How To Wire A Split Outlet With Bottom Controlled By Switch & Top always Powered On! DIY Tutorial
Vložit
- čas přidán 27. 02. 2022
- ITEMS I USED:
- Voltage Detector - amzn.to/3tkkuHg
- VOLTCLAW - amzn.to/3K33v3b
- Wire Strippers - amzn.to/3Hu5Cew
- Insulated Screwdriver (2-in-1) - amzn.to/3HtEVXz
- WAGO Wire Connectors (36 Pieces) - amzn.to/35ARqmI
- WAGO Wire Connectors ((75 Pieces) - amzn.to/3Ize4us
- Long Nose Pliers - amzn.to/3Ix6u3o
Commercial Grade TAMPER RESISTANT Outlet / Receptacle:
- Leviton 15AMP (125V) Duplex Outlet Tamper Resistant- amzn.to/3LlHCNW
- Leviton 20AMP (125V) Duplex Outlet Tamper Resistant - amzn.to/3oBypaE
- Leviton DECORA 15AMP (125V) Duplex Outlet Tamper Resistant - amzn.to/3JgbSYD
- Leviton DECORA 20AMP (125V) Duplex Outlet Tamper Resistant- amzn.to/3oyTkew
Residential Grade TAMPER RESISTANT Outlet / Receptacle:
- Leviton 15AMP (125V) Duplex Outlet Tamper Resistant - amzn.to/3JibicU
- Leviton DECORA 15AMP (125V) Duplex Outlet Tamper Resistant - amzn.to/34to1e8
- Leviton DECORA 20AMP (125V) Duplex Outlet Tamper Resistant - amzn.to/34Lc03F
NM ELECTRICAL CABLES I USED:
- ROMEX 14/2 (50’) - amzn.to/3rHU5Ue
- ROMEX 14/2 (100’) - amzn.to/3HJgsys
- ROMEX 14/2 (250’) - amzn.to/3JiuGXm
- ROMEX 14/3 (50’) - amzn.to/3sCxW9a
- ROMEX 14/3 (100’) - amzn.to/3oHMBij
- ROMEX 14/3 (250’) - amzn.to/3uQTMbE
- ROMEX 12/2 (50’) - amzn.to/3oGQkwE
- ROMEX 12/2 100’) - amzn.to/3BhSZSh
- ROMEX 12/2 (250’) - amzn.to/35WJzA6
- ROMEX 12/3 (50’) - amzn.to/3sC2Q1o
- ROMEX 12/3 (100’) - amzn.to/34VOYao
- ROMEX 12/3 (250’) - amzn.to/34AyNiL
SHOP MY ONLINE AMAZON STORE AND CHECK OUT ALL THE TOOLS I USE!
www.amazon.com/shop/genevo9
On this episode I'm going to show you How To Wire A Split Outlet With Bottom Controlled By Switch & Top always Powered On! DIY Tutorial. This is a simple step by step tuturial circuit wiring where you can wire a split outlet receptacle!
Please Subscribe To Our Channel! / fixthishouse
FOR BUSINESS INQUIRES SEND TO:
FIX THIS HOUSE
P.O. BOX 2511
BREMERTON, WA 98310
UNITED STATES
FOR BUSINESS INQUIRES EMAIL ME AT:
fixthishouse1@yahoo.com
DISCLAIMER:
This video is meant for informational, educational, and entertainment purposes only! To better your knowledge on the concepts of electricity, electrical circuitry, entertainment component circuitry and all other wiring methods. Electrical codes in my area may be different from yours so always make sure you follow and stay current with your local code. With different codes around the world constantly changing standards, regulations and rules, it is the sole responsibility of the viewer to educate themselves on their local requirements before undertaking any sort of project. That being said Fix This House cannot claim liability with all applicable laws, rules, codes and regulation for a project. DO NOT ATTEMPT ANY WIRING OF ANY KIND if you lack the knowledge and understanding required. Otherwise, personal injury and/or death as well as property damage or loss could occur. Your safety is your own responsibility, including proper use of equipment and safety gear, and determining whether you have adequate skill and experience. If you are a younger person or are inexperienced with electrical devices, ask for help from a parent, teacher or a licensed professional.
