Cummins Genset cantroller pcc 3300/pcc 3.3 Cummins cantroller 3300 की पूरी जानकारी

Sdílet
Vložit
  • čas přidán 19. 09. 2020
  • Cummins Genset cantroller कि पुरि जानकारी

Komentáře • 101

  • @vikrammalviya7917
    @vikrammalviya7917 Před rokem +1

    Thnx sir apke video se kafi help mil jati h.. 🙏🏻

  • @sagarboliya2249
    @sagarboliya2249 Před 2 lety

    Bahut accha vidio
    Paheli bar Aesa janretor par vidio dekha👍

  • @hathilayogesh7640
    @hathilayogesh7640 Před 3 lety

    thank you soooo much sir..
    1st time itna acha video mila hai.
    keep it up 👍👍

  • @user-dz1on7bl8k
    @user-dz1on7bl8k Před 5 měsíci

    Good work 🎉

  • @sandeepyadav-hy9ef
    @sandeepyadav-hy9ef Před 3 lety

    Nice video sir bahut jankari mili

  • @alwaystruereality3753
    @alwaystruereality3753 Před 3 lety

    Very good information Sir.

  • @moirangthempriyokumar8167

    Thanks🙏 sir necily prepomes and alternator

  • @mohammedzakirmustafa4079

    Very nice thank you sir

  • @rkprasadbhookya1878
    @rkprasadbhookya1878 Před 2 lety

    superb.
    .sir

  • @soumyaranjanpradhan8300

    Nice vdo thanks

  • @merawatan3072
    @merawatan3072 Před 3 lety

    Hello SIR deep sea 8610 coumins GENSET PAR Kaise lgate hain

  • @sabirhussain9420
    @sabirhussain9420 Před 2 lety

    Sir pcc3.3 mein kiya sabhi sensor by pass ket sakte hain.
    Please all details given here

  • @TanveerKhan-bk7sq
    @TanveerKhan-bk7sq Před 2 lety

    Can you share video for DSE7310

  • @devjaiswal0839
    @devjaiswal0839 Před 3 lety

    Sir , 500 kva ka Genset controller ka display off nahi ho raha hai, please site pe settings bataiye, sir aap ke video bahot helpful bhai.🙏🙏🙏

  • @roufwani3743
    @roufwani3743 Před 3 lety

    How calibration hmi 320 in pcc 3300

  • @vipinchoudhary2787
    @vipinchoudhary2787 Před rokem

    Sir, governer card ko supply kaise ja Rahi, please explain karna.

  • @merawatan3072
    @merawatan3072 Před 3 lety

    KINDLY circuit diagram bna kar upload kar dain

  • @rameshraj8482
    @rameshraj8482 Před 2 lety

    Thank you so much sir i under stood can u please tell me fuel water sens warning 428 ECM004!hi what to do this warning how reset normal condition
    In our same 780kva dg fuel soilened coil is not working. We replaced now working normal

    • @shivammahajan1882
      @shivammahajan1882 Před 2 lety

      Water sensor warning is for coolant and there are 2 types of warning one is coolant level low and 2nd is coolant sensor hi....if it shows coolant sensor hi try to change coolant sensor harness...if still warning exists try to open sensor with 33 no. Spanner only to some extent when coolant starts leaking then tight it again then press reset button and if it still shows that then your coolant sensor is not working change the sensor.
      Shivam Mahajan
      Testing enginner incharge
      Sudhir power ltd

  • @pundliklavhale6078
    @pundliklavhale6078 Před rokem

    Engine Crank dose not starting , replaced MPU... what' smore action

  • @satenderparmar5423
    @satenderparmar5423 Před 2 lety

    Sir voltage Puri hi but self nai uthaa rha.1500 kva dght

  • @premKumar-se7ht
    @premKumar-se7ht Před 3 lety

    Sir remote system use kaise kiya jata hai

  • @devrana..
    @devrana.. Před 3 lety

    Electrical wiring and use and fuel cycle full

  • @emranakash582
    @emranakash582 Před rokem

    Battery charger konsa hain?

  • @brijmohan9707
    @brijmohan9707 Před rokem

    Sir 2250 kva ke bare me bistar se batar please

  • @purusottamjena1474
    @purusottamjena1474 Před 2 lety

    Sir how to solve 2335 excitation fault in 1010kva cummins DG set.

  • @AaricBeats9
    @AaricBeats9 Před 3 lety +1

    No display and no supply on pcc 3.3 controler. Checked starter fuse. Negative voltage -2 volt found on. J20_21 connector. How to solve.

  • @ramchandrawadu684
    @ramchandrawadu684 Před rokem

    Establishing comm kay hai sir

  • @mannatgill3115
    @mannatgill3115 Před 3 lety

    Sir aap Aux 101 ka posetive Wire ka number bta do TB koun sa hai.dono dg synchronize hai .

  • @Santoshsharma-xt7ki
    @Santoshsharma-xt7ki Před 2 lety

    Sir demo foult kaise thik kare

  • @rameshsirisha2409
    @rameshsirisha2409 Před 2 lety

    🙏🙏

  • @shivpratap2241
    @shivpratap2241 Před 2 lety

    DG HMI me running hours show nahi kr rha hai

  • @brijmohan9707
    @brijmohan9707 Před 2 lety

    Aap 2250 kva DG set ke saath batae please

  • @Subscribekardo1990
    @Subscribekardo1990 Před rokem

    My display shown demo mood
    What is the demo mood

  • @priyabratmohapatra5426

    How to solve fault code 7697 in Cummins engine.

