro mataas nmn ang dulo na kakabitan ng head cap?
Pwede bang number 6 ang wire na ilagay sa circuit breaker sa baba nang metro kahit na 40 ampere.
Good day, sir maari ba mag lagay ng dalawang panel board, tag 60amp ang main separate ko po sana ung first floor and second floor maraming salamat sir God bless 😊😇
Sir may sina unang PLANKA kami gusto ko sana e DIY by my own into Panel Board then bawat breaker naka attach ang bawat output ay may submeter kc nagppa ROOM for RENT kami salamat sa pag tugon
Sir jun pwd ba ang single circuit breaker sa 10 outlet at 8 na ilaw.ty
Sa nakikita ko sir kaya mdami sunog s atin dyan s pinas eh madami pa tayu di alam about s electrical.general contractor po ako to LA Ca mdami na kami nagawa dto s construction.tip ko lang po s electrical para iwas sunog s atin una service entrance dapat eh number 8 na wire dropline ang twag dto tas pangalawa 200amps ang kilangan mo install kc 220volts s atin 16 n circuit breaker kilangan mo na tig 20amps para dka mag trip ang breaker tas separate mo yung breaker s ilaw appliances at at outlet kc dyan kaya madalas ang sunog sma sma yung mga ilaw outlet at para s appliances tas number 12 n wiring ang gamitin para s outlet at appliances at ilaw number 14.at isa pa kulang s atin ay ang green wire na ground kc ang panel mo dpat nka ground s lupa at s water supply mo para iwas sira yung mga appliances mo pag nag trip sya at ang kulang s s atin s kaalaman s electrical yung wiring nyu dpat by color hard color wire is hot wire and white wire is neutral and green is neural para d malito at makuryente suggestion lang po sensya na mahaba try mo lang sir kung ok thank you
Green is ground wire i mean
Dito kasi satin sir walang nag inspection after mainstall kaya daming nakakalusot na mal practice na electrical installation at wala ding ngsusupervise na mga license electrical practitioner.
Kase dto sir bago ka magkabit ng electrical dpat licensed electricia ka or gen contractor ka.una dto punta ka ng building and safety tas mag fill up ka ng form kung ano ilan ang ggwin mo then kong me upgrade k ng panel or mglagay k ng bago ddaan pa yun s inspector then pag na ok magbbyad k ng permit then kilangan mo kontakin yung DWP dept of water and power yun dto sila mag decide kung saan k mglagay ng service service entrance mo then pag na aprob pde k mag start then aftr twag k ng rough inspection then inspection ng city inspector then pagtapos kna twag k ng final inspection kc dto d minamadali ang trabaho by process kya bhira ang aksidente suggestion ko lang pero saludo ako sayu sir kc mhrap yang gngawa mo godbless u
Sir Jun dito sa amin probensya,halos lahat dito walang nema 3r,from the post dun na yung metro, service drop wire na agad papunta na yun sa service intrance coductor deretso na sa main breaker..ok Lang po ba?
(8mm2 wire Yung service intrance coductor)
(60amp Yung main breaker..)
idol active ka paba sa nagtatanong kasi gusto ko malaman kong anong # ng service drop sa THHN #6 wire mula sa poste patungo sa meter pole
Gudampo sir tanong lng po ng kabit ako ng 20amp s outlet at 15 amp s ilaw s breaker ano po pwede Amp s main ng 20amp at 15 amp salamat sir
Sir jun gd am, sir ask lang, isa 40 ampere main sa 2nd flor isa 40amper sa irst floor ano dapat ang sa main intrance ilagay sa nema 3 r, sir?
Tanong kolang sir pangmalakihang bahay ba yan masyadong mataas ang main circuit braker
Ano po ba and magandang gamitin na wire para sa bahay. Stranded wire po ba or yung solid wire. Pwedi rin pu bang gamitin ang romex wire sa pilipinas? Im in the process po kasi na magpagawa nang bahay sa pampanga. Thank u po
Gd pm,.sir kahit ba medyo maliit ang bahay,let say 2 rooms lang,.OK LNG ba kahit 60A ang main breaker?tulad ng NASA video mo..
Sir salamat advice mo. Tanong kolang ok bayon 100 amp. Ang breaker tapos ang wire #14 tapos 3 ang aircon di ba dilikado yon?
Undersize wire sir...
Sir mgkano pambuttas mo sa yero ng nema 3r panelboard o wire gutter.mgkano bawat isa.#1/2 #3/4 #1"
Sir kung sa panel ko may nkalagay na (1)15amp at (3)20amp ok lng po ba sa main breaker ko ang 40amp at #10 THHN?, #10 str po kc nabili ko na service entrance conductor
Sir halimbawa nga po 100A yung main ckt breaker tas yung alloawable ampacity na wire is 2awg. Papuntang service entrance.tutugma po ba yun sa wire ng secondary line ng service provider papunta nman sa service entrance? Naguguluhan po ako ei., sana po masagot. Tnx po in advance
Sir ask ko kapag 30amp iyong breaker namin sa main at saka dun sa bahay, 8.0mm din po ba iyong wire na gagamitin na pang entrance?