WARNING- Electricity is dangerous and can cause personal injury or DEATH as well as other property loss or damage if not used or constructed properly. If you have any doubts whatsoever about performing do-it-yourself electrical work, PLEASE do the smart thing and hire a qualified and licensed electrician to perform the work for you.NEVER WORK WITH LIVE VOLTAGE. Always disconnect the power source before working with electrical circuits.When performing electrical work, ALWAYS READ AND FOLLOW THE MANUFACTURERS INSTRUCTIONS AND SAFETY GUIDELINES. Always follow your local electrical code and requirements which are specific to local areas.By utilizing this video and the information given, YOU are expressly holding "FIX THIS HOUSE" HARMLESS FOR ANY PROPERTY DAMAGE, PERSONAL INJURY AND/OR DEATH, OR ANY OTHER LOSS OR DAMAGE THAT MAY RESULT FROM YOUR ACTIONS. Viewers must be aware by doing projects on their homes they are doing it at their own risk and Fix This House cannot be held liable if they cause any damage to their homes. Fix This House and all parties associated with it ARE NOT responsible for the use and results of this information by any party, especially those lacking sufficient skill or knowledge to perform these steps safely and ANY HAZARD CREATED IS THE SOLE RESPONSIBILITY OF THE USER.
DISCLAIMER: This video contains affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.
#outlet #switch #receptacle - Jak na to + styl
Good job as usual
Thank you so much of the great video 👍
Thank you so much! 🙏🏽😊
I was so confused on how the bottom outlet worked when the neutral from the 14-3 wasn't connected. Then it clicked that they you didn't break the neutral on the outlet. Very informative. Thank you.
THANK YOU, THANK YOU, THANK YOU!!! I was confused as to why my new plug powering the dishwasher and the garbage disposal connected to on/off switch did not cut off when plugged in. Made my DIY day. 😃
This was not what I was looking for but it was so informative, so I watched all the way to the end. 👍🏾
Thank you so much for the love and support! 🙏🏽😊
2020 nec 404.2(C). No neutral is necessary in the switchbox with the switch that controls a recepticle. Your video could have been done by re-identify the white wire as hot and connecting it to the switch like the red wire was.
For the home owners, the old nec phrase was down on white, up on black, sending power (hot) on the white wire to the switch and returning power from the switch to the recepticle on black.
Good video though.
Thanks, I was looking for this and questioning myself.
Also, why even connect the neutral from the 14/3 (assuming you wanted to use red) , it seems like an unnecessary risk. I mean, I can see why someone might want to use a red wire but the neutral threw me off.
Thank you very much for doing this video. I'm not a professional electrician, but have been replacing bad light switches in a unit on the property. Some of the wall outlets lose power when turning off the actual light. The power line coming into that room is the end of the line for that side of the property and controls the whole room. Then having to piggyback multiple outlets and a closet light switch. Lol This video was very informative and very detailed. Thanks again, now I can get this done without wasting much more time or pulling out my hair! 😂😂
Great video. Saved me from searching for some specialty plug. Easy peasy. Thank you.
Best videos! I’ve been a wago user since I first saw you using them in your videos also a claw user. It is a great tool!
Beautiful explanation! It’s very clear and easy to understand! Thank you!
this video clearly addresses my needs. thanks for clear explanation. like your mock setup a lot. Thanks.
Wonderfully useful video. My house is mid 70's build. I found a split receptacle wire with two wire 14 gauge where the white wire must have been hot. It was disconected at the originating box. Totally confusing until I saw this video and the comments.
👍Thanks kindly 🤗
So clear & very helpful 🎉
Thanks for making this Video, it helped me to understand concept clearly.
Awesome video....great explanations. 👍 Thank you
Thank you! This is super helpful
Very helpful. Thanks!
You are the best thank you for sharing your knowledge.
Thank you 🙏🏽 for your support!
Outstanding explanation. Thank you
Good job brother 👏 👍
Thanks, super helpful!
Another great and informative video, thank you again!!!
Thank you Ricky!🙏🏽😊
You are incredible! Thank you.
Thank you so much! 🙏🏽😊
Thanks for making it a simple install
It was my pleasure Danny! Thank you for watching! 🙏🏽😊
Great video! Is there a video for the following? I want to install a new ceiling fan with light that has black, white, and red wires. The current switch in the wall only has black and white. How would I add/install an additional wire in the wall for this?
No hablo ingles !! Pero esta muy bien explicado . muchas gracias amigo Dios lo bendiga.
Thank you so much my friend! 🙏🏽😊
Thanks, Pare!
Super helpful, thank you
Thanks!