  • @syedsabri1345
    @syedsabri1345 Před 2 lety

    Hi,
    How to check charging alternator .
    When battery not charging.
    I replace the carbon brush but not charging,
    Winding all are ok.
    What is the fault .
    Please reply sir.

    • @Trending-313
      @Trending-313 Před 2 lety

      If charging alternater is in good condition but battery not charging there some leakage in wiring checke wiring

  • @sabirhussain9420
    @sabirhussain9420 Před 2 lety

    Manish Bhai please all details falt and remove DG 1010 kva

  • @manishkr.sharma8366
    @manishkr.sharma8366 Před 2 lety +1

    Demo mode fault ka batao sir

  • @narendrachauhan5193
    @narendrachauhan5193 Před 3 lety

    Dear sir please help
    Display battan ok and aro battal not warking

    • @technicalmanish9032
      @technicalmanish9032  Před 3 lety

      Dear,
      In this cantroller some issue after some time runing button not working.
      Please confirm which button are not working.

  • @Ashokkumar-io8ts
    @Ashokkumar-io8ts Před 3 lety +1

    how to fix the 236 ecm problem in pcc3300

    • @technicalmanish9032
      @technicalmanish9032  Před 3 lety

      Engine speed position sensor not detected
      1 ) may be position sensor faculty.
      2 ) faulty engine harness.
      Please check 5 voltage dc in position sensor pin.
      Please check previous our video sender voltage

  • @kalimmohammad5525
    @kalimmohammad5525 Před 3 lety +1

    How to synchronize this pcc please make a video

  • @aviroy7725
    @aviroy7725 Před 3 lety +1

    Aur video chaiye plzzz...

  • @shashibhushan8261
    @shashibhushan8261 Před rokem

    Aadal me karna hai

  • @ManojKumar-tf6uy
    @ManojKumar-tf6uy Před 3 lety

    Remote Start vha lait jal raha es lai D G nahi start nahi horha hai Romote laet kaise khatam hoga

  • @sandeepyadav-hy9ef
    @sandeepyadav-hy9ef Před 3 lety

    Sir 1500 kva ke Dg me auto wali button blink ker rahi hai mhi disple per not in auto likh ker aa raha hai kya Kare.

  • @sandeepdurhan1302
    @sandeepdurhan1302 Před rokem

    Agar display on hi na ho to kya reason h

  • @HariHaran-rv5bl
    @HariHaran-rv5bl Před 3 lety

    Sir is possible means future videos please explain in english

  • @mohhamadmanjur8949
    @mohhamadmanjur8949 Před 3 lety

    If HMI 320 in Demo mode, what we will do?

  • @MegaDayanand
    @MegaDayanand Před 3 lety

    HMI 320 (1010 kva ) showing ESTABLISHING COMMUNICATION FIRMWARE VERSION with some number's... What to do???
    Cummins guy saying calibration is no use because the light in base board is not blinking ..so... I need to change baseboard of 3300 which is 1.3 lakh ...

    • @Trending-313
      @Trending-313 Před 7 měsíci

      he is telling true ......I am cummins engineer baseboard is failed ...

  • @subhashisnayak3900
    @subhashisnayak3900 Před 3 lety

    Sir how to solve error code 2898

  • @rajeshindia7812
    @rajeshindia7812 Před 3 lety

    Manish Ji aap kaha pr based ho, apna mobile no. denge to kuchh kam ki bat karni hai, 750 KVA ieset mai 3100 PCC ke bare mai.

  • @timothywilliams7748
    @timothywilliams7748 Před 3 lety +1

    English??

  • @mannatgill3115
    @mannatgill3115 Před 3 lety

    750 kva cummins ka dg hai

  • @shivammahajan1882
    @shivammahajan1882 Před 2 lety

    I am in sudhir power limited as testing engineer incharge....you are wrong bro...this pcc only comes on demand for greater then 750 kva.....this pcc belongs to only 250 to 380 kva gensets

    • @technicalmanish9032
      @technicalmanish9032  Před 2 lety

      Thanks for watching my videos.
      This cantroller for all DG

    • @ujjawalrai3938
      @ujjawalrai3938 Před 2 lety

      Shivam ji. What we have to check to clear the pcc net device failed 2895 error?

  • @devrana..
    @devrana.. Před 3 lety

    What's app number please and DG ke tank me bhi koi pump hota hai kya please explain

  • @syedshahnawaz3057
    @syedshahnawaz3057 Před 3 lety

    What is the default password of this controller?

  • @ahmedhamza3582
    @ahmedhamza3582 Před 3 lety +1

    I need the drawings for controllers

  • @RakeshPatel-jc8wv
    @RakeshPatel-jc8wv Před 11 měsíci

    Windig fhild me hiter kaha laga hota o kaisa kam karta windig ko nami se bachne ke liye

    • @technicalmanish9032
      @technicalmanish9032  Před 11 měsíci

      Hitting elements are fitted back side of alternator in air suction point. Also send me alternator and engine details

    • @RakeshPatel-jc8wv
      @RakeshPatel-jc8wv Před 11 měsíci

      @@technicalmanish9032 1010 kva DG Cummins

  • @roufwani3743
    @roufwani3743 Před 3 lety

    How calibration hmi 320 in pcc 3300

  • @ajaygoyal564
    @ajaygoyal564 Před rokem

    Manishje total power com chori ho gya h ,please provide

    • @technicalmanish9032
      @technicalmanish9032  Před rokem

      Power com chahiye ya another cantroller what's aap no+919839787404 . Please send engine model