One way slab Vs Two way Slab | மடிப்பு கம்பி Crank rods | Deekshi Homes

Sdílet
Vložit
  • čas přidán 13. 08. 2022
  • One way slab vs two way slab | Roof slab reinforcement | Roof reinforcement in detail | Why to provide Cranks in roof reinforcement
    Deekshi Homes
    9940 667 567

Komentáře • 49

  • @ramanlaxman9536
    @ramanlaxman9536 Před rokem +6

    எளிமையாகவும் புரியும் படி சொன்னதற்கு நன்றி 👍🏻

  • @hariharan-qv4ch
    @hariharan-qv4ch Před rokem +8

    The way you explain . Even a non engineering guys also understand. It's help a lot . Thank you 😊

  • @pragha9113
    @pragha9113 Před 13 dny

    Very informative video ,simply awesome,clear explanation 💐

  • @govind9329
    @govind9329 Před rokem +1

    Very Nice. Well explained 👏 👌

  • @boobalchandran4613
    @boobalchandran4613 Před rokem

    Very very superb explanation Er. Tq

  • @sureshm8522
    @sureshm8522 Před rokem +1

    Simple and clear explanation

  • @elumalaik8017
    @elumalaik8017 Před rokem +1

    Thank you so much sir very Usefull video

  • @dvmuthukumarveluswamy9361

    Really Good explanation bro... Your knowledge transfer would be appreciated 👍

  • @newtoncalls
    @newtoncalls Před rokem

    Hari brother your voice sounds great 👍 when you are not facing the camera

  • @brittojohn1844
    @brittojohn1844 Před 3 měsíci

    Very useful Thanks

  • @jenilia7339
    @jenilia7339 Před 11 měsíci

    Excellent sir...

  • @tilakareswaran576
    @tilakareswaran576 Před rokem

    Useful sir 👍👏

  • @priyasunil9738
    @priyasunil9738 Před rokem +2

    Do you undertake repair works for a commercial building?

  • @rxraja441
    @rxraja441 Před 5 měsíci

    sema explain anna

  • @praveenkumar-fo6sw
    @praveenkumar-fo6sw Před rokem +2

    What would happen if we design a one way slab instead of two way slab room sizes are 17*11,10*10,7*9&9*8

  • @iyyappang5444
    @iyyappang5444 Před 8 měsíci

    Super

  • @makeiteasy9723
    @makeiteasy9723 Před měsícem

    Thanks for info. for 10 ft x 6 ft room , 10/ 6 , ~ 1.6 so 2 way slab . for small room like this main and distributor rod 8 mm diameter is OK ? how it is decided for how much length 10 mm dia or 8 mm dia is OK ? Thanks

  • @Rajapostman6031
    @Rajapostman6031 Před 11 měsíci

    Veettukku vasthu outer measurement pakkanuma illa inner measurement pakkanuma sir😊

  • @swathi.n8871
    @swathi.n8871 Před rokem +3

    Hi Hari sir. Nice explanation. We are extending an additional room in our old house. Our new room is 10*8. Oru engineer said as area is small , crank on two sides of Lx (8 ft) will be enough. We have used paste to concel with old building on the Ly end (10ft end) ... Will this create any big issues?

    • @deekshihomes
      @deekshihomes  Před rokem +1

      From your data there is no issues in this

    • @swathi.n8871
      @swathi.n8871 Před rokem

      Thanks for the confirmation... No issues because the area is small? The crank concept of one way slab is followed in our two way slab room.

    • @deekshihomes
      @deekshihomes  Před rokem +3

      Yes as the area and load is very minimal not to worry about it

  • @nagendranradhakrishnan4764

    How to calculate the Crank distance is 1/3 or1/4.explain pl.

  • @ariharan27
    @ariharan27 Před rokem

    Crank point evolo vaikkanum sir

  • @_kid_kurama_43111
    @_kid_kurama_43111 Před rokem

    Tamilnadu la enga la ne v2 kati kudukiringa?

  • @veeramaniselvaraj
    @veeramaniselvaraj Před 4 měsíci

    One way slap க்கு 12mm×10mm பயன்படுத்தலாமா சார்?

  • @isaacraj5339
    @isaacraj5339 Před rokem

    Our hall room is 16*10 but crank also done and on center of both concealed beam also given on full length of room will this beam create any problems

    • @deekshihomes
      @deekshihomes  Před rokem

      Kindly share images in whatsapp @ 9940 667 567

    • @isaacraj5339
      @isaacraj5339 Před rokem

      @@deekshihomes it is already finished but we are going to build first floor so only

  • @naveensj6
    @naveensj6 Před rokem

    Bro , how many rods are required and at what inch we should place at anh methods kindly reply bro

    • @naveensj6
      @naveensj6 Před rokem

      What size rods are required?? And what are their necessities??

    • @deekshihomes
      @deekshihomes  Před rokem

      For those you need to get structural drawing

  • @RENACONBUILDING
    @RENACONBUILDING Před 10 měsíci

    Crank degree + crank அடிச்சதுக்கு அப்புறம் டிஸ்டன்ஸ் எவளோ இருக்கனும் sir

  • @KrishnaMoorthy-mq1jc
    @KrishnaMoorthy-mq1jc Před rokem +1

    Super but Tamil la sollunga

  • @dharanidhamarai2545
    @dharanidhamarai2545 Před rokem

    🙏👍👏👏👏👏👏🤝

  • @VenkatVenkat-pm2em
    @VenkatVenkat-pm2em Před rokem

    2bhk plan &structural design kidaikuma

    • @deekshihomes
      @deekshihomes  Před rokem

      Reach us on whatsapp for drawings. 9940667567

  • @thirumalaivasant9322
    @thirumalaivasant9322 Před rokem

    Sp34 code book bro

  • @nilamakillifestyle4558

    Sir marbles fix pannanum enna mathiri steps follow pannanum

  • @ajithcaxton7023
    @ajithcaxton7023 Před rokem

    Sir any vacancy for your construction company

  • @ismailkahn8607
    @ismailkahn8607 Před 9 měsíci

    நான் மதுரை பக்கம்,,, உங்க நம்பர் கிடைக்குமா

  • @muthumani1170
    @muthumani1170 Před rokem

    Unga num solunga bro

  • @Rajapostman6031
    @Rajapostman6031 Před 11 měsíci +1

    Unga contact number kedaikkuma sir

  • @tilakareswaran576
    @tilakareswaran576 Před rokem

    Useful sir 👍👏

  • @makeiteasy9723
    @makeiteasy9723 Před měsícem

    Thanks for info. for 10 ft x 6 ft room , 10/ 6 , ~ 1.6 so 2 way slab . for small room like this main and distributor rod 8 mm diameter is OK ? how it is decided for how much length 10 mm dia or 8 mm dia is OK ? Thanks