Well detailed and understandable for us DIY's. I do have a question. If the switch is wired with 14.2 wire, can I use a pig tail from the black wire that would function as the red wire?
Very helpful and clear w/one exception: You left the neutral wire over at the switch off the switch as a loner but it looks like you attached the other end of that neutral on the plugs neutral side bottom...how come? Why not leave it off the plug like the other end loner...it seems to serve no purpose connected. What am I missing? Thx for your video!
I’m super late to the party but decided to answer you anyway.
You’re right, it serve no purpose right now. But if you eventually tap into that switch to add another outlet or if you decide to add a switch with a timer or a lighted switch you’ll need that neutral. You then have to find where’s that stupid wire is not plugged or if it’s broken. So it’s nice practice to always fully terminate your box.
In such a simple setup it’s pretty easy to resolve but add a dozen outlets with split and without, a couple more switches and then come back in 10 years….
Somehow I think you’re spying on me because every video that you upload is based on my house bcause it’s what I need to repair. Ps. If you need more content, please drop by anytime.
Really?! Haha, If I lived close by I would be more that happy to help! 👍🏽😊
Thank you
Thank you. I wired it perfectly but I didn’t break off that tab, so my switch did nothing. Your vid really helped me. Works great now.
Break it off on the copper side only?
@@michaelbartlebaugh754 yeah just like he did in the video. One side only.
Great video, do you have a video on how to connect a ceiling fan to a switch that controls an outlet?
Great video dude, very well done.
Really appreciate you for this video! This worked perfectly for our 1960 home renovation! Thoughts on doing the same but split a GFCI?
Cannot split a GFCI.
Great video, how would I connect a ceiling fan to this set up? Thanks
Very clear explanation. Thank you very much. I have one question that I search around couldn't find the answer. I want to replace the old range hood but the new one is 220V voltage in stead of 110v. As fast as I understand that in the kitchen there is only one 220v outlet for the stove/range applicance. Is that possible I can splite the 220v outlet into 2, so that one for the stove/range and one for the range hood? If so, can you show me how? Or you suggest to me with other solution. Thank you for your help in advance.
Excellent! Question: The N wire you have capped in the switch box -- if you have other neutrals in this box that are all tied together, could you attach this N wire to the bundled other N's?
Great video, just a question, how will be the wiring for a second outlet ( meaning, 2 outlets controlled by the on/off switch)
@fixthishouse Good info! Do you have a video explaining how to change this setup to change the switch to operate newly installed ceiling lighting where there is currently no power source, while also making both outlets always live?
GERAT JOB
Thank you 🙏🏽!
A good way to know if u have a 20amp outlet is if the hot is in a T shape. 🤙🏻 hope that’s helpful
…. You prefer waygos over wire nuts!?
U got that backwards it's the natural side of the recptical that has a T slot on 20 amp rated recpticals
Great video. Is it possible to add an additional receptacle from this circuit. I have this circuit in my kitchen island, the switch powers the garbage disposal and the other outlet is for my dishwasher. How can I grab power from this circuit to add a receptacle on the side of my island.
I would like to have the always on outlet on the bottom instead of the top That way you can plug in a power adapter on the lower outlet because it takes up so much space that way you can plug a light in the upper outlet and have room
Had some issues, Watch video and solved it, thanks.
This was extremely helpful. I do have a couple of questions:
1. Can you add a light to the switch power source?
2. Can you put a dimmer on the switch?
Thank you!
1 are you talking, connecting the light to the switch? Be pacific
2. Yes. You gotta do it from the switch to the dimmer or you can buy a switch that has a dimmer in it
Thank you so much for your channel! Appreciate the tutorials! Question: I am wiring a half-hot receptacle to a double light switch, and another light that is currently wired to a switch... I am using 14/2, would you happen to have a diagram on wiring? I get confused when I see a red wire lol. Thanks bro!
Can you build a visual scenario, where one is bringing power from a ceiling flat Halo LED light to a new switch to control a different pair of lights. So my story is similar to the mentioned scenario. I am pulling power from this existing ceiling light and extending the wiring to these 2 new switches. There are 4 existing LED lights in the hallway that are being controlled by 2 other switches, one on the top of the stairway and the other at the bottom of the stairway and so the 4 LED lights are being divided by a new wall, where the 2 end lights are now in a room and that's where the 2 switches come in. One to work with the other stairway switches to control the hallway lights and the other to control and room lights. Thank you so much. You are awesome in explaining the different ways to get lights situated.
Thank you so much! From your explanation I will need to try to figure out a diagram, I’m getting kinda confused 😅. Please give me time 🙏🏽
@@FixThisHouse Sure, take your time....
Great explanation. I need to do this in a bath renovation. Would it be acceptable to NOT connect the neutral wire of the 14/3 at the receptacle box and just terminate it as you did in the switch box since it's not used ?
My question as well...
When testing for absence of power on a duplex receptacle with a tester, and you find there is no power to the top receptacle, can you assume that there is also no power to the lower receptacle?
so helpful! what would I do if I want to have the top controlled by one switch and bottom by another switch?
That’s a great question and how NEC prefers it. Plus he cloud have re-identify the neutral as a hot
Gonna load a video to show you the difference
Can you do a video demonstrating a 3 way with this system
With this same scenario with a switch powering a split outlet. How can I add a dimmable switch powering a new chandelier I installed? Do I get power from the switch or I just add a dimmable switch replacing the old switch?😅
is there a video that you have which explains what to do when the power is coming in through a dual gang switch box first and the outlet is at the "end" of the circuit? I cannot for the life of my figure out how to sort what I need. I need the same result you've described here, split outlet.
Hey, is it possible to wire a switch outlet combo to control a switch outlet and a constant on one. The switch is for a garbage disposal. If it's possible can you make a video please.
Have any videos on how to fish 🎣 wire through finished drywall with no attic access?also another good one would be what not to do to get electrocuted.
Hi! Thank you for giving me topics to cover! I will have them out soon! Stay tuned! 🙏🏽😊
How do I reverse this? Bought a home with an outlet wired this way, do I just buy a new plug that has the connection still in tact and just wire it in normally? I guess I can disregard the extra red hot wire?
It would be good if you included a circuit breaker on your mock-up wall.
I recently installed a ceiling fan using light switch to power light on fan. On light switch I have one black connected to top for the fan, then at the bottom I have 2 blacks connected together (original one comes the attic, other below assuming is outlet where lamp once lived) to a pigtail connected to the bottom of the light switch. The light works and ceiling fan also.
Prior to doing this, I never had a center light in the ceiling, I had to plug a lamp to an outlet on the bottom right which was source of power on/off.
Ever since I did this my outlet is not providing power anymore, I tried plugging TV nada, I’m lost and need help because it’s driving me crazy 🤯🤯🤯 am I missing a step? This outlet in question looks like it also powers 2 more outlets. On the light switch box I see RED wire, where the lamp was connected I also noticed another RED wire. Those the red wire need to be used again to power all 3 outlets? need guidance.
please show how to wire existing or new switch to new breaker on electrical panel
Never knew about those little tabs. I thought I bought the wrong type of outlet.
If I want top and bottom outlets to be hot just don’t break the metal tabs right?
My switch controls the top outlet only. The bottom outlet is always live but is not controlled by the switch. Hope that makes sense and helps.
Can I add a dimmer switch to that same wiring configuration?
what if the switch your dealin with is double throw switch? does this change this concept? i have 3 lights that plug into my ceiling boxes..... i had wired to my double switch so i could only turn one entry light on if i wanted or flip both switches for all the ligths......... I since added a heater to my ceiling and I need of the outlets to be hot all the time for the heater plug. why im watching this vid to learn how to make a receptacle hot permantley and one switched.
can this be done in reverse? i have the 3 wires coming in with the power that was connected to the switch and the two wires on the other side of the wall connected to the receptical.
What if the plug has two switches that control it, would that make any difference?
I noticed you broke the tab on the outlet on the right hand side what happens if you break the tab on the left hand side and not the right hand side?
Can you do a video with half hot outlet with power to switch ?
thanks bro my dumb ass snapped both tabs and I was so fucking confused hahaha
If the white wire in the 3 wire cable is redundant, then it can be marked by red tape to replace the red wire.
As long as it is clearly identified, this will save the higher cost of using 3 wire cable.
Agree ?
The switch will still work independently.
Ok so where does the white wire go to again? I think I might need to find a video on how to DIY hire an electrician for this little project
Is there a way to do this just using 14-2?
I have 4 ceiling lights in a row in my hallway. I am trying to separate them in 2 sets by attaching 2 switches, one to control the first 2 lights and the other switch to control the last 2. I am pulling power from the 3rd light from the ceiling. There are 2 14/2 wires in the ceiling, one is the power source and the other (with no power) I believe is going to the 4th light fixture. Could you help me with the wiring in this scenario.
Hi! I think the double gang switches to end of run fixture is best for this. All you have to do is add 1 extra light after each fixture. Check out the video I made on this. m.czcams.com/video/mxbaqegYxBU/video.html
What if the power source is going through the switch first?
I removed the metal that makes the connection in the outlet and now one part has no power at all. Following every direction. Any ideas on why there is no power to the top outlet now?
What would happen if I plugged a 2 plug power splitter into an outlet that's half hot? I ask because I almost did this before I realized it's a half hot outlet
Did you just break the tab????I have the same issues with garbage dispo/dishwash and trying to figure out how to switch a regular outlet to a gfci outlet it’s a 14/3 cable
I have a switched outlet that only has a black wire and a white wire. House was built mid-60's. The homeowner claims the bottom was switched and the top always hot. Is that possible? Maybe she is confused and both top and bottom were switched
Where can I find a split outlet with bottom controlled by switch that has a built-in USB port?
Should wirenut neutrals and not use receptacle as the wire nut
Can you use a 14/2 wire for that entire set up instead of the 14/3? I have an outlet that has 3 sets of 14/2 wires. One is going from power to outlet, one set is coming from a switch and one wire going to another outlet down the line. I was going to connect the switch wire to the bottom and the other two sets i was going to combine/pigtail them and put it on top. Please let me know if that's acceptable. thanks
Yes, from the switched receptacle to the switch you can use the white wire as a hot wire (switch leg). Mark the wire with black or red electrical tape at each end to designate hot, not neutral in this case.
And keep the connecting tap intact on the neutral side as it'll act as a common neutral for both receptacles
Curious why I am not getting power to the switch at all, I am getting power to half an outlet but no power to the switch even breaking off center tab, then I have another switch in same room that doesn't work but it has full power in the outlet top & bottom but again switches are not working even after buying new rocker switches & outlets?
What about if I want to reverse it have 2 hots on all the time
Is the neutral at the switch necessary for code? Or can I just use 14/2 and make neutral hot with tape because that's how my teacher taught us here in California? I'm currently in school to become a electrician.
Another commenter made the same observation. Yes, that is a simpler way.
Is there any reason you cant flip the set up and have the top be switch controlled? Watched a Canadian video with that set up but i have 2 middle of the run outlets that are currently switch controlled on the bottom and want the top to be so the wall sconce plug will reach easier.
No reason, your choice.
How do I do this with an existing switch? That is already wired in a closed wall
What happens if you accidently connect the neautral wires backwards?
do you break off the tabs on each side of the electrical receptical or just the brass side?
Just did some research on this. Unlike here, I'm using 12/2 for both circuits, so it's important NOT to break away the connecting tab on the neutral side.. as it'll act as a common neutral for both receptacles, since in my configuration, the white wire coming from the switch will be "hot" so the common neutral will carry the power back to the breaker
Let me know if that makes sense
@@priyanknaik6458 makes sense thank you
My switch seems to control both outlets on/off by the switch does that mean it’s wired differently?I would like to get power from outlet to run led pot lights does that mean my tabs not broken off?
Did you break off the brass side tab?
Care must be given here:
Always turn off power first and double check you did.
Two scenarios just to mind.
1) they sent power to the recepticle box first( like he did) but they connected the hot to the switch wire and bypassed the recepticle in the box. Then they came back from the switch to the recepticle without breaking the tab. This is fixable by following his video.
2) they sent power to the switch first. I cannot see a fix without replacing the cable from the switch to the recepticle with 14/3 or 12/3. Red as constant hot, black as switched hot, white as neutral and bare for ground.
Do not be afraid to get a pro involved to help.
What happens if you don't take off the tab in the middle of the receptacle?
What happens if before I put a new outlet in the top outlet on all four outlets it’s controlled by the switch. I put one brand new outlet in and now none of them are controlled by the switch and I wired it the same way it was.
I’m having the same issue. Did you get it resolved?
why connect 14-3 wire if your not using it on switch>
Can you do this, but with the power coming from the switch switch?
Yes I also would like to see the demonstration of that situation.
Why don’t you remove the other silver tab?
How do you do a split receptacle 3way?
What do you mean by 3 way?
Need a schematic or diagram. I understand things like this visually.
Why wasn’t the white wire used?
Wago needs to make 4 port lever nuts. Its so annoying
I know right! It’s so weird they don’t have that! 😅